Installation
50 Pound Capacity 75 Pound Capacity Refer to Page 4 for Model Identification
Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.)
Part No. 70256801R1
August 2007



Installation must conform with local codes or, in the absence of local codes, with:
In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”
In Canada, installation must comply with Standards CSA-B149.1 or Natural Gas and Propane Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.
In Australia, installation must comply with the Australian Gas Association Installation Code for Gas Burning Appliances and Equipment.
MISE EN GARDE
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
POUR VOTRE SÉCURITÉ, les informations de ce guide doivent être respectées afin de réduire les risques d’incendie, d’explosion ou d’éviter les dommages matériels, personnels ou blessures mortelles.
W033R3QU
not use any phone in your building. – Clear the room, building or area of all
électriques ; ne pas utiliser le téléphone des lieux. – Évacuer la pièce, le bâtiment ou la zone
a neighbor’s phone. Follow the gas supplier’s instructions. – If you cannot reach your gas supplier,
call the fire department. • Installation and service must be performed by a qualified installer, service agency or the gas supplier.
de gaz de la maison d’un voisin. Respecter les instructions communiquées par le fournisseur. – Si vous ne pouvez pas joindre le
fournisseur de gaz, appeler le service d’incendie. • L’installation et l’entretien doivent être effectués par un installateur, service d’entretien qualifiés ou par le fournisseur de gaz.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
W052R5QU POUR VOTRE SÉCURITÉ
Ne pas entreposer ou utiliser d’essence ou toutes autres vapeurs et liquides inflammables à proximité de cette unité ou de tout autre appareil.


Information in this manual is applicable to these models:
Wiring Diagram
If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor.
The wiring diagram is located in the literature packet supplied with all non-CE Marked models. On CE Marked models, it is located in the junction box.
For technical assistance, call (920) 748-3121.

When calling or writing for information about your product, be sure to mention model and serial numbers. Model and serial numbers are located on the serial plate as shown.


Introduction

Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
DANGER
Failure to install, maintain, and/or operate this machine according to manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage.
Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.

WARNING
Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive.
Safety Information

To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
This machine is intended for commerical use.
Safety Information


B
D
A
T326I
T326I
Specifications and Dimensions


Specifications and Dimensions

B
T329I
T329I
Models Diameter A B
50CG 50EG 1/2 in. NPT 15.5 in. (394 mm)
65.75 in. (1670 mm)
75CG 75EG 1/2 in. NPT 15.75 in. (400 mm)
65.75 in. (1670 mm)
3/4 in. NPT 15.75 in. (400 mm)
65.75 in. (1670 mm)
Specifications and Dimensions

A
B B
T330I GAS AND STEAM ELECTRIC
T330I
50CG/50EG 50CSH/50CSL 75CG/75EG 75CSH/75CSL DTB634/STB634
(MT/CD) 3 in. (76.2 mm)
(MT/CD) 72 in. (1067 mm)
(OM) 9.5 in. (241 mm)
(OM) 63.5 in. (1613 mm)
50CE/75CE 19 in. (483 mm) 64 in. (1626 mm)
Specifications and Dimensions · Models A B

B
D
T328I T328I
Models Diameter A B C D
50CSH 50CSL 3/4 in. NPT 15.25 in. (387 mm)
72.75 in. (1848 mm)
7.5 in. (190 mm)
64.75 in. (1645 mm)
75CSH 75CSL 3/4 in. NPT 15.25 in. (387 mm)
72.75 in. (1848 mm)
7.5 in. (190 mm)
64.75 in. (1645 mm)
Specifications and Dimensions

Materials Required (Obtain Locally)
Upon delivery, visually inspect the packaging and portions of the product visible through the packaging for shipping damage. If the package or product is damaged, or if signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.
All Models One fused disconnect switch or circuit breaker.
Gas Models One gas shut-off valve for gas service line to each tumbler.
Steam Models One steam shut-off valve for steam
service line to be connected upstream of solenoid steam valve.
Remove the packaging as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.
Two steam shut-off valves for each condensate return line.
Flexible steam hoses with a 125 psig (pounds per square inch gauge) (8.79 kg/sq. cm) working pressure for connecting steam coils. Refer to Figure 15 for sizing and connection configurations.
IMPORTANT: Warranty is void unless tumbler is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed in this manual and with applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.
Two steam traps for steam coil outlet to condensate return line.
Two vacuum breakers for condensate return lines.

A typical tumbler enclosure is shown in Figure 1. Note that the enclosure touches the tumbler top and side panels. Also, note the minimum and maximum dimensions. There may be local codes and ordinances which must be complied with.
The tumbler must be installed on a level floor. Floor covering materials such as carpeting or tile must be removed.
To assure compliance, consult local building code requirements.

The tumbler MUST NOT be installed or stored in an area where it will be exposed to water and/or weather.
To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances.
1 Zero Clearance Permitted for First 4 in. (102 mm) 2 4 in. (102 mm) Maximum Header Thickness 3 12 in. (305 mm) Minimum Clearance Permitted for Remainder 4 Guard 5 Provision for Make-Up Air 6 24 in. (610 mm) Minimum – 36 in. (914 mm) Recommended for Maintenance Purposes 7 Zero Clearance
Installation

Installing Accessory Timing Cam
Remove lint panel door, and unscrew the four shipping bolts (one at each corner). Remove tumbler from skid.
Coin drop tumblers have eight accessory cams in the literature packet. These allow you to change your vending times. Refer to Table 1. Timer motor RPM is printed on the timer motor.
Remove four nuts from the literature packet and screw one fully onto each leveling leg.

