Simer Pumps 3983

28 pages·1.7 MB·Water Pump·PDF·ENDEITNLJA
Simer Pumps 3983
Table of Contents 26 sections Installation/Operation/Parts · Installation/Fonctionnement/Pièces · Instalación/Operación/Piezas · Call 1-800-468-7867 · … ShowHide
Page 1 of the Simer Pumps 3983 user manual — Call 1-800-468-7867
Page 1 · click to enlarge
Page 1
Simer Pumps 3983 — Installation/Operation/Parts diagram (page 1)
Fig. 1 · Installation/Operation/Parts
Simer Pumps 3983 — Installation/Operation/Parts diagram (page 1)
Fig. 2 · Installation/Operation/Parts

293 Wright St., Delavan, WI 53115 Phone: 1-800-468-7867 Fax: 1-800-390-5351b Site: http://www.flotecwater.com

Simer Pumps 3983 — Installation/Operation/Parts diagram (page 1)
Fig. 3 · Installation/Operation/Parts

3983 3984 3985 3986 3988

Installation/Operation/Parts

Installation/Fonctionnement/Pièces

Instalación/Operación/Piezas

For further operating, installation, or maintenance assistance:

Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,

Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba:

Call 1-800-468-7867

Composer le 1 (800) 468-7867

Llame al 1-800-468-7867

English ...................... Pages 2-9

Français ............... Pages 10-17

Español ...............Paginas 18-25

SIM699 (Rev. 5/14/08)

Page 2 of the Simer Pumps 3983 user manual — C. Protect the electrical cords from sharp objects, hot
Page 2 · click to enlarge
Page 2

Specifications and Safety 2

DESCRIPTION This Submersible Sump Pump is designed for home sumps. The permanent split capacitor motor is oil filled, sealed for cooler running, and has automatic-reset thermal protection. Ball bearings on the motor shaft never need lubrication. The power cord is a 3-wire, grounding-type cord. SPECIFICATIONS Power supply 115V, 60 HZ., 15 Amp Circuit Liquid Temp. Range 32°F to 70°F(0°-21°C) Individual Branch Circuit Required (min.) 15 Amps Discharge: 1-1/2" Female NPT This pump is designed for use in a residential sump only. Pump water only with this pump. NOTICE: This unit is not designed as a waterfall or foun- tain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty. Do not use where water recirculates. Not designed for use as a swimming pool drainer. NOTICE: Read this Owner’s Manual for installation, operation, and safety information. GENERAL SAFETY INFORMATION Your automatic sump pump should give years of trouble-free service when correctly installed, main- tained, and used. However, interruption of power to the pump, dirt/debris in the sump, flooding that exceeds the pump’s capacity, electrical or mechanical failure in the pump, etc., may prevent normal pump operation. To help prevent damage from flooding, purchase a secondary AC sump pump, a DC backup sump pump, and/or a high water alarm. See the “Troubleshooting Chart” in this manual for informa- tion about common sump pump problems and reme- dies. For more information,call Simer customer service at 1-800-468-7867.

C. Protect the electrical cords from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking the cords. Replace damaged or worn cords. D. Do not lift the pump by the power cord.

Plastic pipe glue is extremely flammable. Follow the glue manufacturer’s instructions when assembling glued plastic pipe.

Burn hazard. Modern motors may run hot. Allow 20 minutes to cool before handling. 1. Know the pump application, limitations, and potential hazards. 2. Do not use this pump in water with fish present. 3. Drain the system completely before servicing it. 4. To prevent a flexible discharge line from whip- ping, which could cause injury or damage, fasten it down before starting the pump. 5. Before each use, check any hoses in the system for weakness or wear. Make certain that all con- nections are tight. 6. Periodically inspect the sump, the pump, and the piping for debris and foreign objects. Perform routine cleaning as required. 7. Personal Safety: a. Wear safety glasses at all times when working

with pumps. b. Keep your work area clean, uncluttered and

properly lighted; put away all unused tools and equipment. c. Keep visitors at a safe distance from the work

area. d. Make workshop child-proof with padlocks and

master switches. Remove any starter keys. 8. This pump installation must meet all applicable laws, codes, and ordinances. Tools Required: Pipe wrench, Strap Wrench, or Slip-Joint Pliers, Hacksaw, Screw Driver, File or Sandpaper Materials Required: 1-1/2" ABS or PVC Pipe with Cement to match Threaded Adapter (Pipe to Pump) Check Valve – Purchase a check valve that goes in the discharge line or in the pump discharge. If your check valve does not have a 1/8" anti-airlock hole, drill one in the discharge pipe just below the check valve. Be sure to install the check valve so that the flow will be away from the pump.

