Product Information
Tools and Materials
If service is necessary, contact Sub-Zero factory certified service with the model and serial number. For the name of the nearest Sub-Zero factory certified service or for questions regarding the installation, visit the contact & sup- port section of our website, subzero.com or call Sub‑Zero customer care at 800-222-7820.


Opening Dimensions
MODELS 424G AND 424FSG
DUAL INSTALLATION
When installing two units side by side in a dual installa- tion, the opening width is determined by adding the single opening widths together.
Dual installation kits are available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. For ques- tions regarding the installation, call Sub‑Zero customer care at 800-222-7820.
TOP VIEW
W OPENING WIDTH 341/2" (876) OPENING
SIDE VIEW FRONT VIEW

Electrical
Preparation
Installation must comply with all applicable electrical codes.
To operate properly, the door must open a minimum of 90°. Use a minimum 3" (76) filler in corner installations to assure a 90° door opening.
The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, servicing only this appliance is required. A ground fault cir- cuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Uncrate the unit and inspect for damage. Remove and recycle packing materials. Do not discard the kickplate, anti- tip bracket, hardware and the leveling legs which hold the wood base to the bottom of the unit.
Do not use an extension cord, two-prong adapter or remove the power cord ground prong.
151/2" (394) 2" (51)
Electrical supply location.
3" (76)

Anti-Tip Bracket
MODEL 424FSG
To prevent the unit from tipping forward, the anti-tip bracket must be installed.
The back of the anti-tip bracket must be installed 245/8"
(625) from the front and centered behind the unit. Refer to the illustration below. Refer to page 13 for wood and con- crete floor applications.
The anti-tip bracket should be attached to the wall behind the unit with the bracket flange located 1/4" (6) above the top of the unit. Refer to the illustration below. Failure to properly position the anti-tip bracket will prevent proper engagement.

For installations that cannot accommodate the anti-tip bracket, a countertop bracket is provided to secure the unit to the countertop. Refer to the illustration below.

Custom Panel
MODEL 424G
To mount the custom panel, open the door and use pre- drilled holes to position the panel. Drive screws into the panel through black tape on the door frame. Screw holes are hidden behind the door gasket. Use as many screws as necessary to secure the custom panel. Refer to the illustra- tion below.
For overlay applications, a custom door panel must be installed. Panel size is critical for a proper fit. To verify panel requirements and dimensions, refer to the Sub-Zero design guide at subzero.com/specs
Finish all sides of the custom panel. They may be visible when the door is open or through the glass door.
Adjustments can be made to the custom panel with a few mounting screws in place, but not fully tightened. Once the proper position is achieved, install and secure all screws.
The custom overlay door panel is attached using screws provided, through the door frame. Screw locations are marked on the back of the custom panel using tenon cen- ters inserted into holes of the door frame.
Cover holes on the inside of the door frame with the cover patches or plugs provided.
With the unit secured and door closed, hold the custom panel in desired position on the door. Lightly tap the front of the panel to locate mounting positions. Remove tenon centers. Refer to the illustration below.
A solid panel cannot be installed over the glass door. A solid door is available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com.
The door frame has mounting holes to accommodate Sub-Zero accessory handles. If handle mounting holes are not utilized, the handle should be attached to the custom panel prior to mounting. Screw heads may need to be coun- tersunk into the panel for proper alignment.
GASKET
13 / 32 " (11) DIAMETER
TENON CENTER
GLASS
1 / 4 " (6) DIAMETER
Tenon center.
Door frame cross section.

