Instruction/ maintenance manual of the product TP03 Stanley Black & Decker
Go to page of 18
© 2012 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 58555 7/2014 V er .12 TP03 HYDRAULIC TRASH PUMP USER MANUAL Safety , Operation and Maintenance.
2 ► TP03 User Manual DECLARATION OF CONF ORMI TY ÜBEREINSTIMM UNGS - ERKLARUNG DECLARATION DE CONFOR MITE CEE DECLARACION DE CONFO RMIDAD DICHIARAZIONE DI CONFORM ITA Hydraulic Tools _______ ______.
TP03 User Manual ◄ 3 SERVICING THE ST ANLEY HYDRAULIC PUMP . This manual contains safety , operation, and routine maintenance instructions. Stanley Hydraulic T ools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an authorized and certied dealer .
4 ► TP03 User Manual Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel.
TP03 User Manual ◄ 5 T ool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose. These safety precautions are given for your safety . Re- view them carefully before operating the tool and before performing general maintenance or repairs.
6 ► TP03 User Manual SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL.
TP03 User Manual ◄ 7 The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
8 ► TP03 User Manual Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber Braid - for Utility Bu.
TP03 User Manual ◄ 9 Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min. operating temperature) T emperature: Sufcient heat rejection capacity to limit max.
10 ► TP03 User Manual PREOPERA TION PROCEDURES CHECK POWER SOURCE 1. Using a calibrated ow meter and pres sure gauge, make sure the hydraulic power source develops a ow of 7–9 gpm/26–34 Ipm at 1500–2000 psi/105– 140 bar .
TP03 User Manual ◄ 1 1 5. When pumping is complete, set the hy draulic control valve to the “OFF” posi tion. Lift the trash pump from the work area using the rope or cable to avoid dam- age to the hoses or couplers. 6. IMPORT ANT Observe the following for trash pump protection and care.
12 ► TP03 User Manual NO TICE In addition to the Safety Precautions found in this manual, observe the following for equipment protection and care. • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the “OFF” position when coupling or uncoupling hydrau- lic tools.
TP03 User Manual ◄ 13 If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem. When diagnosing faults in operation of the tool, always make sure the hydraulic power source is supplying the cor- rect hydraulic ow and pressure as listed in the table.
14 ► TP03 User Manual Capacity......................................................................................................................................... 450 gpm/1688 lpm Weight .........................................................
TP03 User Manual ◄ 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 CARRY HANDLE P/N-73576 QUICK LINK P/N-73577 TP03 P ARTS ILLUSTRA TION.
16 ► TP03 User Manual ITEM NO. P ART NO. QTY DESCRIPTION 1 00635 1 Key 2 01324 1 LOCKW ASHER 1/4" I.D. 3 03786 1 GPM STICKER 4 03975 1 COUPLER,3/8 FEM 1/2NPT 5 03976 1 COUPLER,3/8MALE 1/2NPT 6 .
TP03 User Manual ◄ 17 For underwater hydraulic tools the applications are broken down into four quadrants depending on type of tool and method of operation. The types of tools are percussive and rotational, each with different characteristics allowing for dif- ferent depth operation.
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulics.com.
An important point after buying a device Stanley Black & Decker TP03 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Stanley Black & Decker TP03 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Stanley Black & Decker TP03 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Stanley Black & Decker TP03 you will learn all the available features of the product, as well as information on its operation. The information that you get Stanley Black & Decker TP03 will certainly help you make a decision on the purchase.
If you already are a holder of Stanley Black & Decker TP03, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Stanley Black & Decker TP03.
However, one of the most important roles played by the user manual is to help in solving problems with Stanley Black & Decker TP03. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Stanley Black & Decker TP03 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center