Hazardous voltage. To reduce the risk of hazardous or fatal electrical shock, follow instructions A through D, below: A. This pump has an approved 3-conductor power

cord with 3-prong, grounding-type plug. Connect the pump only to a properly grounded, 3-prong outlet. If the sump pump circuit has a 2-prong out- let, replace it with a grounded 3-prong outlet installed according to code. B. Unplug the pump before handling or servicing it.

If your basement floor is wet, turn off all power before walking on it. If the shut-off box is in the basement, call your electric company or hydro authority to shut off service to the house, or call your local fire department for instructions. After turning off the power, remove the pump for service.

Page 3 of the Simer Pumps 3983 user manual — Installation 3
Page 3 · click to enlarge
Page 3

Installation 3

Simer Pumps 3983 — Installation 3 diagram (page 3)
Fig. 4 · Installation 3

2D.To reduce noise and vibration, cut the discharge pipe near the pump and fasten a short length of rubber hose (1-7/8" (48 mm) I.D., e.g. radiator hose) into it with hose clamps.

10" Min. with Vertical Switch 18" Min. with Tethered Switch

1A. Minimum sump size: 10" (254mm) diameter by 10" (254mm) depth for vertical switch models; 14" (356mm) diameter by 18" (457mm) depth for tethered switch models. 1B. Construct the sump pit of tile, concrete, steel, or plastic; it must meet code requirements. 1C. No clay, earth, sand, or gravel in the sump (they will clog the pump). Keep the pump inlet screen clear.

3. Place the pump in the sump; make sure that nothing interferes with switch operation. For tethered switch models, the tether length should be 3-1/2" (See Figure 3).
Simer Pumps 3983 — Installation 3 diagram (page 3)
Fig. 5 · Installation 3

2A. Install the discharge plumbing and check valve, using teflon tape - NOT pipe joint compound. 2B. Tighten the pipe into the pump (hand tight + 1-1/2 turns). 2C. Install a check valve in the vertical pipe to prevent flow backwards through the pump when it shuts off. To prevent airlocking the pump, drill a 1/8" (3.2 mm) hole in the discharge pipe just above where it screws into the pump discharge. Install the check valve above this hole, but keep it as close to the pump as possible. Be sure the hole is below the waterline and below the check valve.

4. Finish installing the necessary plumbing. Follow the glue manufacturer’s instructions for safety precautions and curing time.

Risk of flooding. Make sure the pump can- not move in the sump. If the pump moves when it runs, the piping or sump wall may interfere with the switch and prevent the pump from starting or stopping.

Page 4 of the Simer Pumps 3983 user manual — Figure 5 Figure 6
Page 4 · click to enlarge
Page 4

Installation 4

Simer Pumps 3983 — Installation 4 diagram (page 4)
Fig. 6 · Installation 4

Figure 5 Figure 6

5A. Power Supply: This pump requires a 115 V., 60 Hz., 15 amp individual branch circuit. The cir- cuit must be grounded and should be dedicated to the sump pump. 5B. The pump is supplied with a 3-wire cord set with grounding-type plug. Plug the switch directly into the outlet and plug the pump into the opposite end of the switch’s plug.

6A. After you have installed the piping, check valve, and float switch, the pump is ready for operation. 6B. Check the pump by filling the sump with water and observing the pump’s operation through one complete cycle. For switch settings see the Electrical and Switch Specifications chart on Page 5.

Failure to make this operational check may lead to improper operation, premature failure, and flooding.

Electrical shock hazard. Always ground the pump to a suitable electrical ground, such as a grounded water pipe, a properly ground- ed metallic raceway, or a ground wire system. Do not cut off the round ground pin.

Page 5 of the Simer Pumps 3983 user manual — ELECTRICAL & SWITCH SPECIFICATIONS
Page 5 · click to enlarge
Page 5

Operation 5

1. The shaft seal depends on water for lubrication. Do not operate the pump unless it is submerged in water; running it dry may damage the seal. 2. If the pump overheats, an automatic-reset ther- mal protector cuts off the power and stops the motor before it can be damaged. The motor will automatically restart when it cools. If the protec- tor trips repeatedly, unplug the pump, remove it from the sump, and check it for the cause of the difficulty. Low voltage, long extension cords, clogged impeller, very low lift, a plugged or frozen discharge pipe, etc., can all cause cycling and overheating. 3. This pump will not remove all the water in the sump. If you are running the pump manually and water stops coming out of the discharge, the pump has probably run dry. Shut it off immedi- ately and check the water level.