Placement
Alignment
LEVELING
Before moving the unit into position, secure the door closed and protect any finished flooring.
Level the unit before sliding it into position. Turn each of the four leveling legs clockwise to raise the unit and counter- clockwise to lower. Refer to the illustration below.
Use an appliance dolly to move the unit near the opening.
If the unit has been on its back or side, it must stand upright for a minimum of 24 hours before connecting power.
The top and bottom cabinet hinges are held in place with three permanent adjustment screws. For adjustments, loosen the screws, adjust the door and tighten screws. Refer to the illustration below. For model 424FSG, only the bottom door hinge can be adjusted.
If the unit will be connected to a home security system, run lead wires through the compressor compartment prior to positioning the unit. Refer to page 9. Once the unit is in position, wiring connection can be completed from the front.
SCREW
LEVELING LEGS
Leveling.
Door adjustment.

Completion
Plug the power cord into the grounded outlet, then slide the unit into position. Verify the anti-tip bracket is properly engaged.
To anchor, use the countertop bracket provided to secure the unit to the underside of the countertop. Refer to the illustration below. If the countertop bracket can not be utilized, install shims along the top and sides of the unit.
It may be necessary to install the unit 1/4" (6) beyond the front surface of adjacent cabinetry, to prevent interference when the door is opened to 145°. Refer to the full-scale template on page 10.
Install the kickplate using the two screws provided. Refer to the illustration below. The kickplate must be removable for service. The floor cannot interfere with removal. Do not cover the louvered section of the kickplate.
If the unit will be connected to a home security system, make connections to the leads shown in the illustration below. Refer to the following color codes:

Use the spade terminals or wire nuts provided to make proper wiring connections.

The alarm circuit in the unit is intended as a low- voltage, low-current device only. It should not be used to switch line power. Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.

Home security connection.

Door Clearance
FULL-SCALE TEMPLATE
To allow for a 145° door opening, the unit should extend a minimum of 1/4" (6) beyond the front surface of adja- cent cabinetry. The unit can be installed flush, however, there is potential for interference with the panel if the door is opened past 90°.
ADJACENT CABINETRY
UNIT
DOOR CLOSED
1/2" (13)
1/4" (6)
1/8" (3)
HINGE DETENT AT 145° OPENING (DOOR OPENS PAST 145°)
145° door opening (top view).
1" (25) 0"

Opening Dimensions
MODELS 427G AND 427RG
DUAL INSTALLATION
When installing two units side by side in a dual installa- tion, the opening width is determined by adding the single opening widths together. A dual installation kit is required, but does not affect the opening width.
DEPTH
Dual installation kits are available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. For ques- tions regarding the installation, call Sub‑Zero customer care at 800-222-7820.
W OPENING WIDTH H OPENING
HEIGHT
SIDE VIEW
FRONT VIEW
The depth of models 427G and 427RG is 24" (610). Allow for panel thickness when planning the finished opening depth.

Electrical
Preparation
Installation must comply with all applicable electrical codes.
Uncrate the unit and inspect for damage. Remove the wood base and discard shipping bolts and brackets. Remove and recycle packing materials. Do not discard the kickplate, anti- tip bracket and hardware.
The electrical supply must be located within the shaded area shown in the illustration below. A separate circuit, ser- vicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause inter- ruption of operation.
The electrical outlet must be positioned with the grounding prong to the right of the thinner blades.
The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded.
Control cable (model 427RG).
Do not use an extension cord, two-prong adapter or remove the power cord ground prong.
21/2" (64)
41/2" (114)
1/4"
Electrical supply location.
13" (330) · (6)

Anti-Tip Bracket
WOOD FLOOR
To prevent the unit from tipping forward, the anti-tip bracket must be installed.
After properly locating the anti-tip bracket in the opening, drill pilot holes 3/16" (5) diameter maximum in the wall studs or wall plate. Use the #12 screws and washers to secure the brackets. Verify the screws penetrate through the flooring material and into wall studs or wall plate a minimum of
The back of the anti-tip bracket must be installed 24" (610) from the front of the unit (without panels).
3/4" (19). Refer to the illustration and chart below.
Use all anti-tip bracket hardware as instructed for wood or concrete floors.
After properly locating the anti-tip bracket in the opening, drill pilot holes 3/16" (5) diameter maximum in the wall studs or wall plate. Drill 3/8" (10) diameter holes into the concrete a minimum of 11/2" (38) deep. Use the #12 screws and washers to secure the brackets to the wall, and use the 3/8" wedge anchors to secure the brackets to the floor. Verify the screws penetrate wall studs or wall plate a minimum of

