User’s Guide
Java User’s Guide
Siemens Cellular Engines


Status Confidential / Released
GENERAL NOTES - EXCLUSION OF LIABILITY PRODUCT IS DEEMED ACCEPTED BY RECIPIENT AND IS PROVIDED WITHOUT INTERFACE TO RECIPI- ENT'S PRODUCTS. THE DOCUMENTATION AND/OR PRODUCT ARE PROVIDED FOR TESTING, EVALUA- TION, INTEGRATION AND INFORMATION PURPOSES. THE DOCUMENTATION AND/OR PRODUCT ARE PROVIDED ON AN "AS IS" BASIS ONLY AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. THE DOC- UMENTATION AND/OR PRODUCT ARE PROVIDED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, SIEMENS FURTHER DISCLAIMS ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, COMPLETENESS, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT OF THIRD-PARTY RIGHTS. THE ENTIRE RISK ARISING OUT OF THE USE OR PERFORMANCE OF THE PRODUCT AND DOC- UMENTATION REMAINS WITH RECIPIENT. THIS PRODUCT IS NOT INTENDED FOR USE IN LIFE SUPPORT APPLIANCES, DEVICES OR SYSTEMS WHERE A MALFUNCTION OF THE PRODUCT CAN REASONABLY BE EXPECTED TO RESULT IN PERSONAL INJURY. APPLICATIONS INCORPORATING THE DESCRIBED PROD- UCT MUST BE DESIGNED TO BE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS PROVIDED IN THESE GUIDELINES. FAILURE TO COMPLY WITH ANY OF THE REQUIRED PROCEDURES CAN RESULT IN MALFUNCTIONS OR SERIOUS DISCREPANCIES IN RESULTS. FURTHERMORE, ALL SAFETY INSTRUC- TIONS REGARDING THE USE OF MOBILE TECHNICAL SYSTEMS, INCLUDING GSM PRODUCTS, WHICH ALSO APPLY TO CELLULAR PHONES MUST BE FOLLOWED. SIEMENS OR ITS SUPPLIERS SHALL, REGARDLESS OF ANY LEGAL THEORY UPON WHICH THE CLAIM IS BASED, NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, DIRECT, INDIRECT, PUNITIVE OR OTHER DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUP- TION, LOSS OF BUSINESS INFORMATION OR DATA, OR OTHER PECUNIARY LOSS) ARISING OUT THE USE OF OR INABILITY TO USE THE DOCUMENTATION AND/OR PRODUCT, EVEN IF SIEMENS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING LIMITATIONS OF LIABILITY SHALL NOT APPLY IN CASE OF MANDATORY LIABILITY, E.G. UNDER THE GERMAN PRODUCT LIABILITY ACT, IN CASE OF INTENT, GROSS NEGLIGENCE, INJURY OF LIFE, BODY OR HEALTH, OR BREACH OF A CONDI- TION WHICH GOES TO THE ROOT OF THE CONTRACT. HOWEVER, CLAIMS FOR DAMAGES ARISING FROM A BREACH OF A CONDITION, WHICH GOES TO THE ROOT OF THE CONTRACT, SHALL BE LIMITED TO THE FORESEEABLE DAMAGE, WHICH IS INTRINSIC TO THE CONTRACT, UNLESS CAUSED BY INTENT OR GROSS NEGLIGENCE OR BASED ON LIABILITY FOR INJURY OF LIFE, BODY OR HEALTH. THE ABOVE PRO- VISION DOES NOT IMPLY A CHANGE ON THE BURDEN OF PROOF TO THE DETRIMENT OF THE RECIPI- ENT. SUBJECT TO CHANGE WITHOUT NOTICE AT ANY TIME. THE INTERPRETATION OF THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW WITHOUT REFERENCE TO ANY OTHER SUBSTANTIVE LAW.
Copyright Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its con- tents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.
Copyright © Siemens AG 2008
Trademark notice Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

1 Preface 11
2 Overview 12 2.1 Related Documents 12 2.2 Terms and Abbreviations 13
3 Installation 15 3.1 System Requirements 15 3.2 Installation CD for AC65/AC75 and XT65/XT75 16 3.3 Installation CD for TC65 17 3.3.1 Components 18 3.3.1.1 Module Exchange Suite 18 3.3.1.2 WTK 18 3.3.1.3 SDK / JDK 19 3.3.1.4 NetBeans IDE 5.0 19 3.3.1.5 NetBeans IDE 5.5.1 19 3.3.1.6 Eclipse 3.1.2 IDE and Eclipse ME Plugin 1.5.x 20 3.3.1.7 Eclipse 3.2.2 IDE and Eclipse ME Plugin 1.5.5 or 1.6.8 20 3.3.1.8 GPS Evaluation Software 21 3.3.1.9 Integrated Documentation Suite (IDS) 21 3.4 Set up Java Development Environment with Eclipse IDE (Quick Start-up) 22 3.5 Siemens Mobility Toolkit Installation 24 3.5.1 Installing the Standard Development Toolkit 24 3.5.2 Installing the SMTK Environment 24 3.5.3 Installing NetBeans IDE 5.0 / NetBeans IDE 5.5.1 26 3.5.4 Installing Eclipse 3.0, Eclipse 3.1 or Eclipse 3.2 26 3.5.5 Installing Borland JBuilder X, 2005 and 2006 Enterprise/Developer .. 27 3.5.6 Installing Module Exchange Suite (MES) 27 3.6 SMTK Uninstall 27 3.7 Upgrades 27
4 Software Platform 28 4.1 Software Architecture 28 4.2 Interfaces 29 4.2.1 ASC0 - Serial Device 29 4.2.2 General Purpose I/O 29 4.2.3 DAC/ADC 29 4.2.4 ASC1 29 4.2.5 Digital Audio Interface (DAI) 29 4.2.6 I2C/SPI 29 4.2.7 GPS 30 4.2.8 JVM Interfaces 31 4.2.8.1 IP Networking 31 4.2.8.2 Media 31

4.2.8.3 Other Interfaces 31 4.3 Data Flow of a Java Application Running on the Module 32 4.4 Handling Interfaces and Data Service Resources 33 4.4.1 Module States 33 4.4.1.1 State 1: Default – No Java Running 33 4.4.1.2 State 2: No Java Running, General Purpose I/O and I2C/SPI 34 4.4.1.3 State 4: Default – Java Application Active 34 4.4.1.4 State 5: Java Application Active, General Purpose I/O and I2C/SPI34 4.4.2 Module State Transitions 35
5 Maintenance 36 5.1 IP Service 36 5.2 Remote SIM Access 37 5.3 Power Saving 37 5.4 Charging 38 5.5 Airplane Mode 38 5.6 Alarm 38 5.7 Shutdown 39 5.7.1 Automatic Shutdown 39 5.7.2 Manual Shutdown 39 5.7.3 Restart after Switch Off 39 5.7.4 Watchdog 39 5.8 Special AT Command Set for Java Applications 40 5.8.1 Switching from Data Mode to Command Mode 40 5.8.2 Mode Indication after MIDlet Startup 40 5.8.3 Long Responses 40 5.8.4 Configuration of Serial Interface 40 5.8.5 Java Commands 41 5.8.6 AutoExec Function 41 5.9 System Out 41 5.9.1 Serial interfaces 41 5.9.2 File 42 5.9.3 UDP 42 5.10 GPIO 42 5.11 Restrictions 42 5.11.1 Flash File System 42 5.11.2 Memory 42 5.12 Performance 43 5.12.1 Java 43 5.12.2 Pin I/O 44 5.12.3 Data Rates on RS-232 API 44 5.12.3.1 Plain Serial Interface 45 5.12.3.2 Voice Call in Parallel 45 5.12.3.3 Scenarios with GPRS/EGDE Connection 45

5.12.3.4 Upload 46 5.12.3.5 Download 47 5.13 System Time 49
6 MIDlets 50 6.1 MIDlet Documentation 50 6.2 MIDlet Life Cycle 50 6.3 Hello World MIDlet 52
7 File Transfer to Module 53 7.1 Module Exchange Suite 53 7.1.1 Windows Based 53 7.1.2 Command Line Based 53 7.2 Over the Air Provisioning 53 7.3 Security Issues 54 7.3.1 Module Exchange Suite 54 7.3.2 OTAP 54
8 Over The Air Provisioning (OTAP) 55 8.1 Introduction to OTAP 55 8.2 OTAP Overview 55 8.3 OTAP Parameters 56 8.4 Short Message Format 57 8.5 Java File Format 58 8.6 Procedures 59 8.6.1 Install/Update 59 8.6.2 Delete 60 8.7 Time Out Values and Result Codes 61 8.8 Tips and Tricks for OTAP 61 8.9 OTAP Tracer 62 8.10 Security 62 8.11 How To 62
9 Compile and Run a Program without a Java IDE 64 9.1 Build Results 64 9.2 Compile 65 9.3 Run on the Module with Manual Start 65 9.4 Run on the Module with Autostart 66 9.4.1 Switch on Autostart 66 9.4.2 Switch off Autostart 66
10 Compile and Run a Program with a Java IDE 67 10.1 Eclipse 3.1.2 (with ME Plugin 1.2.3) 67 10.1.1 Setup a New Project 67
11 Debug Environment 72 11.1 Data Flow of a Java Application in the Debug Environment 72 11.2 Emulator 73

11.3 Java IDE 75 11.3.1 NetBeans IDE 5.0, NetBeans 5.5 or NetBeans 5.5.x 75 11.3.1.1 Switching Emulator to IMP-NG Emulator 76 11.3.1.2 Templates 77 11.3.1.3 Examples 78 11.3.1.4 Compile and Run 79 11.3.1.5 Starting Debug Session without Downloading Java Files ... 79 11.3.1.6 Displaying Java "System.out" in NetBeans IDE window 80 11.3.2 Eclipse 3.0 and Eclipse 3.1 81 11.3.2.1 Eclipse 3.0 81 11.3.2.2 Eclipse 3.1 81 11.3.2.3 Eclipse 3.2 81 11.3.2.4 Using Eclipse with ME Plugin up to Version 1.2.3 82 11.3.2.5 Using Eclipse with ME Plugin 1.5.x 83 11.3.2.6 Using Eclipse with ME Plugin 1.6.x 85 11.3.2.7 Import Example 86 11.3.2.8 Compile and Debug 87 11.3.2.9 Starting Debug Session without Downloading Java Files ... 89 11.3.3 Borland JBuilder X 91 11.3.3.1 Examples 92 11.3.3.2 Starting Debug Session without Downloading Java Files ... 93 11.3.4 Borland JBuilder 2005 and JBuilder 2006 Enterprise/Developer 94 11.3.4.1 Examples 95 11.4 Breakpoints 95 11.5 Switching Java “System.out” to IDE Debug Window 96 11.6 Important Information for Java Debugging on Windows Vista 97
12 Java Security 98 12.1 Secure Data Transfer 98 12.1.1 Create a Secure Data Transfer Environment Step by Step 100 12.2 Execution Control 103 12.2.1 Change to Secured Mode Concept 104 12.2.2 Concept for the Signing the Java MIDlet 105 12.3 Application and Data Protection 106 12.4 Structure and Description of the Java Security Commands 106 12.4.1 Structure of the Java Security Commands 107 12.4.2 Build Java Security Command 108 12.4.3 Send Java Security Command to the Module 109 12.5 Create a Java Security Environment Step by Step 110 12.5.1 Create Key Store 110 12.5.2 Export X.509 Root Certificate 110 12.5.3 Create Java Security Commands 110 12.5.4 Sign a MIDlet 112 12.6 Attention 112