PERFORMANCE

GPH AT TOTAL FEET OF LIFT (See Figure 7) Model5 ft.10 ft.15 ft.20 ft.No flow at height shown below CAPACITY GALLONS/HOUR 39834,0203,5403,0001,80026’ 39844,0203,5403,0001,80026’ 39854,3803,8403,3002,34028’ 39864,3803,8403,3002,34028’ 39884,7004,1003,5002,82029’
Simer Pumps 3983 — PERFORMANCE diagram (page 5)
Fig. 7

ELECTRICAL & SWITCH SPECIFICATIONS

ModelMotor HPMotor Full Load AmpsIndividual Branch Circuit Req.(Amps)*Switch Setting in inches Water Level For: OnOff 39831/35.81515"7" 39841/35.8156-1/2"3" 39851/26.31515"7" 39861/26.3156-1/2"3" 39883/47.0156-1/2"3"
Simer Pumps 3983 — ELECTRICAL & SWITCH SPECIFICATIONS diagram (page 5)
Fig. 8

TM E.I. DuPont De Nemours and Company Corporation, Delaware.

Simer Pumps 3983 — ELECTRICAL & SWITCH SPECIFICATIONS diagram (page 5)
Fig. 9

Figure 7 – LIFT: Lift is the vertical distance the pump actually lifts water.The higher the lift, the lower the flow.

Page 6 of the Simer Pumps 3983 user manual — 3983, 3984 3985, 3986 3988
Page 6 · click to enlarge
Page 6

Repair Parts 6

3983, 3984 3985, 3986 3988

Simer Pumps 3983 — 3983, 3984 3985, 3986 3988 diagram (page 6)
Fig. 10
Key No.Part Description Qty. 398339843985 1 2 3 •Power Cord Assembly 1 Impeller† 1 Tethered Float Switch Assembly 1 Vertical Float Switch Assembly 1PW17-281 PS5-33P FP18-15BD –PW17-281 PS5-33P – FPS17-66PW17-281 PS5-34P FP18-15BD –
Simer Pumps 3983 — 3983, 3984 3985, 3986 3988 diagram (page 6)
Fig. 11
Key No.Part DescriptionQty. 39863988 1 2 •Power Cord Assembly Impeller† Vertical Float Switch Assembly1 PW17-281 1 PS5-34P 1 FPS17-66PW17-281 PS5-22P FPS17-66
Simer Pumps 3983 — 3983, 3984 3985, 3986 3988 diagram (page 6)
Fig. 12
  • Not illustrated. NOTE: If motor fails, replace entire pump. † See Page 8 for impeller replacement instructions.
Page 7 of the Simer Pumps 3983 user manual — Troubleshooting 7
Page 7 · click to enlarge
Page 7

Troubleshooting 7

TROUBLESHOOTING CHART

Risk of electrical shock. Unplug the pump before touching it or servicing it.

SYMPTOMPROBABLE CAUSE(S)CORRECTIVE ACTION Pump won’t start or run.Pump is not plugged in. Blown fuse. Low line voltage. Defective motor. Defective float switch. Clogged or jammed Impeller. Obstructed float.Make sure the pump is plugged into a proper outlet. Replace the fuse with a fuse of proper size. Check the size of the wiring on the circuit feeding the pump and from the main switch on the property. If everything is OK, contact your power company or hydro authority. Replace the pump. Replace the float switch. If the impeller won’t turn, unplug the pump, remove the lower pump body, and locate the source of the binding. Replace the impeller if necessary. Move the pump in the sump or remove the obstruction. Pump starts and stops too often.Backflow of water from piping. Faulty float switch.Install or replace the check valve. Replace the float switch. Pump won’t shut off.Defective float switch. Restricted discharge (obstacle or ice in the piping). Obstructed float. Restricted intake screen.Replace the float switch. Unplug the pump, remove it from the sump, and clean the pump and piping. Move the pump in the sump or remove the obstruction. Unplug the pump, remove it from the sump, and clean the intake screen and impeller. Pump operates but delivers little or no water.Low line voltage. Debris caught in the impeller. Worn or defective parts or plugged impeller. Check valve installed without vent hole Restricted intake screen. Check valve is installed either backward or upside down.If the voltage is below 110 volts, check the size of the wiring from the main switch on the property. If OK, contact your power company or hydro authority. Remove the pump and clean out the impeller. Clean the impeller if it’s plugged; replace the impeller if necessary; otherwise replace the pump. Drill a 1/8" (3mm) dia. hole between the pump discharge and the check valve (1-2" above the pump discharge and below the waterline). Remove the pump and clean out the intake screen. Be sure the check valve is installed correctly (the flow arrow should point away from the pump).
Page 8 of the Simer Pumps 3983 user manual — Troubleshooting 7
Page 8 · click to enlarge
Page 8
Simer Pumps 3983 — Troubleshooting 7 diagram (page 8)
Fig. 13 · Troubleshooting 7

First: Turn off power to the pump, disconnect the dis- charge piping, and lift the pump out of the sump BY THE HANDLE ON TOP OF THE MOTOR (not by the cord).

