Important Safeguards Page 11 ____________________________
LIB-D81
4-673-841-13(1)

To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
The mains plug on this equipment must be used to disconnect mains power. Please ensure that the socket outlet is installed near the equipment and shall be easily accessible.
Use the power cord set approved by the appropriate testing organization for the specific countries where this unit is to be used.
Zur Trennung vom Netz ist der Netzstecker aus der Steckdose zu ziehen, welche sich in der Nähe des Gerätes befinden muß und leicht zugänglich sein soll.
Der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäß ISO7779.
AC 100 V - 240 V Current
0.7 A - 0.35 A Frequency
50 / 60 Hz Max. Ambient Temperature
100 V - 240 V Wechselstrom Stromstärke
0,7 A - 0,35 A Frequenz
50 / 60 Hz Max. Umgebungstemperatur
A certified power supply cord has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered. A certified power supply cord not lighter than ordinary polyvinyl chloride flexible cord according to IEC 60227 (designation H05VV-F 3G 0.75 mm2 or H05VVH2-F2 3G 0.75 mm2) shall be used. Alternative a flexible cord be of synthetic rubber according to IEC 60245 (designation H05RR-F 3G 0.75 mm2) shall be used.
Zum Netzanschluss dieses Gerätes ist eine geprüfte Leitung zu verwenden. Es sind die zutreffenden nationalen Errichtungs- und/oder Gerätebestimmungen zu beachten. Es ist eine geprüfte flexible PVC-ummantelte Leitung entsprechend IEC 60227 (H05VV-F 3G 0.75 mm2 oder H05VVH2-F 3G 0.75 mm2) zu verwenden. Andernfalls ist eine flexible Leitung aus synthetischem Gummi entsprechend IEC 60245 (Bauartkurzzeichen H05RR-F 3G 0.75 mm2) zu verwenden.

For the customers in the U.S.A. You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
If you have any questions about this product, please contact Sony Support Center written in the warranty card.

Address: 16450 W. Bernardo Dr., San Diego, CA 92127 U.S.A.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Für Kunden In Deutschland Diese Ausrüstung erfüllt die Europäischen EMC-Bestimmungen für die Verwendung in folgender/folgenden Umgebung(en): ·Wohngegenden ·Gewerbegebiete ·Leichtindustriegebiete (Diese Ausrüstung erfüllt die Bestimmungen der Norm EN55022, Klasse B.)
Ratings are indicated on the rear, while regulatory agency marks are separately affixed on the bottom.



Installing the AIT Autoloader
After opening the box, make sure that all the following items are present. Contact your dealer if anything is missing.
The autoloader weighs about 7 kg (15.4 lb.) and has the following dimensions. Before installing the autoloader, make sure that the surface is appropriate.
The Operating Instructions for this manual are provided in PDF format on the CD-ROM. After setting up the equipment as described in this manual, please read the Operating Instructions (PDF) on the CD-ROM and make necessary settings.
Install the AIT autoloader on a horizontal surface near an AC power outlet. Also leave a gap of about 150 mm (5.9 in.) behind the rear of the unit to allow air to circulate.

Make sure that you position the AIT autoloader as indicated in the illustration. Correct operation is not guaranteed if you place the AIT autoloader on its side.


1 Make sure that the power switch on the rear of the AIT autoloader is in the off position (a is depressed).

2 Connect one end of the power cable to the power supply connector and the other end to the power outlet.
1 Confirm that the power to the host computer and AIT autoloader are off.
2 Connect the SCSI cable and terminator as shown in the figure below. 1 Use a commercial SCSI cable to connect the AIT autoloader to the host computer. 2 Connect the provided terminator to connector.

Connect the AIT autoloader and the host computer with a SCSI cable. This section explains general connection steps. To connect, use an Wide Ultra2 SCSI LVD cable commonly sold in stores. However, when using a model equipped with an AIT-3 or AIT-4 drive, use an Ultra 160 SCSI LVD cable. The autoloader side uses the 68-pin half pitch connector.
When connecting other SCSI devices along with the AIT autoloader, see “Connecting SCSI Peripheral Devices” in Chapter 2 “Installation” in the “Operating Instructions” (PDF).
Host computer

When startup is complete, the message display indicates the number of cartridges in the AIT autoloader.