3/4" (19). Refer to the illustration and chart below.
12 #12 x 21/2" pan head screws
MODEL A 427G and 427RG 131/2" (343)
4 3/8"–16 x 33/4" wedge anchors
4 #8–18 x 11/4" truss head screws

Wood floor.
Concrete floor.

Anti-Tip Bracket
Custom Panels
CONCRETE WEDGE ANCHOR INSTALLATION
For models 427G and 427RG, custom panels and handle hardware must be installed. Stainless steel panels are available through an authorized Sub‑Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com.
1 Drill a 3/8" (10) diameter hole any depth exceeding the minimum embedment. Clean the hole or drill additional depth to accommodate drill fines.
2 Assemble the washer and nut flush with the end of anchor to protect threads. Drive the anchor through the material to be fastened until the washer is flush with the surface material.
PANEL WEIGHT MAX Door 20 lb (9 kg) Drawer (427RG) 12 lb (5 kg)
3 Expand the anchor by tightening the nut 3–5 turns past hand-tight position or to 25 ft-lb of torque.
PANEL THICKNESS MIN All Panels 5/8" (16)
Reveals between panels can vary, 1/8" (3) reveals are typical.
Verify there are no electrical wires or plumbing in the area which the screws could penetrate.
When using a panel thicker than 3/4" (19) with reveal less than 1/4" (6), panel may cause damage to the unit when door is opened to 105°. Use the built-in 90° door stop.
Always wear safety glasses and use other necessary protective devices or apparel when installing or working with anchors.
Anchors are not recommended for use in lightweight masonry material such as block or brick, or for use in new concrete which has not had sufficient time to cure. The use of core drills is not recommended to drill holes for the anchors.
As reveals between cabinetry and the unit decrease, severe finger pinching can occur while door is closing.
Finish all sides of the custom panel. They may be visible when the door is open or through the glass door.
D-style handles are recommended. Stainless steel tubular and pro handles are available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. The door handle must be located near the edge of the panel opposite the hinge and should be centered top to bottom.
A solid panel cannot be installed over the glass door. A solid door is available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com.

Panel Installation
The custom overlay door panel is attached using screws provided through the door frame. Screw locations are marked on the back of the custom panel using tenon cen- ters inserted into holes of the door frame.
Remove the mounting hardware attached to the front of the unit and set aside. Place the panel face down on a pro- tected work surface.
With the unit secured and door closed, hold the custom panel in desired position on the door. Lightly tap the front of the panel to locate mounting positions. Remove tenon centers. Refer to the illustration below.
Position the top edge of the template flush with the top edge of the panel. Depending on the height and thickness of the lower drawer panel, the bracket may need to be inverted for proper placement. Mark and drill pilot holes, then secure brackets to panel using the #8 x 1/2" screws provided. Refer to the illustration below.
The door frame has mounting holes to accommodate Sub-Zero accessory handles. If handle mounting holes are not utilized, the handle should be attached to the custom panel prior to mounting. Screw heads may need to be coun- tersunk into the panel for proper alignment.
To help with placement of drawer panels, examine the lower L-bracket and panel to determine the slotted holes on the bracket that will be used. Then position screws into the lower portion of the drawer that correspond with these slots. Leave the screws out slightly so the slotted holes will slide under the heads.
To mount the custom panel, open the door and use pre- drilled holes to position the panel. Drive screws into the panel through black tape on the door frame. Screw holes are hidden behind the door gasket. Use as many screws as necessary to secure the custom panel. Refer to the illustra- tion below.
Install the panel by engaging the tabbed bracket to the top of the drawer, then rotate the panel until the lower bracket is properly positioned below the drawer. The panel can be adjusted 1/4" (6) up and down and side to side.
Adjustments can be made to the custom panel with a few mounting screws in place, but not fully tightened. Once the proper position is achieved, install and secure all screws.
Once the panel is properly aligned, attach the remaining #10 x 1/2" screws to the mounting bracket.
Cover holes on the inside of the door frame with the cover patches or plugs provided.
Reconnect the control cable before reinstalling the top drawer. Refer to page 12.