Screw the four leveling legs (bolts) back into the level adjusting fittings from the bottom.
Slide tumbler to its permanent location. Adjust the leveling legs until the unit is level within 1/8 inch (32 mm). Tumbler must not rock. Lock leveling legs with nuts previously installed.

Installation · Table 1

T039I
1 Line Up Notch to Clear Ratchet Tooth 2 Lift Gently with Narrow Blade
Installation

The airflow switch operation may be affected by shipping tape still in place, lack of make-up air, or an obstruction in the exhaust duct. These should be checked and the required corrective action taken before attempting to adjust the airflow switch. To adjust the airflow switch refer to Adjustments Section.

The tumbler must not be operated if the airflow switch does not operate properly. Faulty airflow switch operation may cause an explosive gas mixture to collect in the tumbler.
IMPORTANT: Refer to Table 2. The electronic ignition system will attempt to light the gas by sparking for the “trial for ignition” period. If gas does ignite within this period, the ignition control will go into a safety lockout and the valve will no longer open until the control is reset. It may be necessary to reset several times to bleed air out of gas lines. To restart open and close loading door and restart unit.


If the tumbler does not meet ANY of the above requirements, remove tumbler from use. Refer to Removing Tumbler from Service Section.
If lockout condition persists, check that the manual gas shut-off valve is in the ON position and that the gas service is properly connected. If condition still persists, remove tumbler from service.
Installation · Table 2

Once machine is installed, please be sure to complete the following items:
Installation

Models are built in three different configurations:
Serial plates supplied from the factory are configured for one of the three gases for the countries of GB/IE/ PT/ES/IT. This information pertains to situations when the country of use or gas supply is different than that on the serial plate.
General Information
This information is to be used when installing gas tumblers in countries and/or on gases different than the machine’s factory configuration. Tumblers are supplied from the factory for operaton on Natural Gas or L.P. Gas in the countries of GB/IE/PT/ES/IT. To install machines in any other country or on any other gas requires some level of modification.
Table 3, Table 4 and Table 5 describe the different gases that are available in different EU countries, and how the machines need to be configured to operate with those gases. In the EU, there are Natural Gases that do not allow for machine regulation, and L.P. Gases that must be regulated. For L.P. Gas, third family B/P at 50 mbar, order Regulated Natural Gas machines and convert according to tables.
Installation


1 Gas Shut-Off Valve (Ahead of pressure tap) 2 Pressure Tap 3 Gas Shut-Off Valve (Shown in closed position)
How to Convert Gas Valve from Regulated to Unregulated

When converting the tumbler to a different gas or pressure, first verify that the supply inlet pressure is equipped with a pressure regulator (located ahead of the tumbler) that will maintain the gas supply at the inlet pressure specified.
Johnson G96 Gas Valve:
a. Disconnect electrical power from tumbler.
Close gas shut-off valve to tumbler. Refer to Figure 5.
b. Follow instructions in Conversion Kit, Part
No. M400763 (Johnson Part No. Y71AA-5C).
c. Change injector size as required by the
appropriate table according to How to Change Injector (Orifice) Size.
d. Commission tumbler for use.
Installation


1 Burner 7 Nut 2 Gas Valve 8 Anti-Torque Ring 3 Regulator Plate 9 Manifold Pipe 4 Gasket 10 Spud Holder 5 Plate 11 Burner Orifice 6 Regulator Cap
How to Change Injector (Orifice) Size
Johnson G96 Gas Valve – Unscrew spud holder nut near gas valve. Refer to Figure 7. Remove the burner orifice(s) from spud holder. Refer to Figure 6.
Installation


1 Burner Tube Attaching Screws 6 Spud Holder Nut 2 Burner Support Bracket 7 Spud Holder 3 Pressure Tap 8 Pressure Tap (Alternate location) 4 Gas Valve 9 Manometer 5 Gas Valve Flange
How to Adjust Gas Valve Governor/Regulator

Installation

Gas Type GB IE PT ES IT DK NO SE FI DE NL BE FR AT
Inject.
0 Inject. Qty & Part. No.
Inlet Press.
Gvnr./ Regltr.
Inject. Press.
1 2nd family Group H
3.7 mm 2 M401000 20 mbar Yes 8.9 mbar
Nat. Gas
3 2nd family Group L
3.7 mm 2 M401000 25 mbar Yes 12.6 mbar
4 4 2nd family Group E+ 3.0 mm 2 M401017
20.25 mbar No Unreg.
5 3rd family Group
2.1 mm 2 M401003 30 mbar No Unreg.
L.P. Gas
6 6 3rd family Group
2.1 mm 2 M401003 50 mbar Yes 28.5 mbar
7 8 8 3rd family Group 3+ 2.1 mm 2 M401033
28.37 mbar No Unreg.
OPEN – No Approval available.
Special Cases – Regulated Gas Valve may be converted to Unregulated with block-open kit Part No. M400763.

