Instructions for Drying
Tumblers
JCB30CE, JCB30CG, JCB30CSH, JCB30CSL, JCB30WE, JCB30XG, SCB30CE, SCB30CG, SCB30CSH, SCB30CSL, SCB30WE and SCB30XG
JC50CE, JC50CG, JC50CSH, JC50EG, JCB50CE, JCB50CG, JCB50CSH, JCB50EG, SC50CE, SC50CG, SC50CSH, SC50EG, SCB50CE, SCB50CG,
75 Pound (34 Kg) Capacity
JC75CE, JC75CG, JC75CSH, JCB75CE, JCB75CG, JCB75CSH, SC75CE,
SC75CG, SC75CSH, SCB75CE, SCB75CG and SCB75CSH
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. (If this tumbler changes ownership, be sure this manual accompanies the tumbler).
A copy of the operating instruction must remain with the tumbler after installation.
To locate the servicer nearest you, call (414) 748-3121.
Part No. M412616 1/95
Manufactured By: Speed Queen Company P.O. Box 990 Ripon, WI 54971-0990 U.S.A.
Distributed By:



FAILURE TO INSTALL, MAINTAIN, AND/OR OPERATE THIS MACHINE ACCORDING TO MANUFACTURER’S INSTRUCTIONS MAY RESULT IN CONDITIONS WHICH CAN PRODUCE SERIOUS INJURY, DEATH AND/OR PROPERTY DAMAGE.
Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.
aWARNING To reduce the risk of fire, electrical shock, serious injury or death to persons do not operate the tumbler if it does not perform according to these instructions. Immediately disconnect electrical service, shut off gas supply and contact an authorized service representative. Service and repairs are to be performed by authorized service representatives only.
aWARNING To reduce the risk of fire, electrical shock, serious injury or death to persons when using the tumbler unit, follow these basic precautions:
· Read all instructions before using tumbler. · DO NOT tamper with controls. · DO NOT bypass any safety devices. · Always follow the fabric care instructions supplied by the garment manufacturer. · Remove laundry immediately after the tumbler stops. · DO NOT reach into tumbler if cylinder is revolving.
aWARNING To avoid creating any flammable vapors which may explode, ignite or cause corrosive damage, DO NOT dry the following materials:
· Articles that have been cleaned in, soaked in, washed in or spotted with gasoline, dry cleaning solvents or other flammable/explosive substances. · Plastics or articles containing foam rubber or similarly textured rubberlike materials. · Articles that have traces of flammable substances like cooking oil, machine, oil, flammable chemicals or thinner. · Articles containing wax or cleaning chemicals. · Fiberglass curtains or draperies (unless the label says it can be done).
aWARNING To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
1 M412616 © Copyright 1994. All Rights Reserved.
aWARNING

To reduce the risk of fire, electric shock, serious injury or death to persons when using your dryer, follow these basic precautions:
The following warning labels will be found on the drying tumbler:
A clothes dryer produces combustible lint. TUMBLER MUST BE EXHAUSTED OUTDOORS.
Do not touch rotating parts.

Do not touch surface until it has cooled.
Do not operate without guards in place.
Disconnect electrical power before servicing.
To reduce risk of accumulating unsafe concentrations of combustion gases, tumbler MUST BE EXHAUSTED OUTDOORS.




When writing for information on any tumbler, be sure to mention
When writing for information on any tumbler, be sure to mention model and serial numbers. The model and serial numbers will be found on the nameplate as shown on the rear of tumbler or underneath the door hinge.
If replacement parts are required, contact the source from whom you purchased your tumbler or, contact the Ripon Service Parts Center, P.O. Box 990, Ripon, Wisconsin 54971-0990, for the name and address of the nearest authorized parts distributor.

SECTION I Roughing-In Dimensions and Specifications 30 Pound (13 kg) Narrow Cabinet Gas Tumbler
SIDE PANEL 8.59 cm (3-3/8")
67.95 cm (26-3/4")
8.59 cm (3-3/8")
TOP VIEW OF EXHAUST
3.81 cm (1-1/2")
81.76 cm (32-3/16")
113.98 cm (44-7/8")
DISCONNECT
SWITCH
15.24 cm (6") DIAMETER
AIR FLOW
SWITCH
GAS CONNECTION AND SHUT OFF
183.52 cm (72-1/4")
to nearest Combustible Material Top —
12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
71.12 cm (28")



SWITCH

15.24 cm (6") DIAMETER
EXHAUST
to nearest Combustible Material Top —
12" (30.5 cm) Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.


to nearest Combustible Material Top — 12" (30.5 cm)
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
71.5 cm (28-1/4")
3.81 cm (1-1/2")
81.75 cm (32-3/16")
114 cm (44-7/8") 118.6 cm (46-11/16")
GAS CONNECTION
AND SHUT OFF VALVE AIR FLOW SWITCH
ELECTRICAL JUNCTION BOX
20.3 cm (8") DIAMETER EXHAUST DUCT
183.5 cm (72-1/4")
THIMBLE CONNECTION (Energy Saver
157.8 cm (62-1/8")
140.7 cm (55-3/8")
11.3 cm (4-7/16")
20.3 cm (8") DIAMETER EXHAUST DUCT
AIR FLOW SWITCH (Energy Saver Models)
55.6 cm (21-7/8")


to nearest Combustible Material Top — 12" (30.5 cm)
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
71.7 cm (28-1/4")
3.81 cm (1-1/2")
81.75 cm (32-3/16")
SWITCH
ELECTRICAL JUNCTION BOX
183.5 cm (72-1/2")
11.3 cm (4-7/16")
20.3 cm (8") DIAMETER EXHAUST DUCT
55.6 cm (21-7/8")
SWITCH
T267IE3B
114 cm (44-7/8") · 80 cm (31-1/2")

