EN
Sony logo
Official user manual

Sony ICDU70

2 pages·458 KB·Headphones·PDF·ENDEFRITNLJA
Sony ICDU70
Table of Contents 54 sections Battery life * 1 · Maximum recording time · Index to Parts and Controls · IC Recorder · … ShowHide
Battery life * 1p.1Maximum recording timep.1Index to Parts and Controlsp.1IC Recorderp.1Main Unitp.1ICD-U50 ICD-U60 ICD-U70p.1Operating Instructionsp.1Remaining memory indicatorp.1ICD-U50/U60/U70p.1Adding a New Message Number during Recordingp.1(Dividing Recording)p.1Troubleshootingp.1Setting the Clockp.1Starting Recording Automatically in Response to thep.1Sound (VOR Function)p.1Playback/Erasingp.1Playing Back Messagesp.1Display Windowp.1Recordingp.1Recording Messagesp.1Supplied Accessoriesp.1Getting Startedp.1Press REC/PAUSE in the stop mode top.1Installing the Batteryp.1Slide and lift the battery compartmentp.1Adjusting the playback speed (DPC: Digital Pitch Control function)p.1! Notesp.1To resume normal playback Set the DPC switch to OFF. ! Notesp.1Insert one LR03 (size AAA) alkalinep.1Selecting the playback modep.1Monitoring the recordingp.1Selecting the recording modep.1Selecting the microphone sensitivityp.1Playing back a specified section repeatedly (A-B Repeat)p.2Playing Back MP3 Files Using the IC Recorderp.2Precautionsp.2Press /MENU to select “ .”p.2Maximum recording time of MP3 files * Playback order ofp.2Erasingp.2Erasing messages one by onep.2Erasing all messages in a folderp.2Specificationsp.2Using Your IC Recorder with a Personal Computerp.2Selecting a playback modep.2System requirementsp.2Playing Back Messages Using the Computerp.2Connecting Other Equipment to the IC Recorderp.2Recording Sound on the IC Recorder with Otherp.2Copying messages from the Computer to the IC recorderp.2Equipmentp.2Menu Settingsp.2Connecting the IC Recorder to the Computerp.2Making Settings for the Menup.2Remove the USB cap from the ICp.2
Page 1 of the Sony ICDU70 user manual — Table of Contents
Page 1 · Contents
Contents

Contents

Battery life * 1p.1Maximum recording timep.1Index to Parts and Controlsp.1IC Recorderp.1Main Unitp.1ICD-U50 ICD-U60 ICD-U70p.1Operating Instructionsp.1Remaining memory indicatorp.1ICD-U50/U60/U70p.1Adding a New Message Number during Recordingp.1(Dividing Recording)p.1Troubleshootingp.1Setting the Clockp.1Starting Recording Automatically in Response to thep.1Sound (VOR Function)p.1Playback/Erasingp.1Playing Back Messagesp.1Display Windowp.1Recordingp.1Recording Messagesp.1Supplied Accessoriesp.1Getting Startedp.1Press REC/PAUSE in the stop mode top.1Installing the Batteryp.1Slide and lift the battery compartmentp.1Adjusting the playback speed (DPC: Digital Pitch Control function)p.1! Notesp.1To resume normal playback Set the DPC switch to OFF. ! Notesp.1Insert one LR03 (size AAA) alkalinep.1Selecting the playback modep.1Monitoring the recordingp.1Selecting the recording modep.1Selecting the microphone sensitivityp.1Playing back a specified section repeatedly (A-B Repeat)p.2Playing Back MP3 Files Using the IC Recorderp.2Precautionsp.2Press /MENU to select “ .”p.2Maximum recording time of MP3 files * Playback order ofp.2Erasingp.2Erasing messages one by onep.2Erasing all messages in a folderp.2Specificationsp.2Using Your IC Recorder with a Personal Computerp.2Selecting a playback modep.2System requirementsp.2Playing Back Messages Using the Computerp.2Connecting Other Equipment to the IC Recorderp.2Recording Sound on the IC Recorder with Otherp.2Copying messages from the Computer to the IC recorderp.2Equipmentp.2Menu Settingsp.2Connecting the IC Recorder to the Computerp.2Making Settings for the Menup.2Remove the USB cap from the ICp.2
Page 2 of the Sony ICDU70 user manual — Menu settings
Page 2 · click to enlarge
Page 2

Playing back a specified section repeatedly (A-B Repeat)

Playing Back MP3 Files Using the IC Recorder

Menu item Settings (*Initial setting)

Precautions

1 During playback, press A-B (repeat) briefly to set the starting point (A). 2 While “A-B B?” is flashing, press A-B briefly again to set the finishing point (B). “A-B REPEAT” appears and the specified section is played back repeatedly.