Gas Type GB IE PT ES IT DK NO SE FI DE NL BE FR AT
Inject.
0 Inject. Qty & Part. No.
Inlet Press.
Gvnr./ Regltr.
Inject. Press.
2nd family Group H
Nat. Gas
2nd family Group L
2nd family Group E+
5 3rd family Group
1.8 mm 2 M401018 30 mbar No Unreg.
L.P. Gas
7 8 8 3rd family Group 3+ 1.8 mm 2 M401018
28.37 mbar No Unreg.
OPEN – No Approval available.
Special Cases – Natural Gas not available as a factory order.

Gas Type GB IE PT ES IT DK NO SE FI DE NL BE FR AT
Inject.
0 Inject. Qty & Part. No.
Inlet Press.
Gvnr./ Regltr.
Inject. Press.
1 2nd family Group H
3.6 mm 2 M401014 20 mbar Yes 8.9 mbar
Nat. Gas
3 2nd family Group L
3.6 mm 2 M401014 25 mbar Yes 12.6 mbar
4 4 2nd family Group E+ 2.9 mm 2 M402444
20.25 mbar No Unreg.
5 3rd family Group
2.0 mm 2 M400999 30 mbar No Unreg.
L.P. Gas
6 6 3rd family Group
2.0 mm 2 M400999 50 mbar Yes 28.5 mbar
7 8 8 3rd family Group 3+ 2.0 mm 2 M400999
28.37 mbar No Unreg.
OPEN – No Approval available.
Special Cases – Regulated Gas Valve may be converted to Unregulated with block-open kit Part No. M400763.


Installation

Make-up air openings in rooms containing tumbler(s) and/or gas fired hot water heater or other gravity vented appliances must be increased sufficiently to prevent downdrafts in any of the vents when all tumblers are in operation. Do not locate gravity vented appliances between tumbler(s) and make-up air openings. If it is necessary to duct make-up air to tumbler(s), increase area of ductwork by 25% to compensate for restrictions in airflow.
A drying tumbler produces combustible lint. To reduce the risk of fire, the tumbler must be exhausted to the outdoors.
W057 To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building.
For maximum efficiency and minimum lint accumulation, tumbler air must be exhausted to the outdoors by the shortest possible route.
Proper sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Exhaust ducts must be assembled so the interior surfaces are smooth, so the joints do not permit the accumulation of lint. DO NOT use plastic or thin foil flexible ducts. Use exhaust ducts made of sheet metal or other noncombustible material. Use duct tape on all joints.
Whenever possible, install tumblers along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. Construction must not block the airflow at the rear of the tumbler. Doing so would prevent adequate air supply to the tumbler combustion chamber.
Verify that old ducts are thoroughly cleaned out before installing new tumbler.
Improperly sized or assembled ductwork causes excess back pressure which results in slow drying, lint collecting in the duct, lint blowing into the room, and increased fire hazard.
A tumbler is forced air exhausted and requires provisions for make-up air to replace air exhausted by tumbler. Refer to Table 6.
Exhaust ducts shall be constructed of sheet metal or other noncombustible material. Such ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 0.0195 inches (0.495 mm) thick.
Required Make-Up Air Opening (to the outside) for Each Tumbler
Where the exhaust duct pierces a combustible wall, ceiling, floor or partition an opening having a diameter of 4 inches (102 mm) larger than the diameter of the exhaust duct shall be provided, with the duct centered in the opening. The space around the duct may be sealed with noncombustible material. Refer to Figure 10.
50 Pound 144 in2 (928 cm2)
75 Pound 195 in2 (1258 cm2)
634 250 in2 (1613 cm2)
Make-up air openings with louvers will restrict airflow. The opening must be increased to compensate for area taken up by louvers.
Model Opening · Table 6


For maximum efficiency and performance, it is preferred to exhaust tumbler(s) individually to the outdoors.
8 in. (203 mm) 10 in. (254.0 mm) 12 in. (304.8 mm) 14 in. (355.6 mm) 16 in. (406.4 mm) 18 in. (457.2 mm)
One 90° elbow = 9.3 ft. (2.83 m) One 90° elbow = 11.6 ft. (3.5 m) One 90° elbow = 14 ft. (4.3 m) One 90° elbow = 16 ft. (4.9 m) One 90° elbow = 18.7 ft. (5.7 m) One 90° elbow = 21 ft. (6.4 m)
The exhaust duct must be designed so the static back pressure measured 12 inches (305 mm) from the exhaust outlet does not exceed the maximum allowable pressure specified on the installation sticker on the rear of the tumbler. Static back pressure must be measured with the tumbler running (both pockets on stacked models).
Equivalent Length (feet) = 1.17 x Duct Diameter (inches)
Example: A 12 inch diameter duct’s equivalent length of 14 feet of duct and two 90° elbows is:
The maximum allowable length of venting of the same diameter as the exhaust thimble is 14 feet (4.3 m) and two 90° elbows or equivalent. If the equivalent length of a duct required for an installation exceeds the maximum allowable equivalent length, the diameter of a round duct must be increased by 10% for each additional 20 feet (6.1 meters). Cross section area of a rectangular duct must be increased by 20% for each additional 20 feet (6.1 meters). Refer to Table 7 to determine equivalent venting.
= 14 ft. + 14 ft. + 14 ft. = 42 ft. (12.8 m)
With the tumbler in operation, airflow at any point in the duct should be at least 1200 feet per minute (366 meters per minute) to ensure that lint remains airborne. If 1200 feet per minute cannot be maintained, schedule a regular inspection and cleaning of the ductwork.