Cylinder: 30" x 30" (76.2 x 76.2 cm) perforated galvanized steel with three baffles; 30 pounds (13.6 kg) dry weight (cotton load)
Electrical Requirements: 230 Volt, 50 Hertz, 1 Phase, 90 Amp (see nameplate for voltage 230 Volt, 50 Hertz, 3 Phase, 54 Amp of your tumbler) 380 Volt, 50 Hertz, 3 Phase, 33 Amp 415 Volt, 50 Hertz, 3 Phase, 30 Amp

to nearest Combustible Material Top — 12" (30.5 cm)
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
71.75 cm (28-1/4")
3.81 cm (1-1/2")
81.75 cm (32-3/16")
114 cm (44-7/8") (High Pressure Models)
114.4 cm (45-1/32") (Low Pressure Models)
35.6 cm (14")
19.05 cm (7-1/2") 1.9 cm (3/4") I.D. STEAM
1.9 cm (3/4") I.D. STEAM OUTLET
183.5 cm (72-1/4")
174.6 cm (68-3/4")
155.6 cm (61-1/4")
11.27 cm (4-7/16")
20.3 cm (8") DIAMETER EXHAUST DUCT
55.56 cm (21-7/8")
80 cm (31-1/2")

Cylinder: 30" x 30" (76.2 x 76.2 cm) perforated galvanized steel with three baffles; 30 pounds dry weight (13.6 kg) (cotton load)
Motor: High Pressure (4 coils) ¹⁄₂ H.P. Low Pressure (4 coils) ³⁄₄ H.P.
Boiler Horsepower: 4 coil High Pressure – 3.7 Bhp (123,950 BTU/hr., 58 kg/hr, 31,235 kCal/hr.) 4 coil Low Pressure – 2.6 Bhp (87,100 BTU/hr., 40 kg/hr, 21,949 kCal/hr.)
Electrical Requirements: Low Pressure: (see nameplate for 230 Volt, 50 Hertz, 1 Phase, 8 Amp voltage of tumbler) 380 Volt, 50 Hertz, 3 Phase, 3 Amp 415 Volt, 50 Hertz, 3 Phase, 3 Amp
High Pressure:
230 Volt, 50 Hertz, 1 Phase, 4 Amp 380-415 Volt, 50 Hertz, 3 Phase, 2 Amp
Air Flow: Low Pressure — 600 C.F.M. at 0.5 W.C. (283 liters/sec. at 1.25 mBar) High Pressure — 600 C.F.M. at 0.5 W.C. (283 liters/sec. at 1.25 mBar)

to nearest Combustible Material Top — 12" (30.5 cm)
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
71.75 cm (28-1/4")
3.81 cm (1-1/2")
81.75 cm (32-3/16")
119.4 cm (47")
GAS CONNECTION
SWITCH
AND SHUT OFF
VALVE AIR FLOW SWITCH
20.3 cm (8") DIAMETER EXHAUST DUCT
THIMBLE CONNECTION (Energy Saver
194.6 cm (76-5/8")
146.37 cm (57-5/8")
13.65 cm (5-3/8")
20.3 cm (8") DIAMETER EXHAUST DUCT
AIR FLOW
T269IE3B
98.1 cm (38-5/8")

Cylinder: 37" x 30" (94 cm x 76.2 cm) perforated galvanized steel with four baffles; 50 pounds (22.7 kg) dry weight (cotton load)
Gas Consumption: Energy Saver Models — 95,000 BTU per hour (100.2 MJ/hr.) Standard Models — 120,000 BTU per hour (126.6 MJ/hr.)
Types of Gas: Factory equipped with Natural/Mixed Gas (6-1/2 ± 1-1/2 inch water column line pressure) (1.62 ± .37 kPa); or Liquefied Petroleum gas (11 ± .3" water column line pressure) (2.74 ± .07 kPa)
Gas Connection: 1/2 inch (12.7 mm) N.P.T.
Air Flow: Energy Saver Models — 390 C.F.M. at 0.5" W.C. (185 liters/sec. at 1.25 mBar) Standard Models — 600 C.F.M. at 0.5" W.C. (284 liters/sec. at 1.25 mBar)
Calorific Value: Natural Gas — 8900 kCal/m3 (37.2 MJ/m3) L.P. Gas — 22,250 kCal/m3 (93.1 MJ/m3)
STEAM
GAS ELECTRIC
HIGH PRESSURE LOW PRESSURE
50 LB. FAN 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/2 H.P.
CYLINDER 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/3 H.P.

DISCONNECT
SWITCH
CYLINDER
MOTOR
20.3 cm (8") DIAMETER EXHAUST THIMBLE
194.6 cm (76-5/8")
146.4 cm (57-5/8")
20.3 cm (8") DIAMETER
THIMBLE CONNECTION
AIRFLOW
SWITCH
13.65 cm (5-3/8")
98.1 cm (38-5/8")
CONNECTOR (Energy Saver · Gas Models) · 34 cm (13-3/8")

to nearest Combustible Material Top — 12" (30.5 cm)
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
71.75 cm (28-1/4")
3.81 cm (1-1/2")
81.75 cm (32-3/16")
119.4 cm (47") DISCONNECT
ELECTRICAL JUNCTION BOX 20.3 cm (8") DIAMETER EXHAUST DUCT
194.6 cm (76-5/8")
13.65 cm (5-3/8")
SWITCH
98.1 cm (38-5/8")
34 cm (13-3/8")

Cylinder: 37" x 30" (94 x 76.2 cm) perforated galvanized steel with four baffles; 50 pounds (22.7 kg) dry weight (cotton load)
Electrical Requirements: 230 Volt, 50 Hertz, 1 Phase, 90 Amp (see nameplate for voltage 230 Volt, 50 Hertz, 3 Phase, 78 Amp of your tumbler) 380 Volt, 50 Hertz, 3 Phase, 48 Amp 415 Volt, 50 Hertz, 3 Phase, 45 Amp
STEAM
GAS ELECTRIC
HIGH PRESSURE LOW PRESSURE
50 LB. FAN 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/2 H.P.
CYLINDER 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/3 H.P.

