Sterling SDAP

4 pages·901 KB·Clothes Dryer·PDF·ENDEFRITNLJA
Sterling SDAP
Table of Contents 20 sections Quick Start Pre-Startup Checklist · Quick Startup Checklist · Setting the Process Air Temperature · Auto-Tuning the Dryer · … ShowHide
Page 1 of the Sterling SDAP user manual — UP
Page 1 · click to enlarge
Page 1
Sterling SDAP — Quick Start Pre-Startup Checklist diagram (page 1)
Fig. 1 · Quick Start Pre-Startup Checklist

Quick Start Pre-Startup Checklist

1. Check the process and return hoses for tight connections. 2. Check all companion equipment, such as the drying hopper; verify the loading system is ready for operation. 3. Verify all dryer electrical connections are tight. 4. Verify the thermocouple is properly installed at the hopper inlet. 5. Verify temperature unit/scale (°F or °C).

Quick Startup Checklist

1. Turn ON the power disconnect switch in your power drop, then turn ON the power disconnect switch on the dryer. 2. Turn the dryer ON/OFF switch to ON to energize the display panel. 3. Check the display for the proper temperature scale (°F or °C). 4. Close the slide gate at the bottom of the drying hopper. 5. Fill the drying hopper with material. 6. Press the START button on the touch screen to start the dryer (Display will change to SHUTDOWN). The process blower starts.

a. Make sure the blower turns in the correct direction. b. Disconnect the hose from drying hopper to the filter. c. Quickly turn the ON/OFF switch to OFF. You should feel a suction at the inlet of the filter. (Secure the hose back in place).

Sterling SDAP — Quick Startup Checklist diagram (page 1)
Fig. 2 · Quick Startup Checklist

Setting the Process Air Temperature

1. Press and hold the SET POINT Display until a number key pad appears. 2. Enter the values you would like to set in the screen by pressing the number keys. 3. Press ENT (Enter) when you are finished.

Auto-Tuning the Dryer

Sterling SDAP — Auto-Tuning the Dryer diagram (page 1)
Fig. 3 · Auto-Tuning the Dryer
1. From the “Dryer Status” screen, press “Dry Menu”. 2. Select Auto Tune to gain access to this screen. The Access Code into the Auto Tune screen is: 1234 .
3. At this point, the operator can return back to the DRYER MENU or MAIN MENU by touching the appropriate button on the screen.

Setting the Redundant Safety Controller

  • The Redundant Safety Controller alarm setting is changed by pressing the up and down keys, which inputs the alarm value.
Sterling SDAP — Setting the Redundant Safety Controller diagram (page 1)
Fig. 4 · Setting the Redundant Safety Controller
  • The upper display reading indicates the Process Value, while the lower display indicates the High Point Setting alarm value.

UP

& DOWN

  • Sterling Part No: 682.92636.03 2900 S. 160 th Street
  • New Berlin, WI 53151 USA Bulletin No: DH1-315.02 Tel. 262.641.8610
  • Fax 262.641.8653

Keys

Page 2 of the Sterling SDAP user manual — NOMAD II – AD Dryer (Seven Configurations)
Page 2 · click to enlarge
Page 2
Sterling SDAP — Start & Stop Conveying Feature diagram (page 2)
Fig. 5 · Start & Stop Conveying Feature

Start & Stop Conveying Feature

  • From Dryer status screen, press MAIN MENU . From the MAIN MENU screen, press CONVEY STATUS .
  • This screen provides the operator with the current status of M1 (Machine Hopper 1), M2 (Machine Hopper 2), DH (Drying Hopper), MB (Machine Blower), and the HB (Hopper Blower). Within this screen, the operator can access different variables in the conveying system and START or STOP the process.
  • Momentarily pressing the M1 , M2 , DH , MB , or HB icons on the screen will darken or turn them black. This indicates they are active in the conveying system .
  • To access the Operator Screens for the hoppers, press and hold the M1 , M2 , or DH icons on the screen.
  • To get back to the DRYER STATUS screen, press the MAIN MENU button, then press the DRYER STATUS button on the DRYER MENU .

NOMAD II – AD Dryer (Seven Configurations)

Convey to One Machine

Convey to Drying Hopper Only

Sterling SDAP — NOMAD II – AD Dryer (Seven Configurations) diagram (page 2)
Fig. 6 · NOMAD II – AD Dryer (Seven Configurations)
M1 Machine 1 LoaderON OFF ONC P O O N W T R E OR OLF F AHLOARRNM MB Machine
Sterling SDAP — NOMAD II – AD Dryer (Seven Configurations) diagram (page 2)
Fig. 7 · NOMAD II – AD Dryer (Seven Configurations)
H Drying Hopp Loaderer ON OFF HB Hopper

Convey to Drying Hopper With

Convey to Drying Hopper & One

Convey to Drying Hopper & Two

Sterling SDAP — NOMAD II – AD Dryer (Seven Configurations) diagram (page 2)
Fig. 8 · NOMAD II – AD Dryer (Seven Configurations)
  • Sterling Part No: 682.92636.03 2900 S. 160 th Street
  • New Berlin, WI 53151 USA Bulletin No: DH1-315.02 Tel. 262.641.8610
  • Fax 262.641.8653
Show 6 more labels / short text on this page
Configuration "A" · Configuration "B" · Proportioning Valve · Machine Configuration "C" · Machines Configuration "D" · Configuration "BP"
Page 3 of the Sterling SDAP user manual — (Cooling Coil)
Page 3 · click to enlarge
Page 3

Convey to Drying Hopper With

Sterling SDAP — DH diagram (page 3)
Fig. 9

Convey to Drying Hopper With

Proportioning Valve & Two Machines, Configuration “DP”