Consult your local building code for regulations which may also apply. NOTE: Inside of duct shall be smooth. Do not use sheet metal screws to join sections.
1 No Screen or Cap 2 Wall 3 Clearance per Local Codes 4 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes. 5 Minimum Distance Between Opening and Roof: 36 in. (914 mm).
Exhaust Requirements · Table 7

With the tumbler in operation, airflow at any point in the duct should be at least 1200 feet per minute (366 meters per minute) to ensure that lint remains airborne. If 1200 feet per minute cannot be maintained, schedule a regular inspection and cleaning of the ductwork.
While it is preferable to exhaust tumblers individually to the outdoors, a main collector duct may be used if it is sized according to Figure 12. This illustration indicates minimum diameters, and should be increased if the collector length exceeds 14 feet (4.2 meters) and two 90° elbows. The diameter of a round duct must be increased by 10% for each additional 20 feet (6.1 meters). Cross sectional area of a rectangular or square duct must be increased 20% for each additional 20 feet (6.1 meters). Refer to Table 8 to determine equivalent ducting sizing. The collector duct may be rectangular or square in cross section, as long as the area is not reduced. Provisions MUST be made for lint removal and cleaning of the collector duct.
The collector system must be designed so the static back pressure measured 12 inches (305 mm) from the exhaust outlet does not exceed the maximum allowable pressure specified on the installation sticker on the rear of tumbler. This must be measured with all tumblers vented into the collector operating.
The vent collector system must be designed so the static back pressure measured 12 inches (305 mm) from the exhaust outlet does not exceed the maximum allowable pressure specified on the installation sticker on the rear of tumbler. Static back pressure must be measured with all tumblers vented into the collector operating.
Never connect a tumbler duct at a 90° angle to the collector duct. Refer to Figure 11. Doing so will cause excessive back pressure, resulting in poor performance. Never connect two tumbler exhaust ducts directly across from each other at the point of entry to the collector duct.
Exhaust Requirements · T438i


L K J I H G F E D C B A
T472I 1 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes. 2 Outlet Duct Diameter for One Battery Same as Largest Station Used 3 Outlet Duct Diameter for Two Batteries 4 45° Typical
8 Inch Duct 10 Inch Duct
50, 75 Pound 634
A 10 in. (254 mm) 13 in. (330 mm) 10 in. (254 mm) 15 in. (381 mm)
B 12 in. (305 mm) 17 in. (432 mm) 15 in. (381 mm) 22 in. (559 mm)
C 15 in. (381 mm) 18 in. (457 mm) 18 in. (457 mm) 26 in. (660 mm)
D 17 in. (432 mm) 24 in. (610 mm) 21 in. (533 mm) 30 in. (762 mm)
E 19 in. (483 mm) 27 in. (686 mm) 24 in. (610 mm) 34 in. (864 mm)
F 21 in. (533 mm) 30 in. (762 mm) 26 in. (660 mm) 37 in. (940 mm)
G 23 in. (584 mm) 33 in. (838 mm) 28 in. (711 mm) 40 in. (1016 mm)
H 25 in. (635 mm) 34 in. (864 mm) 30 in. (762 mm) 43 in. (1092 mm)
I 26 in. (660 mm) 37 in. (940 mm) 32 in. (813 mm) 46 in. (1168 mm)
J 27 in. (686 mm) 39 in. (991 mm) 33 in. (838 mm) 47 in. (1194 mm)
K 29 in. (737 mm) 40 in. (1016 mm) 35 in. (889 mm) 50 in. (1270 mm)
L 30 in. (762 mm) 42 in. (1067 mm) 36 in. (914 mm) 51 in. (1295 mm)
Exhaust Requirements · Duct Station · Table 8

Obtain specific gas service pipe size from the gas supplier. Refer to Table 9 for general pipe size.
A dirt and water vapor pipe trap must be furnished and installed. Refer to Figure 13.
To reduce the risk of fire or explosion, DO NOT CONNECT THE GAS LINE TO THE TUMBLER IF THE GAS SERVICE IS NOT THE SAME AS THAT SPECIFIED ON THE TUMBLER SERIAL PLATE! It will first be necessary to convert the gas burner orifice and gas valve. Appropriate conversion kits are available.
Install a 1 inch (25.4 mm) pipe gas loop to maintain equal pressure at all gas connections. Refer to Figure 14.
An in-line pressure regulator may be required on Natural Gas models if the line pressure exceeds 8 water column inches (2.00 kPa) pressure with all gas appliances firing.
To reduce the risk of fire or explosion, if the tumbler is to be connected to Liquefied Petroleum (L.P.) gas, a vent to the outdoors must be provided in the room where the tumbler is installed.
NATURAL GAS service must be supplied at 7.0 ± 1.5 inch water column pressure (1.74 ± 0.37 kPa).
L.P. (Liquefied Petroleum) GAS service must be supplied at 11 ± 0.3 inch water column pressure (2.74 ± 0.07 kPa).
EUROPEAN GASES – The above data for Natural and L.P. Gas does not apply in the EU. Refer to Installing Gas Drying Tumblers in the European Union.
Pressure checks can be made at the shut-off valve. Refer to Figure 13.

