1. Turn ON the power disconnect switch in your power drop, then turn ON the power disconnect switch on the dryer. 2. Turn the dryer ON/OFF switch to ON to energize the display panel. 3. Check the display for the proper temperature scale (°F or °C). 4. Close the slide gate at the bottom of the drying hopper. 5. Fill the drying hopper with material. 6. Press the START button on the touch screen to start the dryer (Display will change to SHUTDOWN). The process blower starts.
a. Make sure the blower turns in the correct direction. b. Disconnect the hose from drying hopper to the filter. c. Quickly turn the ON/OFF switch to OFF. You should feel a suction at the inlet of the filter. (Secure the hose back in place).



& DOWN
Keys


Convey to One Machine
Convey to Drying Hopper Only


Convey to Drying Hopper With
Convey to Drying Hopper & One
Convey to Drying Hopper & Two


Convey to Drying Hopper With

Convey to Drying Hopper With
Proportioning Valve & Two Machines, Configuration “DP”
Proportioning Valve & Two Machines, Configuration “CP”
OFF
ON
M1
M1
MB
HB



Alarm Message Cause Corrective Action Dryer Status Make sure the process air filter is clean. Clean or replace if necessary. Make sure all the hose connections and all the components of the dryer have proper seals on them (i.e. desiccant tanks, heater box, filters, after-cooler). Tighten the connections and replace any damaged seals. Make sure the regeneration timing cycle matches the specs. If not, contact the Service Department.
The dew point reading has exceeded the dew point alarm set point.
- Process blower ON. - Process heaters ON. - Regen heaters ON. - Alarm Message ON. - Alarm horn is OFF.
Desiccant may be contaminated and blocking the air flow. Check desiccant, replace if necessary.
Make sure the process filter is clean. Clean or replace if necessary. Double check the alarm set point is at 35° F. Check the positioning of the thermocouple inside the air inlet of the drying hopper. The tip of the thermocouple should be centered in the tube, and not touching any metal part of the tube. The drying temperature set point is lower than dryer capabilities. Check the dryer specs. Make sure all the hose connections are tight.
- Process blower OFF. - Process heaters OFF. - Regen heaters OFF. - Alarm light is ON. - Alarm horn is ON.
The process temperature has exceeded the alarm set point.
Make sure the regeneration timing cycle matches the specs. If not, contact Service department.
The limit switch on the valve may not have been wired correctly.
The switch is indicating the incorrect desiccant tank is in regeneration. Check the wiring of the switch against the wiring diagram. Make sure all the wire connections are tight.
- Process blower OFF. - Process heaters OFF. - Regen heaters OFF. - Alarm light is ON. - Alarm horn is ON.
Limit switch may be out of position. Re-adjust the switch so it trips when it is at the high position, and avoids touching the cam when it is at the low position. Valve Motor
The valve has made enough rotations and the correct position of the valve was not detected.
Limit switch may be faulty. Replace the switch and make sure the wires are connected correctly.