EN
Source Technologies logo
Official user manual

Source Technologies 410

16 pages·942 KB·Indoor Furnishings·PDF·ENDEFRITNLJA
Source Technologies 410
Table of Contents 13 sections Declaration of conformity · Source Four CE guidelines · Basic luminaire · Luminaire information · … ShowHide
Page 1 of the Source Technologies 410 user manual — Production Dates: September 2004 - Present
Page 1 · click to enlarge
Page 1
Source Technologies 410 diagram (page 1)
Fig. 1

CE User Manual

Production Dates: September 2004 - Present

Copyright © 2007 Electronic Theatre Controls, Inc.

All Rights reserved. Product information and specifications subject to change.

Part Number7060M1210-06.01 Rev A
ReleasedAugust 2007
Page 2 of the Source Technologies 410 user manual
Page 2 · click to enlarge
Page 2

T a b l e o f C o n t e n t s

Declaration of conformity 1

Source Four CE guidelines 2

Basic luminaire 3

Luminaire information 4 Colour frame holder 5 Replacing the HPL lamp 6 Centering lamp and adjusting the field 7 Focusing the beam 7 Shaping the beam 8 Rotating the barrel assembly 9 Adjusting the yoke position 9 Cleaning lens and reflector 10 Portable appliance test (PAT) guidelines 12

ETC®, Emphasis®, Expression®, Insight™, Imagine™, Focus™, Express™, Unison®, Obsession® II, ETCNet2™, EDMX™, Source Four®, Revolution®, Sensor®, and WYSILink™ are either registered trademarks or trademarks of Electronic Theatre Controls, Inc. in the United States and other countries.

All other trademarks, both marked and not marked, are the property of their respective owners.

Page 3 of the Source Technologies 410 user manual — English Declaration of conformity
Page 3 · click to enlarge
Page 3

English Declaration of conformity

We, Electronic Theatre Controls, Europe Ltd. declare under sole responsibility that the product:

Product nameSource Four CE
Product type/modelSource Four CE series (405, 410, 414, 419, 426, 436, 450, 470, 490)
Lotn/a
Batch/Serial numbern/a
Item numbersone of each model

to which this declaration relates in conformity with the following standards:

EN60598-1:2000 Luminaires, General requirements and tests

EN60598-2-17:1990 Specification for luminaires for stage lighting, television, film, and photographic studios (outside and indoor) - equiv. BS 4533- 102.17:1990

following the provisions of EU LV Directive(s) 73/23/EEC

London, United Kingdom Mr. Adam Bennette

(Place of issue) (Name of authorised person)

Source Technologies 410 — English Declaration of conformity diagram (page 3)
Fig. 2 · English Declaration of conformity

(Date of issue) (signature of authorised person)

Electronic Theatre Controls, Ltd. Registered office: Unit 26-28 Victoria Industrial Estate, Grant Thornton House Victoria Road, London W3 6UU U.K. Melton St., London NW1 28W, England Telephone (+44) (0)20 8896 1000 Registered in England No. 3057796 Fax (+44) (0)20 8896 2000 VAT No. 6629487 90

Page 4 of the Source Technologies 410 user manual — Source Four CE guidelines
Page 4 · click to enlarge
Page 4

Source Four CE guidelines

The Source Four CE is intended for professional use only. Read the entire User Guide before using equipment.

W A R N I N G : Please note the following safety precautions.

  • Do not mount the Source Four CE on or near a flammable surface.
  • Use the Source Four CE in dry locations only, where humidity does not exceed 90 percent.
  • The luminaire is for indoor use only and is not intended for outdoor use.
  • For temporary installations, mount and support the Source Four CE only by the primary suspension yoke holes. Suspend the luminaire from a hook clamp or a stand mount, using a securely tightened steel bolt (up to Ø 12 mm), flat washer and locking washer.
  • In addition to primary suspension, attach a safety cable (ETC part #7060A1022) or chain to the secondary suspension point on the Source Four CE.
  • If the external cable is damaged, it shall be replaced by ETC or our service agents.
  • Always hang the Source Four CE with the colour frame held securely behind the retaining clip.
  • Always replace the lamp if it becomes damaged or thermally deformed.
  • Disconnect the unit from power before all cleaning and maintenance.
  • The Source Four CE is suitable for indoor use with a maximum ambient temperature: T a =45 C
  • Maximum exterior surface temperature: T max =217ºC
  • A multilingual label sheet is included with this manual. Affix the label of the appropriate language over the existing warning label on the extension yoke. Do not cover ETC trademark or CE mark.
  • The Source Four CE is equipped with a safety screen that covers the lens to prevent injury from broken glass due to lamp failure. Do not remove this safety screen.
  • Keep the luminaire at least 0.8 meters away from any lit surface. Lighted objects at this distance or greater will not exceed 90ºC temperature from projected light.