Turn on gas and check all pipe connections (internal and external) for gas leaks with a non-corrosive leak detection fluid. Purge air in gas service line by operating the tumblers in the drying mode. If burner does not light and unit goes into lockout, open and close the door and restart. Repeat these steps until burner ignites. Use pipe compound, resistant to actions of L.P. Gas, on all pipe threads.


Do not use an open flame to check for gas leaks! To reduce the risk of explosion or fire check all pipe connections, internal and external, for gas leaks using a non- corrosive leak detection fluid. Check gas connections annually for leakage.
1 Gas Line to Tumbler 2 1/8 in. NPT Plug 3 Gas Supply Piping System 4 Gas “T” Fitting 5 6 in. (152 mm) Minimum Gas Pipe 6 Gas Pipe Cap 7 Dirt and Water Vapor Trap 8 Shut-Off Valve
Gas Requirements

1 Gas Furnace (120,000 Btu/hr) 2 Gas Water Heaters (400,000 Btu/hr each) 3 Gas Space Heaters (70,000 Btu/hr each) 4 19 ft. (5.8 m) 5 25 ft. (7.6 m) 6 Main Regulator 7 Gas Meter 8 Pressure Regulator (If required) 9 Gas Tumblers (120,000 Btu/hr each) 10 Gas Line Pressure Tap 11 1 in. (25.4 mm) Gas Pipe Loop 12 NOTE: Minimum Pipe Size is 1/2 in. (12.7 mm) 13 Shut-Off Valves
Equivalent length = Total length of main gas supply pipe to the far end of the tumblers.
= 25 ft. + 19 ft. (7.6 m + 5.8 m) gas supply pipe = 44 ft. (13.4 m) Total Gas Line Total Btu/hr = The sum of the Btu/hr of all tumblers being fed by the main gas supply pipe. = 9 x 120,000 = 1,080,000 Btu/hr Using Table 9, the main supply pipe diameter should be 2 in. (51 mm).
Gas Requirements

Gas Pipe Size Required for 1000 Btu Natural Gas — 0.64 Specific Gravity at 7 ± 1.5 inch (1.62 ± .37 kPa) Water Column Pressure
25 feet (7.63 m)
50 feet (15.25 m)
75 feet (22.88 m)
100 feet (30.50 m)
125 feet (38.13 m)
150 feet (45.75 m)
Gas Appliances Total Btu/hr.
Based on 0.3 in. Water Column Pressure Drop for Length Given
Sizes shown are in inches (mm)
100,000 120,000 140,000 160,000 180,000 200,000 300,000 400,000 500,000 600,000 700,000 800,000 900,000 1,000,000 1,100,000 1,200,000 1,300,000 1,400,000 1,500,000 1,600,000 1,700,000 1,800,000 1,900,000 2,000,000 2,200,000 2,400,000 2,600,000 2,800,000 3,000,000
.75 (19.05) .75 (19.05) .75 (19.05) .75 (19.05)
.75 (19.05)
1 (25.40) 1 (25.40) 1 (25.40) 1 (25.40) 1 (25.40) 1.25 (31.75) 1.25 (31.75) 1.5 (38.10) 1.5 (38.10) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3.5 (88.90)
1 (25.40) 1 (25.40) 1 (25.40) 1.25 (31.75) 1.25 (31.75) 1.25 (31.75) 1.5 (38.10) 1.5 (38.10) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3.5 (88.90) 3.5 (88.90) 3.5 (88.90)
1 (25.40) 1 (25.40) 1 (25.40) 1.25 (31.75) 1.25 (31.75) 1.25 (31.75) 1.5 (38.10) 1.5 (38.10) 2 (50.80) 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3.5 (88.90) 3.5 (88.90) 3.5 (88.90) 3.5 (88.90) 3.5 (88.90)
1 (25.40) 1 (25.40) 1.25 (31.75) 1.25 (31.75) 1.25 (31.75) 1.5 (38.10) 1.5 (38.10) 2 (50.80) 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3.5 (88.90) 3.5 (88.90) 3.5 (88.90) 3.5 (88.90) 3.5 (88.90) 4 (101.60)
1 (25.40) 1 (25.40) 1 (25.40) 1 (25.40) 1 (25.40) 1.25 (31.75) 1.25 (31.75) 1.5 (38.10) 1.5 (38.10) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20) 3 (76.20)
1 (25.40) 1 (25.40) 1 (25.40) 1.25 (31.75) 1.25 (31.75) 1.5 (38.10) 1.5 (38.10) 1.5 (38.10) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2 (50.80) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50) 2.5 (63.50)
Gas Requirements · Equivalent Length · Table 9