DISCONNECT
SWITCH
CYLINDER
MOTOR
194.6 cm (76-5/8")
20.3 cm (8") DIAMETER
THIMBLE CONNECTION
AIRFLOW
SWITCH
13.65 cm (5-3/8")
98.1 cm (38-5/8")
34 cm (13-3/8")

203.2 cm (80") (6 Coil)
71.75 cm (28-1/4")
3.81 cm (1-1/2")
81.75 cm (32-3/16")
119.4 cm (47")
38.7 cm (15-1/4") 19.05 cm (7-1/2")
1.9 cm (3/4") I.D. STEAM INLET
200 cm (78-3/4") (6 Coil)
1.9 cm (3/4") I.D. STEAM OUTLET
184.8 cm (72-3/4") (4 Coil)
164.5 cm (64-3/4")
13.65 cm (5-3/8")
20.3 cm (8") DIAMETER EXHAUST DUCT
98.1 cm (38-5/8")
34 cm (13-3/8")

Cylinder: 37" x 30" (94 x 76.2 cm) perforated galvanized steel with four baffles; 50 pounds (22.7 kg) dry weight (cotton load)
Motor: High Pressure Steam — 1/2 H.P. (Nonreversing Models) Low Pressure Steam — 3/4 H.P. Both motors are lifetime lubricated, internal overload protected (See below for reversing models.)
(154,100 BTU/hr, 72.1 kg/hr, 38,833 kCal/nr.) Low Pressure Steam (4 Coil) — 3.00 BHP
(134,000 BTU/hr, 62.7 kg/hr, 33,768 kCal/hr.)
Electrical Requirements: Low Pressure (see nameplate for voltage 230 Volt, 50 Hertz, 1 Phase, 7.0 Amp of your tumbler)
High Pressure 230 Volt, 50 Hertz, 1 Phase, 7.0 Amp 380 Volt, 50 Hertz, 3 Phase, 3.0 Amp 415 Volt, 50 Hertz, 3 Phase, 2.5 Amp
Air Flow: Low Pressure — 950 C.F.M. at 0.5" W.C. (449 liters/sec. at 1.25 mBar) High Pressure — 900 C.F.M. at 0.5" W.C. (426 liters/sec. at 1.25 mBar)
Net Weight: 4 Coil Tumbler — 565 pounds (257 kg) (approximate) 6 Coil Tumbler — 580 pounds (263 kg) (approximate)
STEAM
GAS ELECTRIC
HIGH PRESSURE LOW PRESSURE
50 LB. FAN 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/2 H.P.
CYLINDER 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/3 H.P.

71.75 cm (28-1/4")
3.81 cm (1-1/2")
134.6 cm (53")
ELECTRICAL JUNCTION BOX
to nearest Combustible Material Top — 12" (30.5 cm)
194.6 cm (76-5/8")
AND SHUT OFF VALVE
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
13.65 cm (5-3/8")
20.3 cm (8") DIAMETER EXHAUST DUCT
Minimum recommended for service access. Sides — 0" Permitted.
THIMBLE CONNECTION (Standard Models) AIR FLOW
98.1 cm (38-5/8")
97 cm (38-3/16") · 167 cm (65-3/4") · 34 cm (13-3/8")

ELECTRICAL JUNCTION BOX
SWITCH
CYLINDER
MOTOR
194.6 cm (76-5/8")
20.3 cm (8") DIAMETER
THIMBLE CONNECTION
AIRFLOW
SWITCH
13.65 cm (5-3/8")
98.1 cm (38-5/8")
34 cm (13-3/8")

Cylinder: 37" x 36" (94 x 91.4 cm) perforated galvanized steel cylinder with four baffles; 75 pounds (34.1 kg) dry weight (cotton load)
Electrical Requirements Nonreversing Models: 230 Volt, 50 Hertz, 1 Phase, 9.0 Amp
Types of Gas: Factory equipped with Natural/Mixed gas (6-1/2 A 1-1/2 inch water column line pressure) (1.62 A .37 kPa); or Liquefied Petroleum gas (11.0 A .3 inch water column line pressure) (2.74 A .07 kPa)
Gas Connection: 1/2 inch (12.7 mm) N.P.T.
Calorific Value: Natural Gas — 8900 kCal/m3 (37.2 MJ/m3) L.P. Gas — 22250 kCal/m3 (93.1 MJ/m3)
STEAM
GAS ELECTRIC
HIGH PRESSURE LOW PRESSURE
75 LB. FAN 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/2 H.P.
CYLINDER 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/3 H.P.

to nearest Combustible Material Top — 12" (30.5 cm)
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
71.75 cm (28-1/4")
3.81 cm (1-1/2")
134.6 cm (53")
ELECTRICAL JUNCTION BOX
194.6 cm (76-5/8")
20.3 cm (8") DIAMETER EXHAUST DUCT
13.65 cm (5-3/8")
AIR FLOW
SWITCH
98.1 cm (38-5/8")
97 cm (38-3/16") · 34 cm (13-3/8")

