EN
Axis Communications logo
Official user manual

Axis Communications AXIS 83+

2 pages·4.1 MB·Home Theater Server·PDF·ENDEFRITNLJA
Axis Communications AXIS 83+
Table of Contents 24 sections AXIS 82 + & 83 + Developer Board & Device Server · Deploy your own embedded Linux applications · Programmable Device Server with Linux 2.4/2.6 · 100 MIPS performance · … ShowHide
Page 1 of the Axis Communications AXIS 83+ user manual — Programmable Device Server with Linux 2.4/2.6
Page 1 · click to enlarge
Page 1
Axis Communications AXIS 83+ — AXIS 82 + & 83 + Developer Board & Device Server diagram (page 1)
Fig. 1 · AXIS 82 + & 83 + Developer Board & Device Server

AXIS 82 + & 83 + Developer Board & Device Server

Axis Communications AXIS 83+ — AXIS 82 + & 83 + Developer Board & Device Server diagram (page 1)
Fig. 2 · AXIS 82 + & 83 + Developer Board & Device Server

Deploy your own embedded Linux applications

The AXIS 82+ Developer Board and AXIS 83+ Device Server are intended for the deployment of your own embedded Linux applications. With a sturdy industrial design, the hardware fits most deployment requirements.

Complete ‘ready-to-use’ product Supplied as a single printed circuit board as the AXIS 82+ Developer Board, or packaged within a durable aluminum casing in the AXIS 83+ Device Server, these otherwise identical products are equipped with external connectors for dual* 100 MBit Ethernet, USB, COM1, COM2, and RS-485 connection. They are also equipped with internal connectors that accommodate one parallel port and an additional serial port. Enclosed in a black aluminum casing, the AXIS 83+ Device Server is compliant with immunity, emission and safety standards, and is ready for immediate deployment into industrial and other environmentally hostile environments.

If your application is successful and you then want to progress to building your own product, Axis also supplies the ETRAX chip for use in your own custom product designs.

Partnership Development Axis is committed to open-source development and fully supporting its customers. Advanced technical support is available, as well as open discussion forums to facilitate good communication between the wide range of ETRAX system developers. Reference designs are available upon request.

Improve your time to market The AXIS 83+ Device Server is shipped as a ready-to-use device, which means that you spend no time at all on hardware development, authority approval testing, purchasing, or programming Ethernet addresses. Once your application is complete, the software is simply flash-loaded to the Device Server Platform, using FTP (File Transfer Protocol). With the AXIS 82+/83+ you are free to completely customize all software, including the Linux kernel.

Programmable Device Server with Linux 2.4/2.6

100 MIPS performance

Full source code available

Certified for industrial use

*Two Ethernet ports: Full 100 MBit Ethernet with secondary Ethernet port limited to 12 MBit.

Page 2 of the Axis Communications AXIS 83+ user manual — More information: developer.axis.com
Page 2 · click to enlarge
Page 2

AXIS 82 + Developer Board / AXIS 83 + Device Server

Technical Overview

RS485/422 Terminal Block

Operating Environment

  • Product-ready device server platform based on the AXIS ETRAX 100LX MCM 4+16 chip. The product ships with a pre-installed Linux operating system and pre-programmed Ethernet address. Full source code is available for all applications and drivers at developer.<a href="http://axis.com" rel="nofollow noopener" target="_blank">axis.com</a>
  • One RS485/422 serial port supported on a single screw terminal block. Supports baud rates up to 1843200 bps
  • Temperature: +5°C to +50°C
  • Humidity: 8-80% RHG, non-condensing

Product Warranty

Pinout: 1AC Power 2AC Power 3GND 4RS422 GND Connected to GND through 100 ohm resistor 5RX/TX-A Use pin 5 and 6 for 2-wire RS-485 6RX/TX-B Use pin 5 and 6 for 2-wire RS-485 7TX- 8TX+
  • A one-year warranty is included

The specifications below are appropriate to the AXIS 83+ Device Server (supplied with aluminum casing) only

Ethernet Network Connection

  • Primary Physical network connection on 10BaseT Ethernet or 100BaseTX Fast Ethernet networks using RJ45 twisted pair cable

Mechanical Design

  • Secondary Physical network connection on 10BaseT Ethernet or 100BaseTX Fast Ethernet, but limited in speed to 12 MBit/s since it is connected through an internal USB port. Actual routing speed is 4.5 MBit between the two interfaces
  • A stable aluminum casing that can be conveniently mounted on a wall (mounting brackets are included)

Metrics

Parallel port & General purpose I/O

  • An onboard I/O port, located on pin headers, can be used as either a standard parallel data port, or as a general purpose I/O control port
  • Height: 41 mm

Serial Connection

  • Width: 140 mm
  • Two RS232 serial ports terminated with 9 pin MALE D-SUB connectors, both ports support RXD, TXD, RTS, CTS, DSR, DTR, RI (not on COM1) and CD at baud rates up to 115200 bps
  • Length: 118 mm

USB 1.1 Port

  • Weight: 420 g
  • Compliant USB 1.1 (host) port for connection to USB cameras, Barcode scanners, Bluetooth, WiFi, etc.

Product Identification

Pinout: 1CD Carrier detect (Input) 2RxD Receive Data (Input) 3TxD Transmit Data (Output) 4DTR Data Terminal Ready (Output) 5GND Ground 6DSR Data Set Ready (Input) 7RTS Request To Send (Output) 8CTS Clear To Send (Input) 9RI Ring Indicator (Input)
  • Sticker label on the underside, which identifies the unit as an AXIS 83+ and also identifies the Ethernet address of the unit
  • The port can provide +5.0 VDC, 500 mA to the device

Application Flash-loading

Approvals*

  • AXIS 83+ Device Server compliant with both industrial and light industrial/commercial EMC standards for both emission and immunity
  • The customer’s Linux application can be flash loaded to the Device Server Platform over the network using FTP (File Transfer Protocol)

Hardware

  • Immunity Standards: EN 55024:1998 EN 61000-6-2:2001 EN 61000-6-1:2001
  • CPU: 32 bit RISC processor (AXIS ETRAX 100LX MCM 4+16)
  • One additional serial port is located on pin headers on the board and may be used for debugging
  • Flash memory: 8 Mbytes (4.5 Mbytes available for applications in default configuration).
  • Emission Standards: EN 55022:1998+A1 Class B (CISPR 22:1997+A1, Class B) FCC Part 15, Subpart B, Class A FCC Part 15, Subpart B, Class B EN 61000-3-2:2000 EN 61000-3-3:1995+A1
  • RAM: 32 Mbytes
Axis Communications AXIS 83+ — Hardware diagram (page 2)
Fig. 3 · Hardware

Power Supply

  • Power: 9-24 VAC (or DC), 9.6 VA, via external power supply (included) or on screw terminal block

24735/EN/R2/0505

  • Safety: EN 60950, UL (US version).
  • Power consumption typically between 2.8 VA and 3.2 VA. With load on USB Vbus, between 5.0 VA and 7.2 VA

*The approvals are made with the aluminum casing and cannot be guaranteed when the PCB is not mounted in a similar box

More information: developer.axis.com

©2003 Axis Communications AB. The Axis Communications logotype is a registered trademark of Axis Communications AB. All other company names and products are trademarks or registered trademarks of their respective companies. We reserve the right to introduce modifications without notice

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Axis Communications AXIS 83+

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Axis Communications AXIS 83+

Be the first to ask — other owners or our team will answer.

Original document

Axis Communications AXIS 83+ manual PDF

2 pages·4.1 MB·Home Theater Server·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…