0.8m

Page 5 of the Source Technologies 410 user manual — English Basic luminaire
Page 5 · click to enlarge
Page 5

English Basic luminaire

Source Technologies 410 — English Basic luminaire diagram (page 5)
Fig. 3 · English Basic luminaire

Safety screen (19°, 26°, 36° and 50° only) Colour frame holder

W A R N I N G : Please note the following safety warnings before use:

Do not mount the luminaire on or near combustible surfaces.

Do not operate the luminaire without a lens installed.

Always hang the luminaire with the colour frame retaining clip in the locked position.

Earth continuity cable · Gel retainer · clip

Page 6 of the Source Technologies 410 user manual — HPL lamp table
Page 6 · click to enlarge
Page 6

Luminaire information

Wiring and power information

A plug of at least 2.5 amp (220/240V) rating should be attached to the luminaire’s mains lead. The wires in the mains lead are 1.55mm2 each and coloured in accordance with the following code:

Green and YellowEarth
BlueNeutral
BrownLive

W A R N I N G : This luminaire must be earthed.

Current rating120V/5 amp maximum 240V/2.5 amp maximum
Operating frequency50/60 Hz

HPL lamp table

C A U T I O N : Do not use lamps other than the HPL in Source Four fixtures. Use of lamps other than HPL will void your warranty.

Lamp codeWattsVoltsInitial LumenColour temp.Average rated life HPL 750/23075023019,7503,200°K300 hours HPL 750/230X75023015,6003,050°K1500 hours HPL 575/23057523014,9003,200°K400 hours HPL 575/230X57523011,7803,050°K1500 hours HPL 375/2303752307,2503,000°K1000 hours HPL 750/224075024019,7503,200°K300 hours HPL 750/240X75024015,6003,050°K1500 hours HPL 575/24057524014,9003,050°K400 hours HPL 575/240X57524011,7803,050°K1500 hours HPL 375/240X37524019,7503,000°K1000 hours

t 180°c

Page 7 of the Source Technologies 410 user manual — Colour frame holder
Page 7 · click to enlarge
Page 7

Colour frame holder

Retaining clip in the locked position

The colour frame holder is equipped with a spring-loaded retaining clip that prevents colour frames and accessories from falling out. See Figure 2.

W A R N I N G : Make sure all colour frame accessories are locked in position with the retaining clip before hanging the Source Four luminaire.

1. Release the retaining clip by pushing it sideways while gently pulling backwards.
2. Insert the colour frame.
3. Lock the retaining clip by pushing sideways while gently pushing forward.

N o t e : The performance of saturated colours may be less than desirable in any theatrical lighting luminaire, especially when equipped with a 750w lamp. For best results, always use high-quality colour media rated for high-temperature use.

ETC’s optional Conical Gel Extender, part # 7060A1048, will provide maximum colour media life. For 14° lens tubes, use part # PSF1029. Gel Extenders are not recommended for 70° and 90° lens tubes due to the extremely wide-angle beam.

A variety of heat shield products is also available from many colour media manufacturers. Follow the manufacturer’s instructions for the use of these products.

For maximum gel life with specific lens tubes, refer to the tables below.

Source Technologies 410 — Colour frame holder diagram (page 7)
Fig. 4 · Colour frame holder
Lens TubeSoft Focus Back (Lamp “flat”) (LSharp Focus amp “cosine”)Soft Focus Forward (Lamp “peak”)Soft Focus Forward (Lamp “cosine”) 14°worsegoodbestgood 70°bestgoodworsegood 90°bestgoodgoodworse 19°worsebetterbetternot applicable 26°worsebetterbetternot applicable 36°betterbetterworsenot applicable 50°worsebetterbetternot applicable
ED Lens TubeSoft Focus Back (Lamp “flat” (LSharp Focus amp “cosine”)Soft Focus Forward (Lamp “peak”)Soft Focus Forward (Lamp “cosine”) 19°worsebetterbetternot applicable 26°betterbetterworsenot applicable 36°betterbetterworsenot applicable 50°betterbetterworsenot applicable
Source Technologies 410 — Colour frame holder diagram (page 7)
Fig. 5 · Colour frame holder
Page 8 of the Source Technologies 410 user manual — Replacing the HPL lamp
Page 8 · click to enlarge
Page 8

Replacing the HPL lamp

HPL lamp Lamp retention

Figure 3 Knurled bolt

A lamp must be installed before you use the luminaire.