DPC:0% When you set the DPC switch to ON, you can adjust the speed of the playback between twice the normal speed (+100%) and half the normal speed (–50%). Set the speed by 10% for + setting (“FAST PLAY” appears) and by 5% for – setting (“SLOW PLAY” appears).

Drag and drop the MP3 files from the computer to the (MUSIC) folder of the IC

recorder. The number of directory levels allowed for the folder is 2 and the maximum number of folders is 300. The total number of files allowed in the (MUSIC) folder is 999.

Operate the unit only on 1.5 V DC. Use one LR03 (size

AAA) alkaline battery.

To stop A-B Repeat playback Press STOP. The A-B Repeat setting will be cancelled. To pause A-B Repeat playback, press . !Notes

VOICE PL MODE> Set the playback mode for the message folders. 1 FILE PLAY*: When the playback of one message is finished, the IC recorder stops at the beginning of the next message. 1 FILE REPEAT: One message is played back repeatedly. CONTINUED PLAY: All messages in one folder are played back continuously. !Note When you select the folder, “VOICE PL MODE>” is not displayed.

Press /MENU to select “ .”

Do not operate the unit while driving, cycling or operating

any motorized vehicle.

Press the control key toward or to select a file to play and press .

The selected file starts to play.

You cannot set A-B Repeat for a section that overlaps two or more messages.

Do not leave the unit in a location near heat sources, or

Press STOP to stop playback.

If you do not set the finishing point (B), the finishing point is automatically set at the end of the message.

in a place subject to direct sunlight, excessive dust or mechanical shock.

When you stop the A-B Repeat playback with the DPC switch set to ON, the playback may not start from

Maximum recording time of MP3 files * Playback order of

the point you stopped the A-B Repeat playback.

Should any solid object or liquid fall into the unit,

ICD-U50 Bit rate Maximum recording time of files 256 kbps Approx. 2 hr. 10 min. 128 kbps Approx. 4 hr. 40 min. 48 kbps Approx. 11 hr. 35 min.

MP3 files using the IC recorder The MP3 files in the folder copied from the computer to the IC recorder are played back in the order shown, from the highest directory to the lowest (from to ), when the “MUSIC PL MODE>” menu is set to “ALL REPEAT.”

MUSIC PL MODE> Set the playback mode for MP3 files. 1 FILE PLAY: When the playback of one file is finished, the IC recorder stops at the beginning of the next file. 1 FILE REPEAT: One file is played back repeatedly. CONTINUED PLAY*: All files in one folder are played back continuously. ALL REPEAT: All files in the folder are played back repeatedly. SHUFFLE: All files in the folder are played back in random order repeatedly. !Note When you select the A, B, C, D or E folder, “MUSIC PL MODE>” is not displayed.

remove the battery and have the unit checked by qualified personnel before operating it any further.

Erasing

Noise may be heard when the unit is placed near an AC

!Note Once a recording has been erased, you cannot retrieve it.

power source, a fluorescent lamp or a mobile phone during recording or playback.

Noise may be recorded when an object, such as your

Erasing messages one by one

ICD-U60 Bit rate Maximum recording time of files 256 kbps Approx. 4 hr. 20 min. 128 kbps Approx. 8 hr. 40 min. 48 kbps Approx. 23 hr. 10 min.

finger, etc., rubs or scratches the unit during recording.

1 Select the message you want to erase. 2 Select “ERASE A MSG>” in the menu and press . “ERASING….” appears on the display and the message is erased.

folder displayed on the computer

To clean the exterior, use a soft cloth slightly moistened in

water. Do not use alcohol, benzine or thinner.

FORMAT> Initialize the flash memory. !Note To initialize the flash memory, use the IC recorder, not the computer.

To cancel erasing Press STOP before step 2.

If you have any questions or problems concerning your unit, please consult your nearest Sony dealer.

ICD-U70 Bit rate Maximum recording time of files 256 kbps Approx. 8 hr. 40 min. 128 kbps Approx. 17 hr. 25 min. 48 kbps Approx. 46 hr. 30 min. (hr.: hours/min.: minutes)

Backup recommendations To avoid potential risk of data loss caused by accidental operation or malfunction of the IC recorder, we recommend that you save a backup copy of your recorded messages on a computer, etc.

