Instruction/ maintenance manual of the product P1354 Axis Communications
Go to page of 20
AXIS P13 Series AXIS P1354 Network Camera AXIS P1357 Network Camera E N G L I SH Installation Guide.
Legal Considerations Video and audio surveillance can be regulated by laws that vary from country to country . Check the laws in your local region before using this product for surveillance purposes. This product includes one (1) H.264 decoder license and one (1) AAC decoder license.
This product fullls the requirements for immunity according to EN 550 24 ofce and commercial environments Australia/New Zealand This digital equipment fullls the requirements for RF emission according to the Class B limit of AS/NZS CISPR 22. The product shall be connected using a shielded network cable (STP) that is properly grounded.
.
AXIS P13 Series Safety Infor mation Read through this Installation Guide carefully before installing the product. Keep the Installation Guide for future reference. Hazard Levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
AXIS P13 Series Safety Instructions WARNING • The Axis product shall be installed by a trained professional. NO NO NO TICE TICE TICE • The Axis product shall be used in compliance with local laws and regulations. • To use the Axis product outdoors, or in similar environments, it shall be installed in an approved outdoor housing.
AXIS P13 Series WARNING • Risk of explosion if the battery is incorrectly replaced. • Replace only with an identical battery or a battery which is recommended by Axis. • Dispose of used batteries according to local regulations or the battery manufacturer's instructions.
8.
AXIS P13 Series Installation Guide This Installation Guide provides instructions for installing AXIS P1354/P1357 Network Camera on your network. For other aspects of using the product, see the User Manual available at www .axis.com Installation Steps 1.
AXIS P13 Series Hardware Overview 1 4 5 6 7 8 9 10 1 1 1 2 1 3 1 4 3 2 1 Focus puller 2 Zoom puller 3 LED indicator 4 P ower LED 5 Network LED 6 Control button 7 I/O terminal block 8 Iris connector 9 P ower connector* 1 0 RS485/422 1 1 SD card slot (microSD) 12 Audio in 13 Audio out 14 Network connector P oE * Not used for -E versions.
AXIS P13 Series LED Indicators Note • The Status LED can be congured to be unlit during normal operation. To congure, go to Setup > System Options > P orts & Devices > LED . See the online help for more information. • The Status LED can be congured to ash while an event is active.
AXIS P13 Series Connectors and Buttons For specications and operating conditions, see page 13 . Network Connector RJ45 Ethernet connector with P ower over Ethernet (P oE). NO NO NO TICE TICE TICE The product shall be connected using a shielded network cable (STP).
AXIS P13 Series RS485/RS422 Connector Two terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment such as pan-tilt devices. SD Card Slot NO NO NO TICE TICE TICE • Risk of damage to SD card. Do not use sharp tools or excessive force when inserting or removing the SD card.
AXIS P13 Series P ower Consumption Products DC P oE AXIS P1354 8-28 V DC max 7.2 W IEEE 80 2.3af/802.3at Type 1 Class 3 AXIS P1357 8-28 V DC max 7.9 W IEEE 80 2.3af/802.3at Type 1 Class 3 Connectors I/O Connector 4–pin terminal block For an example diagram, see Connection Diagrams on page 16 .
AXIS P13 Series Audio Connector 3.5 mm audio connectors (stereo) 1 2 3 1 Tip 2 Ring 3 Sleeve Audio Input Microphone/Line in Ground Audio Output Line out (mono) Ground RS485/422 Connector Two 2-pin terminal blocks for RS485/RS422 serial interface.
AXIS P13 Series Connection Diagrams I/O Connector 1 2 3 4 1 0 V DC (-) 2 DC output 3.3 V, max 50 mA 3 Digital input 0 to max 40 V DC 4 Digital output 0 to max 40 V DC, open drain, 1 00 mA Install the Hardware Connect the Cables 1. Connect external input/output devices if required, such as alarm devices.
AXIS P13 Series - Connect an external power adapter to the power connector block. For wiring information, see page 14 . 5. Check that the indicator LEDs indicate the correct conditions, see LED Indicators on page 1 1 .
AXIS P13 Series 7. On the Focus page, click Fine-tune focus automatically and wait until automatic ne tuning is completed. 8. Click Enable iris . If the button is inactive the iris is already enabled. 9. If needed, make further adjustments under the Advanced tab .
AXIS P13 Series Reset to Factory Default Settings Important Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP address, to the factory default values. Note The installation and management software tools are available from the support pages on www .
Installation Guide V er . M2.2 AXIS P13 Series Date: June 20 15 © Axis Communications AB, 20 14 - 20 15 P art No. 1467 126.
An important point after buying a device Axis Communications P1354 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Axis Communications P1354 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Axis Communications P1354 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Axis Communications P1354 you will learn all the available features of the product, as well as information on its operation. The information that you get Axis Communications P1354 will certainly help you make a decision on the purchase.
If you already are a holder of Axis Communications P1354, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Axis Communications P1354.
However, one of the most important roles played by the user manual is to help in solving problems with Axis Communications P1354. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Axis Communications P1354 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center