13 Java Tutorial 113 13.1 Using the AT Command API 113 13.1.1 Class ATCommand 113 13.1.1.1 Instantiation with or without CSD Support 113 13.1.1.2 Sending an AT Command to the Device, the send() Method.. 114 13.1.1.3 Data Connections 115 13.1.1.4 Synchronization 117 13.1.2 ATCommandResponseListener Interface 117 13.1.2.1 Non-Blocking ATCommand.send() Method 117 13.1.3 ATCommandListener Interface 118 13.1.3.1 ATEvents 118 13.1.3.2 Implementation 119 13.1.3.3 Registering a Listener with an ATCommand Instance 120 13.2 Programming the MIDlet 121 13.2.1 Threads 121 13.2.2 Example 121
14 Differences to the TC45 123

Table 1: GPRS upload data rate with different number of timeslots, CS2 46 Table 2: GPRS upload data rate with different number of timeslots, CS4 46 Table 3: EDGE upload data rate with two timeslots, CS5 46 Table 4: EDGE upload data rate with two timeslots, CS9 46 Table 5: GPRS Download data rate with different number of timeslots, CS2 48 Table 6: GPRS Download data rate with different number of timeslots, CS4 48 Table 7: EDGE Download data rate with different number of timeslots, CS5 48 Table 8: EDGE Download data rate with different number of timeslots, CS9 48 Table 9: A typical sequence of MIDlet execution 51 Table 10: Parameters and keywords 56

Java User’s Guide Figures 10
Figure 1: Overview 12 Figure 2: Installation of Eclipse ME-Plugin 1.2.3: Dialog box Feature Updates 22 Figure 3: Installation of Eclipse ME-Plugin 1.2.3: Dialog box Updates sites to visit 22 Figure 4: Installation of Eclipse ME-Plugin 1.2.3: dialog box Search Results 23 Figure 5: Installation of Eclipse ME-Plugin 1.2.3: dialog box Restart Eclipse 23 Figure 6: Interface Configuration 31 Figure 7: Data flow of a Java application running on the module 32 Figure 8: Module State 1 33 Figure 9: Module State 2 34 Figure 10: Module State 4 34 Figure 11: Module State 5 34 Figure 12: Module State Transition Diagram 35 Figure 13: Test case for measuring Java command execution throughput 43 Figure 14: Test case for measuring Java MIDlet performance and handling pin-IO 44 Figure 15: Scenario for testing data rates on ASC1 45 Figure 16: Scenario for testing data rates on ASC1 with a voice call in parallel 45 Figure 17: Scenario for testing data rates on ASC1 with GPRS data upload 47 Figure 18: Scenario for testing data rates on ASC1 with GPRS data download 47 Figure 19: OTAP Overview 55 Figure 20: OTAP: Install/Update Information Flow (messages in brackets are optional) 59 Figure 21: OTAP: Delete Information Flow (messages in brackets are optional) 60 Figure 22: Create new Eclipse project: Create a J2ME MIDP Midlet Suite 67 Figure 23: Create new Eclipse project: New J2ME Project 67 Figure 24: Create new Eclipse project: Midlet Suite Properties 68 Figure 25: Create new Eclipse project: work area with new created project 68 Figure 26: Create new Eclipse project: Create a J2ME Midlet 69 Figure 27: Create new Eclipse project: Create a New J2ME Midlet 69 Figure 28: Create new Eclipse project: Edit some Java commands 70 Figure 29: Create new Eclipse project: Edit “deployed” path to Jar file 70 Figure 30: Data flow of a Java application in the debug environment 72 Figure 31: NetBeans IDE 5.0 - installed emulators 76 Figure 32: NetBeans IDE 5.0 - Switching to IMP-NG emulator 76 Figure 33: NetBeans IDE 5.0 - Selecting an IMP-NG MIDlet template (e.g. project “Test”) 77 Figure 34: NetBeans IDE 5.0 - selecting sample project “Hello World Sample” 78 Figure 35: NetBeans IDE 5.0 - confirmation of sample project “Hello World Sample” 78 Figure 36: NetBeans IDE 5.0 - add emulator option “-noload” (e.g. project “HelloSample”) 79 Figure 37: NetBeans IDE 5.0 - Displaying Java “System.out” in NetBeans IDE window 80 Figure 38: Eclipse – Display of different integrated emulators 82 Figure 39: Eclipse – J2ME platform 83 Figure 40: Eclipse with ME Plugin 1.5.0 – Display of different integrated emulators 84 Figure 41: Eclipse with ME Plugin 1.5.0 – J2ME platform 85 Figure 42: Eclipse – Project import 86 Figure 43: Eclipse - Example 86 Figure 44: Eclipse – Create package 87 Figure 45: Eclipse - Configuration 88 Figure 46: Eclipse - Configuration 89

Java User’s Guide Figures 10
Figure 47: Eclipse 3.2.x ME1.5.x and 1.6.x select System Java Thread for showing breakpoint line in Java source 90 Figure 48: JBuilder X – JDK settings 91 Figure 49: JBuilder X – Siemens Library 91 Figure 50: JBuilder X – Sample Projects 92 Figure 51: JBuilder X – Starting the debugging session 92 Figure 52: JBuilder X – Edit project properties for starting the emulator 93 Figure 53: JBuilder - Runtime Configuration 93 Figure 54: JBuilder 2006 Enterprise/Developer – JDK settings 94 Figure 55: JBuilder 2006 Enterprise/Developer – Siemens Library 94 Figure 56: JBuilder 2006 Enterprise/Developer – Sample Projects 95 Figure 57: Emulator configuration file “switching Java System.out to serial port” 96 Figure 58: Using Windows Vista: Set Eclipse.exe perament to "Run as administrator".. 97 Figure 59: Mode 1 – Customer Root Certificate does not exist 99 Figure 60: Mode 2 - Server Certificate and Certificate into module are identical 99 Figure 61: Mode 2 - Server Certificate and self signed root Certificate in module form a chain 100 Figure 62: Insert Customer Root Certificate 104 Figure 63: Prepare MIDlet for Secured Mode 105 Figure 64: Build Java Security Command 108

This document covers the full range of IMP-NG Java products from Siemens, currently includ- ing: 1. TC65 Module 2. TC65 Terminal 3. AC75/AC65 Module 4. XT75/XT65 Module
Differences between the products are noted in the particular chapters. Throughout the docu- ment, all supported products are referred to as ME (Mobile Equipment). For use in file, directory or path names, the string “” represents the actual name of a product, for exam- ple TC65. Screenshots are provided as examples and, unless otherwise stated, apply to all supported products.

The ME features an ultra-low profile and low-power consumption for data (CSD and GPRS), voice, SMS and fax. Java technology and several peripheral interfaces on the module allow you to easily integrate your application.
This document explains how to work with the ME, the installation CD and the tools provided on the installation CD.

List of documents referenced throughout this manual: [1] AT Command Set of your Siemens Wireless product [2] Hardware Interface Description of your Siemens Wireless product [3] Java doc \wtk\doc\html\index.html [4] IMP-NG, JSR228, Standard
For further documents see Chapter 3.2.

API Application Program Interface
ASC Asynchronous Serial Controller
CLDC Connected Limited Device Configuration
DAI Digital Audio Interface
DCD Data Carrier Detect
DSR Data Set Ready
GPIO General Purpose I/O
GPRS General Packet Radio Service
GPS Global Positioning System
HTTP Hypertext Transfer Protocol
IDE Integrated Development Environment
IDS Integrated Documentation Suite
Java ME™ Java Mobile Edition aka. J2ME
Java SE™ Java Standard Edition
JAD Java Application Description
JDK Java Development Kit
JVM Java Virtual Machine
LED Light Emitting Diode
MES Module Exchange Suite
MIDP Mobile Information Device Protocol
OTA Over The Air
OTAP Over The Air Provisioning of Java Applications
PDP Packet Data Protocol
PDU Protocol Data Unit
SDK Standard Development Kit
SMS Short Message Service
SMTK Siemens Mobile Toolkit
TCP Transfer Control Protocol
URC Unsolicited Result Code

URL Universal Resource Locator
VBS Visual Basic Script
Abbreviation Description · WTK Wireless Toolkit

The Siemens Mobility Toolkit (SMTK) requires that you have: 1. Windows 2000, Windows XP or Windows Vista1 installed 2. 110 Mbytes free disk space for SMTK 3. Administration privileges 4. Java 2 SDK, Standard Edition 1.4. To install the JDK version 1.4.2_09 provided, follow the instructions in Section 3.5.1 Java 2 SDK, Standard Edition 1.5 is required for TC65.
If a Java IDE such as NetBeans IDE 5.0, NetBeans IDE 5.5.11, Eclipse 3.0.1, Eclipse 3.0.2, Eclipse 3.1.0, Eclipse 3.1.1, Eclipse 3.1.2, Eclipse 3.2.x1, JBuilder X, 2005 or 2006 Enterprise/ Developer is installed, it can be integrated into the SMTK environment during the installation of the SMTK. To install one of the IDEs, follow the installation instructions in Section 3.5.3 and Section 3.5.4 respectively.
If you wish to access the module via USB ensure that the USB cable is plugged between the module’s USB interface and the PC. Unless already done, install the appropriate USB modem driver. To do so, use the "usbmodem.inf" file supplied with your Siemens module.

eclipseme.feature_1.2.3_site.zip (Eclipse ME Plugin 1.2.3) • EclipseME plugin 1.5.03

Some of the content can only be accessed after the installation.

3.3.1.1 Module Exchange Suite
The Module Exchange Suite allows the developer to access the Flash file system on the cellu- lar engine from the development environment over a serial interface. File transfers from PC to module are greatly facilitated by this suite.
The MES installation version can be found under Control Panel → Add or Remove Programs selecting the installed MES program and clicking on support information (e.g. version 1.00.0008).
WTK is the directory where all the necessary components for product specific Java application creation and debugging are stored.
The version of the installed WTK is stored under the root of the WTK directory in a text file. (e.g. C:\Program Files\Siemens\SMTK\\WTK\VersionWTK.txt)

This is software provided by SUN to support Java application development.
SMTK emulator uses the following JDK (stored in JavaSoft Registry key) for starting the Debug Agent: • Registry path: HKEY_LOCAL_MACHINE\SOFTWARE\JavaSoft\Java Development Kit\1.4 HKEY_LOCAL_MACHINE\SOFTWARE\JavaSoft\Java Development Kit\1.55
This is a Java IDE provided by SUN to support Java application development.
This is a Java IDE provided by SUN to support Java application development. NetBeans IDE 5.5.1 is only supported on TC65 CD.