Refer to the “Operating Instructions” (PDF) and perform the appropriate DIP switch and SCSI ID settings.
When startup is complete, press the DOOR button to open the front door and insert cartridges. For details, refer to the “Operating Instructions” (PDF).
2 After pressing the power switch on the rear panel of the autoloader, wait at least 10 seconds before turning on the host computer.
Turn On the Power Turn on the AIT autoloader, then turn on the host computer.
1 Press the power switch on the rear of the autoloader, as illustrated.

The message display changes as follows and the startup process begins. (Startup takes several minutes.)
During startup, the following appears on the message display.
Moves gradually up and down during the elevator check.
Indicates the startup phase, from 0 to 3.
Startup complete

WARNING
CLEANING
For details about the disaster recovery function, see “Disaster Recovery Function” in Chapter 3 “Basic Usage” in the “Operating Instructions” (PDF).
Message display

When problems occur When problems occur, the ERROR/WARNING or CLEANING LED lights or flashes, and one of the following codes appears on the message display.
WARNING
CLEANING

Notes 1 To begin cleaning the AIT drive, insert the cleaning cartridge in slot CL/8 and press the CLEAN button for at least three seconds. 2 If you are unable to open the front door, it may be locked from your backup software. 3 If the cartridge is not ejected from the AIT drive when an error occurs, proceed as follows. (1) Press the DOOR button for at least five seconds.
Read the Operating Instructions, install cartridges, then make the required settings to use the library. Procedures for making settings and using the library are given in the Operating Instructions (PDF) together with usage precautions and other necessary information. Please be sure to read it.
The cartridge is forcibly ejected from the AIT drive and the front door unlocked. (2) Restart the AIT autoloader. (3) Restart the system. 4 If [ ] appears to be rotating or [E J] flashes on the display, then the loader is in operation. Depending on the state of the cartridge, it may take up to 20 minutes for it to be detected. 5 Pressing the CLEAN and DOOR buttons simultaneously for at least five seconds starts Disaster recovery. 6 In the code reference table, “XX” refers to an error code. 7 Cleaning normally takes approximately one minute. However, if there is a data cartridge in the drive, it must be returned to its slot before cleaning can begin. Furthermore, if the tape of the cartridge in the drive is damaged, it may take some time for it to be successfully ejected. For this reason, cleaning may take up to 20 minutes.

MISURE IMPORTANTI DI SICUREZZA
For your protection, please read these safety instructions completely before operating the appliance, and keep this manual for future reference. Carefully observe all warnings, precautions and instructions on the appliance, or the one described in the operating instructions and adhere to them.
Per la vostra protezione, vi preghiamo di leggere integralmente queste istruzioni di sicurezza prima di utilizzare l'apparecchio, e di conservare questo manuale per consultazioni future.
SECURITES IMPORTANTES
Para sua protecção, leia inteiramente estas instruções de segurança antes de utilizar o aparelho e guarde o manual para futuras consultas. Observe cuidadosamente todos os avisos, precauções e instruções no aparelho ou as descritas nas instruções de utilização e siga-as rigorosamente.
Pour votre protection, lisez attentivement ces instructions de sécurité avant d'utiliser l'appareil. Conservez toujours ce manuel sous la main. Respectez strictement tous les avertissements, mises en garde et instructions figurant sur l'appareil ou celles que vous trouverez dans les instructions d'utilisation.
WICHTIGE SCHUTZMABNAHMEN
Oman turvallisuutesi takia luet ohjeet huolellisesti ennen vastaanottimen käyttöä ja säilytä ne vastaisen varalle. Noudata huolellisesti kaikkia vastaanottimeen sekä käyttöohjeeseen merkittyjä varoituksia, huomautuksia ja ohjeita.
Bitte lesen Sie diese Sicherheitsvorschriften vollständig durch bevor Sie das Gerät anschalten und heben Sie sie für künftige Rückfragen auf. Bitte befolgen Sie alle Wahrnungen, Vorsorgsmaßnahmen und Vorschriften, die auf dem Gerät oder in der Bedienungsanleitung angegeben werden und respektieren Sie sie.
NOTAS IMPORTANTES DE SEGURIDAD
Läs för din egen säkerhets skull alla dessa säkerhetsföreskrifter noga innan du börjar använda apparaten, och håll handboken tillgänglig för framtida behov. Följ noga alla varningar, säkerhetsföreskrifter och anvisningar på apparaten och i handboken.
Para su protección, sírvase leer completamente estas instrucciones de seguridad antes de accionar el aparato y guarde este manual para su posterior consulta. Tome buena nota de todas las advertencias, precauciones e instrucciones sobre el aparato o de aquellas que figuran en las instrucciones de funcionamiento, y sígalas.
Les sikkerhetsinstruksen nøye før du tar apparatet i bruk, og ta vare å håndboken for senere bruk. Legg nøye merke til alle advarsler, forsiktighetsregler og instrukser for apparatet, samt de som er beskrevet i bruksanvisningen, og følg disse nøe.
Voor uw veiligheid : Gelieve deze veiligheidsinstructies volledig te lezen alvorens het toestel te bedienen en deze handleiding te bewaren voor toekomstige naslag. Bekijk zorgvuldig alle waarschuwingen, voorzorgsmaatregelen en instructies die op het toestel zijn vermeld of zoals beschreven in de gebruiksaanwijzing en neem ze in acht.