For proper operation at altitudes above 2000 feet (610 meters), the gas orifice size must be reduced to ensure complete combustion. Refer to Table 10 for non-CE Marked models. (For CE Marked models, consult local gas supplier.)
Altitude Orifice New Rate
feet meters No. inches mm Quantity Part Number (Btu/hr)*
Natural Gas 2001-4000 610-1830 30 0.1285 3.3
4001-6000 1831-2440 31 0.1200 3.0 M401017 72,200
6001-10,000 2441-3050 32 0.1160 2.9 M402444 64,600
50EG
L.P. Gas 2001-4000 610-1220 47 0.0785 2.0 M400999 87,400
6001-8000 1831-2440 49 0.0730 1.8 M401018 72,200
8001-10,000 2441-3050 50 0.0700 1.8 M401016 64,600
Natural Gas 2001-4000 610-1830 28 0.1405 3.6
4001-6000 1831-2440 29 0.1360 3.4 M400997 100,800
6001-10,000 2441-3050 30 0.1285 3.3 M401021 91,200
50CG
L.P. Gas 2001-4000 610-1220 44 0.0860 2.2 M401011 110,400
6001-8000 1831-2440 46 0.0810 2.1 M401003 91,200
8001-10,000 2441-3050 47 0.0785 2.0 M400999 81,600
Natural Gas 2001-4000 610-1830 29 0.1360 3.4
4001-6000 1831-2440 30 0.1285 3.3 M401021 138,600
6001-10,000 2441-3050 31 0.1200 3.0 M401017 125,400
75CG
L.P. Gas 2001-4000 610-1220 45 0.0820 2.1 M401027 151,800
6001-8000 1831-2440 47 0.0785 2.0 M400999 125,400
8001-10,000 2441-3050 48 0.0760 1.9 M401001 112,200
Natural Gas 2001-4000 610-1220 23 0.1540 3.9
4001-6000 1221-1830 25 0.1495 3.8 M402997 180,600
6001-8000 1831-2440 27 0.1440 3.7 M400998 163,400
8001-10,000 2441-3050 29 0.1360 3.4 M400997 146,200
L.P. Gas 2001-4000 610-1220 42 0.0935 2.4 M403017 197,800
6001-8000 1831-2440 44 0.0860 2.2 M401011 163,400
8001-10,000 2441-3050 45 0.0820 2.1 M401027 146,200
* Btu/hr derate of 4% per 1000 feet (305 meters) of altitude.
Gas Requirements · Model Gas · Table 10

Obtain specific steam service pipe sizes from steam system supplier or a qualified steam fitter.
Machines require a (constant) 80 to 100 psig (pounds per square inch gauge) (5.62 to 7.03 kg/sq. cm) steam service for optimum operation.
All system components must have a 125 psig (10 bar) working pressure. Shut-off gate valves must be installed upstream of the steam solenoid valve and downstream of each steam trap so components can be isolated for maintenance or emergency purposes.
All components (solenoid valve, traps) must be supported to minimize loads on the tumbler steam coil connections.

WARNING
The steam trap must be installed and the coil outlet connections must be connected to the condensate return lines. The following steps outline the procedure for installing the steam trap and connecting the condensate return lines. Refer to Figure 15 for typical installations.
The flexible steam hoses connecting the coil outlet connections and steam traps must have a minimum of 125 psig (pounds per square inch gauge) (8.79 kg/ sq. cm.) working pressure. A shut-off valve must be installed downstream from each steam trap so the condensate return line can be isolated in event a steam trap requires maintenance.
Each steam trap must be supported so minimum load is exerted on the coil outlet connection.
Steam Requirements


1 Supply 8 18 in. (457 mm) Drop 2 12 in. (305 mm) Riser 9 Solenoid Valve (Supplied with machine) 3 Globe Valve 10 Steam Bonnet 4 Return 11 Check Valve 5 Check Valve 12 Union 6 Condensate Return Line from Supply Line 13 Trap with Built-In Strainer 7 Vacuum Breaker

Steam Requirements · Table 11

This tumbler must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the appropriate ground location.
W002 To reduce the risk of fire and electric shock, check with a qualified serviceman for proper grounding procedures. Improper connection of the equipment grounding conductor may result in a risk of electric shock.
To reduce the risk of electrical shock, de-energize the electrical circuit being connected to the tumbler before making any electrical connections. All electrical connections should be made by a qualified electrician. Never attempt to connect a live circuit.
W068 To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “High Leg” or “Stinger Leg” to a single phase machine. On a three phase machine, if there is a “High Leg” or “Stinger Leg” it should be connected to L3.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Grounding Instructions
NOTE: To ensure protection against shock, this tumbler MUST be electrically grounded in accordance with the local codes or, in the absence of local codes, with the latest edition of the National Electrical Code ANSI/NFPA No. 70. In Canada the electrical connections are to be made in accordance with CSA C22.1 latest edition Canadian Electrical Code or local codes. Electrical work should be done by a qualified electrician.
For CE Marked Models Only:
All OPL (non-vend) models are factory-equipped with an emergency stop button on the front panel.

The following steps outline the procedure for connecting the electrical service to the tumbler.
a. Energize the electrical service (on reversing
tumblers, ensure nonreversing is selected) and momentarily start the tumbler. Check the direction of the cylinder rotation. If the cylinder rotates clockwise (viewed from the front), the phase sequence is correct. If the cylinder rotates counterclockwise, proceed with step b.
b. Disconnect and reverse any two service leads
on the terminal block.