3. Thread the new impeller onto the motor shaft as shown (left-hand thread – tightens to the left ).
1. Remove the three screws holding the motor to the base and lift the motor off the base.
4. Re-mount the motor on the base. Be sure to mount it so that the switch is clear of the discharge and all other obstructions in the sump.
2. Hold the motor shaft with a screwdriver and unscrew the impeller as shown. NOTE: The impeller has a left-hand thread, so it loosens to the right ( ) .

Last: Run the pump through one complete cycle after it is assembled and reinstalled. It should operate correctly and you should not hear any sounds of scraping or dragging from the pump.

4831 0205

Page 9 of the Simer Pumps 3983 user manual — General Terms and Conditions
Page 9 · click to enlarge
Page 9

Warranty 9

ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.

Simer Limited Warranty

SIMER warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in material or workmanship.

If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below.Your original receipt of purchase is required to determine warranty eligibility.

Exceptions to the Twelve (12) Month Warranty

Product/Model No. Warranty Period

M40P, M40,BW85P, CM10, CMK 90 days

2330, 2300, 2955, 2956, 2957, A5500 2 Years

4" Submersible Well Pumps, 3984, 3983, 2975PC, 2958, 3075SS 3 Years

Pre-Charge Water System Tank, 3986, 3985, 2956, 2960 5 Years

3988, 3995, 3997, 3963 Lifetime

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of SIMER, have been subject to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, mainte- nance or storage; nor to other than normal application, use or service, including but not limited to, operational failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.

Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to SIMER as soon as possible after the discovery of any alleged defect. SIMER will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty.

This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive remedy for defective products.

SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CON- TINGENT DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU- LAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential dam- ages or limitations on how long an implied warranty lasts, so the above limitations or exclu- sions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

  • SIMER
  • 293 Wright Street
  • Delavan, WI U.S.A. 53115 Phone: 1-800-468-7867/1-800-546-7867
  • Fax: 1-800-390-5351 E-Mail: info@<a href="http://simerpumps.com" rel="nofollow noopener" target="_blank">simerpumps.com</a>
  • Web Site: <a href="http://www.simerpumps.com" rel="nofollow noopener" target="_blank">http://www.simerpumps.com</a>
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump won’t start or run.Pump is not plugged in. Blown fuse. Low line voltage. Defective motor. Defective float switch. Clogged or jammed Impeller. Obstructed float.Make sure the pump is plugged into a proper outlet. Replace the fuse with a fuse of proper size. Check the size of the wiring on the circuit feeding the pump and from the main switch on the property. If everything is OK, contact your power company or hydro authority. Replace the pump. Replace the float switch. If the impeller won’t turn, unplug the pump, remove the lower pump body, and locate the source of the binding. Replace the impeller if necessary. Move the pump in the sump or remove the obstruction. p.7
Pump starts and stops too often.Backflow of water from piping. Faulty float switch.Install or replace the check valve. Replace the float switch. p.7
Pump won’t shut off.Defective float switch. Restricted discharge (obstacle or ice in the piping). Obstructed float. Restricted intake screen.Replace the float switch. Unplug the pump, remove it from the sump, and clean the pump and piping. Move the pump in the sump or remove the obstruction. Unplug the pump, remove it from the sump, and clean the intake screen and impeller. p.7
Pump operates but delivers little or no water.Low line voltage. Debris caught in the impeller. Worn or defective parts or plugged impeller. Check valve installed without vent hole Restricted intake screen. Check valve is installed either backward or upside down.If the voltage is below 110 volts, check the size of the wiring from the main switch on the property. If OK, contact your power company or hydro authority. Remove the pump and clean out the impeller. Clean the impeller if it’s plugged; replace the impeller if necessary; otherwise replace the pump. Drill a 1/8" (3mm) dia. hole between the pump discharge and the check valve (1-2" above the pump discharge and below the waterline). Remove the pump and clean out the intake screen. Be sure the check valve is installed correctly (the flow arrow should point away from the pump). p.7

Ask about the Simer Pumps 3983

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Simer Pumps 3983

Be the first to ask — other owners or our team will answer.

Original document

Simer Pumps 3983 manual PDF

28 pages·1.7 MB·Water Pump·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…