ELECTRICAL JUNCTION BOX
SWITCH
CYLINDER
MOTOR
194.6 cm (76-5/8")
20.3 cm (8") DIAMETER
THIMBLE CONNECTION
AIRFLOW
SWITCH
13.65 cm (5-3/8")
98.1 cm (38-5/8")
34 cm (13-3/8")

Cylinder: 3 7" x 36" (94 x 91.4 cm) perforated galvanized steel with four baffles; 75 pounds (34.1 kg) dry weight (cotton load)
Electrical Requirements: 230 Volt, 50 Hertz, 3 Phase, 77 Amps (See nameplate 380 Volt, 50 Hertz, 3 Phase, 50 Amps for voltage of 415 Volt, 50 Hertz, 3 Phase, 45 Amps your tumbler)
STEAM
GAS ELECTRIC
HIGH PRESSURE LOW PRESSURE
75 LB. FAN 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/2 H.P.
CYLINDER 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/3 H.P.


to nearest Combustible Material Top — 12" (30.5 cm)
Minimum. 0" permitted for first 4" (10.2 cm) along front of machine. Back — 0" - 24" (61 cm)
Minimum recommended for service access. Sides — 0" Permitted.
T274IE3B

Cylinder: 37" x 36" (94 x 91.4 cm) perforated galvanized steel with four baffles; 75 pounds (34.1 kg) dry weight (cotton load)
Motor: High Pressure Steam — 3/4 H.P. (Non-reversing models) Low Pressure Steam — 3/4 H.P. Both motors are lifetime lubricated, internal overload protected. (See below for reversing models.)
Boiler High Pressure Steam (6 Coil) — 4.60 BPH Horsepower: (154,100 BTU/hr., 72.1 kg/hr., 38,833 kCal/hr.)
Low Pressure Steam (4 Coil) — 4.00 BHP
(134,000 BTU/hr., 62.7 kg/hr., 33,768 kCal/hr.)
Electrical Requirements: Low Pressure — 230 Volt, 50 Hertz, 1 Phase, 8.5 Amp (See nameplate for voltage of your tumbler) High Pressure — 230 Volt, 50 Hertz, 1 Phase, 9.0 Amp
Air Flow: Low Pressure — 950 C.F.M. at 0.5" W.C. (449 liters/sec at 1.25 mBar) High Pressure — 900 C.F.M. at 0.5" W.C. (425 liters/sec at 1.25 mBar)
STEAM
GAS ELECTRIC
HIGH PRESSURE LOW PRESSURE
75 LB. FAN 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/2 H.P.
CYLINDER 1/3 H.P. 1/3 H.P. 1/3 H.P. 1/3 H.P.

RECEIVING INSPECTION
Upon delivery, visually inspect crate carton and parts for any visible shipping damage. If crate, carton or cover are damaged or signs of possible damage are evident, have carrier note condition on shipping papers before shipping receipt is signed, or advise carrier of condition as soon as it is discovered.
Advise carrier of any damaged or missing articles as soon as possible. A written claim should be filed with carrier immediately if articles are damaged or missing.
Remove crate and protective cover as soon as possible and check items listed on packing list.
Construction must not block airflow at top rear of tumbler. Doing so would prevent adequate air supply to tumbler’s combustion chamber.
Drying tumbler may be installed on any level floor capable of supporting 100 pounds per square foot (488 kg/m2). Floor covering materials such as carpeting or tile should be removed.
For maximum efficiency and minimum lint accumulation, tumbler air must be exhausted to outdoors by shortest possible route.
Whenever possible, tumbler should be installed along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed.

Proper sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Do not install elbows with a radius less than shown in table below. Exhaust ducts must be assembled so interior surfaces are smooth to reduce accumulation of lint. Do not use sheet metal screws to join vent sections. Improperly sized or assembled ductwork causes excess back pressure which results in slow drying, lint collecting in duct, lint blowing back into room, and increased fire hazard.
With tumbler in operation, airflow at any point in duct must be at least 1200 feet (366 m) per minute to insure that lint remains airborne.
Exhaust ducts shall be constructed of sheet metal or other noncombustible material. Such ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 0.0195 inches (0.495 mm) thick.
Collector duct may be rectangular in cross section, as long as area is not reduced. Provisions should be made for lint removal and cleaning of collector duct.
Where exhaust duct pierces a combustible wall or ceiling, an opening having a diameter of 4 inches (10.2 cm) larger than diameter of exhaust duct shall be provided, with duct centered in opening. When ducts pass through walls, ceilings, floors or partitions, space around the duct shall be sealed with non- combustible material. See Figures 1, 2 and 3.
Collector duct must be tapered, as shown in Figure 3. Individual tumbler ducts must enter the collector duct at a 45° angle in direction of air flow. Never connect a tumbler duct at a 90° angle to collector duct. Doing so will cause excessive back pressure, resulting in poor performance. Never connect two tumbler exhaust ducts directly across from each other at point of entry to collector duct.
Collector system must be designed so static back pressure measured 12 inches (30.5 cm) from exhaust thimble does not exceed maximum allowable pressure specified on installation sticker on rear of tumbler. Measured with all tumblers running that are vented into collector.
Maximum allowable length of venting is 14 feet (4.3 m) and two 90° elbows or equivalent. If equivalent length of a duct required for an installation exceeds maximum allowable equivalent length, diameter of a round duct must be increased by 10% for each additional 20 feet (6.1 m). Cross section area of a rectangular duct must be increased by 20% for each additional 20 feet (6.1 m). Table below shows how to determine equivalent venting:
A tumbler is forced air exhausted and requires provisions for make-up air to replace the air exhausted by tumbler.
Manufacturer’s recommended make-up air opening for each tumbler is 144 square inches (928 sq. cm) for 30 and 50 pound tumblers and 195 square inches (1258 sq. cm) for 75 pound tumblers. At a minimum, tumblers must have at least 1 in2 (2.54 cm2) of opening for every 1000 BTU/hr (252 Kcal/hr) of input rating for proper combustion.
EQUIVALENT LENGTH OF
STRAIGHT DUCT
6" (15.2 cm) 8" (20.3 cm) 10" (25.4 cm) 12" (30.5 cm)
One 90° elbow = 7' (2.1 m) One 90° elbow = 9.3' (2.83 m) One 90° elbow = 11.6' (3.5 m) One 90° elbow = 14' (4.3 m)
BTU/hr (30,240 Kcal) requires 120 in2 (774 cm2) of free opening.
Equivalent Length (feet) (m) = 1.17 x Duct Diameter (inches) (cm)
Protective louvers in opening to outdoors can reduce air movement by approximately 40%. Opening must compensate for area taken up by louvers.
Make-up air openings for a room containing tumbler(s) and/or gas fired hot water heater or other gravity vented appliances must be increased sufficiently to prevent downdrafts in any vents when all tumblers are in operation. Do not locate gravity vented appliances between tumbler(s) and make-up air openings. If it is necessary to duct make-up air to tumbler(s), increase area of work by 25% to compensate for any restriction in air movement.
equivalent length of 14 feet (4.3 m) of duct and two 90° elbows is:
= 14 feet (4.3 m) + (2) 90° elbows = 14 feet (4.3 m) + 7 feet (2.1 m) + 7 feet (2.1 m) = 28 feet (8.5 m)
Equivalent length