1 Electrical Service (Gas and Steam Models) 2 Electrical Service (Electric Models) 3 Accessory Box 4 Ground Lug (Electric Models) 5 Fuses 6 Ground Screw (Gas and Steam Models Only) 7 Contactor Box
Electrical Requirements

Ferrite Ring Installation
Gas and Steam OPL Micro Control Models Only
Changing the transformer configuration jumper is required if any of the following apply:
The ferrite ring provided in the literature packet must be installed over the power leads during connection of electrical service. The ferrite protects the sensitive electronic controls from destructive electrical disturbances which may be present on power lines to the machine. Failure to properly install the ferrite ring may result in damage to the electronic controls and will void control warranty.
To configure your 208 or 240 Volt tumbler for 208 Volt operation, you must remove the 240 Volt configuration jumper located in the contactor box and replace it with the 208 Volt jumper supplied with the information packet. This must be done prior to supplying power to the machine. Failure to install proper configuration jumper may result in damage to sensitive electronic controls and may void warranty.
To install:
To configure your 380 or 415 Volt tumbler for 415 Volt operation, you must remove the 380 Volt configuration jumper located in the contractor box and replace it with the 415 Volt jumper supplied with the information packet. This must be done prior to supplying power to machine. Failure to install proper configuration jumper may result in damage to sensitive electronic controls and may void warranty.

Electrical Requirements

Refer to Table 12.
Heat Source Serial Plate Voltage
Gas and Steam 120 Volt/60 Hertz/
1 Phase L1, Neutral and ground * 20 Amps 1 12 AWG (3.9 mm2)
Gas and Steam 208 or 240 Volt/
60 Hertz/1 Phase L1, L2, Neutral and ground
* 15 Amps 2 14 AWG (2.6 mm2)
Gas and Steam 230-240 Volt/50 Hertz/
1 Phase L1, Neutral and ground† * 15 Amps 1 14 AWG (2.6 mm2)
Gas and Steam 208 or 240 Volt/
60 Hertz/3 Phase L1, L2, L3, and ground† * 15 Amps 3 14 AWG (2.6 mm2)
Gas and Steam 380 or 415 Volt/
50 Hertz/3 Phase L1, L2, L3 and ground * 15 Amps 3 14 AWG (2.6 mm2)
Gas and Steam 460-480 Volt/60 Hertz/
3 Phase L1, L2, L3 and ground * 15 Amps 3 14 AWG (2.6 mm2)
Electric 240 Volt/50 Hertz/ 1 Phase L1, Neutral and ground 91 Amps 100 Amps 1 2 AWG (43 mm2)
Electric 208 Volt/60 Hertz/ 3 Phase L1, L2, L3 and ground 88 Amps 100 Amps 3 2 AWG (43 mm2)
Electric 240 Volt/60 Hertz/ 3 Phase L1, L2, L3 and ground 78 Amps 90 Amps 3 2 AWG (43 mm2)
Electric 240 Volt/50 Hertz/ 3 Phase L1, L2, L3 and ground 78 Amps 90 Amps 3 2 AWG (27 mm2)
Electric 380 Volt/50 Hertz/ 3 Phase L1, L2, L3 and ground† 50 Amps 60 Amps 3 4 AWG (27 mm2)
Electric 415 Volt/60 Hertz/ 3 Phase L1, L2, L3, and ground† 46 Amps 60 Amps 3 4 AWG (27 mm2)
Electric 480 Volt/60 Hertz/ 3 Phase L1, L2, L3, and ground 38 Amps 50 Amps 3 6 AWG (17 mm2)
*Current Ratings vary slightly depending on model; refer to serial plate. †MT (manual timer)/CD (rotary coin drop) Models may require a Neutral conductor. Consult wiring diagram.

Refer to Table 13.
Heat Source Serial Plate Voltage
Gas and Steam 120 Volt/60 Hertz/
1 Phase L1, Neutral and ground * 20 Amps 1 12 AWG (3.9 mm2)
Gas and Steam 208 or 240 Volt/
60 Hertz/1 Phase L1, L2, Neutral and ground
* 15 Amps 2 14 AWG (2.6 mm2)
Gas and Steam 230-240 Volt/50 Hertz/
1 Phase L1, Neutral and ground† * 15 Amps 1 14 AWG (2.6 mm2)
Gas and Steam 208 or 240 Volt/
60 Hertz/3 Phase L1, L2, L3, and ground† * 15 Amps 3 14 AWG (2.6 mm2)
Gas and Steam 380 or 415 Volt/
50 Hertz/3 Phase L1, L2, L3 and ground * 15 Amps 3 14 AWG (2.6 mm2)
Gas and Steam 460-480 Volt/60 Hertz/
3 Phase L1, L2, L3 and ground * 15 Amps 3 14 AWG (2.6 mm2)
Electric 208 Volt/60 Hertz/ 3 Phase L1, L2, L3 and ground 88 Amps 100 Amps 3 2 AWG (43 mm2)
Electric 240 Volt/60 Hertz/ 3 Phase L1, L2, L3 and ground 78 Amps 90 Amps 3 2 AWG (43 mm2)
Electric 240 Volt/50 Hertz/ 3 Phase L1, L2, L3 and ground 78 Amps 90 Amps 3 2 AWG (27 mm2)
Electric 380 Volt/50 Hertz/ 3 Phase L1, L2, L3 and ground† 50 Amps 60 Amps 3 4 AWG (27 mm2)
Electric 415 Volt/60 Hertz/ 3 Phase L1, L2, L3, and ground† 46 Amps 60 Amps 3 4 AWG (27 mm2)
Electric 480 Volt/60 Hertz/ 3 Phase L1, L2, L3, and ground 38 Amps 50 Amps 3 6 AWG (17 mm2)
*Current Ratings vary slightly depending on model; refer to serial plate. †MT (manual timer)/CD (rotary coin drop) Models may require a Neutral conductor. Consult wiring diagram.