Used JDK from IDE (e.g. selecting Eclipse menu Help → About Eclipse SDK → Configuration Details and look for "java.version" and "java.vm.version").
Used JDK from IDE (e.g. selecting Eclipse menu Help → About Eclipse SDK → Configuration Details and look for "java.version" and "java.vm.version").

The GPS Evaluation Software (u-center) was developed by u-blox AG, Switzerland. This soft- ware demonstrates the capabilities of global positioning system (GPS) part incorporated in the XT75 module.
The latest version of the GPS Evaluation Software (u-center) can be downloaded for free from the internet: http://www.u-blox.com/products/u_center.html
The installed GPS Evaluation Software Version can be read out after starting u-center and selecting:
u-center menu Help → About u-center... and looking for the u-center version: e.g. Version 4.00 Build Inside this dialog box you will find contact and support address as well.
Please make the following preparations before using the u-center tool together with XT75 (module with GPS support): Step 1:
Install u-center → GPS_Evaluation_SW\ucentersetup.exe (on XT75 CD) Step 2:
Switch to transparent GPS mode by using the AT command AT^SGPSS=1,1 Step 3:
Configure the connected COM port (ASC0 of the XT75 module) by using the u-center menu Receiver → Port and Receiver → Baudrate
Now the XT75 module and the u-center are ready for operation.
The Integrated Documentation Suite (IDS) is installed together with SMTK and can be accessed via index.html file under the directory “\IDS” with a browser. Another possibility to access IDS is by using the IMP-NG Java documentation “Javadoc” inside the IDE and selecting the hyperlink IDS placed inside the main menu of IMP-NG Javadoc.
Please keep in mind that the internal structure of JBuilder IDE does not support opening the IDS from inside the JBuilder IDE using hyperlinks.
A further hyperlink to IDS is located in the start menu of and can be selected via “Integrated Documentation Suite (IDS)”.

Java User’s Guide 3.4 Set up Java Development Environment with Eclipse IDE (Quick Start-up) 27 s
Please complete the following steps to set up your Eclipse Java development environment: Step 1:
Install JDK 1.4.2_09 → JDK 1.4\j2sdk-1_4_2_09-windows-i586-p.exe For TC65 install JDK 1.5.0_07 , if no JDK 1.5 or higher is installed on your machine. Step 2:
Install Eclipse 3.1.2 → Unzip from CD ("\Eclipse\eclipse-SDK-3.1.2-win32.zip") to "C:\Program Files\Eclipse" (Installation of Eclipse 3.2.2 to be employed with TC65 is completed in the same way.) Step 3:
Installation Eclipse ME plugin 1.2.3: (Installation of Eclipse ME plugin 1.6.8 to be employed with TC65 is completed in the same way) - Start Eclipse IDE - Select the default workspace suggested by Eclipse - Start ME plugin installer using Eclipse menu
Help → Software Updates → Find and Install.



Java User’s Guide 3.4 Set up Java Development Environment with Eclipse IDE (Quick Start-up) 27 s
- Select the path where Eclipse ME plugin is located on CD (EclipseMEplugin_123\ ")
and select „eclipseme.feature_1.2.3_site.zip"

- In the dialog box Verification, select Install All. - In the dialog box Install/Update, select Yes to restart Eclipse.

- Eclipse IDE is restarted. Please close Eclipse IDE before continuing with installation of
Step 4:
Installation of the product’s SMTK: - Start "setup.exe" from CD root path. - Choose the destination folder of Eclipse "C:\Program Files\Eclipse" in the dialog box
Select Eclipse Folder. - Select SMTK (e.g. C:\Program Files\Siemens\SMTK) in dialog box Destination Folder. - Use the the dialog box Select COM Port to specify the connection type for on-device
debugging and MES transfer (downloading the MIDlet to the module): a) Standard 19200 Modem: Choose the COM port and set the baud rate (e.g. 115200). b) USB modem: Select "Siemens AG WM USB Modem". Note that the USB modem has to be installed previously using Siemens "usbmodem.inf" file. - After that, MES will be installed without further user action. Please wait until setup is com-
plete. - Click Finish in the summary dialog to confirm the completed installation.
A detailed description of the SMTK installation is given in the following chapters.

The SMTK comes with an installation CD. The installation program automatically installs the necessary components and IDE integrations. Software can be uninstalled and updated with the install program. The next sections cover the installation and removal of the SMTK and the installation of the SDK and the supported IDEs.
1. The JDK version 1.4.2_09 is provided on the SMTK installation disk in the subdirectory “JDK 1.4”. To begin the installation, start the “j2sdk-1_4_2_09-windows-i586-p.exe“ and fol- low the instructions of the JDK setup procedure. If there is no JDK installed on the target machine the installation of the provided JDK will be offered automatically during the SMTK installation process. The JDK version 1.5.0_07 is provided and required for TC65. 2. Once the toolkit has been installed, the environment variable “path” can be altered to com- fortably use the JDK tools. This is not necessary for using the Siemens SMTK. 3. Open the Control Panel: - Open System. - Click on Advanced. - Click on the Environment Variables button. - Choose path from the list of system variables. - Append the path for the bin directory of the newly installed SDK to the list of directories
for the path variable.
Before you start the installation please make sure all applications, especially the IDEs are closed. 1. Insert the CD, start setup.exe. When the dialog box appears press the Next button. 2. You will be asked to read the license agreement. If you accept the agreement, press Yes to continue with the installation. 3. A file including special information about the installation and use of the SMTK is shown. Press Next to continue. 4. You will be asked to enter the path name where Eclipse 3.0.1, 3.0.2, 3.1.0, 3.1.1, 3.1.2 or 3.2.x6 is installed. Please type in the folder where Eclipse with the ME plugin is installed and press Next. If you have not installed Eclipse or do not want to integrate the SMTK into Eclipse, please press Next without typing in a selected folder. 5. The installation software checks for the Java SDK. If there is no SDK on the system the installation procedure now offers to install the provided JDK. If this step is refused, the setup process will not continue because a properly installed JDK is mandatory for using the SMTK environment. 6. At this point, the installation software checks for a Java IDE to be integrated with the SMTK. A Java IDE is not necessary to use the SMTK. The IDE installation can be done at any time even if the SMTK is already installed. To integrate the SMTK into the Java IDE run the SMTK setup program in maintenance mode again. However, you can continue the setup procedure and install the IDE installation later or cancel the setup program at this stage and restart it after installing one of the supported Java IDEs. In case you wish to install a Java

IDE please follow the instructions below and in Section 3.5.3. If no installed IDE is found the SMTK offers to install NetBeans IDE 5.0 and NetBeans Mobility package 5.0 (NetBeans 5.5.1 and NetBeans Mobility package 5.5.1 is distributed with TC65 CD). Alternatively, you can install the SUN IDE by following the instructions in Section 3.5.3. 7. If the SDK and one or more Java IDEs are found, you will be asked to choose which IDE you want integrated into the development environment. Once an IDE has been found and selected, press Next to continue. Ensure that your Java IDE is closed. 8. Select the folder where the SMTK will be installed. A folder will be suggested to you but you may browse to select a different one. 9. Choose the path that SMTK will appear under in the Start Menu. 10. In the next installation dialog box you will be asked to to create a Dial-up Network connec- tion for on-device debugging. This Dial-up Network connection can be configured either for the Standard 119200 bps Modem integrated in Windows or the USB modem. As a result, a Dial-up Network connection will be created named "IP connection for remote debugging" (the connection will be available after the entire installation of the SMTK environment). - If a Dial-up Network connection named "IP connection for remote debugging" is already
available for another Siemens IMP-NG product, you can choose to reconfigure the exist- ing connection by pressing Yes or leave it unchanged by pressing No. - If you have selected Yes or if there was no on-device connection before, check either
"Serial COM port for using the standard modem installation" or "USB COM port for using the USB modem installation". - If you have chosen the Standard 119200 bps Modem select the COM port number, click
Next. In the resulting dialog box select the baud rate and click Next again. - If you have chosen the USB modem the available USB modems will be listed. Choose
the "Siemens AG WM USB Modem" and click Next. Note: You can reconfigure the COM port for the Dial-Up Network connection any time after the installation by starting the SMTK setup in maintenance mode and selecting “Repair” mode. 11. Select the IP address used for IMP-NG on-device debugging and the UPD port number used for switching the Java “System.out” direction to serial port output. 12. A brief summary of all entries made is shown. Press Next to continue. 13. A status message box informs you that the Module Exchange Suite (MES) will be installed now. A separate MES setup wizard opens. Please follow the setup wizard’s instructions. 14. All necessary files will be copied from the CD into the target folder. 15. This is the final step. Again, a listing of all installed components appears. Please press Fin- ish to end the installation.
How to use the "Modify" or "Repair" mode: To open either mode click Control Panel → Add or Remove Programs. Select SMTK installa- tion and press “Modify” or “Repair”: Please keep in mind, that Windows system requires the same location of the installation CD, if you like to use “Modify” or “Repair” for the SMTK installation. The installer is searching for *.msi file and an installer message box will pop up, telling the user to locate the installation CD in the corresponding drive and path. If the installation CD is not located on the displayed drive and path, please insert the CD or copy the CD contents into the required location (drive and path).

The SunTM NetBeans IDE 5.5.1 is distributed with the TC65 CD. Please start "netbeans-5_5_1- windows.exe" for installation of SunTM NetBeans 5.5.1 and "netbeans_mobility-5_5_1-win- dows.exe" for installation of Mobility package of SunTM NetBeans IDE 5.5.1.
Eclipse 3.1.2 (CD directory “\Eclipse\”) and Eclipse ME Plugin 1.2.3 (CD directory “\EclipseME_123\”)7 or Eclipse ME Plugin 1.5.0 (CD directory “\EclipseMEplugin_150\”) are provided on the SMTK CD. The installation of Eclipse is shortly described in Section 3.4. 8
Eclipse can be freely downloaded from http://www.eclipse.org In order to use Eclipse with the ME the EclipseME plug-in is also needed. It can be downloaded from http://eclipseme.org
Using Eclipse 3.0.1 or Eclipse 3.0.2: A customized version of this plug-in (CD directory “\EclipseME_WM\”)9 for Eclipse 3.0.1 and 3.0.2 comes with SMTK. It is required to use this plug-in for Eclipse 3.0.1 and Eclipse 3.0.2, because EclipseME plugin 1.2.3 requires Eclipse 3.1.0 and later and not installable for the older Eclipse versions 3.0.1 and 3.0.2.
Using Eclipse 3.1.0, Eclipse 3.1.1 or Eclipse 3.1.2: Please use EclipseME plug-in 1.2.1 or 1.2.3 for Eclipse version 3.1.0, Eclipse 3.1.1 or Eclipse 3.1.2.
Using Eclipse 3.2. (only supported for TC65): Please use EclipseME plug-in 1.5.5 or 1.6.x. It is recommended to use Eclipse 3.2.2 with ME 1.5.5 for working with Java Debugging session.