N o t e : Verify that the HPL lamp you intend to install is suitable for your facility’s voltage; 115-, 120-, 230-, and 240-volt HPL lamps are available. See HPL lamp table, page 4. Operating HPL lamps above their rated voltage reduces lamp life and can cause premature lamp failure.

W A R N I N G : Let the lamp cool before replacing.

1. Disconnect power to the Source Four luminaire before installing the lamp.
2. Loosen the knurled bolt on the back of the lamp housing and pull the housing out.
3. Holding by the base, remove the HPL lamp from its box.

C A U T I O N : Use caution when installing or replacing any lamp.

When installing/replacing lamp, be sure to point the lamp away from your face and away from others before inserting it firmly into the assembly.

This may prevent injuries if the lamp should break.

Source Technologies 410 — Replacing the HPL lamp diagram (page 8)
Fig. 6 · Replacing the HPL lamp

N o t e : To avoid premature lamp failure, do not touch the lamp glass. If you do, clean it carefully with isopropyl alcohol and a clean lint-free cloth. Allow to dry before operation.

4. Align the flat sides of the lamp base with the retention brackets on either side of the socket as shown in Figure 3 .
5. Push down on the lamp base until the lamp seats firmly. When properly installed, the top of the lamp’s base will be even with he top edges of the retention brackets.

C A U T I O N : Improperly installed lamps cause premature lamp failure and socket problems.

6. Press lamp retaining clip across lamp base to secure.
7. Reinstall the lamp housing by aligning the bolt hole and tightening the knurled bolt.

Lamp retaining clips · brackets · Lamp housing

Page 9 of the Source Technologies 410 user manual — Focusing the beam
Page 9 · click to enlarge
Page 9

Centering lamp and adjusting the field

Source Technologies 410 — Centering lamp and adjusting the field diagram (page 9)
Fig. 7 · Centering lamp and adjusting the field

Inner Knob - peak/flat field adjustment

Source Technologies 410 — Centering lamp and adjusting the field diagram (page 9)
Fig. 8 · Centering lamp and adjusting the field

Hot spot - lamp pulled out too far

Field with hole - lamp pushed in too far

Outer Knob - lamp center adjustment

Figure 4 Figure 5

The two concentric knobs located on the lamp housing allow you to align the lamp and adjust its field. See Figure 4. The outer knob centers the lamp within the reflector. The inner knob adjusts the lamp’s field.

1. Turn on the Source Four CE and aim it at a flat surface. Adjust the barrel to create a hard

edge.

2. Unlock and loosen the outer knob by turning it counterclockwise.
3. Gently move the outer knob from side to side and up and down until the lamp is centered within the reflector.
4. Once the lamp is centered, turn the outer knob clockwise to lock it in place.
5. Finally, turn the inner knob either clockwise or counterclockwise to achieve an optimum flat field. See Figure 5 .

Focusing the beam

Source Technologies 410 — Focusing the beam diagram (page 9)
Fig. 9 · Focusing the beam

Beam focus knob Figure 6

1. Loosen the beam focus knob located under the barrel as shown in Figure 6 .
2. Slide the lens tube forward or backward to achieve the desired beam edge.
3. Once the luminaire is focused, tighten the beam focus knob.

Flat field-best adjustment · Rear lamp housing

Page 10 of the Source Technologies 410 user manual — Drop-In Iris Slot
Page 10 · click to enlarge
Page 10

Shaping the beam

The beam can be shaped using the shutters (see Figure 8), a gobo, an optional drop-in iris, or by rotating the barrel.

Gobo Projection

The gobo holder slot is on the top side of the barrel and in front of the shutters. It accommodates A-size, B-size and glass gobo holders (see Figure 7).

Source Technologies 410 — Gobo Projection diagram (page 10)
Fig. 10 · Gobo Projection

A-Size Gobo holder: holds 7.62 cm diameter gobos B-Size Gobo holder: holds 6.35 cm and 6.98 cm diameter gobos

9.4 cm Figure 7

N o t e : Because the Source Four luminaire aperture is 7.62 cm wide, ETC recommends using A-size gobos for maximum effectiveness.

N o t e : Enhanced Definition Lens Tubes (EDLT) provide for a crisper gobo projection.

Use an optional donut in the accessory holder to enhance gobo projection. Donut diameter range should be 6.35 cm to 6.98 cm.