DATE & TIME> Set the clock. (06Y1M1D*)

Erasing all messages in a folder

BEEP:ON Set for a beep to be heard or not. ON*: A beep will sound to indicate that an operation has been accepted. OFF: No beep sound will be heard.

1 Select the folder with the messages you want to erase. 2 Select “ERASE ALL MSG>” in the menu and press . “ERASING….” appears on the display and all the messages in the folder are erased.

LED:ON Turn the OPR indicator on or off during operation. ON*: During recording or playback, the OPR indicator lights or flashes. OFF: The OPR indicator does not light, even during operation. !Note When the IC recorder is connected to the USB connector of your computer, the OPR indicator always flashes regardless of the menu setting.

To cancel erasing Press STOP before step 2. !Note It may take a few minutes to erase the messages, if there are many massages to be erased in a folder.

* When deleting “Player Plug-in for Windows Media Player” and “Windows® 2000 Professional, Windows® 98 Second Edition Driver.” The maximum recording time varies if files other than the

Specifications

Built-in flash memory 256 MB (ICD-U50) 512 MB (ICD-U60), 1GB (ICD-U70), Monaural recording Recording time

MP3 files are stored in the IC recorder.

! Notes

BACK LIGHT:ON Turn the backlight in the display window on or off. ON*: The backlight in the display window lights up. OFF: The backlight in the display window does not light, even during operation.

If you copy MP3 files to the A, B, C, D, or E folder, the IC recorder cannot recognize the files and the files

ICD-U50 HQ: 28 hours 40 minutes SP: 76 hours 30 minutes LP: 125 hours 15 minutes ICD-U60 HQ: 57 hours 30 minutes SP: 153 hours 25 minutes LP: 251 hours 5 minutes ICD-U70 HQ: 115 hours 10 minutes SP: 307 hours 15 minutes LP: 502 hours 45 minutes Frequency range

Using Your IC Recorder with a Personal Computer

cannot be played back.

If the DPC switch is set to ON, the playback sound changes and playback becomes monaural.

ERASE ALL MSG> All files in the folder will be erased.

ERASE A MSG> One message will be erased.

Selecting a playback mode

Select the playback mode in the “MUSIC PL MODE>” menu (see “Menu Settings”).

System requirements

Playing Back Messages Using the Computer

Connecting Other Equipment to the IC Recorder

IBM PC/AT*1 or compatible

HQ: 160 - 6,800 Hz SP: 100 - 3,400 Hz LP: 100 - 3,400 Hz MP3: 20 - 20,000 HZ Bit rates for MP3 files (kbps)

– CPU: 266MHz Pentium*2 II processor or higher – RAM: 64 MB or more – Hard disk space: 5 MB or more, depending on the size and number of sound files you intend to store – USB port – Sound board: Sound Blaster 16 compatible – Display: High color (16 bits) or more, and 800 480 dots or more

Drag and drop the messages (files) you want to copy from the folder of the IC

recorder to the computer.

Double-click the file on the computer to start playback.

MPEG Ver. 1 Layer 3: 32, 40, 48, 56, 64, 80, 96, 112, 128, 160, 192, 224, 256, 320 MPEG Ver. 2 Layer 3/MPEG Ver. 2.5 Layer 3: 8, 16, 24, 32, 40, 48, 56, 64, 80, 96, 112, 128, 144, 160 Sampling frequencies for MP3 files (kHz)

Recording Sound on the IC Recorder with Other

Copying messages from the Computer to the IC recorder

OS: Microsoft® Windows® XP Media Center Edition 2005, Windows® XP Media Center Edition

Equipment

1 Drag and drop messages (files) you want to copy from the computer to the A, B, C, D, or E folder of the IC recorder. !Note If you copy messages (files) to the (MUSIC) folder, the IC recorder cannot recognize the messages (files) and the messages (files) cannot be played back.

2004, Windows® XP Media Center Edition, Windows® XP Professional, Windows® XP Home Edition, Windows® 2000 Professional, Windows® Millennium Edition*3, Windows® 98 Second Edition*3,*4 (standard installation)

Connect the (headphone) jack of the IC recorder to the microphone or line input connector of the other equipment.

MPEG Ver. 1 Layer 3: 32.0, 44.1, 48.0 MPEG Ver. 2 Layer 3: 16.0, 22.05, 24.0 MPEG Ver. 2.5 Layer 3: 8.0, 11.025, 12.0 Speaker

Windows Media PlayerVer. 6.4 or higher (your computer must meet the system requirements (operating

environment) necessary for using the Windows Media Player) *1 IBM, PC/AT are registered trademarks of International Business Machines Corporation. *2 Pentium is is registerd trademark of Intel Corporation. *3 Excluding the People’s Republic of China model. *4 Microsoft® and Windows® are registerd trademarks of Microsoft Corporation.