Borland JBuilder can be purchased from http://www.borland.com/jbuilder There are also 30 days trial versions available on the website. Installation instructions can be found there.
The Module Exchange Suite (MES) is installed during the SMTK installation. If you would like to install the Module Exchange Suite separately, repair or remove it, please use the Module Exchange Suite (MES) setup.exe, which is located on the SMTK installation disk in the subdi- rectory “MES”.
The SMTK install package comes with an uninstall facility. The entire SMTK or parts of the package can be removed. To start the uninstall facility, open the Control Panel, select Add/ Remove Programs, select the desired SMTK, e.g. TC65 Software Development Kit and follow the instructions. The standard modem and Dial-Up Network connection (DUN) are uninstalled automatically, if no SMTK IMP-NG product is installed in parallel. The user will be asked for uninstall of standard modem and Dial-Up Network (DUN) in the case, that another SMTK IMP- NG product is installed.
The Module Exchange Suite (MES) is not uninstalled automatically with the SMTK. If you would like to uninstall the Module Exchange Suite (MES) as well, please run the MES uninstall facility. To run the uninstall program, open the Control Panel, select Add/Remove Programs, select Siemens Module Exchange Suite (MES) and follow the instructions.
Please keep in mind, that standard modem (or USB modem), Dial-Up Network connection and Module Exchange Suite (MES) are required for a proper work of SMTK on-device debugging.
Note for customers migrating from TC45 to TC65: If you uninstall the TC45 software after the installation of TC65 you need to run the TC65 SDK and MES setup in maintenance mode to restore several files required for TC65. To do so, open the Windows Control Panel, double-click Add or Remove Programs, select “TC65 Software Development Kit”, press the Change/Remove button and select Repair. In the same manner, reinstall the Siemens Module Exchange Suite (MES)" As an alternative, to avoid this step, remove the TC45 package, before installing TC65 SDK and MES.
The SMTK can be modified, repaired or removed by running the setup program on the Instal- lation CD.

In this chapter, we discuss the software architecture of the SMTK and the interfaces to it.
Output: status LEDs - Input: Emergency Button - One I2C/SPI Interface. - One Digital Analog Converter and two Analog Digital Converters. - Serial interface (RS-232 API): This standard serial interface could be used, for example,
with an external GPS device or a current meter. For detailed information see Section 4.2.

4.2.1 ASC0 - Serial Device
ASC0, an Asynchronous Serial Controller, is a 9-wire serial interface. It is described in [2]. With- out a running Java application the module can be controlled by sending AT commands over ASC0. Furthermore, ASC0 is designed for transferring files from the development PC to the module. When a Java application is started, ASC0 can be used as an RS-232 port or/and Sys- tem.out. Refer to [3] for details.
There are ten I/O pins that can be configured for general purpose I/O. One pin can be config- ured as a pulse counter. All lines can be accessed under Java by AT commands or a Java API. See [1] and [2] for information about usage and startup behavior.
There are two analogue input lines and one analogue output line. They are accessed by AT commands. See [1] and [2] for details.
The TC65 Terminal does not feature DAC interface.
ASC1 is the second serial interface on the module. This is a 4-pin interface (RX, TX, RTS, CTS). It can be used as a second AT interface when a Java application is not running or by a running Java application as RS-232 port or/and System.out.
The TC65 Terminal and products with GPS do not feature ASC1.
The ME has a seven-line serial interface with one input data clock line and input/output data and frame lines to support the DAI. Refer to [1] and [2] for more information.
TC65 Terminal does not feature a DAI interface.
There is a 4 line serial interface which can be used as I2C or SPI interface. It is described in [2]. The AT^SSPI AT command configures and drives this interface. For details see [1].

It is discouraged to use the forth possibility since it uses up a valuable ATCommand instance. Use Java API for non-transparent, use CommConnection for transparent GPS access. Trans- parent and non-transparent modes can not be used concurrently but it is possible and in some cases may be necessary to use AT commands concurrently with the Java API e.g. for GPS power saving modes. For details about AT command related GPS functionality see [1].
The usage of CommConnection for GPS access is very straight forward. Calling Connec- tor.open with port-id “gps0” opens a transparent channel to the GPS module. Then all protocols supported by the GPS hardware can be used.
The landmark store is persistent. The stores are saved to FFS under a:/lmstores/store_X.xml, where X is the number of the store (0 is the default store).
There can be 8 stores plus 1 default store each containing up to 100 landmarks in up to 8 cat- egories (“no category” also counts as a category). Using AddressInfo with the landmarks might decrease the maximum number of possible landmarks in a store, depending on the amount of AddressInfo data being used. An IOException indicates that a store is full.
There is only one store active at a time. The current store information is kept in RAM and only written to FFS when the application switches to a different store or terminates. Saving a store might take up to 45s! During this time period the VM is blocked, no processing can be done in parallel.
One of the examples that come with the product CD is a tracking application that uses the Java location API.
GPS is only supported in XT75/XT65.
Products with GPS do not feature ASC1. So System.out is set to “null” device by default (see Section 5.9).


Java ME, CLDC and MIDP were implemented by SUN. IMP-NG is a stripped down version of MIDP 2.0 prepared by Siemens and does not include the graphical interface LCDUI. Siemens developed additional APIs like the File I/O and the AT command API. Documentation for Java ME and CLDC can be found at http://java.sun.com/javame/ Documentation for the other APIs is found in [3].
IMP-NG provides access to TCP/IP similarly to MIDP 2.0.
Because the used network connection, CSD or GPRS, is fully transparent to the Java interface, the CSD and GPRS parameters must be defined separately either by the AT command AT^SJNET [1] or by parameters given to the connector open method, see [3].
The playTone method and the tone sequence player are supported. For optimum performance use notes in the range of 48 to 105. Tones outside this range are affected by audio hardware filtering (see [2]).
Media package is only supported in TC65. See [3].
Neither the PushRegistry interfaces and mechanisms nor any URL schemes for the Platform- Request method are supported. See [3].

Java User’s Guide 4.3 Data Flow of a Java Application Running on the Module 35 s

Figure 7: Data flow of a Java application running on the module.
The diagram shows the data flow of a Java application running on the module. The data flow of a Java application running in the debug environment can be found in Figure 29. The compiled Java applications are stored as JAR files in the Flash File System of module. When the application is started, the JVM interprets the JAR file and calls the interfaces to the module environment.

would, in turn, be attached to one of the AT parsers. - two instances of access to a serial interface, ASC0 and ASC1, through the CommCon-
nection API. Access to the control lines of these interfaces through CommConnection- ControlLines (TC65 only). - System.out over any serial interface or into the file system
The module can exist in the following six states in relation to a Java application, the serial inter- faces, GPIO and I2C/SPI. See [1] for information about the AT commands referenced. A state transition diagram is shown in Figure 11.
This section shows how Java applications must share AT parsers, GPIO pins and I2C/SPI resources. DAC, ADC and DAI are not discussed here. Color legend for the following figures:

This is the default state. The Java application is inactive and there is an AT interface with CSD on ASC0 as well as ASC1. The initial state of the pins is according to [4].


The Java application is inactive. There is an AT parser with CSD on ASC0 as well as ASC1. Up to ten I/O pins are used as general purpose I/O plus a I2C/SPI interface. The pins are con- figured by AT^SCPIN and AT^SSPI (refer [1]).

The Java application is active and ASC0 and ASC1 are used as System.out and/or CommCon- nection. Java instances of AT commands are connected to the available AT parsers. The Java application is activated with AT^SJRA (refer to [1]) or autostart.

The Java application is active and ASC0 and ASC1 are used as System.out and/or CommCon- nection. The Java application is activated with AT^SJRA. The I/O pins are configured with AT^SCPIN, the I2C/SPI interface with AT^SSPI. Refer to [1] for AT command details.




The basic maintenance features of the ME are described below. Explicit details of these func- tions and modes can be found in [1] and [2].
Some Java products feature the BearerControl class. This class provides bearer state informa- tion and a method to hang-up.

The module supports several power saving modes which can be configured by the AT com- mand AT+CFUN [1]. Power saving affects the Java application in two ways. First, it limits access to the serial interface (RS-232-API) and the GPIO pins. Second, power saving effi- ciency is directly influenced by the way a Java application is programmed.
When going to low power mode there always might be a transition time of around 10s till low power consumption state is reached.

Please refer to [1] and [2] for general information about charging. Charging can be monitored by the running Java application. The JVM is active in Charge mode and in Charge-Only mode if autostart is activated. Only a limited number of AT commands are available when the module is in Charge-Only mode. A Java application must be able to handle the Charge-Only mode and reset the module to reinstate the normal mode. See [2] for information about the Charge-Only mode. The Charge-Only mode is indicated by URC “^SYSSTART CHARGE-ONLY MODE”.
The main characteristic of this mode is that the RF is switched off and therefore only a limited set of AT commands is available. The mode can be entered or left using the appropriate AT^SCFG command. This AT command can also be used to configure the airplane mode as the standard startup mode, see [2]. The JVM is started when autostart is enabled. A Java appli- cation must be able to handle this mode. The airplane mode is indicated by URC “SYSSTART AIRPLANE MODE”. Since the radio is off all classes related to networking connections, e.g. SocketConnection, UDPDatagramConnection, SocketServerConnection, HTTPConnection, will throw an exception when accessed.
The ALARM can be set with the AT+CALA command. Please refer to the AT Command Set [1] and Hardware Interface Description [2] for more information. One can set an alarm, switch off the module with AT^SMSO, and have the module restart at the time set with AT+CALA. When the alarm triggers the module restarts in a limited functionality mode, the “airplane mode”. Only a limited number of AT commands are available in this mode, although the JVM is started when autostart is enabled. A Java application must be able to handle this mode and reset the module to reinstate the normal mode. The mode of a module started by an alarm is indicated by the URC “^SYSSTART AIRPLANE MODE”.