Drop-In Iris Slot

Source Technologies 410 — Drop-In Iris Slot diagram (page 10)
Fig. 11 · Drop-In Iris Slot

The drop-in iris slot is located on the top of the barrel and in front of the gobo holder slot. It accommodates either a drop-in iris or a motorized gobo device. When the slot is not in use, a small sheet metal cover secured with two Phillips screws prevents light leakage (see Figure 8).

1. Use a Phillips screwdriver to loosen the screws on the drop-in iris slot cover. Do not

remove screws.

2. Slide the cover completely forward to expose the slot.

Shutters

Page 11 of the Source Technologies 410 user manual — Setting the luminaire height within the yoke
Page 11 · click to enlarge
Page 11
3. Insert the iris or motorized gobo device. For an iris, install the flat side toward the shutters and make sure the iris handle extends from the slot.
4. Slide the slot cover back toward the shutters until it meets the iris handle. Leave enough space to move the iris handle.
5. Secure the drop-in iris slot cover by tightening the screws.

Rotating the barrel assembly

Source Technologies 410 — Rotating the barrel assembly diagram (page 11)
Fig. 12 · Rotating the barrel assembly
1. Loosen the barrel rotation knob directly behind the shutters on the underside of the

reflector housing (see Figure 9). Do not remove the barrel rotation knob.

2. Rotate the barrel to the desired position (up to 25° in either direction from the centered position).
3. Once the barrel is positioned, tighten the barrel’s rotation knob to lock it in place.

Adjusting the yoke position

The Source Four CE provides multi-positioning capabilities within its yoke for overall luminaire height and angle.

Setting the luminaire height within the yoke

The Source Four CE has a two-position yoke for modifying the overall height in which the luminaire is mounted (see Figure 10). To change the height position, perform the following steps.

Source Technologies 410 — Setting the luminaire height within the yoke diagram (page 11)
Fig. 13 · Setting the luminaire height within the yoke
1. Remove the yoke locking knobs, washers, and hex bolts from either side of the luminaire.
2. Raise or lower the luminaire to the desired position within the yoke.
3. Reinstall the yoke’s hex bolts, washers, and locking knobs.
4. Tighten the yoke knobs to secure in position.

General use position · Low clearance position

Page 12 of the Source Technologies 410 user manual — Cleaning 5° and 10° polymer lenses
Page 12 · click to enlarge
Page 12
Source Technologies 410 — Cleaning lens and reflector diagram (page 12)
Fig. 14 · Cleaning lens and reflector
1. Loosen the yoke locking knobs (see Figure 11 ). Do not remove them.
2. Tilt the luminaire to the desired position.
3. Tighten the yoke locking knobs to secure in position.

Cleaning lens and reflector

W A R N I N G : Do not use ammonia-based or other harsh commercial cleaners. Clean lenses and reflector only as directed.

Commercially available glass cleaning agents should be avoided as they may contain ammonia, other harsh chemical detergents or abrasive agents. These cleaners may damage the glass surface and the Anti-Reflective coatings. Do not immerse or soak the glass in any cleaning solution.

Replace lenses if they contain visible damage (cracks or deep scratches) that may impair their effectiveness.

Cleaning 14°, 19°, 26°, 36°, 50°, 70°, 90° and all EDLT glass lenses

1. Remove the beam focus knob along with retainer bolt and collar from the barrel (see

Figure 1). Remove the lens tube from the barrel.

N o t e : To clean the inside of lenses, it is necessary to remove the lenses from the lens tube for cleaning. Instruction for removing the lens can be found in the Source Four Assembly Guide available for download at our website: www.etcconnect.com

2. Remove dust with a blast of oil-free air or wipe with a clean, lint-free cloth. Isopropyl alcohol, distilled water or a 50%-50% mixture of each can be used to clean the glass surface.
3. Slide the lens tube back into the barrel with the color frame retaining clip on top. Reinstall the beam focus knob, retainer bolt and collar.

Cleaning 5° and 10° polymer lenses

To quickly clean the lenses, remove dust with a blast of oil-free air. If this is not sufficient, follow these steps.

C A U T I O N : Handle polymer lenses by their edges only. Never rub anything dry on a polymer lens.

Page 13 of the Source Technologies 410 user manual — Cleaning the reflector
Page 13 · click to enlarge
Page 13
1. Remove the beam focus knob at the bottom of the barrel (see Figure 1 ). Remove the lens

tube from the barrel.