Air shutter adjustments will vary from location to location and will depend on the vent system, number of units installed, make-up air and line gas pressure. Opening the shutter increases the amount of primary air supplied to the burner while closing the shutter decreases the primary air supply. Adjust air shutter as follows:
Refer to Figure 18.

The airflow switch operation is controlled by the counterweight position in the shaft. Moving the counterweight either increases or decreases airflow switch sensitivity. The counterweight should be adjusted so the disc moves away from the cabinet when the lint panel is opened 1.5 inches (38.1 mm) with a full load. Adjust the airflow switch as follows:
WARNING
To reduce the risk of fire, airflow switch operation may be affected by a clogged lint screen, lack of make-up air, obstructions in the vertical recirculation stack or in the customer installed main or collector ducts. These conditions must be checked and necessary corrections made before adjusting airflow switch. Always adjust airflow at installation.
The airflow switch (located on the rear of tumbler, Figure 19) is set at the factory for proper operation. However, if there is a problem with the switch, it should be adjusted as follows:
Adjustments


T041I 1 Airflow Switch 2 Mounting Bracket 3 Rear Panel of Tumbler 4 Switch Adjusting Screws 5 Screw 6 Switch Lever 7 Spring Clip 8 Counterweight 9 Disc 10 Vane Lever Arm
Adjustments


The door switch should be adjusted so the cylinder stops when door is opened 2 inches (51 mm), plus or minus 1/4 inch (6 mm). This switch is a normally open switch and is closed by the interlock rod when the door is closed. If adjustment is required, refer to Figure 20 and proceed as follows:
T048I 1 Switch Arm 2 Adjusting Screws 3 Door Safety Switch 4 Tab 5 Interlock Rod 6 Switch Bracket
Adjustments

Loading door switch is factory adjusted to turn off when the door is opened a maximum of 3 inches (76 mm). If adjustment is needed, refer to Figure 21 and follow these steps:
T495I 1 Loading Door Switch 2 Screw Slot 3 Switch Coupler
Adjustments

The door strike must be adjusted to have sufficient tension to hold loading door closed against force of load tumbling against it. There is proper adjustment when 8 to 15 pounds (35.6-66.7 N) pull is required to open door.
If adjustment is required, refer to Figure 22 and proceeds as follows:
To adjust, open door, loosen acorn nut and turn door strike screw in or out as required. Tighten acorn nut.
T048I 1 Door Strike 2 Acorn Nut 3 Door Latch
Adjustments

WARNING
Refer to Figure 23.
Refer to Figure 24.
There is proper tension when the chain can be depressed approximately 1/2 inch (13 mm) by applying light thumb pressure at a point midway between the cylinder and drive sprocket.
IMPORTANT: After a tumbler has been in operation over an extended period of time, a “High Point” will develop on the cylinder drive sprocket through use and wear. Turn the sprocket manually with drive chain in place until this “high point” is at the top center. The “high point” can be found by noticing increased chain tensionwhile slowly rotating the cylinder sprocket manually.
Adjustments

There is proper tension when each cylinder belt can be depressed approximately 3/16 inch (5 mm) by applying light thumb pressure (approximately 5 pounds) at a point midway between the sheave and the idler.
Refer to Figure 25. There is proper tension when the drive V-belt can be depressed approximately 1/2 inch (13 mm) by applying light thumb pressure at a point midway between the sheave and motor pulley.
Refer to Figure 26. There is proper tension when the drive belt can be depressed approximately 1/2 inch (13 mm) by applying light thumb pressure (approximately 5 pounds [2.2 kg]) at a point midway between the sheave and motor pulley.
Adjustments


1 Sheave 8 Guide Rail 2 Cylinder Drive Chain 9 Guide Rail Washer 3 Cylinder Sprocket 10 Ground Wire (Green) 4 Idler Sprocket 11 Motor Pulley 5 Jam Nut 12 V-Belt 6 Drive Sprocket 13 1/2 in. (13 mm) Deflection 7 Idler Housing 14 Belt Adjusting Bolt and Nut
Adjustments


1 Motor Pulley 7 1/2 in. (13 mm) Deflection 2 Cylinder Motor 8 Guide Rail 3 Locknut 9 Idler Housing 4 Adjusting Bolt 10 Idler Housing Attaching Bolt and Nut 5 Cylinder Sprocket 11 Sheave 6 Cylinder Drive Chain 12 Poly V-Belt
Adjustments


T234I 1 Poly V-Belt (Self-Adjusting) 2 Idler Housing Bolts (2) 3 Adjusting Bolt 4 Drive V-Belt 5 Idler Housing Assembly
Adjustments


T322I 1 Locking Bolt 2 Adjusting Nut 3 Adjusting Screw 4 Cylinder Belts 5 Guide Rail 6 Idler Housing Bolts (2) 7 Adjusting Bolt (Not shown) 8 Drive Belt
Adjustments