If an unexpected shutdown occurs, data scheduled to be written will get lost due to a buffered write access to the flash file system. The best and safest approach to powering down the mod- ule is to issue the AT^SMSO command. This procedure lets the engine log off from the network and allows the software to enter a secure state and save all data. Further details can be found in [2].
Appropriate warning messages transmitted by the ME to the host application are implemented as URCs. To activate the URCs for temperature conditions use the AT^SCTM command. Und- ervoltage and overvoltage URCs are generated automatically when fault conditions occur.
For further detail refer to the commands AT^SCTM and AT^SBC described in the AT Com- mand Set [1]. In addition, a description of the shutdown procedures can be found in [2].
The module can be switched off manually with the AT command, AT^SMSO or when using the TC65 Terminal by pressing the ignition key for a period of time (see [2]). In these cases the midlets destroyApp method is called and the application has 5s time to clean up and call the notifydestroy method. After the 5s the VM is shut down.
When the module is switched off without setting an alarm time (see the AT Command Set [3]), e.g. after a power failure, external hardware must restart the module with the Ignition line (IGT). The Hardware Interface Description [2] explains how to handle a switched off situation.
The Watchdog class allows to access the HW watchdog of the system from application level. Depending on the setting (at^scfg) the userware watchdog can do nothing, switch-off or reboot the system.
Watchdog class is only available in TC65.

Java User’s Guide 5.8 Special AT Command Set for Java Applications 49 s
For the full AT command set refer to [1]. There are differences in the behaviour AT commands issued from a Java application in comparison to AT commands issued over a serial interface.
Cancellation of the data flow with “+++” is not available in Java applications, see [1] for details. To break the data flow use breakConnection(). For details refer to [3].
After starting a module without autobauding on, the startup state is indicated over the serial interface. Similarly, after MIDlet startup the module sends its startup state (^SYSSTART, ^SYSSTART AIRPLANE MODE etc.) to the MIDlet. This is done via a URC to the AT Com- mand API instance which executes the very first AT Command from within Java. To read this URC it is necessary to register a listener (see [3]) on this AT Command API instance before passing the first AT Command.
The AT Command API can handle responses of AT commands up to a length of 1024 bytes. Some AT commands have responses longer than 1024 bytes, for these responses the Java application will receive an Exception.
If Java is running, the firmware will ignore any settings from these commands. Responses to the read, write or test commands will be invalid or deliver „ERROR“.

Refer to the AT command Set [1].
Under Java, the AutoExec function’s AT command execution has some restrictions (see [1] for details on the AutoExec function). If an AT command is executed, neither URC nor command response are indicated to the Java application. Therefore, it is recommended to use the AutoExec function under Java only with commands that shut down the module, e.g., with AT+CFUN=0,1, as a watch dog. Any other AT command execution should be implemented with Java means and the ATCommand class.
Any output printed to the System.out stream by a Java application can be redirected to one of the serial interfaces, a file, a "NULL" device (i.e. the output will be discarded) or a UDP socket for using the debugger from an IDE. The configuration can be done at any time using the AT command AT^SCFG (see [1] for details) and is non-volatile.
System.out can be written to any of the serial interfaces ASC0, ASC1 or USB. If System.out is redirected to one of the interfaces used for the Java CommConnection, the interface will be shared between System.out and the CommConnection. This will result in mixed output, if data is written to the CommConnections OutputStream and something is printed via System.out at the same time.
Using System.out and CommConnection on the same serial interface may be done if a device connected to the serial port is only transmitting data to the module. It is recommended to ensure already in the HW design that output from the module cannot be transferred to a con- nected device.

The System.out print can be redirected into log files within the module’s flash file system. The output will be written alternatingly into two files which can be concatenated afterwards to have a single log file.
Writing the output to a file will slow down the virtual machine. To reduce the impact of logging the output may be written first to a buffer before it is written to the file (buffered mode). The buff- ered output is written either if the buffer is filled or after 200 ms. If the buffer is not used (secure mode) the output is written directly to the file. Because excessive writing to the module’s flash file system decreases the life time of the flash memory, we recommend using the System.out to file redirection only during development phases.
Redirection to a UDP socket is used in conjunction with the debugger. UDP is used by default when using on-device-debugging (Chapter 10). This can be changed by editing the emulator’s ini-file.
If the output is redirected to an UDP socket, any changes of the System.out configuration are ignored while the Virtual Machine is running. The UDP Socket settings will not be stored in the module.
The GPIO Java API (classes: InPort, OutPort, InPortListener, StartStopPulseCounter, Limit- PulseCounter and LimitPulseCounterListener) is a replacement for the GPIO AT commands (AT^SPIO, AT^SCPIN, ...). Using these classes frees up AT command resources and improves performance. Both APIs can only be used alternatively. Of course the basic system character- istics of a poll interval of 4.6ms (in SLEEP mode up to 2.7s) for pin state change detection does also apply here.
GPIO Java API is only supported in TC65.
5.11.1 Flash File System
The maximum length of a complete path name, including the path and the filename, is limited by the Flash file system on the module to 124 characters. It is recommended that names of classes and files be distinguished by more than case sensitivity.
The CLDC 1.1 HI features a just-in-time compiler. This means that parts of the Java byte code which are frequently executed are translated into machine code to improve efficiency. This fea- ture uses up RAM space. There is always a trade off between code translation to speed up exe- cution and RAM space available for the application.

The performance study was focused on comparable performance values under various circum- stances.
This section gives information about the Java command execution throughput (“jPS”= Java statements per second). The scope of this measurement is only the statement execution time, not the execution delay (Java command on AT interface → Java instruction execution → reac- tion on GPIO).

The following Java instruction was used for calculation of the typical jPS: value = ( 2 x number of calculation statements ) /
( (1 / frequencyB ) - ( 1 / frequencyA ) );
The reference loop has the same structure as the measurement loop except that the measure- ment sequence is moved.
ME in IDLE mode / Not connected ~49000
Since only a small amount of Java code is executed in this test, it is easily optimized by the CLDC’s HI just-in-time compiler. More complex applications might not reach that execution speed.
State jPS-Value (mean) · CSD connection ~46000

The pin I/O test was designed to find out how fast a Java MIDlet can process URCs caused by Pin I/O and react to these URCs. The URCs are generated by feeding an input pin with an external frequency. As soon as the Java MIDlet is informed about the URC, it tries to regener- ate the feeding frequency by toggling another output pin.

The results of this test show that the delay from changing the state on the input pin to a state change on the output pin is at least around 50 ms, but that time strongly depends on the amount of garbage to collect and number of threads to be served by the virtual machine. Consequently, pin I/O is not suitable for generating or detecting frequencies.
For details about the software platform and interfaces refer to Chapter 4, "Software Platform". This section summarises limitations and preconditions for performance when using the inter- face CommConnection from package com.siemens.mp.io (refer to [3]).
The data rate on RS232 depends on the size of the buffer used for reading from and writing to the serial interface. It is recommended that method read (byte[ ] b) be used for reading from the serial interface. The recommended buffer size is 2kbyte. To achieve error free data trans- mission the flow control on CommConnection must be switched on: and , the same for the connected device.
Different use cases are listed to give an idea of the attainable data rates. All applications for measurement use only one thread and no additional activities other than those described were carried out in parallel.

Scenario: A device is connected to ASC0 (refer to Section 4.2.4). The Java application must handle data input and output streams. A simple Java application (with only one thread) which loops incoming data directly to output, reaches data rates up to 180kbit/s. Test conditions: hardware flow control enabled ( and ), 8N1, and baud rate on ASC0 set to 230kbaud (→ theoretical maximum: 184kbit/s net data rate).

Same scenario as in Section 5.12.3.1, but with a voice call added. The application reflects incoming data directly to output and, additionally, handles an incoming voice call. The data rates are also up to 180kbit/s. Test conditions: same as in Section 5.12.3.1.

The biggest challenges to the module performance are setting up a GPRS/EDGE connection, receiving data on javax.microedition.io interfaces and sending or receiving the data on the RS232 API with the help of a Java application.

The ME supports up to four uplink time slots for GPRS and up to two for EGDE. The Java appli- cation receives data over RS232 API and sends them over GPRS to a server.
Upload data rate with x timeslots Coding scheme 2 [kbit/s]
theor. Value1
% from theor. Value
theor. Value1
% from theor. Value
theor. Value1
% from theor. Value
theor. Value1
% from theor. Value
9 12 75% 15 24 63% 20 36 55% 16 48 33%
Upload data rate with x timeslots Coding scheme 4 [kbit/s]
theor. Value1
% from theor. Value
theor. Value1
% from theor. value
theor. Value1
% from theor. value
theor. Value1
% from theor. value
13 20 65% 22 40 55% 20 60 33% 13 80 16%
Upload data rate with x timeslots Coding scheme 5 [kbit/s]
2 timeslots theor. Value1
% from theor. Value
Upload data rate with x timeslots Coding scheme 9 [kbit/s]
theor. Value1
% from theor. Value


The data rate for downloading data over GPRS/EDGE depends on the number of assigned timeslots and the coding schemes given by the net. The ME supports up to four downlink time slots. For the measurements, the Java application receives data from the server over GPRS and sends them over RS232 to an external device.


The tables below show the download data rates that can be achieved if hardware flow control is enabled on the CommConnection interface and the port speed is set to 460800.
Download data rate with x timeslots Coding scheme 2 [kbit/s]
theor. Value 1
% from theor. Value
theor. Value1
% from theor. Value
theor. Value1
% from theor. Value
theor. Value1
% from theor. Value
11 12 91% 21 24 87% 29 36 81% 35 48 73%
Download data rate with x timeslots Coding scheme 4 [kbit/s]
theor. Value 1
% from theor. Value
theor. Value1
% from theor. value
theor. Value1
% from theor. value
theor. Value1
% from theor. value
17 20 85% 31 40 78% 35 60 58% 38 80 48%
Download data rate with x timeslots Coding scheme 5 [kbit/s]
theor. Value 1
% from theor. Value
theor. Value1
% from theor. Value
20 22 91% 78 89 87%
Download data rate with x timeslots Coding scheme 9 [kbit/s]
theor. Value 1
% from theor. Value
theor. Value1
% from theor. value
50 59 85% 184 236 77%

When Java starts up, it initializes its time base from the system’s real time clock. If the RTC is changed by AT command (AT+CCLK) later on, the Java time does not adjust. So, the time you get with (AT+CCLK) and the time you get with System.currentTimeMilis() may not necessarily be identical.

The Java METM Mobile Information Device Profile (MIDP) provides a targeted Java API for writ- ing wireless applications. The MIDP runs on top of the Connected Limited Device Configuration (CLDC), which in turn, runs on top of the Java METM. MIDP applications are referred to as MIDlets. MIDlets are controlled by the mobile device implementation that supports the CLDC and MIDP. Since IMP-NG is a subset of MIDP 2.0, IMP includes MIDlets. The MIDlet code structure is very similar to applet code. There is no main method and MIDlets always extend from the MIDlet class. The MIDlet class in the MIDlet package provides methods to manage a MIDlet’s life cycle.
MIDP and MIDlet documentation can be found at http://wireless.java.sun.com/midp/ and in the html document directory of the wtk, …\Siemens\SMTK\\wtk\doc\index.html
From this you can see that the commands AT^SMSO and AT+CFUN=x,1 should never be sent within the destroyApp() method. It is good practice to always call the notifyDestroyed() method at the end of your destroyApp method. And use the destroyApp method as single exit point of your midlet.