WARNING WARNING WARNING WARNING WARNING
Solvent gases and vapors from dry cleaning machines create acids when drawn through the heater of a drying tumbler. These acids are corrosive to the drying tumbler as well as to the laundry load being dried. Be sure make-up air is free of solvent gases and vapors.
To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumbler air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building.
If the dry cleaning machines are in the same area as the tumbler, then the tumbler make-up air must come from a source free of solvent gases and vapors.
FOR BEST PERFORMANCE Provide an individual exhaust duct for each tumbler. Do not install a hot water heater in room containing tumblers. It is better to have the water heater in a separate room with a separate air inlet.
T075IE3A
ROOF 30" (76.2 cm)
WALL
REMOVABLE STRIP OF PANEL IN FRAMING WALL TO PERMIT REMOVAL OF TUMBLER FROM FRAMING WALL
36 INCHES (91.4 cm) RECOMMENDED
BULKHEAD
SERVICE AREA
24 INCHES (61.0 cm) MINIMUM
T108IE3B
TWO TUMBLERS
CONSULT YOUR LOCAL BUILDING CODE FOR REGULATIONS WHICH MAY ALSO APPLY
THREE TUMBLERS


WALL
A L K J I H G F E D C B
2" (5.1 cm) MINIMUM
T056IE3B
OR CAP
AIR OUT
MINIMUM DIAMETER
MINIMUM DIAMETER
DUCT STATION
DUCT STATION
*GAS ELECTRIC STEAM *GAS ELECTRIC STEAM
A 9" (22.9 cm) 10" (25.4 cm) G 23" (58.4 cm) 26" (66 cm)
B 12" (30.5 cm) 14" (35.6 cm) H 25" (63.5 cm) 28" (71.1 cm)
C 15" (38.1 cm) 17" (43.2 cm) I 26" (66 cm) 30" (76.2 cm)
D 17" (43.2 cm) 20" (50.8 cm) J 27" (68.6 cm) 31" (78 cm)
E 19" (48.3 cm) 22" (55.9 cm) K 29" (73.9 cm) 33" (83.8 cm)
F 21" (53.3 cm) 24" (61 cm) L 30" (76.2 cm) 34" (86.4 cm)
45˚


Heat Source Electrical Specs Wires Required and Terminal Block Connection
Electric 230-50-3 L1 L2 L3 Ground to PE Busbar
Electric 380-50-3 L1 L2 L3 Ground to PE Busbar
Electric 415-50-3 L1 L2 L3 Ground to PE Busbar

240V, 1 Phase, 50 Hz. 120V, 1 Phase, 30 Hz.
Minimum Wire Size 14 AWG (2.081 mm²) 14 AWG (2.081 mm²)

240V 50 Hz. 1 Ph 240V 50 Hz. 3 Ph 380V 50 Hz. 3 Ph 415V 50 Hz. 3 Ph
Amp Rating 91 Amp 55 Amp 34 Amp 31 Amp
Circuit Breaker 100 Amp 60 Amp 40 Amp 35 Amp
Minimum Wire Size 2 AWG (33.63 mm²) 6 AWG (13.32 mm²) 8 AWG (8.366 mm²) 8 AWG (8.366 mm²)
Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to PE Busbar.

To reduce the risk of fire and electric shock, check with a qualified serviceman for proper grounding procedures. Improper connection of the equipment grounding conductor can result in a risk of electric shock.
To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.


