Instruction/ maintenance manual of the product VSP 3001 Sierra
Go to page of 25
SIERA ELECTRONICS SOUND & SECURITY IP CAMERA INSTRUCTION MANUAL www .sieraelectronics.com SIERA ELECTRONICS SOUND & SECURITY VSP 3001 IP CAMERA.
Warning: Please read this manual carefully before using. Complete package should include the following items: AC adaptor 1 pc category 5 cross cable 1 pc I/O terminal cable 1 pc instruction 1 pc manua.
1 Introduction 2 1.1 technology support 1.2 system requirements 2 Panel description 3 2.1 front view 2.2 rear view 3 Installation 4 3.1 cautions 3.2 step 4 Illustration for net connection 5 4.1 onnect with PC directly by category 5 cable 4.2 connect to INTRANET through HUB/Switch 4.
1.1 Features Built-in web server , high quality JPEG image can be displayed through Internet browser upon connection with Ethernet. Motion JPEG can be up to 15 frames per second with high resolution 640x480. Through Internet, pan/tilt heads and lens can be conveniently controlled to meet with long-range monitoring.
3 2.1 Front view Lens Power indicator 2.2 Rear view Ethernet indicator I/O connector DC in jack 2 P ANEL DESCRIPTION Ethernet port.
3 INST ALLA TION 4 3.1 Cautions Please read all safety instructions carefully before installation. VSP-3001 IP camera should installed indoors generall y . The prolonged exposure under the sunlight or other strong lights shall accelerate the aging of the shell and shorten the using term.
4 ILLUSTRA TION FOR NET CONNECTION 5 He common connection programs for VSP-3001 network camera: 4.1 Connecting directly to PC(through category 5 cross cable) For this program, the page browsing requires the basic configuration as below for PC and IP camera: A Connect correctly with the IP camera as above illustration.
6 4.3 Connecting to Internet through HUB/Switch/Router For this program, not only the basic setup of PC and IP camera but also the setup of Port Forwarding function of Router is required, so the visit for network camera besides Intranet is accessible.
7 5 IP CAMERA P AGES 5.1 Home page There are 3 options on home page: 1) image browsing (single camera screen/multi camera screen) 2) configuration 3) help 5.
8 Enter user name and password of administrator and general user, then following dialogue box appears: click left operation bars to adjust the image directly: Brightness 17 levels Resolution 640 480 320 240 160 120 Quality favor clarity standard favor motion Image size x1 x2 5.
9 Enter user name and password of administrator, then setup page appears. network set up network parameters time set up date and time administrator set up user name and password of administrator gener.
10 5.4 N etwork Name of network camera 4-15 English characters and 2-7 Chinese characters Port no Assign IP address Assign DHCP Gateway Network camera management server Notes: please restart after click save to effect the settings you entered. The range is 1-65535(default:80).
11 5.5 Time item description settings remarks 1.current date and time (1) have the same time with PC (2) input by handwork yyyy-mm-dd for year 1970 to 2039. hh:mm:ss for 24h mode. Display current date and time of IP camera. Adjust internal clock T ake the internal clock of network camera with the same time of the PC.
12 5.6 Administrator [Authentication] [None]: anyone can access all pages. [administrator only]:for setup page [administrator]for setup page and [general user] for viewer page [user name and password]:user name should be 4-15 English words or 2-7 Chinese characters.
13 5.8 Image settings [brightness adjust] :17 levels, control the function for brightness adjustment. [Header display] : display the name of network camera and time on image or not. [Power line frequency] : 50HZ and 60HZ optional. Select correct power frequency and prevent fluorescent light interfering the image.
14 5.10 A larm trigger The alarm mode means the transmission of pre and/or post alarm images held in the buffer to specified address. Alarm: select enable to confirm the alarm mode function. [Alarm occur condition] : the alarm is subject to the rising or falling of voltage detected by the I/O connector.
15 Item Description Remarks IP address or host name of FTP server port number FTP method login ID Password upload file path over write setting 1 65535 Should not be blank, [”], ['], [#], [&], [%], [=], [+], [ ], [<], [>], [ ]. [FTP transfer] Start with / and end with / , Root directory: / (default).
16 5.11 Transfer image in the timer mode Timer mode means sending images to specified address when the clock reaches the pre-assigned time. [Timer] : select the function of transferring image in the timer mode or not. [Timer setting] : 8 timers is optional.
17 5.12 Background recording function Background recording means sending images to background FTP server for recording at specified intervals. [Record] : select the background recording function or not. [Image setting] : select the parameters of the image recorded in background.
18 6 RECORDING FUNCTION 6.1 Activex control recording ActiveX control recording function is for IE browser only, and can not for Netscape Navigator browser. Please right-click the mouse at the image and select the recording setting in the option box appeared when browsing.
19 7 I/O DESCRIPTION 7.1 About I/O The I/O connector controls input and output of signal, and it includes 1 I/O input terminal, 1 I/O output terminal and 1 RS-232 converter or half duplex RS-485 port. Port description: Port Name Description 1 AGND analog ground 2 485B/RXD 3 485A/TXD 4 DGND digital ground 5 +12V max.
20 Appendix 1: Reset to factory default In some case, we need reset the server to factory default which can operate on Setup Page. If the user can not login the Setup Page(such as forgetting the user name and the password), it will be available for resetting to factory default through ARP and PING to re-assign the IP address.
21 Display as below: C:>arp -d C:>arp -s 192.168.1.61 00-0c-e8-00-00-01 C:>ping -t 192.168.1.61 Pinging 192.168.1.61 with 32 bytes of data: Request timed out. Request timed out. Request timed out. Reply from 192.168.1.61: bytes=32 time=5ms TTL=255 Reply from 192.
22 Appendix 2: Troubleshooting can not access the network camera via browser the problem of Ethernet connection Please check the VSP-3001 network camera, the Hub, the Switch and Ethernet indicator. Check their connection if there is any abnormity. Disconnect the Ethernet connection, perform PING.
23 Appendix 3: Specification Hardware 100 levels are optional Brightness NTSC/PAL: 640x480, 320x240, 160x120 Ethernet(10 Base-T) TCP/UDP/IP , ARP , ICMP , HTTP , TFTP , T elnet, SMTP max.
An important point after buying a device Sierra VSP 3001 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sierra VSP 3001 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sierra VSP 3001 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sierra VSP 3001 you will learn all the available features of the product, as well as information on its operation. The information that you get Sierra VSP 3001 will certainly help you make a decision on the purchase.
If you already are a holder of Sierra VSP 3001, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sierra VSP 3001.
However, one of the most important roles played by the user manual is to help in solving problems with Sierra VSP 3001. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sierra VSP 3001 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center