Tenon center.
Door frame cross section.
Template position.
Drawer panel installation.

Placement
Alignment
LEVELING
Before moving the unit into position, secure the door/ drawers closed and protect any finished flooring.
Once the unit is in position, height adjustment can be made from the front. Using a standard screwdriver, turn front leveling legs clockwise to raise the unit or counterclockwise to lower. Using a Phillips drive, turn rear adjustment screws clockwise to raise the unit or counterclockwise to lower. Use the lowest torque setting when using a power drill (18 revo- lutions equals 1/16" of height adjustment). Do not turn the rear leveling legs by hand. Refer to the illustrations below.
Use an appliance dolly to move the unit near the opening. Front and rear leveling legs can be adjusted from the front once the unit is positioned.
If the unit has been on its back or side, it must stand upright for a minimum of 24 hours before connecting power.
Level the unit to the floor, not surrounding cabinetry. This could affect the operation of the unit, such as door closing. When the unit is properly leveled, door/drawer adjustments are less likely to be necessary.
If the unit will be connected to a home security system, run lead wires through the compressor compartment prior to positioning the unit. Refer to page 17. Once the unit is in position, wiring connection can be completed from the front.
Secure the unit in place using the side mounting clips and #8 x 1/2" screws provided.
Plug the power cord into the grounded outlet, then slide the unit into position. Verify the anti-tip bracket is properly engaged.
To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor.
Front adjustment.
Rear adjustment.

Completion
TRIM INSTALLATION
KICKPLATE INSTALLATION
Install decorative trim strips to the top and sides of the unit. Attach the top trim using the double-sided velcro, then snap side trim over brackets on the sides of the unit. Refer to the illustration below.
Install the kickplate using the screws provided. The mounting bracket may be adjusted slightly for a flush fit. The kickplate must be removable for service. The floor cannot interfere with removal. Refer to the illustration below.
A decorative kickplate can be added to the factory-installed kickplate but cannot block the kickplate louvers.
If the unit will be connected to a home security system, make connections to the leads shown in the illustration below. Refer to the following color codes:
Turn power on by touching POWER on the control panel.
The door opens to 105°. A 90° door stop is built into the hinge system for installations where the door opening must be limited.
Use the spade terminals or wire nuts provided to make proper wiring connections.
To engage the door stop, use a standard screwdriver and rotate the center cam of the hinge. The adjustment must be made to both upper and lower hinges. Refer to the illustra- tion below.


The alarm circuit in the unit is intended as a low- voltage, low-current device only. It should not be used to switch line power. Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.

Opening Dimensions
STANDARD INSTALLATION
24" (610) OPENING
DEPTH
TOP VIEW
83 3 / 4 " (2127) OPENING
W OPENING WIDTH
HEIGHT
FRONT VIEW SIDE VIEW
If two units are installed side by side, refer to page 20.