Heat Source Electrical Specs Wires Required and Terminal Block Connection
Gas & Steam 230/50/1 L1 L2 Ground to PE Busbar
Electric 380/50/3 L1 L2 L3 Ground to PE Busbar
Electric 415/50/3 L1 L2 L3 Ground to PE Busbar
Steam 380/50/3 L1 L2 L3 Ground to PE Busbar

240 V, 1 Phase, 50 Hz. 380 V, 3 Phase, 50 Hz.
Minimum Wire Size 14 AWG (2.081 mm²) 14 AWG (2.081 mm²)

240 V, 1 Ph, 50 Hz. 240 V, 3 Ph, 50 Hz. 380 V, 3 Ph, 50 Hz. 415 V, 3 Ph, 50 Hz.
Minimum Wire Size 2 AWG (33.63 mm²) 6 AWG (13.32 mm²) 8 AWG (8.366 mm²) 8 AWG (8.366 mm²)
AMP Rating 90 Amp 54 Amp 33 Amp 30 Amp
Circuit Breaker 100 Amp 60 Amp 40 Amp 35 Amp

LOW PRESSURE STEAM DRYING TUMBLERS
240 V, 1 Phase 50 Hz.
Minimum Wire Size 16 AWG (1.309 mm²)
Circuit Breaker 20 AMP
Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to PE Busbar.
To reduce the risk of fire and electric shock, check with a qualified serviceman for proper grounding procedures. Improper connection of the equipment grounding conductor may result in a risk of electric shock.
To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.
Poles 2


Heat Source Electrical Specs Wires Required and Terminal Block Connection
Gas & Steam 230/50/1 L1 L2 Ground to PE Busbar
Steam 380-415/50/3 L1 L2 L3 Ground to PE Busbar
Electric 380-415/50/3 L1 L2 L3 Ground to PE Busbar
Gas & Steam 230/50/1 L1 L2 Ground to PE Busbar
Gas & Steam 380-415/50/3 L1 L2 L3 Ground to PE Busbar
Electric 230/50/3 L1 L2 L3 Ground to PE Busbar
Electric 380-415/50/3 L1 L2 L3 Ground to PE Busbar

208V / 240 V 1 Phase, 50 Hz. 208 / 240 V 3 Phase, 50 Hz. 380 / 415 V 3 Phase, 50 Hz.
Minimum Wire Size 14 AWG (2.081 mm²) 14 AWG (2.081 mm²) 14 AWG (2.081 mm²)

240 V, 3 Phase 50 Hz. 380 V, 3 Phase 50 Hz. 415 V, 3 Phase 50 Hz.
Minimum Wire Size 3 AWG (26.67 mm²) 6 AWG (13.32 mm²) 6 AWG (13.32 mm²)

LOW PRESSURE STEAM DRYING TUMBLERS
240 V 1 Phase, 50 Hz.
Minimum Wire Size 14 AWG (2.081 mm²)
Circuit Breaker 15 AMP
Drying tumbler must be grounded. In event of malfunction or breakdown, grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to the PE Busbar.
WARNING To reduce the risk of fire and electric shock, check with a qualified service technician for proper grounding procedures. Improper connection of the equipment grounding conductor can result in a risk of electric shock.
Poles 2


Heat Source Electrical Specs Wires Required and Terminal Block Connection
Gas & Steam 230/50/1 L1 L2 Ground to PE Busbar
Electric 208-230/50-60/3 L1 L2 L3 Ground to PE Busbar
Electric 380/50/3 L1 L2 L3 Ground to PE Busbar
Electric 415/50/3 L1 L2 L3 Ground to PE Busbar
Steam 380/50/3 L1 L2 L3 Ground to PE Busbar

208V / 240 V 1 Phase, 50 Hz. 208 / 240 V 3 Phase, 50 Hz. 380 / 415 V 3 Phase, 50 Hz.
Minimum Wire Size 14 AWG (2.081 mm²) 14 AWG (2.081 mm²) 14 AWG (2.081 mm²)

380 V, 3 Ph, 50 Hz. 415 V, 3 Ph, 50 Hz.
Minimum Wire Size 6 AWG (13.32 mm²) 6 AWG (13.32 mm²)
GROUNDING INSTRUCTIONS Drying tumbler must be grounded. In event of malfunction or breakdown. Grounding will reduce risk of electric shock by providing a path of least resistance for electric current. Drying tumbler must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with circuit conductors and connected to PE Busbar.

To reduce the risk of fire and electric shock, check with a qualified service technician for proper ground procedures. Improper connection of the equipment grounding conductor may result in risk of electric shock.
To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “Stinger Leg” to a single phase machine.



All electrical connections should be made by a qualified electrician.
To reduce the risk of electrical shock, de-energize the electrical circuit being connected to the tumbler before mak- ing any electrical connections. Never attempt to connect a live circuit.
Use the following steps to connect electrical service to the tumbler:

breaker. b. Turn “off” disconnect switch on tumbler and
open junction box. c. Insert conduit-encased leads through
one of the knockout holes in junction box. d. Connect wire leads to disconnect switch.
1 Phase Units: Connect one lead to top left connection point. Connect other lead to top right connection point.
3 Phase Units: Connect one lead to each connection point.
e. Connect a ground wire to PE Busbar,
Figure 19, in junction box.
a. Energize electrical service and momentarily
start tumbler. Check direction of the cylinder rotation. If cylinder rotates clockwise (viewed from front), phase sequence is correct. If cylinder rotates counterclockwise, proceed with step “b”. b. Disconnect and reverse any two leads at
connections.
switch.

Tumbler may be removed from skid before moving to installation location or moved while still attached to skid. Remove tumbler from skid by unscrewing four shipping capscrews (one at each corner) and remove tumbler from skid. Lint panel door will have to be removed in order to remove two front capscrews.
Screw four leveling legs back into level adjusting fittings from top. Slide tumbler to its permanent location and level. Keep tumbler as close to floor as possible. All four legs must rest firmly on floor so weight of tumbler is evenly distributed. Tumbler must not rock.
Each tumbler should be leveled within ¹⁄₈ inch (3.2 mm) from front to rear, and ¹⁄₈ inch (3.2 mm) from side to side. Check front to rear level by rotating clothes cylinder until one rib is at bottom, then place a
level on bottom rib. Side to side level should be checked by placing a level on front and rear of top panel.
To reduce the risk of fire or explosion, if the tumbler is to be connected to Liquefied Petroleum (L.P.) gas, a vent to the outdoors must be provided in the room where the tumbler is installed.
Size of gas service pipe is dependent upon many variables (lengths, tees, etc.). Specific pipe size information should be obtained from gas supplier. Refer to table in Figure 22 for general pipe size data.
It is important that equal gas pressure be maintained at all tumbler gas connections. This can best be done by installing a one inch pipe gas loop as shown in Figures 20 and 21.

