Instruction/ maintenance manual of the product FBDA B&B Electronics
Go to page of 10
Documentat ion Number FBDA0797 M anual Cover Page B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Strain Gauge/Load Cell Bridge Amplifier Model FBDA D.
Documentat i on Num ber FBDA0797 Manual Table of Content s i B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 TABLE OF CONTENTS CHAPTER 1: INTRODUCTION...................................................
Documentat ion Number FBDA0797 M anual 1 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 1: Intr oduction Features The FBDA is a s ignal conditioning module that allows you to measure voltages produced by full- bridge sensor s using a data acquisition module.
2 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Packing List Examine the shipping ca rton and the contents for physical damage. The following items should be in the s hipping carton: 1.
Documentat ion Number FBDA0797 M anual 3 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 2: Connections Power Supply Connections The FBDA module requires 13 to 18VDC @ 10mA. Model 232PS2 available from B&B Electr onics is recommended.
4 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Data Acquisition Connec tions The connections to the Data Acquisition Module are made through a DB-25 (male) connector.
Documentat ion Number FBDA0797 M anual 5 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Figure 2.1: Block Di agram of FBDA Connecti ons A / D Note: C.
Documentat ion Number FBDA0797 M anual 7 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 3: Gain Selection The FBDA has sev eral different gain settings to provide the largest poss ible voltage range for an A/D conv erter.
8 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Sensors that inc orporate bridge c ircuitry usually have noticeable zero offs ets. This s hould be considered when tak ing measurements and deter mining gain.
Documentat ion Number FBDA0797 M anual 9 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 4: Excitation V o ltage Sensors that ar e based on a Wheatstone bridge need an excitation voltage to ex cite the bridge.
An important point after buying a device B&B Electronics FBDA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought B&B Electronics FBDA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data B&B Electronics FBDA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, B&B Electronics FBDA you will learn all the available features of the product, as well as information on its operation. The information that you get B&B Electronics FBDA will certainly help you make a decision on the purchase.
If you already are a holder of B&B Electronics FBDA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime B&B Electronics FBDA.
However, one of the most important roles played by the user manual is to help in solving problems with B&B Electronics FBDA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device B&B Electronics FBDA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center