Opening Dimensions
FLUSH INSET INSTALLATION
26 3 / 16 " (665) FLUSH
INSET DEPTH
23/16" (56)
CLEATS*
TOP VIEW
11/4" (32)
1/4" (6)
W FLUSH INSET WIDTH
INSET HEIGHT
11/4" (32)
23/16" (56) 3" (76)* TYPICAL
*3" (76) typical depth. Shaded areas will be visible and should be finished to match cabinetry.
Dimensions assume a 3/4" (19) panel thickness. If two units are installed side by side, refer to page 21. FLUSH INSET WIDTH W
4" (102)

Opening Dimensions
DUAL STANDARD INSTALLATION
24" (610) OPENING
DEPTH
TOP VIEW
83 3 / 4 " (2127) OPENING
W OPENING WIDTH
HEIGHT
FRONT VIEW SIDE VIEW
A dual installation kit will be required for this installation.
WS-30 and 30" Built-In Model 593/4" (1518)
WS-30 and 36" Built-In Model 653/4" (1670)

Opening Dimensions
DUAL FLUSH INSET INSTALLATION
26 3 / 16 " (665) FLUSH
INSET DEPTH
23/16" (56)
CLEATS*
TOP VIEW
11/4" (32)
1/4" (6)
W FLUSH INSET WIDTH
INSET HEIGHT
11/4" (32)
23/16" (56) 3" (76)* TYPICAL
*3" (76) typical depth. Shaded areas will be visible and should be finished to match cabinetry.
Dimensions assume a 3/4" (19) panel thickness. A dual instal- lation kit will be required for this installation.
WS-30 and 30" Built-In Model 621/4" (1581)
WS-30 and 36" Built-In Model 681/4" (1734)
4" (102)

Dual Installation
Electrical
If two units are installed side by side, a dual installation kit may be required. Installations without a custom filler strip require a dual installation kit. If a dual installation kit is not specified, a 2" (51) filler strip is recommended between units. Dual installations without a filler strip can only be accom- plished using two units with opposite hinges. Refer to the illustrations below.
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, ser- vicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause inter- ruption of operation.
Dual installation kits are available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. For ques- tions regarding the installation, call Sub‑Zero customer care at 800-222-7820.
Electrical Supply 115 VAC, 60 Hz
The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded.
Do not use an extension cord, two-prong adapter or remove the power cord ground prong.
Opposite hinges.
Same side hinges.
75 1 / 2 " (1918) FROM FLOOR
RIGHT SIDE OF OPENING
Electrical supply location.
Service 15 amp · Receptacle 3-prong grounding-type · 6" (152)

Preparation
Uncrate the unit and inspect for damage. Remove the wood base and discard shipping bolts and brackets. Remove and recycle packing materials. Do not discard the kickplate, anti- tip brackets and hardware.
Completely retract the front leveling legs to allow the unit to be moved into position. The front and rear leveling legs can be adjusted from the front once the unit is in position.
Remove the drain pan to avoid damage, and allow for proper appliance dolly placement.
The grille assembly should be removed prior to moving the unit. To remove, pull out on the bottom edge of the grille and rotate upward. Loosen the two back grille mounting screws and remove the two front grille mounting screws. With the grille held firmly, pull forward to remove. Refer to the illustra- tions below.


Anti-Tip Bracket
WOOD FLOOR
To prevent the unit from tipping forward, the anti-tip brackets must be installed.
After properly locating the anti-tip brackets in the opening, drill pilot holes 3/16" (5) diameter maximum in the wall studs or wall plate. Use the #12 screws and washers to secure the brackets. Verify the screws penetrate through the flooring material and into wall studs or wall plate a minimum of 3/4"
The two anti-tip brackets must be installed exactly 24"
(610) from the front of the opening to the back of the brackets and a minimum of 4" (102) from the sides of the opening. This depth will increase to 263/16" (665) for a flush inset installation, based on 3/4" (19) thick panels. Failure to properly position the anti-tip brackets will prevent proper engagement.
(19). Refer to the illustration below.
After properly locating the anti-tip brackets in the opening, drill pilot holes 3/16" (5) diameter maximum in the wall studs or wall plate. Drill 3/8" (10) diameter holes into the concrete a minimum of 11/2" (38) deep. Use the #12 screws and washers to secure the brackets to the wall, and use the 3/8" wedge anchors to secure the brackets to the floor. Verify the screws penetrate wall studs or wall plate a minimum of 3/4"
Use all anti-tip bracket hardware as instructed for wood or concrete floors.
(19). Refer to the illustration below.