Application Management Software MIDlet
The application management software creates a new instance of a MIDlet.
The default (no argument) con- structor for the MIDlet is called; it is in the Paused state.
The application management software has decided that it is an appropriate time for the MIDlet to run, so it calls the MIDlet.startApp method for it to enter the Active state.
The MIDlet acquires any resources it needs and begins to perform its service.
The application management software no longer needs the applica- tion be active, so it signals it to stop performing its service by calling the MIDlet.pauseApp method.
The MIDlet stops performing its service and might choose to release some resources it cur- rently holds.
The application management software has determined that the MIDlet is no longer needed, or perhaps needs to make room for a higher priority application in memory, so it signals the MIDlet that it is a candidate to be destroyed by calling the MIDlet.destroyApp method.
If it has been designed to do so, the MIDlet saves state or user preferences and performs clean up.

Here is a sample HelloWorld program.
/** * HelloWorld.java */
package example.helloworld; import javax.microedition.midlet.*; import java.io.*;
public class HelloWorld extends MIDlet {
/** * HelloWorld - default constructor */ public HelloWorld() { System.out.println("HelloWorld: Constructor"); }
/** * startApp() */ public void startApp() throws MIDletStateChangeException { System.out.println("HelloWorld: startApp"); System.out.println("\nHello World!\n"); destroyApp(); }
/** * pauseApp() */ public void pauseApp() { System.out.println("HelloWorld: pauseApp()"); }
/** * destroyApp() */ public void destroyApp(boolean cond) { System.out.println("HelloWorld: destroyApp(" + cond + ")"); notifyDestroyed(); } }

The Module Exchange Suite allows you to view the Flash file system on the module as a direc- tory from Windows Explorer. Make sure that the module is turned on and that one of the mod- ule’s serial interfaces (ASC0, ASC1 or USB) is connected to the COM port that the Module Exchange Suite is configured to. The configured COM port can be checked or changed under Properties of the Module directory. Please note that the Module Exchange Suite can be used only if the module is in normal mode and the baud rate is configured to a fixed value of 460800, 230400, 115200, 57600, 38400 or 19200. While running the module with the Module Exchange Suite, subdirectories and files can be added to the flash file system of module. Keep in mind that a maximum of 200 flash objects (files and subdirectories) per directory in the flash file system of the module is recommended.
The directory is called “Module” and can be found at the top level of workspace “MyComputer”. To transfer a file to the module, simply copy the file from the source directory to the target direc- tory in the “Module → Module Disk (A:)”.
A suite of command line tools is available for accessing the module’s Flash file system. They are installed in the Windows System directory so that the tools are available from any directory. The module’s file system is accessed with mod:. The tools included in this suite are MESdel, MEScopy, MESxcopy, MESdir, MESmkdir, MESrmdir, MESport, MESclose and MESformat. Entering one of these commands without arguments will describe the command’s usage. The tools mimic the standard directory and file commands. A path inside the module’s file system is identified by using “mod:” followed by the module disk which is always “A:” (e.g. “MESdir mod:a:” lists the contents of the module’s root directory).
See Chapter 8 for OTA provisioning.

The developer should be aware of the following security issues. Security aspects in general are discussed in Chapter 12.
The serial interface should be mechanically protected.
The copy protection rules for Java applications prevent opening, reading, copying, moving or renaming of JAR files. It is not recommended that the name of a Java application (for example .jar) be used for a directory, since the copy protection will refuse access to open, copy or rename such directories.

OTA (Over The Air) Provisioning of Java Applications is a common practice in the Java world. OTAP describes mechanisms to install, update and delete Java applications over the air. The ME implements the Over The Air Application Provisioning as specified in the IMP-NG standard (JSR228).
The OTAP mechanism described in this document does not require any physical user interac- tion with the device; it can be fully controlled over the air interface. Therefore it is suitable for Java devices that are designed not to require any manual interaction such as vending machines or electricity meters.
To use OTAP, the developer needs, apart from the device fitted with the Java enabled module, an http server, which is accessible over a TCP/IP connection either over GPRS or CSD, and an SMS sender, which can send Class1, PID $7d short messages. This is the PID reserved for a module’s data download.

The Java Application Server (http Server) contains the .jar and the .jad file to be loaded on the device. Access to these files can be protected by http basic authentication.
The OTAP Controller (SMS Sender) controls the OTAP operations. It sends SMs, with or with- out additional parameters, to the devices that are to be operated. These devices then try to con- tact the http server and download new application data from it. The OTAP Controller will not get any response about the result of the operation. Optionally the server might get a result response over http.

There is a set of parameters that control the OTAP procedures. These parameters can either be set by AT command (AT^SJOTAP, refer to [1] during the production of the device, or by SM (see Section 8.4) during operation of the device in the field. None of the parameters, which are set by AT command, can be overwritten by SM.
Parameters Max. Length AT Keyword SM Install/update delete
JAD File URL 100 JADURL mandatory unused
Application Directory 50 APPDIR mandatory mandatory
HTTP User 32 HTTPUSER optional unused
HTTP Password 32 HTTPPWD optional unused
Bearer -- BEARER mandatory optional/P
APN or Number 65 APNORNUM mandatory for CSD optional/P
Net User 32 NETUSER optional optional/P
Net Password 32 NETPWD optional optional/P
DNS -- DNS optional optional/P
Notify URL 100 NOTIFYURL optional optional/P
SM Password 32 PWD optional optional

Parameters Max. Length AT Keyword SM Install/update delete
Ignore SM PID --
Hide HTTP authentica- tion parameters
--
The length of the string parameters in the AT command is limited (see Table 10), the length in the SM is only limited by the maximum SM length.
The minimum set of required parameters depends on the intended operation (see Table 10). “optional/P” indicates that this parameter is only necessary when a POST result is desired.
An OTAP control SM must use a Submit PDU with Class1, PID $7d and 8 bit encoding. As a fallback for unusual network infrastructures the SM can also be of Class0 and/or PID $00. The content of the SM consists of a set of keywords and parameter values all encoded in ASCII format. These parameters can be distributed over several SMs. There is one single keyword to start the OTAP procedure. For parameters that are repeated in several SMs only the last value sent is valid. For example, an SM could look like this:
OTAP_IMPNG PWD:secret JADURL:http://www.greatcompany.com/coolapps/mega.jad APPDIR:a:/work/appdir HTTPUSER:user HTTPPWD:anothersecret Second SM:
OTAP_IMPNG PWD:secret BEARER:gprs APNORNUM:access.to-thenet.net NETUSER:nobody NETPWD:nothing DNS:192.168.1.2 START:install
Delete operation:
OTAP_IMPNG PWD:secret APPDIR:a:/work/appdir START:delete
The first line is required: it is used to identify an OTAP SM. All other lines are optional and their order is insignificant, each line is terminated with an LF: '\n' including the last one. The key- words, in capital letters, are case sensitive. A colon separates the keywords from their values.

The values of APPDIR, BEARER and START are used internally and must be lower case. The password (PWD) is case sensitive. The case sensitivity of the other parameter values depends on the server application or the network. It is likely that not all parameters can be sent in one SM. They can be distributed over several SMs. Every SM needs to contain the identifying first line (OTAP_IMPNG) and the PWD parameter if a mandatory password has been enabled. OTAP is started when the keyword START, possibly with a parameter, is contained in the SM and the parameter set is valid for the requested operation. It always ends with a reboot, either when the operation is completed, an error occurred, or the safety timer expired. This also means that all parameters previously set by SM are gone.
Apart from the first and the last line in this example, these are the parameters described in the previous section. Possible parameters for the START keyword are: “install”, “delete” or nothing. In the last case, an install operation is done by default.
The network does not guarantee the order of SMs. So when using multiple SMs to start an OTAP operation their order on the receiving side might be different from the order in which they were sent. This could lead to trouble because the OTAP operation might start before all param- eters are received. If you discover such problems, try waiting a few seconds between each SM.
Example:
MIDlet-Name: MyTest MIDlet-Version: 1.0.1 MIDlet-Vendor: TLR Inc. MIDlet-Jar-URL: http://192.168.1.3/datafiles/MyTest.jar MIDlet-Description: My very important test MIDlet-1: MyTest, , example.mytest.MyTest MIDlet-Jar-Size: 1442 MicroEdition-Profile: IMP-NG MicroEdition-Configuration: CLDC-1.1

A suitable Manifest file for the JAD file above might look like:
Manifest-Version: 1.0 MIDlet-Name: MyTest MIDlet-Version: 1.0.1 MIDlet-Vendor: TLR Inc. MIDlet-1: MyTest, , example.mytest.MyTest MicroEdition-Profile: IMP-NG MicroEdition-Configuration: CLDC-1.1
8.6.1 Install/Update

When an SM with keyword START:install is received and there is a valid parameter set for the operation, the module always reboots either when the operation completed, an error occurred or the safety timer expired. If there is any error during an update operation the old application is kept untouched, with one exception. If there is not enough space in the file system to keep

the old and the new application at the same time, the old application is deleted before the down- load of the new one, therefore it is lost when an error occurs.If install/update was successful, autostart is set to the new application.

When an SM with keyword START: delete is received and there is a valid parameter set for this operation, the module reboots either when the operation completed, an error occurred or the safety timer expired. If there is any error the application is kept untouched. Autostart is not changed.

All HTTP packets (GET, POST) sent by the module contain the IMEI number in the User-Agent field, e.g.
This eases device identification at the HTTP server.