Læs disse sikkerhedsinstrukser hel igennem, inden apparatet tages i brug og opbevar manualen til senere brug - for din egen sikkerheds skyld. Læg nøje mærke til alle advarsler, forholdsregler og instruktioner på apparatet eller dem, der er beskrevet i betjeningsvejledningen, og overhold dem.

USE
SERVICE
Power Sources — This unit should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of electrical power, consult your dealer or local power company.
Damage Requiring Service — Unplug the unit from the wall outlet and refer servicing to qualified service personnel under the following conditions:
For the unit with a three-wire grounding type ac plug: If you are unable to insert the plug into the outlet, contact your electrician to have a suitable plug installed. Do not defeat the safety purpose of the grounding plug.
AC Power cord: The AC power cord should have appropriate safety approvals or marking for the country in which the equipment will be used. Consult your dealer or local power company.
Cleaning — Unplug the unit from the wall outlet before cleaning or polishing it. Do not use liquid cleaners or aerosol cleaners. Use a cloth lightly dampened with water for cleaning the exterior of the unit.
Object and Liquid Entry — Never push objects of any kind into the unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.
Servicing — Do not attempt to service the unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer to all servicing to qualified service personnel.
Water and Moisture — Do not use power-line operated units near water - for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, etc.
Power-Cord Protection — Route the power cord so that it is not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the plugs, receptacles, and the point where the cord exits from the appliance.
Accessories — Do not place the unit on an unstable cart, stand, tripod, bracket, or table. The unit may fall, causing serious injury to a child or an adult, and serious damage to the unit. Use only a cart stand tripod, bracket, or table recommended by the manufacturer.
Ventilation — The slots and openings in the cabinet are provided for necessary ventilation. To ensure reliable operation of the unit, and to protect it from overheating, these slots and openings must never be blocked or covered.



Sony Corporation For information about the AIT autoloader, refer to your reseller.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| 0 1 | Cartridge not completely inserted. | Open the front door and reinsert cartridges as necessary. | p.9 |
| 0 3 | Cleaning cartridge not inserted at the beginning of cleaning. | Insert the cleaning cartridge in slot CL/8. | p.9 |
| 0 4 | A data cartridge was inserted in slot CL/8 at the beginning of cleaning. | Insert the cleaning cartridge in slot CL/8. | p.9 |
| 0 5 | The DOOR button is pressed, when the front door is locked by an application. | Do not attempt to open the front door manually. | p.9 |
| 0 6 | Internal temperature abnormally high. | Make sure that the operating environment is within the allowed temperature limits (5 to 40°C) and verify that AIT autoloader fan is operating normally. | p.9 |
| 0 7 | Parts replacement needed. | For replacement parts, contact customer service. | p.9 |
| 0 8 | Too many cartridges in the loader. (There are cartridges in all the slots and the AIT drive.) | Eject one or more cartridges from the AIT autoloader. | p.9 |
| 0 9 | The internal temperature of the device is too low to guarantee operation. | Make sure that the operating environment is within the allowed temperature limits (5 to 40°C). | p.9 |
| 1 0 | Cleaning cartridge tape spent. | The spent cleaning cartridge is set. Replace the spent cleaning cartridge with a new one. | p.9 |
| 1 1 | Cleaning failed. | Cleaning failed. Repeat the cleaning procedure. | p.9 |