12 #12 x 21/2" pan head screws
4 3/8"–16 x 33/4" wedge anchors
4 #8–18 x 11/4" truss head screws
Wood floor.
Concrete floor.

Anti-Tip Bracket
Custom Panels
CONCRETE WEDGE ANCHOR INSTALLATION
For overlay and flush inset applications, custom door and grille panels must be installed. Panel size is critical for a proper fit. To verify panel requirements and dimensions, refer to the Sub-Zero design guide at subzero.com/specs
1 Drill a 3/8" (10) diameter hole any depth exceeding the minimum embedment. Clean the hole or drill additional depth to accommodate drill fines.
2 Assemble the washer and nut flush with the end of anchor to protect threads. Drive the anchor through the material to be fastened until the washer is flush with the surface material.
Finish all sides of the custom panel. They may be visible when the door is open or through the glass door.
3 Expand the anchor by tightening the nut 3–5 turns past hand-tight position or to 25 ft-lb of torque.
A solid panel cannot be installed over the glass door.
Verify there are no electrical wires or plumbing in the area which the screws could penetrate.
Always wear safety glasses and use other necessary protective devices or apparel when installing or working with anchors.
Anchors are not recommended for use in lightweight masonry material such as block or brick, or for use in new concrete which has not had sufficient time to cure. The use of core drills is not recommended to drill holes for the anchors.

Panel Installation
DOOR PANEL
A .10" (3) space is required between the backer panel and the custom panel to allow the panel to slide into the door frame. Refer to the illustrations below for critical dimensions.
To install the custom door panel, remove the handle side trim molding. Insert a screwdriver tip into the top corner slot on the handle side and pop out the trim. Remove the screws and frame. Refer to the illustration below.
Install handle hardware before inserting the panel. Large D-style handles are recommend rather than knobs. Screw heads must be countersunk into the panel.
The door has a 1/4" (6) frame for the custom panel to slide into. If the panel is thicker than a 1/4" (6), rout an edge around the panel or mount the panel on a sheet of 1/4" (6) thick material, then insert into the frame.
Slide the panel into the frame.
To reinstall the door trim molding, insert the top of the trim into grooves at the top of the door and work downward, snapping the trim into clips on the door frame.
SPACER
SPACER PANEL
PANEL
PANEL
CUSTOM PANEL
BACKER PANEL
BACKER
PANEL
TRIM
5/16" (8) min 1/4" (6) .10" (3)
3/4" (19) typical
Door side trim.
Panel assembly cross section (overlay).
Panel assembly rear view.

Panel Installation
GRILLE PANEL
SIDE PANEL
Remove the bottom grille frame by extracting the lower two corner screws from each side of the grille assembly. Refer to the illustration below.
When installing a custom side panel, an accessory kit is required and is available through an authorized Sub-Zero dealer. For local dealer information, visit the find a show- room section of our website, subzero.com. Stainless steel and white enamel side panels are also available from an authorized Sub-Zero dealer.
With the bottom section removed, slide the custom grille panel into the frame. If the panel is thinner than 1/4" (6), a filler material will need to be installed to achieve a proper fit. Once the panel is installed, reattach the bottom grille frame by sliding the corner brackets back into position, then reinstall the four corner screws.
A custom side panel must be a minimum of 24" (610) deep and 1/2" (13) thick. Routing will be necessary for the side panel to fit flush against the side of the unit. Refer to the illustrations below.


Grille frame assembly.
25/8" (67)
Side panel dimensions.