To (headphone) jack Audio connecting cable To microphone or line input connector

Tape recorder, etc. tional audio connecting cable (not supplied) When connecting to the microphone input connector, use a connecting cable with a resistor To the IC recorderTo the other equipment Stereo mini-plug (with aresistor)Mini-plug (monaural) (with a resistor) Stereo mini-plug (with aresistor) Stereo mini-plug (with a resistor)

approx. 10 mm (13/32 in.) dia. Power output

Menu Settings

35 mW (when using a built-in speaker) Output

Connecting the IC Recorder to the Computer

Headphone jack (stereo minijack) for 8 - 300 ohms headphone(s)/ear receiver Input/Output

!Note The plug-in for playback using a computer is already installed in the IC recorder, therefore, be careful not to delete it.

Making Settings for the Menu

USB connector Power requirements

One LR03 (size AAA) alkaline battery: 1.5 V DC Dimensions (w/h/d)

Press and hold /MENU for more than 1 second to enter the menu mode.

Remove the USB cap from the IC

(not incl. projecting parts and controls) 30.0 × 99.7 × 20.0 mm (1 3/16 × 4 × 13/16 in.) Mass (incl. battery)

recorder and connect the recorder to the USB connector of your computer. For the use with the Windows 2000 Professional or Windows 98 Second Edition, install the driver software available at the Customer Support Home Page. (URL on a separate sheet included)

Press the control key right or left to select the item and then press .

Press STOP to exit the menu mode.

64 g (2.3 oz) Optional accessories

Menu settings

Active speaker SRS-T88, SRS-T80

Menu item Settings (*Initial setting)

To the IC recorder To the other equipment

to USB connector IC recorder

Your dealer may not handle some of the above listed optional accessories. Please ask the dealer for detailed information.

REC MODE:HQ Set the recording mode. HQ*: You can record with high-quality sound. SP: You can record with standard quality sound. LP: You can record for a longer time.

Stereo mini-plug (without a resistor) Mini-plug (monaural) (without a resistor)

Install the plug-in into your computer.

Stereo mini-plug (without a resistor) Stereo mini-plug (without a resistor)

MPEG Layer-3 audio coding technology and patents licensed from Fraunhofer IIS and Thomson.

Open the drive designated for the IC recorder using Explorer, double-click “PlayerTool,” then double‑click “PlayerPluginSetup.exe” and the plug-in for the Windows Media Player will be installed.

!Note Optional audio connecting cables are not sold in Europe.

MIC SENS:H Set the microphone sensitivity. H* (high): To record at meetings or in a quiet and/or spacious place. L (low): To record dictation or in a noisy place.

Design and specifications are subject to change without notice.

DISPLAY> Change the display mode. (Items shown in the playback/stop/recording mode) COUNTER*: Elapsed playback time of one message/ Elapsed playback time of

If you delete the plug-in from the IC recorder, see the Customer Support Home Page. The URL is provided

on a separate sheet included.

one message /Recording time REMAIN: Remaining time of one message/Remaining recording time/ Remaining recording time REC DATE: Recorded date/ Recorded date/Current date REC TIME: Recorded time/ Recorded time/Current time

You can also use this IC recorder as a USB mass storage device. !Notes

The IC recorder is communicating with the computer whenever the OPR indicator flashes or is lit in

orange. While the IC recorder is communicating with the computer, do not remove the IC recorder from the computer.

VOR:OFF Set the VOR function. ON: The VOR function is activated. Recording starts when the IC recorder detects sound and stops when no sound is heard (“VOR PAUSE” flashes on the display), eliminating recording during soundless periods. OFF*: The VOR function does not work. !Note The VOR function is affected by the sound around you. Set the microphone sensitivity in the menu according to the recording conditions. If recording is not satisfactory after you have changed the microphone sensitivity, or for important recordings, set the VOR function to “OFF.”

When you turn on or restart your computer, disconnect the IC recorder from the computer.

Show 7 more labels / short text on this page
On power · On safety · On handling · On noise · On maintenance · Recording media · Computer

Ask about the Sony ICDU70

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Sony ICDU70

Be the first to ask — other owners or our team will answer.

Original document

Sony ICDU70 manual PDF

2 pages·458 KB·Headphones·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…