Proportioning Valve & Two Machines, Configuration “CP”

DH

OFF

ON

M1

M1

MB

HB

MaintenanceAir In Filters: Recommendations for Cleaning and Replacing 1. Turn off and/or lock out electrical power to the dryer. 2. Loosen the clamp, and remove the dust can. 3. Remove the thumb nut, on the center retaining rod, to remove the filter cartridge. 4. Pull the filter cartridge out. Vacuuming • Try vacuum-cleaning a soiled filter first. Vacuuming removes most large particles and surface contaminants, and may suffice for the first time you clean a filter. • Use a commercial-duty (recommended) or household vacuum cleaner. Vacuum the filter from the air intake (dirty) side only. Cleaning with Compressed Air 1. Blow clean, dry, compressed air up and down the pleats, blowing out the filter from the inside out. 2. Remove loose dirt from the filter with compressed air or vacuum from the outside. 3. Inspect the filter element. Briefly hold a light bulb behind the element and look for any fatigued paper or residual dirt. Inspect for holes and tears by looking though the filter toward a bright light. Check for damaged gaskets or dented metal parts. Note: Do not re-use a damaged filter! Cooling Coils: Cleaning and Replacement Procedures 1 1. Shut down the dryer, tag out and lock out the controls if necessary. Und 2. Shut the water off to the cooling coil. Hea 3. Remove the four 10-32 bolts. Alle 4. Gently slide the cooling coil out. 5. Visually inspect the coil for leaks, dirt, and any sign of contaminants. 6. Blow the dust out, or if the coil is covered with plasticizer, steam clean it. 7. Place the coil back in its housing. Make sure the gasket is undamaged; replace if necessary. 8. Inset the four 10-32 bolts back in place. 9. Turn the water to the cooling coil back on.
Sterling SDAP — DH diagram (page 3)
Fig. 10

(Cooling Coil)

  • Sterling Part No: 682.92636.03 2900 S. 160 th Street
  • New Berlin, WI 53151 USA Bulletin No: DH1-315.02 Tel. 262.641.8610
  • Fax 262.641.8653
Show 20 more labels / short text on this page
(Air Flow Schematic) · Drying Hopper · Loader · Valve · Blower · Filter · Desiccant · Tanks · T’Couple · Location · Loader Machine 2 · Machine 1 · Loader · Slide Gate · Process · Machine · Hopper Blower · Heater · Blower · Filter Housing
Page 4 of the Sterling SDAP user manual — Dryer Shuts Down:
Page 4 · click to enlarge
Page 4

Spare Parts List

Sterling SDAP — Spare Parts List diagram (page 4)
Fig. 11 · Spare Parts List
ModelFilterDesiccantRegenerationProcess ThermocoupleGasket Replacement BeadsThermocouple SDAP 25/50/100Standard Temperature – Part # W00052474 High Temperature – Part # 161.00194.0013 X Beads – Part # W0001805125 ONLY – 96” Long – Part # A0568474 50/100 ONLY – 96” Long – Part # A054375815’ Long (Braided Design) – Part # A0568466 72” Long (Braided Design) – Part # A0568473Standard and High Temperature – Part # A0566839

Troubleshooting - Quick Guide

Alarm Message Cause Corrective Action Dryer Status Make sure the process air filter is clean. Clean or replace if necessary. Make sure all the hose connections and all the components of the dryer have proper seals on them (i.e. desiccant tanks, heater box, filters, after-cooler). Tighten the connections and replace any damaged seals. Make sure the regeneration timing cycle matches the specs. If not, contact the Service Department.

Dryer Normal:

The dew point reading has exceeded the dew point alarm set point.

- Process blower ON. - Process heaters ON. - Regen heaters ON. - Alarm Message ON. - Alarm horn is OFF.

Desiccant may be contaminated and blocking the air flow. Check desiccant, replace if necessary.

Make sure the process filter is clean. Clean or replace if necessary. Double check the alarm set point is at 35° F. Check the positioning of the thermocouple inside the air inlet of the drying hopper. The tip of the thermocouple should be centered in the tube, and not touching any metal part of the tube. The drying temperature set point is lower than dryer capabilities. Check the dryer specs. Make sure all the hose connections are tight.

Dryer Shuts Down:

- Process blower OFF. - Process heaters OFF. - Regen heaters OFF. - Alarm light is ON. - Alarm horn is ON.

The process temperature has exceeded the alarm set point.

Make sure the regeneration timing cycle matches the specs. If not, contact Service department.

The limit switch on the valve may not have been wired correctly.

Dryer Shuts Down:

The switch is indicating the incorrect desiccant tank is in regeneration. Check the wiring of the switch against the wiring diagram. Make sure all the wire connections are tight.

- Process blower OFF. - Process heaters OFF. - Regen heaters OFF. - Alarm light is ON. - Alarm horn is ON.

Limit switch may be out of position. Re-adjust the switch so it trips when it is at the high position, and avoids touching the cam when it is at the low position. Valve Motor

The valve has made enough rotations and the correct position of the valve was not detected.

Limit switch may be faulty. Replace the switch and make sure the wires are connected correctly.

  • Sterling Part No: 682.92636.03 2900 S. 160 th Street
  • New Berlin, WI 53151 USA Bulletin No: DH1-315.02 Tel. 262.641.8610
  • Fax 262.641.8653
Show 6 more labels / short text on this page
High Dew Point · Process High · Temp · Valve Positioning · Fault · Override

Ask about the Sterling SDAP

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Sterling SDAP

Be the first to ask — other owners or our team will answer.

Original document

Sterling SDAP manual PDF

4 pages·901 KB·Clothes Dryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…