Placement
Alignment
LEVELING
Before moving the unit into position, secure the door closed and protect any finished flooring.
Once the unit is in position, turn the front leveling legs clockwise to adjust the height. The rear height adjustment can be made from the front of the roller base. Using a 3/8" socket, turn the 3/8" hex bolt clockwise to raise the unit or counterclockwise to lower. Use the lowest torque setting when using a power drill. Do not turn the rear leveling legs by hand. Refer to the illustration below.
Use an appliance dolly to move the unit near the opening.
If the unit has been on its back or side, it must stand upright for a minimum of 24 hours before connecting power.
If the unit will be connected to a home security system, run lead wires through the compressor compartment prior to positioning the unit. Refer to page 30. Once the unit is in position, wiring connection can be completed from the front.
When the unit is properly leveled, door adjustments are less likely to be necessary.
Plug the power cord into the grounded outlet, then roll the unit into position. Verify the anti-tip brackets are properly engaged.
To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor.
REAR ADJUSTMENT
Leveling.

Alignment
Completion
DOOR ADJUSTMENT
GRILLE INSTALLATION
The door can be adjusted in and out, side to side tilt and up and down.
Install the grille assembly and check for proper fit. The grille is designed to rest on the upper door hinge to minimize the reveal between the top of the door and bottom of the grille. To eliminate interference, the grille height can be adjusted. Loosen the four grille adjustment screws (two on each side) and adjust the grille height as needed. Refer to the illustra- tion below.
To make adjustments, slightly loosening the two upper hinge bolts on the upper hinge plate using a 1/2" wrench. Refer to the illustration below.
In and out adjustment | For a left-hinge door, using a
5/32" allen wrench, turn the adjustment bolt clockwise to bring the handle side of the door inward, and counterclock- wise to move the handle side outward. Reverse directions for a right-hinge door.

Side to side tilt adjustment | For a left-hinge door, using a
3/8" wrench, turn the adjustment bolt clockwise to raise the handle side of the door, and counterclockwise to lower the handle side. Reverse directions for a right-hinge door.
Up and down adjustment | For a left-hinge door, using a
1/4" allen wrench, turn the adjustment bolt clockwise to raise the door and counterclockwise to lower. Refer to the illustra- tion below. Reverse directions for a right-hinge door.

Completion
HOME SECURITY CONNECTION
ANCHORING
If the unit will be connected to a home security system, make connections to the leads shown in the illustration below. Refer to the following color codes:
After the unit has been leveled and door adjustment com- pleted, anchor the unit to the opening to ensure a proper fit and secure installation.
To anchor the top of the unit, open the grille and install the screws provided, through the grille frame into cabinetry. There are several hole locations. Refer to the illustration below. Check for proper door clearance by opening the door.
Use the spade terminals or wire nuts provided to make proper wiring connections.
To anchor the bottom of the unit, drive a screw through the side hole inside each roller base assembly. The screw will need to go in at an angle to attach properly. Refer to the illustration below. Additional material may be needed behind the cleat to ensure sufficient anchoring.

The alarm circuit in the unit is intended as a low- voltage, low-current device only. It should not be used to switch line power. Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.

If the screws provided are not suitable for the installa- tion, use adequate screws.


Completion
KICKPLATE INSTALLATION
90° DOOR STOP
Reinstall the drain pan and verify it is in the proper position.
The door opens to 110°. A 90° door stop is provided with the unit (located behind the grille). Additional 90° door stop kits are available through an authorized Sub-Zero dealer.
Install the kickplate using screws to attach it to brackets on the inside of each roller base. Refer to the illustration below. The kickplate must be removable for service. The floor cannot interfere with removal. Refer to the label mounted on the kickplate support for height clearance.
Follow all city and state laws when storing, recycling or discarding unused refrigerators and freezers.
Turn power on by touching POWER on the control panel.
Kickplate installation.
Sub-Zero, Sub-Zero & Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, and Ingredients are registered trademarks and service marks of Sub-Zero, Inc. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appli- ance, Inc. (collectively, the “Company Marks.”) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.