50 Pound Capacity 75 Pound Capacity Refer to Page 3 for Model Identification

Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.)
Part No. M414884R10
February 2008



Installation must conform with local codes.
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
not use any phone in your building. – Clear the room, building or area of all
from a neighbor’s phone. Follow the gas supplier’s instructions. – If you cannot reach your gas supplier,
call the fire department. • Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
M414884 (EN) 1 © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT


Information in this manual is applicable to these models.

Includes models with control suffixes:
BC – basic electronic, coin CD – rotary coin drop RM – reversing OPL Micro
BG – basic electronic, OPL mode CX – prep for coin RQ – reversing dual digital timer
BL – basic electronic, central pay CY – prep for card RT – reversing manual timer
BU – basic electronic, prep card - open MT – manual timer SD – single drop
BX – basic electronic, prep for coin OM –OPL Micro SX – single drop, prep for coin
BY – basic electronic, prep for card QT – dual digital timer
Serial Plate Location
The wiring diagram is located in the junction or contactor box.

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT 3 M414884 (EN)

Important Safety Instructions
Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT M414884 (EN) 4

To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT M414884 (EN) 6


* H, S and U models prior to Serial No 0308001307 and all other models. ** H, S and U models after Serial No. 0308001307.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

B
A
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

A
B
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

A
A
B B
TMB813N GAS AND STEAM ELECTRIC
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

A
B
D
Models Diameter A B C D
050/075 3/4 in. NPT 387 mm (15.25 in.)
1848 mm (72.75 in.)
190 mm (7.5 in.)
1645 mm (64.75 in.)
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances.
TMB2131N NOTE: Shaded areas indicate adjacent structure.
1 13 mm (0.5 in.) recommended between machines for removal or installation 2 Allow 51-102 mm (2-4 in.) opening at top of machine to aid in removal or installation. A removable trim piece may be used to conceal the opening; zero clearance allowed for trim. 3 102 mm (4 in.) maximum header thickness 4 305 mm (12 in.) minimum clearance permitted for remainder 5 Guard 6 Provision for make-up air 7 610 mm (24 in.) minimum, 914 mm (36 in.) recommended for maintenance purposes 8 6 mm (0.25 in.) recommended for removal or installation purposes, zero clearance allowed
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Fire Suppression System G, H, K, S and U Models Only Water Requirements