2. Use a Phillips screwdriver to remove the brackets that hold the lens in place. Remove the lens from the tube.
3. Dip the lens in a clean isopropyl alcohol/water mixture (9 parts water to 1 part isopropyl alcohol).
4. Use a soft moistened nylon bristle brush to wash the lens’ smooth side in a linear (noncircular) motion.
5. Use the same brush to lightly wash the lens’ ridged side by following its ridges.
6. Dip the lens in a clean isopropyl alcohol/water mixture (9 parts water to 1 part isopropyl alcohol).
7. Dry the smooth and ridged surfaces with an air gun. Make sure the air flow moves liquid away from you.
8. Inspect the lens for dirt. Repeat steps 3-7 if necessary.
9. Set the lens back in the lens tube with the ridged side facing the front of the tube. Reinstall the lens brackets.
10. Slide the lens tube back into the barrel with gel frame retainer on top. Reinstall beam focus knob.

Cleaning the reflector

W A R N I N G : Unplug the fixture before attempting to clean the reflector.

To quickly clean the reflector, remove the lens tube and clean the dust from the reflector with a blast of oil-free air. You may also wipe the reflector with a clean lint-free cloth. If either method is not sufficient, follow these steps.

1. To protect the lamp housing during cleaning, remove the lamp housing by loosening the

knurled bolt and pulling the housing straight out. See Figure 3.

2. Remove the barrel rotation knob located at the bottom of the barrel (see Figure 1 ). Use a Phillips screwdriver to remove the retainer bolt located on top of the reflector housing.
3. Rotate the barrel 45° in either direction. Carefully remove the barrel from the reflector housing.
4. Remove dust with a blast of oil-free air or wipe with a clean, lint-free cloth. Isopropyl alcohol, distilled water or a 50%-50% mixture of each can be used to clean the glass surface.
5. Insert the barrel into the reflector housing with the iris/gobo slot on top. Align the triangles on both parts.
6. While gently pressing in, rotate the barrel 45° clockwise until it sets into position, then rotate the barrel counterclockwise 45°. The barrel should be firmly attached and the triangles should be aligned.
7. Reinstall the barrel rotation knob and tighten the retainer bolt.
8. Reinstall the lamp housing and tighten the knurled bolt.
Page 14 of the Source Technologies 410 user manual — Portable appliance test (PAT) guidelines
Page 14 · click to enlarge
Page 14

Portable appliance test (PAT) guidelines

The Portable Appliance Test is a set of tests that must be administered to electrical equipment in the UK and some locations in Europe to ensure safety.The tests are typically carried out using a small PAT device. The PAT device connects to a power source and then attaches to the product via an electrical outlet and test probes. The PAT provides a simple pass or fail result, allowing rapid testing of large inventories.

Source Four CE luminaires include a specific PAT point where the test clip is attached, as shown in Figure 12. PAT tests should be performed by a qualified technician. Your local regulatory authority has guidelines on the testing frequency.

PAT device connection point

Page 15 of the Source Technologies 410 user manual — Portable appliance test (PAT) guidelines
Page 15 · click to enlarge
Page 15
Page 15 of the Source Technologies 410 user manual — Portable appliance test (PAT) guidelines
Page 16 of the Source Technologies 410 user manual — Portable appliance test (PAT) guidelines
Page 16 · click to enlarge
Page 16

Corporate Headquarters „ 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA „ Tel +608 831 4116 „ Fax +608 836 1736 London, UK „ Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK „ Tel +44 (0)20 8896 1000 „ Fax +44 (0)20 8896 2000 Rome, IT „ Via Ennio Quirino Visconti, 11, 00193 Rome, Italy „ Tel +39 (06) 32 111 683 „ Fax +39 (06) 32 656 990 Holzkirchen, DE „ Ohmstrasse 3, 83607 Holzkirchen, Germany „ Tel +49 (80 24) 47 00-0 „ Fax +49 (80 24) 47 00-3 00 Hong Kong „ Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong „ Tel +852 2799 1220 „ Fax +852 2799 9325 Service: (Americas) service@etcconnect.com „ (UK) service@etceurope.com „ (DE) techserv-hoki@etcconnect.com „ (Asia) service@etcasia.com Web: www.etcconnect.com „ Copyright © 2007 ETC. All Rights Reserved. „ Product information and specifications subject to change. 7060M1210-06.01 „ Rev A „ Released 08/2007

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Source Technologies 410

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Source Technologies 410

Be the first to ask — other owners or our team will answer.

Original document

Source Technologies 410 manual PDF

16 pages·942 KB·Indoor Furnishings·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…