MAIN REGULATOR
TUMBLERS
GAS SHUT-OFF
VALVES
GAS LINE PRESSURE TAP
ONE INCH
GAS METER
(2.54 cm)
PRESSURE REGULATOR
tumbler is 1/2" (1.27 cm)
An in-line pressure regulator may be required on Natural Gas models if the line pressure exceeds eight water column inches (2.00 kPa) pressure with all gas appliances firing.

1 2 3 4 5 6 7 8 9
SAMPLE CALCULATIONS: Equivalent Length = Total length of main gas supply pipe from the gas meter to the far end of the tumbler dryers. = 25' + 19' (7.6 m + 5.8 m) gas supply pipe. = 44' (13.4 m) Total Gas Liner
Total BTU/HR = The sum of the BTU/HR. of all tumblers being fed by the main gas supply pipe. = 9 x 75,000 = 675,000 BTU/HR.
Using the table in Figure 22, the main supply pipe diameter should be 2" (5.08 cm).
(If required)

GAS PIPE SIZE REQUIRED FOR 1,000 BTU NATURAL GAS — .64 SPECIFIC GRAVITY
AT 6½ ± 1½ INCH WATER COLUMN PRESSURE (1.62 ± .37 kPa)
25 FT. (7.63 m)
50 FT. (15.25 m)
150 FT. (45.75 m) 75 FT. (22.88 m)
125 FT. (38.13 m) 100 FT. (30.50 m)
TOTAL BTU/HR. (Kcal/hr)
BASED ON 0.3" WATER COLUMN (0.75 mBar) PRESSURE DROP FOR LENGTH GIVEN
³⁄₄" (1.905cm)
³⁄₄" (1.905cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
³⁄₄" (1.905cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
³⁄₄" (1.905cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1¹⁄₄" (3.18cm)
³⁄₄" (1.905cm)
1" (2.54cm)
1" (2.54cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1" (2.54cm)
1" (2.54cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1¹⁄₂" (3.81cm)
1" (2.54cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1¹⁄₂" (3.81cm)
1¹⁄₂" (3.81cm)
1¹⁄₂" (3.81cm)
1¹⁄₄" (3.18cm)
1¹⁄₄" (3.18cm)
1¹⁄₂" (3.81cm)
1¹⁄₂" (3.81cm)
1¹⁄₂" (3.81cm)
2" (5.08cm)
1¹⁄₄" (3.18cm)
1¹⁄₂" (3.81cm)
1¹⁄₂" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
1¹⁄₂" (3.81cm)
1¹⁄₂" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
1¹⁄₂" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
1¹⁄₂" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2" (5.08cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2" (5.08cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
2" (5.08cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
2¹⁄₂” (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
2¹⁄₂" (6.35cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3¹⁄₂" (8.89cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
2¹⁄₂" (6.35cm)
3" (7.62cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
3¹⁄₂" (8.89cm)
4" (10.16cm)

Before connecting gas piping to tumbler, make certain gas service is same as that specified on nameplate (near gas connection), Page 5.
Purge air and sediment from gas service line before connecting it loosely to tumbler. Purge remaining air until odor of gas is detected, then tighten connection. Use pipe compound, resistant to actions of L.P. gas, on all pipe threads.
NATURAL GAS service must be supplied at 6¹⁄₂ ± 1¹⁄₂ inch water column pressure (1.62 ± .37 kPa).
WARNING Check all pipe connections, internal and external, for gas leaks using a soapy solution. To reduce the risk of explosion or fire, DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS! Gas connections should be checked annually for leakage.
L.P. GAS service must be supplied at 11 ± .3 inch water column pressure (2.74 ± .07 kPa).
If gas service is not same as that specified, DO NOT CONNECT THE GAS LINE TO TUMBLER! It will first be necessary to convert gas burner orifice and gas valve.
The tumbler and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).
The tumbler must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig (3.45 kPa).

To reduce the risk of serious injury, install lockable doors to prevent public access to rear of tumblers.
A typical tumbler enclosure is shown in Figure 23. Note that enclosure does touch tumbler top and side panels. Note, too, minimum and maximum dimensions. Be aware that there may be local codes and ordinances which must be complied with.
12" (30.5 cm) MINIMUM CLEARANCE
4" (10.16 cm) MAXIMUM
PROVISION
FOR MAKE-UP
AIR
T038IE3B
24" (61 cm) MINIMUM 36" (91.4 cm) RECOMMENDED
FOR MAINTENANCE
PURPOSES

