Instruction/ maintenance manual of the product GS675YRVLT State Industries
Go to page of 36
1 Thank you for buying this energy efficient water heater . We appreciate your condence in our products. Y ou should thoroughly read this manual before installation and/ or operation of this water heater . Please pay particular attention to the important safety and operating instructions as well as the W ARNINGS and CAUTIONS.
2 SAFE INST ALLA TION, USE AND SER VICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater .
3 GENERAL SAFETY.
4 GENERAL SAFETY.
5 Thank Y ou for purchasing this water heater . Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • ANSI - American.
6 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part .
7 (A) VENT PIPE (B) ANODE (C) HOT W A TER OUTLET (D) OUTLET (120 V AC) (E) FLUE BAFFLE (F) GAS SUPPL Y (G) MAIN MANUAL GAS SHUT OFF V AL VE (H) GROUND JOINT UNION (J) DIRT LEG (K) OUTER DOOR (L) UNION (M) INLET W A TER SHUT OFF V AL VE (N) COLD W A TER INLET FIGURE 1.
8 TYPICAL INST ALLA TION FIGURE 2. MIXING V AL VE USAGE This appliance has been design certied as complying with American National Standard for water heaters and is considered suitable for: W ater (Potable) Heating and Space Heating: All models are considered suitable for water (potable) heating and space heating.
9 F ACTS TO CONSIDER ABOUT THE LOCA TION Car ef ul ly choo se an indo or loca ti on for th e new wate r hea te r , bec au se the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
10 Minimum clearances between the water heater and combustible con stru ctio n are 0 in c h at the sides an d rear , 5. 5” (14.0 cm) from the fron t and 12” (30.5 cm) from the top (standard clearance). If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater .
11 located in the above manner , should be provided. Each opening should have a free area of not less than one square inch per 4000 Btu/hr (5.5 cm 2 /kW) of total input of all appliances in the enclosure.
12 As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow . As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage).
13 Figure 10 shows the typical attachment of the water piping to the water heater . The water heater is equipped with 3/4 inch NPT water connections. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the water heater connections.
14 GAS PIPING M a ke s u re th e ga s s u pp li e d is t he sa m e ty p e li s t e d o n th e m o de l r a ti ng p l at e. T he i n l et g a s pr e s s ur e m u st n o t e xc e e d 1 4 in ch wa te r co lu mn ( 3. 5 k P a) f o r na tu r a l a nd p r op an e ga s (L .
15 SEDIMENT TRAPS A sediment trap should be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap should be either a tee tting with a capped nipple in the botto m outlet or other devi ce recogn ized as an effe ctiv e sedime nt trap.
16 2. A venting system should terminate at least 3 feet above any forced air inlet located within 10 feet. 3. The venting system should terminate at least 4 feet below , 4 feet horizontally from or , 1 foot above any door , window or gravity air inlet into any building.
17 NOTE: This unit can be vented using only the following materials: PVC (Cellular Core; ASTM-F891), PVC (DWV; ASTM D2665 or CSA B181.2), PVC (Sch 40, 80, 120; ASTM D1785 or CSA B137.3), PVC (SDR Series; ASTM-D2241 or CSA B137.3), CPVC (CPVC 41; ASTM-D2846 or CSA B137.
18 4. Do not plug in powe r cord until ven t syst em is comp let el y insta ll ed. The Powe r V ent operate s on 120 V ac, there fore a grou nded outlet must be within reach of the 6 foot exible power cord supplied with the vent. The power cord supplied may be used on unit only where local codes permit.
19 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA TION. VERIFY PROPER OPERA TION AFTER SERVICING.
20 INST ALLA TION OF VENT SYSTEM, SIDEW ALL With the route of the venting system and selection of materials completed, as d is c us s ed in the se cti on of thi s man u al tit le d PL ANN IN G TH E V .
21 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the specic application you are attempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use.
22 B. Deburring Use a knife, plastic pipe deburring tool, or le to remove burrs from the e nd o f s m a l l d i a m e t er p ip e . B e su r e t o r e m o ve a ll b ur r s f r o m ar o un d th e i ns i d e a s w e l l as t he o u t s i d e o f th e p i p e.
23 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a re or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner .
24 The water temperature setting was factory set at th e lowest temperature; Pressing the “COOLER” button decreases temperature and pressing the “HOTTER” button increases the temperature. Setting the water heater temperature at 120°F (49°C) (Approx.
25 FOR YOUR INFORMA TION ST ART UP CONDITIONS SMOKE/ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning of f of oil from metal parts, and will disappear in a short while. THERMAL EXP ANSION As water is heated, it expands (thermal expansion).
26 VENTING SYSTEM INSPECTION At least once a year a visual inspe ction should be made of the ventin g system. Y ou should look for: 1 . Obstructions which could cause improper venting. The combustion and ventilation air ow must not be obstructed. 2.
27 INST ALLED IN SUIT ABLE AREA: T o insure sufcient ventilation and combustion air supply , proper clearances from the water heater must be maintained. See “Locating the New Water Heater” section. Combustible materials such as clothing, cleaning materials, or ammable liquids, etc.
28 LEAKAGE CHECKPOINTS Never use this water heater unless it is completely lled with water. T o prevent damage to the tank, the tank must be lled with water . W ater must ow from the hot water faucet before turning “ON” gas to the water heater .
29 Key No. Part Description 1 Pipe Nipple 2 Stamped Steel Burner 2 A Cast Iron Burner 3 Burner T ube (Stamped Burner) 3A Burner T ube (Cast Iron Burner) 4 Orice (Stamped Steel Burner) 4A Orice (.
30 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualied service technician. Read the GENERAL SAFETY INFORMA TION section rst. INTELLI-VENT TROUBLESHOOTING CHART - RESIDENTIAL CONTROL PROBLEM SOLUTION Inadequate or no earth ground 1.
31 PROBLEM SOLUTION Ignition/ame failure. 1. Gas supply is turned off - pressure too low . Ensure 6 supply and manifold gas pressures are within The water heater has reached the requirements in the installation manual.
32 These guidelines should be utilized by a qualied service agent. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES.
33 NOTES:.
34 NOTES:.
35 THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . If the glass lined tank in this water heater should prove upon examination by the S tat e W ater He at er s ( war ra nt or ) t o h av e l e.
36 500 T ennessee Waltz Parkway , Ashland City , TN 37015 www .statewaterheaters.com.
An important point after buying a device State Industries GS675YRVLT (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought State Industries GS675YRVLT yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data State Industries GS675YRVLT - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, State Industries GS675YRVLT you will learn all the available features of the product, as well as information on its operation. The information that you get State Industries GS675YRVLT will certainly help you make a decision on the purchase.
If you already are a holder of State Industries GS675YRVLT, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime State Industries GS675YRVLT.
However, one of the most important roles played by the user manual is to help in solving problems with State Industries GS675YRVLT. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device State Industries GS675YRVLT along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center