For easy debugging of the OTAP scenario, the OTAP procedure can be traced over the serial interface. The trace output shows details of the OTAP procedure and the used parameters. To enable the OTAP trace output use the AT command AT^SCFG, e.g. AT^SCFG=Trace/Syslog/OTAP,1
The serial interface on which you issue this command is then exclusively used for the OTAP tracer. All other functionality which is normally present (AT commands or CommConnection and System.out in Java) is not available when the tracer is on.
This feature is intended to be used during development phase and not in deployed devices.
This chapter is a step-by-step guide for using OTAP. 1. Do you need OTAP? Is there any chance that it might be necessary to update the Java application, install a new one or delete it? It could be that device is in the field and you can- not or do not want to update it over the serial line. If the answer is “yes” then read through the following steps, if the answer is “no” then consider simply setting the OTAP SMS pass- word to protect your system. Then you are finished with OTAP. 2. Take a look at the parameters (Section 8.3), which control OTAP. You need to decide which of them you want to allow to be changed over the air (by SMS) and which you do not. This is mainly a question of security and what can fit into a short message. Then set the “unchangeable” parameters with the AT command (AT^SJOTAP). 3. Prepare the http server. The server must be accessible from your device over TCP/IP. That means there is a route from your device over the air interface to the http server and back. When in doubt, write a small Java application using the httpConnection Interface to test it. 4. Prepare the JAR and JAD files which are to be loaded over the air. Make sure that these files conform to the requirements listed in Section 8.5 and that they represent a valid appli- cation which can be started by AT^SJRA. 5. Put the files (JAR and JAD) on the http Server. The files can either be publicly available or protected through basic authentication. When in doubt try to download the files from the server by using a common Web browser on a PC, which can reach your http server over TCP/IP. 6. Prepare the SM sender. The sender must be able to send SMs, which conform to Section 8.4, to your device. When in doubt try to send “normal” SMs to your device which can than be read out from the AT command interface. 7. Test with a local device. Send a suitable short message to your device, which completes the necessary parameter, sets and starts the operation. The operation is finished when the

device reboots. You can now check the content of the file system and if the correct jar and jad files were loaded into the correct location. 8. Analyze errors. If the above test failed, looking at your device’s behavior and your http serv- ers access log can give you a hint as to what went wrong: - Ιf the device did not terminate the running Java application and did not reboot, not even
after the safety timeout, either your SM was not understood (probably in the wrong for- mat) or it did not properly authenticate (probably used the wrong password) or your parameter set is incomplete for the requested operation. - If the device terminated the running Java application, but did not access your http server,
and rebooted after the safety timeout, there were most likely some problems when open- ing the network connection. Check your network parameters. - If the device downloaded the jad and possibly even the jar file but then rebooted without
saving them in the file system, most likely one of the errors outlined in Section 8.5 occurred. These are also the only errors which will return a response. They are posted to the http server if the jad file contains the required URL. 9. Start update of remote devices. If you were able to successfully update your local device, which is hopefully a mirror of all your remote devices, you can start the update of all other devices.

Java User’s Guide 9 Compile and Run a Program without a Java IDE 66 s
This chapter explains how to compile and run a Java application without a Java IDE.
A JAR file must be created by compiling an SMTK project. A JAR file will contain the class files and auxiliary resources associated with an application. A JAD file contains information (file name, size, version, etc.) on the actual content of the associated JAR file. It must be written by the user. The JAR file has the “.jar” extension and the JAD file has the “.jad” extension. A JAD file is always required no matter whether the module is provisioned with the Module Exchange Suite, as described in Section 7.1, or with OTA provisioning. OTA provisioning is described in Chapter 7.
In addition to class and resource files, a JAR file contains a manifest file, which describes the contents of the JAR. The manifest has the name manifest.mf and is automatically stored in the JAR file itself. An IMP manifest file for:
package example.mytest; public class MyTest extends MIDlet
includes at least:
Manifest-Version: 1.0 MIDlet-Name: MyTest MIDlet-Version: 1.0.1 MIDlet-Vendor: Siemens MIDlet-1: MyTest, example.mytest.MyTest MicroEdition-Profile: IMP-NG MicroEdition-Configuration: CLDC-1.1
A JAD file must be written by the developer and must include at least:
MIDlet-Name: MyTest MIDlet-Version: 1.0.1 MIDlet-Vendor: Siemens MIDlet-1: MyTest, example.mytest.MyTest MIDlet-Jar-URL: http://192.168.1.3/datafiles/MyTest.jar MIDlet-Jar-Size: 1408 MicroEdition-Profile: IMP-NG MicroEdition-Configuration: CLDC-1.1
A detailed description of these attributes can be found in [4].

The batch files for compiling and running the samples refer to master batch files in the …\Sie- mens\SMTK\<productname>\wtk\bin directory and use the system environment variables IMPNG_JDK_DIR and IMPNG_DIR. IMPNG_JDK_DIR points to the root directory of the installed JDK and IMPNG_DIR points to the root directory of the Siemens-SMTK--IMPNG installation. The installation process sets these environment variables. A mod- ification is usually not necessary. They may be modified as requested (e.g. when switching to a different JDK) via the advanced system properties.
Example: In your terminal program enter: AT^SJRA=a:/java/jam/example/helloworld/helloworld.jar If you prefer to start with .jad file: AT^SJRA=a:/java/jam/example/helloworld/helloworld.jad The Flash file system on the module is referenced by “a:”.
Depending on which file you specify the java application manager tries to find the correspond- ing file in the same directory. This search is not done by name, but by comparing the contained attributes. The first file which contains the same values for MIDlet-Name, MIDlet-Version and MIDlet-Vendor is used.

To disable the automatic start of a user application in a module these steps must be carried out:
Using the graphical “autoexec_off.exe” tool: 1. Connect the module to the PC 2. Make sure, that the module is switched off 3. Start the “Autoexec_Off” program 4. Select the COM-Port 5. Press the “AutoExec Off” button
Using the command line tool “cmd_autoexec_off.exe”: 1. Connect the module to the PC 2. Make sure, that the module is switched off 3. Start the command line tool “cmd_autoexec_off” with option (com1 up to com99 for com port selection)

Java User’s Guide 10 Compile and Run a Program with a Java IDE 71 s
The following description assumes that Eclipse 3.1.2 is installed from SMTK CD as described in Section 3.3.1.6
Step 1:

- Type in the used name (e.g. Project01) and path for the new project:


- Select e.g. TC65 Release 2 emulator:

- A new Java Project has been created:


- Select “Project01” and press and select “J2ME Midlet”:

- Fill in Midlet parameters (package directory, name of Java source file) and press
ish>:


Step 2:
Modify Java source file “printme.java” template:

This application prints the given line via ASC1 (default setting). Please keep in mind to add “notifyDestroyed();” in destroyApp() method. Please refer to Chapter 6 “MIDlets” for more details about Midlet life cycles.
Step 3:
Configure Jad file: - Double click on “Project01.jad” to open the editor and add “deployed\” path in Midlet Jar
URL edit line.


Step 4:
Create Jad and Jar file: - Select “Project01” - Open context menu of “Project01” and select Create Package from item J2ME - Jad and Jar file are be created under the “deployed” directory (default setting of Eclipse)
Step 5:
Download Jad and Jar file into the Flash File System of the module and start the Java appli- cation: Manual download and start of Java application: - Copy Jad and Jar files manually using MES (e.g MES Windows Explorer) into the module - Start the Java application by using at command “AT^SJRA=a:/Project01.jar” (e.g. using
ASC1) - The Java “System.out” is printed via ASC1 (default setting) and is displayed on terminal
programs (e.g. “Print this line.”).
Automatic download and start of Java application using IDE: - Open the context menu of “printme.java” and select Emulated J2ME Midlet from item Run
As. - The SMTK emulator downloads Jar and Jad file into the Flash File of the module (trans-
mission via MES port that was selected during installation) and automatically starts the Java application. - The Java “System.out” is printed via ASC1 (default setting) and is displayed on terminal
programs (e.g. “Print this line.”).
Further information about importing an existing Java project into Eclipse based on the “Hello World” example is described in Section 11.3.2.7.


In the debug environment the module is connected to a PC via a serial interface. This can be a USB or an RS232 line. The application can then be edited, built, debugged or run within an IDE on the PC. When running or debugging the MIDlet under IDE control it is executed on the module (on-device execution) not on the PC. This can be either debugging mode, where the midlet execution can still be controlled from the IDE (on-device debugging) or normal mode, where the midlet is copied to the module and started normally. This ensures that all interfaces behave the same whether debugging mode is used or not.

The ME emulator is part of the SMTK and is used as the controlling entity for on-device debug- ging. Some values can be configured in the file wtk/bin/WM_Debug_config.ini (see below note for TC65). The emulator is running fine without changes in WM_Debug_config.ini file, because the settings for the serial interface (COM port and baudrate) are configured during installation of SMTK.
Windows 2000:
e.g. "c:\Documents and Settings\<your login>\Application Data\
Siemens\SMTK\TC65_R3\WM_Debug_Config.ini" Windows XP:
e.g. "c:\Documents and Settings\<your login>\Application Data\
Siemens\SMTK\TC65_R3\WM_Debug_Config.ini" Windows Vista:
e.g. "c:\Users\<your login>\AppData\Roaming\
Siemens\SMTK\TC65_R3\WM_Debug_Config.ini"
In case the Application Data folder is not visible, it is possible to set the option to show hidden folders (choose Explorer menu Tool -> Folder option.. -> and select "show hidden folder").
This Dial-Up Network (DUN) connection is installed automatically together with a standard modem or selecting USB modem during installation of SMTK. The emulator uses always the COM port or USB modem settings configured for this Dial-Up Network connection.
You can use any of the three serial interfaces (ASC0, ASC1, USB) to connect with module, but you will lose the functionality which is normally present on the interface. Because of this loss and because of its speed it is recommended that the USB interface be used.
Please keep in mind, that if you like to use a USB modem connection, you have to install and configure that modem connection before starting SMTK installation manually and select Sie- mens USB modem during SMTK installation. The Dial-up Network will be installed and config- ured with USB modem during SMTK installation. There are some points to notice in case of using the USB interface in a debugging session. If you are starting a debugging session very quickly once again after end of a previous debugging session, the emulator is not able to select the USB interface and is selecting a standard modem connection. Please wait some seconds to avoid this operation system dependent problem, because the Windows operation system

needs some seconds to enable the USB port once again after the "IP connection for remote debugging" is closed.
If necessary, the IP addresses used for the debug connection can also be changed. This is done in the file "WM_Debug_config.ini". For details, see also the AT^SCFG command and its “Userware/DebugInterface” parameters described in [1]. Please keep in mind, that the IP address range 10.x.x.x is not supported for the configuration of debugging!
During installation of SMTK some new programs are installed for handling the debugging ses- sion in conjunction with the IDE. The installation routine of the SMTK doesn't change any con- figuration of an existing firewall on your PC.
In the case, that a firewall is installed on your PC and the local configured and used IP connec- tion (Dial-Up Network connection for debugging) is blocked or disturbed by this firewall, please configure the firewall or the Dial-Up Network connection manually to accept the new installed programs and the port or to use another port or contact your local PC administrator for help.

