Form # ZCE547 Date 2006June7/A

1/2" Pistol Grip Twin Hammer Impact Wrenches
Includes – Foreseen Use, Work Stations, Putting Into Service, Operating, Dismantling, Assembly and Safety Rules.
Manufacturer/Supplier Sioux Tools, Inc.
Product Type 1/2" Pistol Grip Twin Hammer Impact Wrenches
RPM 8,000 Cycles Per Min.
Serial No. Model No/Nos 5000A Std. Anvil 5000AL 2" Ext. Anvil 5000AP Std. Pin Anvil
Murphy, NC 28906 U.S.A.
Product Net Weight 6.00 (Std) 6.10 (2") lbs 2.75 (Std) 2.77 (2") Kg
Recommended Max.
Size – Minimum 3/8 ins 10 mm
Hose Length 30 Ft 10 M
Recommended Working 6.2 bar 90 PSI Maximum 6.2 bar 90 PSI
WARNING
Vibration Level 13 Meters / Sec 2
Always Read Instructions Before Using Power Tools
Use – Safety Glasses YES
Always Wear Safety Goggles
Use – Safety Gloves
Use – Safety Boots
Use – Breathing Masks
Avoid Prolonged Exposure To Vibration
Use – Ear Protectors YES
Safety rules when using 5000A/5000AL/5000AP Impact Wrenches – Use only impact sockets and extensions, universal joints, etc. rated as being suitable for use with impact wrenches. – Prolonged exposure to vibration may cause injury. – Read all instructions before using this tool. All operators must be fully trained in its use and aware of these safety rules. – Do not exceed the maximum working air pressure. – Use personal protection equipment as recommended. – Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects and other reproductive harm. – Use only compressed air at the recommended conditions. – If the tool appears to malfunction, remove from use immediately and arrange for service and repair. If it is not practical to remove tool from service, then shut off the air supply to the tool and write or have written a warning note and attach it to the tool. – If tool is to be used with a balancer or other suspension device, ensure that the tool is firmly attached to the suspension/support device. – When operating the tool, always keep the body and particularly the hands away from the working attachment fixed to the tool. – The tool is not electrically insulated. Never use the tool if there is any chance of coming into contact with live electricity. – Always when using the tool, adopt a firm
footing and/or position and grip the tool sufficiently only to overcome any reaction forces that may result from the tool doing work. Do not overgrip. – Use only correct spare parts for maintenance and repair. Do not improvise or make temporary repairs. Major servicing and repairs should only be carried out by persons trained to do so. – Do not lock, tape, wire, etc. the ‘On/Off’ valve in ‘On’ position. The trigger/lever, etc. must always be free to return to the ‘Off’ position when released. – Always shut off the air supply to the tool and press the ‘On/Off’ valve to exhaust the air from the feed hose before fitting, removing or adjusting the working attachment fitted to the tool. – Before using the tool, make sure that a shut off device has been fitted to the air supply line and the position is known and easily accessible so that the air supply to the tool can be shut off in an emergency. – Check hose and fittings regularly for wear.

Figure 1 Recommended Air Supply System

incorporating an easy to reach and operate air shut off valve. The air supply should be lubricated. It is strongly recommended that an air filter, regulator, lubricator (FRL) is used, as shown in Figure 1, as this will supply clean, lubricated air at the correct pressure to the tool. Details of such equipment can be obtained from your supplier. If such equipment is not used, then the tool should be lubricated by shutting off the air supply to the tool, depressurizing the line by pressing the throttle lever on the tool. Disconnect the air line and pour into the hose adaptor a teaspoonful (5ml) of a suitable pneumatic motor lubricating oil preferably incorporating a rust inhibitor. Reconnect tool to air supply and run tool slowly for a few seconds to allow air to circulate the oil. If tool is used frequently, lubricate on daily basis and if tool starts to slow or lose power. When lubricating, also ensure that the air strainer in hose adaptor is clean. It is recommended that joint tightness of the threaded fastener assembly be checked with suitable measuring equipment. It is recommended that the air pressure at the tool while the tool is running is 90 p.s.i./6.2 bar.
Putting Into Service Air Supply Use a clean lubricated air supply that will give a measured air pressure at the tool of 90 p.s.i./6.2 bar when the tool is running with the trigger fully depressed and the air regulator in its maximum opening flow position. Use recommended hose size and length. It is recommended that the tool is connected to the air supply as shown in figure 1. Do not connect a quick connect coupling directly to the tool, but use a whip or leader hose of approximately 12 inches length. Do not connect the tool to the air line system without
Page No 2

Dismantling & Assembly Instructions Disconnect tool from air supply. Unscrew hammer case cap screws (38) and take off hammer case (36). Take out hammer case pilot (35) and anvil (39, 39B or 39C) from hammer case (36). Release hammer (34) by removing hammer pin (33), then take off hammer frame rear washer (19) and motor clamp washer (31). Grip or support housing (1) and shake up and down to allow cylinder (24) to fall free. Take off front end plate (28), cylinder dowel (25), cylinder (24) and 6 rotor blades (27) in order. Unscrew rear rotor bearing retainer (23) and take out rotor (20). Grip motor housing (1) and tap out trigger pin (9) by using a 3.5 mm suitable pin. Remove reverse valve knob screw (16) to take off reverse valve knob (15) and drive reverse valve (12) from reverse valve bushing (10). Be careful not to loose reverse valve detent ball (13). Turn air inlet bushing (6) and pull out valve spring (4), throttle valve bushing (2) and throttle valve stem (5). Reassembly Clean all parts and examine for wear, etc., and replace any parts excessively worn with only parts obtained from the manufacturer or an approved distributor. Lightly coat all parts in a suitable pneumatic tool lubricating oil and pack bearings and gears with a lithium or molybdenum based general purpose grease and reassemble in the reverse order.
Sioux Tools Inc. 250 Snap-on Drive, P.O. Box 1596, Murphy, NC, 28906, USA declare under our sole responsibility that the products
to which this declaration relates are in conformity with the following standard or standards or other normative document or
documents: EN 792, EN 292 Parts 1& 2, ISO 8662 Parts 1 & 7, Pneurop PN8NTC1
following the provisions of 89/392/EEC as amended by 91/368/EEC & 93/44/EC Directives.

Name and signature or equivalent marking of authorized person
Printed in Taiwan · Page No 3
Owners and our team usually reply within a day — and your question helps the next person too.