Connection point to the electric water solenoid valve is a 19 mm (3/4 inch) hose. The fire suppression system equipped tumbler must be supplied with a minimum water pipe size of 12,7 mm (1/2 inch) and be provided with a minimum of 138 kPa (20 psi) and a maximum of 827 kPa (120 psi) of pressure at all times. Flowrate must be no less than, but approximately 57 liters (15 gallons) per minute.
TMB2008N 1 Lock 2 Hose Couplings 3 Y Valve 4 Inlet Hoses 5 Opening for Auxiliary Alarm Cable
Part No. 20617 Inlet hose 2.44 m (8 feet) Part No. 20618 Inlet hose 3.05 m (10 feet)
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Electrical power must be provided to tumbler at all times. The fire suppression system will be inoperative if the main electrical power supply is disconnected.
No independent external power source or supply connection is necessary. Power to operate the 24 Volt fire suppression system is from the rear junction/ contactor box.
During tumbler installation, you have the option to connect a separate alarm system to this auxiliary output. Use of the auxiliary output is not required for the fire suppression system to operate, but may be used for additional protection.
To reduce the risk of fire or explosion, if the tumbler is to be connected to Liquefied Petroleum (L.P.) gas, a vent to the outdoors must be provided in the room where the tumbler is installed.
Gas Requirements
Natural Gas and Liquefied Petroleum
To reduce the risk of fire or explosion, DO NOT CONNECT THE GAS LINE TO THE TUMBLER IF THE GAS SERVICE IS NOT THE SAME AS THAT SPECIFIED ON THE TUMBLER SERIAL PLATE! It will first be necessary to convert the gas burner orifice and gas valve. Appropriate conversion kits are available.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Models are built in two different configurations:
This information is to be used when installing gas tumblers in countries, and/or on gases, different than the machine’s factory configuration. Tumblers are supplied from the factory for operation on Natural Gas or L.P. Gas in the countries of GB/IE/PT/ES/IT/GR/ LU/CH. To install machines in any other country, or on any other gas, requires some level of modification.
Machines configured for Natural Gas (regulator/ governor) may be converted to L.P. Gas (not regulated/ no governor) with block-open kit, Part No. M400763.
Serial plates are configured for GB/IE/PT/ES/IT/GR/ LU/CH.
Code Gas Type Group
Orifice Part No.
Natural Gas H 20 8.9 050 075 3.7 3.6 2 3 M401000 M401014
L.P. Gas B/P 30 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
Natural Gas E 20 8.9 050 075 3.7 3.6 2 3 M401000 M401014
LL 25 12.6 050 075 3.7 3.6 2 3 M401000 M401014
L.P. Gas B/P 30 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
B/P 50 28.5 050 075 2.1 2.0 2 3 M401003 M400999
Natural Gas L 25 12.6 050 075 3.7 3.6 2 3 M401000 M401014
L.P. Gas B/P 30 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
Natural Gas E+ 20/25 No Governor 050 075 3.0 2.9 2 3 M401017
BE/FR*
L.P. Gas + 28/37 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
Natural Gas H 20 8.9 050 075 3.7 3.6 2 3 M401000 M401014
L.P. Gas + 28/37 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
Natural Gas H 20 8.9 050 075 3.7 3.6 2 3 M401000 M401014
L.P. Gas B/P 50 28.5 050 075 2.1 2.0 2 3 M401003 M400999
CY/IS/MT L.P. Gas B/P 30 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Code Gas Type Group
Orifice Part No.
Natural Gas H 25 8.9 050 075 3.7 3.6 2 3 M401000 M401014
L.P. Gas B/P 30 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
Natural Gas H 20 8.9 050 075 3.7 3.6 2 3 M401000 M401014
L.P. Gas 3P 37 No Governor 050 075 2.1 2.0 2 3 M401003 M400999
Burner orifice information at 0-600 meters (0-2000 feet) altitude. N/A = Part no longer available.
* For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace burner orifices. ** For L.P. Gas, Group B/P with 50 mbar supply pressure, convert using Natural Gas model, M411334 regulator spring kit and burner orifices.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Proper sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Exhaust ducts must be assembled so the interior surfaces are smooth to prevent the accumulation of lint.
A drying tumbler produces combustible lint. To reduce the risk of fire, the tumbler must be exhausted to the outdoors.
DO NOT use plastic or thin foil flexible ducts. Use exhaust ducts made of sheet metal or other noncombustible material. Use duct tape or pop-rivets on all seams and joints.
W057 To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building.
Verify that old ducts are thoroughly cleaned out before installing new tumbler.
A tumbler is forced air exhausted and requires provisions for make-up air to replace the air exhausted by the tumbler.
050 928 cm2 (144 in2)
075 1258 cm2 (195 in2)
Make-up air openings with louvers will restrict airflow. The opening must be increased to compensate for area taken up by louvers.
If it is necessary to duct make-up air to the tumbler(s), increase the area of the ductwork by 25% to compensate for any restriction in air movement.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Model Opening

To reduce the risk of electrical shock, de-energize the electrical circuit being connected to the tumbler before making any electrical connections. All electrical connections should be made by a qualified electrician. Never attempt to connect a live circuit.
W002 To reduce the risk of fire and electric shock, check with a qualified serviceman for proper grounding procedures. Improper connection of the equipment grounding conductor may result in a risk of electric shock.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
W068 To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “High Leg” or “Stinger Leg” to a single phase machine. On a three phase machine, if there is a “High Leg” or “Stinger Leg” it should be connected to L3.
All OPL (non-vend) models are factory-equipped with an emergency stop button on the front panel.
In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the appropriate ground location.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