information should be obtained from the steam system supplier or a qualified steam fitter. Size of steam service pipe is dependent upon many variables (length, tees, high pressure system, low pressure system, etc.) Specific pipe size
INSTALLING STEAM TRAP AND MAKING CONDENSATE RETURN CONNECTIONS
Steam trap must be installed and coil outlet connections must be connected to condensate return lines. The following steps outline the procedure for installing steam trap and connecting condensate return lines. See Figure 24 for a typical installation.
High pressure machines require a (constant) 80 to 100 psig (5.62 to 7.03 kg/sq. cm) steam service for optimum operation. Low pressure machines require a (constant) 10 to 15 psig (.70 to 1.05 kg/sq. cm) steam service for optimum operation. The following steps outline procedure for installing steam solenoid valve and connecting steam service.
a. Connect a flexible hose to each steam coil outlet,
Figure 24. b. Install a strainer to the ends of each flexible hose. c. Install a steam trap to each strainer.
a. Install a manual shut-off gate valve in condensate
return line after steam trap for each coil.
b. Connect steam solenoid valve to related steam
coil inlet connection with nipples, flex hoses, unions, tee and pressure relief valve. See Figure 24 for a typical installation.
d. Install a gate shut-off valve to each steam trap. e. Connect to condensate return lines.
c. Install a gate shut-off valve in steam supply
line, Figure 24. Connect shut-off gate valve outlet to solenoid steam valve inlet connection.
The flexible steam hoses connecting the coil outlet connections and steam traps must have a minimum of 125 psig (pounds per square inch gauge) (8.79 kg/sq. cm.) working pressure. A shutoff gate valve must be installed downstream from each steam trap so the condensate return line can be isolated in event a steam trap requires maintenance.
The flexible steam hoses connecting the solenoid steam valve to the coil inlets must have a 125 psig (pounds per square inch gauge) (8.79 kg/sq. cm) working pressure. A shut-off gate valve must be installed upstream from the solenoid steam valve. This way, steam can be shut off for maintenance purposes, or in the event the hose ruptures.
Each steam trap must be supported so minimum load is exerted on the coil outlet connection.
The steam solenoid valve must be supported so minimum load is exerted on the steam coil inlet connections.
aWARNING · aWARNING




during first three seconds ignition control will “lockout” causing gas valve to close and a red button on ignition control to illuminate.
To reset ignition system , open access door and press red button on ignition control. Close and lock access door, verify that gas shut-off valve is in the “on” position and return to step three.
NOTE: Ignition control circuitry will verify airflow switch, located on rear of tumbler, is open before starting cylinder motor. Once cylinder motor is started, air flowing through tumbler will cause airflow switch to close. Tumbler will purge air from tumbler for 18 seconds. Ignition will start by a three second release of gas from gas valve and sparking of ignitor. If ignition does not occur


No. of Pins in Cam
Cams that allow other timer increments are available through your distributor.
To figure time increments, use this formula: Timer Motor Speed (60) divided by number of pins on cam = Cycle Length (minutes). Cams are available with 1 to 12 pins.
Example: 60 ÷ 5 (Pin cam) = 12 minute cycle.
TOOTH
LIFT GENTLY WITH NARROW
BLADE
T039IE1A
Cycle Length (Minutes) · 10 12 15

10.Check air flow switch operation by opening lint panel. Heating systems should shut off when lint panel is opened approximately 6" (15.24 cm) with a full load.
Coin Operated Tumbler
Tumbler comes equipped with Electronic Control. Electronic Control gives owner a variety of programming options. To learn how to use Electronic Control, consult supplemental manual.


Air shutter adjustments will vary from location to location and will depend on vent system, number of units installed, make-up air and line gas pressure. Opening shutter increases amount of primary air supplied to burner while closing shutter decreases primary air supply. Adjust air shutter as follows:
AIR FLOW SWITCH (Gas and Electric Models, see Figure 30)
Air flow switch is set at factory for proper operation. Steam models do not have an air flow switch. However, if there is a problem with airflow switch, it should be adjusted as follows:
INSUFFICIENT
NO AIR FLOW
AIR FLOW
T047SE3A T048SE3A T049SE3A
AIR SHUTTER
AIR SHUTTER
AIR SHUTTER
ADJUSTING
ADJUSTING
ADJUSTING
SCREWS
SCREWS
SCREWS

Electric Models: If switch remains open, or pops open and closed during cycle, heating system will shut off. Cylinder and fan will continue to operate even though air flow switch is malfunctioning.
Counterweight should be adjusted so air flow will force disc away from cabinet when lint panel is opened 6 inches (15.24 cm) with a full load. Adjust air flow switch as follows:
Gas Models: If switch remains open, entire unit will shut down when Push-to-start button is released. Once tumbler starts and continues to run, a loss of air flow, air flow switch jams or a bouncing air flow switch will shut entire tumbler down.

To reduce the risk of fire, air flow switch operation may be affected by a clogged lint screen, lack of make-up air, obstructions in the vertical recirculation stack or in the customer installed main or collector ducts. These conditions must be checked and necessary corrections made before adjusting air flow switch. Always adjust air flow at installation.
Air flow switch operation is controlled by counter- weight position on shaft. Moving counterweight either increases or decreases air flow switch sensitivity.


CYLINDER DOOR STRIKE
Loading door switch turns off tumbler any time loading door is opened. To adjust loading door switch, follow these steps:
The door strike must be adjusted to have sufficient tension to hold loading door closed against force of load tumbling against it. Proper adjustment is when 8 to 15 pounds (35.6 N - 66.7 N) pull is required to open door.
To adjust, open door, loosen jamnut and turn door strike screw in or out as required. Retighten jamnut.
rotate switch coupler COUNTERCLOCKWISE until it stops. c. Tighten lower screw on switch coupler. d. Return to step 1 to verify loading door switch
operation.
NUT
LOADING
DOOR LATCH
DOOR SWITCH
SWITCH COUPLER
T048IE1A
T275IE1A


To reduce the risk of serious injury or death, disconnect power to the tumbler before performing this operation.
Proper tension is when belt can be depressed approximately ¹⁄₂ inch (1.27 cm) by applying light thumb pressure at a point midway between the sheave and motor pulley.

To reduce the risk of serious injury or death, guard MUST be installed on rear of tumbler after belt adjustment is made.


DAILY
THERMOSTAT SENSING PROBE
LINT SCREEN
T046IE3A
MONTHLY