Interaktiv Showerpanel Installation Instructions / W arranty.
Interaktiv Showerpanel I Interaktiv Showerpanel II Showerpanel I Showerpanel II handshower & bodyjets handshower , bodyjets, tub spout Metro 06572000 06573000 Solaris 06549XX0 06550XX0 Stratos 06564XX0 06565XX0 Interaktiv S 06893000 06894000 Proaktiv* 06964000 06971000 Product Specification Flow rate of handshower 2.
Check Package Contents Save time and aggravation. Before beginning installation, check the contents of this package. Make sure that all parts are present and in good condition. If any par t is missing or damaged, please contact Hansgrohe Customer Ser vice before proceeding.
Roughing-in This unit can be installed on a flat wall or in a 90 o corner . Instructions for installation on a flat wall begin on page 5. Go to page 8 if the panel is to be installed in a corner . Ensure that you have a minimum 83” ceiling height from the standing surface.
Installation -- Flat W all W rap the threads on the supply nipples with T eflon thread tape. Install the enclosed elbows so that the outlets face upwards. Measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top screw hole.
Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows. Use two wrenches, as shown, to prevent the supply hoses from twisting. Attach the seals to the side covers. Install the side covers. The pins on the covers must go into the grooves on the sides of the panel.
Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel.
Installation in 90 o Corner W rap the threads on the nipples with T eflon thread tape. Install the enclosed elbows so that the outlets face upwards. In the corner , measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top mounting bracket.
While a helper holds the panel, attach the supply hoses to the elbows with the compression fittings. Use two wrenches, as shown in the diagram, to prevent the supply hoses from twisting.
Clip the side cover seals as shown in the diagram. Attach the side cover seals to the valve cover . Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel.
Install the Handle Push the handle over the valve stem. T ighten the set screw on the bottom of the handle with a 3 mm Allen wrench. The set screw must engage the slot milled into the thermoelement. Install the Handshower Place a black rubber washer in the short hose end connector .
Justify the Handle T urn the temperature control knob so that the indicator is next to the 100 o marking. Replace the handle. T ighten the set screw . T urn the water on to the handshower . T ur n the temperature control knob so that the water mea- sures 100 o F on a thermom- eter .
Set the High T emperature Limit Stop (optional) Loosen the set screw on the handle. Remove the handle. Remove the clip and the high temperature limit stop from the stem. Grasp the barrel on the cartridge and tur n it counter - clockwise to turn on the handshower .
Using the Handshower The handshower has 3 spray modes -- Rainl AIR, Whirl AIR, and Balance AIR. Push the function lever until the desired spray mode is achieved. User Instructions - Showerpanel I T urn the temperature control knob clockwise to make the water cooler , counter-clockwise to make it warmer .
Scale Removal The Raindance Air 3-jet handshower incorporates the Rubit TM cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge.
A possible cause of lost pressure, especially if the pressure decreases as the temperature increases, is debris clogging the filter screens on the thermostatic cartridge. If this occurs, the screens should be cleaned. T urn the water off at the main. Remove the handle.
Replacement Parts 1 slider 97024000 2 hose 28276XXX 3 shelf 25969000 4 sleeve 88520XXX 5 thermostat cartridge 94282000 6 thermoelement, panel I 88533000 thermoelement, panel II 88500000 7 side cover 2.
Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada.
year , with respect to Interaktiv and Retroaktiv products, and (ii) for 5 years, with respect to AXOR, ShowerPower and Pharo products. THIS W ARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT P A Y FOR: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship.
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770 360-9880 • Fax 770 360 9887 www .hansgrohe-USA.com US - Installation Instructions • Part No.
An important point after buying a device Axor Showerpanel (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Axor Showerpanel yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Axor Showerpanel - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Axor Showerpanel you will learn all the available features of the product, as well as information on its operation. The information that you get Axor Showerpanel will certainly help you make a decision on the purchase.
If you already are a holder of Axor Showerpanel, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Axor Showerpanel.
However, one of the most important roles played by the user manual is to help in solving problems with Axor Showerpanel. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Axor Showerpanel along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center