Thermal Oil Prep
Obtain specific steam service pipe sizes from the steam system supplier or a qualified steam fitter.
It is the responsibility of the customer to install appropriate coil and heating system for thermal oil prep models. Alliance Laundry Systems, LLC. is not responsible for the performance or safety of the customer installed thermal oil system. To ensure proper operation, refer to the Specifications and Dimensions section for the BTU input of equivalent steam models. Thermal oil systems that do not deliver appropriate BTUs will dry slower. For solenoid valve wiring connections, refer to the Wiring Diagram supplied with tumbler.
All system components must have a 8.6 bar (125 psig) working pressure. Shut-off valves must be installed upstream of the steam solenoid valve and downstream of each steam trap so components can be isolated for maintenance or emergency purposes.
All components (solenoid valve, traps) must be supported to minimize loads on the tumbler steam coil connections.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT


1 Supply 8 457 mm (18 in.) Drop 2 305 mm (12 in.) Riser 9 Solenoid Valve (Supplied with machine) 3 Shut-Off Valve 10 Steam Bonnet 4 Condensate Return Line from Supply Line 11 Flexible Line 5 Return 12 Union 6 Check Valve 13 Trap with Built-In Strainer 7 Vacuum Breaker (Optional)
Steam Pressure bar (PSI) Minimum Pipe Diameter Steam Trap Size* (Pounds Condensate/Hour)
5.3 - 6.9 (80-100) 3/4 in. NPT 160
* Based on 100 PSI.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Table 2

W076 To reduce the risk of serious injury, allow cylinder to stop before cleaning lint screen.
Operating Instructions
All OPL tumblers are factory-equipped with an emergency stop button located on the front panel. Refer to Figure 4.
Remove any accumulated lint from the lint screen and compartment. Close panel tightly against tumbler frame and lock panel securely, if applicable.
Open loading door and load cylinder with laundry. DO NOT OVERLOAD.
TMB1666N 1 Emergency Stop Button
Close loading door. Tumbler will not operate with the door open.
To operate emergency stop button:
a. Press red emergency stop button to stop all
action.
b. To restart machine, pull red emergency stop
button out and press START pad or button.
Refer to the various controls in the Control Instructions section, pages 22 - 27, determine appropriate control and then follow the instructions.
The type of fabric being dried will determine the temperature setting. Consult the fabric care label or fabric manufacturer to determine proper temperature setting.
When the cycle is complete, open door and remove the laundry.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT 21 M414884 (EN)

CD, CX and CY Control Suffixes
TO START
HIGH
LOW
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

MT and RT Control Suffixes
TO START
HEAT
HIGH
LOW
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

QT and RQ Control Suffixes





© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

G Models Through Serial No. 0110002231 and H, L, P, S, U and Y Models with OM and RM Control Suffixes
To use a Time Dry or Custom Cycle, refer to the Programming Manual.
ON / SELECT
HIGH
MEDIUM
MED LOW
NO HEAT
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

G Models Starting Serial No. 0707xxxxx and K Models with OM and RM Control Suffixes
To use a Time Dry or Custom Cycle, refer to the Programming Manual.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

MDC Coin and Card Control
SD and SX Control Suffixes
BC, BG, BL, BU, BX and BY Control Suffixes

TMB1492N TMB1963N
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT

The Diagnostic LED or DGN LED is located by the power connector on the ignition control. Refer to Figure 33. The Diagnostic LED will indicate the status of the ignition control. Refer to Table 3.
LED Color Description Orange-Yellow Initialization Green Standby / Normal Operation Red Fault Indication Code
The Diagnostic LED will flash error codes one half second on and one half second off. Error codes are separated by a one second pause before the code is repeated.
Error Code DGN LED status Fault Type
1 Red Ignition Control Internal Failure
2 2 Red Flashes Gas Valve Not Connected
3 3 Red Flashes Ignition/Flame Sense Failure
4 4 Red Flashes Reset Switch is Shorted
5 Slow Red and Green Flashes Low Voltage Detection
6 Fast Red and Orange Flashes Ignition Control is in Reset Delay
TMB2176N 1 Diagnostic (DGN) LED
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Table 3

This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Refer to Figure 34. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Ensuring this product is disposed of correctly will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact the local city office, household waste disposal service, or the source from which the product was purchased. Figure 34
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT 29 M414884 (EN)
What the fault codes shown on the display mean and how to clear them.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.