The SMTK is integrated into your Java IDE during installation. Please note that the IDE inte- gration is intended to create MIDlets suitable for the Java enabled module and for debugging using the emulator. JAR files used in the module must be configured according to the batch file examples given. If the SMTK install succeeded, you can easily switch between the Siemens environment and Standard-JDK environment, the special libraries/APIs and emulators are available, and AT commands can be sent to the module. Regular function of the IDE for non- Siemens projects is unchanged.
Using the debugger please keep in mind that the MIDlet-URL, included in the Jad file, has to indicate and store the location where the emulator will find the corresponding Jar file. Generally the location will only be the file name for the Jar file.
If you are using Eclipse IDE the location of the Jar file is “deployed\.jar”. Please check this path name inside the Jad file before starting a debugging session with Eclipse IDE and change it manually, if the “deployed” subdirectory is missing. Please keep in mind, that the subdirectory “deployed” is used as a default setting in the Eclipse IDE and can be changed by the user within the Eclipse menu.
While using "on-device debugging" the ME is restarted after the end of each debugging ses- sion. This is independent of the used IDE (Eclipse 3.0.1, Eclipse 3.0.2, Eclipse 3.1.0, Eclipse 3.1.1, Eclipse 3.1.2, Eclipse 3.2.x10, NetBeans IDE 5.0, NetBeans 5.5.x10, JBuilder X, JBuilder 2005, JBuilder 2006 Enterprise/Developer).
Please note that the USB port has to be disconnected manually before the module is restarted, in case of using a connected terminal program on USB port for directing the Java “System.out”. It is recommended to use ASC0 or ASC1 for directing Java “System.out” to avoid closing man- ually the COM port.
Please keep in mind, that it is not possible to use obfuscated files for a debugging session.
When writing and debugging a midlet be aware of the midlet life cycle (see Section 6.2 “MIDlet Life Cycle”).
Integration for NetBeans IDE 5.5 and 5.5.x is only supported for TC65. The described steps for using Netbeans IDE 5.0 are identical for NetBeans IDE 5.5 and Netbeans 5.5.x.
This section indicates the changes to your IDE you will see after integrating the SMTK and describes how to exploit these features to build and debug your applications. All installed emulators can be found using the NetBeans IDE 5.0 menu Tools → Java Platform Manager. See Figure 31.


You can switch to the SMTK emulator project dependent using the context menu for project properties (e.g. "Hello Sample" ) and select the emulator platform and the device e.g. “Siemens IMP-NG TC65 R2 Wireless Toolkit” and “IMP_NG_TC65_R2” for TC65 Release 2. See Figure 32.


Templates for a Siemens MIDlet can be found in the file explorer and under NetBeans IDE 5.0 menu File → New File... The MIDlet template provides the skeleton of an IMP-NG MIDlet appli- cation.
The New File wizard opens. Select category “IMP-NG” and File Type “IMP-NG MIDlet” and press the Next button for working with this skeleton.


There are three IMP-NG MIDlet sample projects (“HelloSample”, “NetDemo” and “RS232Sample”) included. Each sample project can be selected directly in NetBeans IDE 5.0. You can open the sample project (e.g. “HelloSample”) using the NetBeans IDE 5.0 menu File → New Project... The New Project wizard opens. Select Category Samples → Mobile → IMP- NG and select (e.g. “Hello World Example”). Press the Next button.


Press the Finish button to end the selection of the sample project. Note: Keep in mind, that if you are selecting the "HelloWorld-Sample" you have to choose the used emulator after loading the "HelloWorld-Sample". Please select project properties in the "HelloWorld" project’s context menu and choose the emulator (e.g. "TC65_R3") for the Java debugging session. Otherwise NetBeans 5.x indicates a reference problem, because it does not know, which kind of emulator has to be used!

Ensure that the proper emulator will be used and compile the project as normal. Any output will be shown in the output window in the IDE together with some debugging information of the IDE. The html help files of the SMTK can be accessed directly by pressing Alt+F1.
It is possible to start a debugging session without download of the Java files (*.jad and *.jar) again. The emulator has to be started with an additional parameter “-noload” and downloading of the Java files is suppressed.
If you like to suppress downloading of *.jar and *.jad file, please use the project context menu Properties, select category “Running” and type in “-noload” as extra parameter for the emulator as shown in the following figure:

Keep in mind that you have to remove this emulator option before starting debugging session with download of Java files. The Java files are not updated in the Flash Files System of the module while option “-noload” is set!

Please prepare redirection of Java “System.out” during a debugging session as described in Section 11.5 Switching Java “System.out” to IDE debug window.
The Debugging Console tab of the NetBeans IDE window is selected by default after starting the debugging session.
To display the Java “System.out”s after starting the debugging session select the “build.xml (debug)” tab as shown in the below figure:


We recommend that Eclipse 3.0.1 or higher is to be used.
Please use the customized Eclipse ME Plugin version that is distributed with the SMTK CD under the directory “EclipseMEplugin_WM” only for Eclipse 3.0.1 and 3.0.2 and install Eclipse ME as described in Section 3.4. However, instead of selecting "eclipseme.feature_1. 2.3_site.zip" choose “\EclipseMEpluging_WM\plugin.zip”12 from SMTK CD after clicking the New Archived Site… button.
If Eclipse is not installed, please follow the steps as described in Section 3.4. Please use and install EclipseME plugin 1.2.1, 1.2.3 or 1.5.x for Eclipse 3.1.0, 3.1.1 or 3.1.2.
If Eclipse is not installed, please follow the steps as described in Section 3.4. Please use and install EclipseME plugin 1.5.5 or 1.6.8.
It is recommended to use Eclipse 3.2.2 with ME 1.5.5 for working with Java Debugging session.

11.3.2.4.1 Additional Configuration of Integrated Emulator
The following configuration is displayed after SMTK integration into Eclipse by using the Eclipse menu Windows → Preferences → J2ME → Platform Components:

To use the debugger it is necessary to increase the debug server delay timeout of Eclipse IDE. Please set the timeout under Windows → Preferences → J2ME → Debug Server Delay to 25000. If you develop an extremely large application you may have to increase this timeout.

You can easily switch between different installed emulators by using the preferences of a project and choosing e.g. Siemens IMP-NG TC65 R2 Module, see figure below.

Eclipse ME Plugin 1.5.x is supported by the TC65, XT65/XT75 and AC65/AC75 CDs. This Eclipse ME Plugin is using a completely new device management concept to integrate different emulators. The integration and disintegration of the TC65 resp. XT65/XT75 or AC65/AC75 emulator is only automatically possible by using the TC65 resp. XT65/XT75 or AC65/AC75 SMTK CD!
Please note that selecting the TC65 resp. XT65/XT75 or AC65/AC75 emulator by using the Eclipse menu Window → Preferences → J2ME → Device Management → Import and brows- ing to the respective emulator directory will not integrate the emulator.

The following configuration is displayed after SMTK integration into Eclipse by using the Eclipse menu Windows → Preferences → J2ME → Device Management:

To use the debugger it is necessary to increase the debug server delay timeout of Eclipse IDE. Please set the timeout under Windows → Preferences → J2ME → Debug Server Delay to 25000. If you develop an extremely large application you may have to increase this timeout.

You can easily switch between different installed emulators by using the properties of a project and choosing a Device Group, e.g. "Siemens IMP-NG XT75 Wireless Toolkit". You can select a device also by using the Manage Devices… button, see figure below.

Automatic integration into Eclipse ME Plugin 1.6.x is supported by using the TC65 CD. All con- figurations, settings and using the Eclipse IDE are done in a very similar way as for Eclipse ME Plugin 1.5.x and are described in the Section 11.3.2.5.1 and Section 11.3.2.5.2.

You can import an existing Eclipse project using the following steps:
- Open menu: File → Import → Existing Project into Workspace - Choose the root directory of the Eclipse project (e.g. “Hello World” example of the SMTK
CD). See figure below.

The following figure shows the “Hello World” example in the IDE.

The html help files of the SMTK can be accessed directly by pressing Shift+F2 while the cursor points to a Java expression in a Java source file.

To build the jar and jad files you have rebuild the project with the Create Package function. Open the context menu of the project and go to J2ME → Create Package.

Now you are ready to debug your project. Run → Debug…
An emulator launcher with pre-settings is provided for starting the debugging session. Please ensure that you have selected the right project and executable midlet.
Note: Before starting Java debugging session with the HelloWorld-Sample it is recommended to check the setting of used emulator (e.g. TC65_R3 emulator in project properties see Section 11.3.2.5.2), to clean the project with configuration "automatically build" (using Eclipse menu Project → Clean…) and to compile it completely (using project’s context menu of the "Hel- loWorld" project select J2ME → Create Package).
Reason: Eclipse is storing internally old settings for an old used "HelloWorld-Sample", if you have used Eclipse with "HelloWorld-Sample" for another IMP-NG product before!


Restriction: The integration of the SMTK using the SMTK installer depends selecting the offered default workspace “\workspace” of Eclipse (e.g. Eclipse 3.0.1 and 3.0.2 “..\eclipse\workspace\..” or Eclipse 3.1.0, 3.1.1 and 3.1.2 “..\Documents and Settings\\workspace\..”).
If you like to use the SMTK integration inside other workspaces, please integrate SMTK man- ually in these workspaces using Eclipse menu Window → Preferences → J2ME → Platform Components (as shown in Figure 36). Please keep in mind that all manually integrated SMTKs have to be removed manually as well in case of removing SMTK.
Remarks using Eclipse under Windows Vista (only supported for TC65): The Eclipse workspace directory differs from the location used under Windows 2000 and Win- dows XP. Using Windows Vista the following loaction is used for automatic integration of TC65 into Eclipse: ":\Users\\AppData\workspace" (e.g. "c:\Users\\AppData\workspace")
Please select this workspace before starting Java debugging with Eclipse!

It is possible to start a debugging session without download of the Java files (*.jad and *.jar) again. The emulator has to be started with an additional parameter “-noload” and downloading of the Java files is suppressed. Please add the parameter in the following emulator configura- tion line as described in the figure:

Please keep in mind that you have to remove this emulator option before starting debugging session with download of Java files. The Java files are not updated in the Flash files system of the module while option “-noload” is set!
Please use Eclipse 3.2.2 ME 1.5.5 for starting debugging session with "-noload" parameter.

Note for using Eclipse 3.2.x ME 1.5.x and 1.6.x: During debugging it is sometimes possible, that if a breakpoint is reached, the Java program stops, but no breakpoint is indicated in the Java source line (Java source windows). In this case please select the Java Thread in the "Debug" window and select "System Thread" where the hit breakpoint is shown. The corresponding source line is highlighted inside the Java source windows (e.g. "HelloWorld.java") as well for the hit breakpoint. See the following figure.

Figure 47: Eclipse 3.2.x ME1.5.x and 1.6.x select System Java Thread for showing breakpoint line in Java source

If you want to use JBuilder X and it is not installed, first install JBuilder X and follow the instal- lation wizard instructions. Run the SMTK installation program in maintenance mode. The SMTK will find the installed JBuilder X IDE. Select JBuilder X to integrate the SMTK into JBuilder X.
After integration of SMTK into JBuilder X you can examine the integration by opening the menu Tools → Configure JDKs… (see Figure below).

The libraries included with the SMTK can be examined by opening the menu Tools → Configure Libraries… (see Figure below).


There are sample projects provided with the SMTK. These projects can be found in the JBuild- erSamples directory of the SMTK installation directory. This directory is accessed by opening a project using the menu File → Open Project… (see Figure below).

Open the Project (e.g. “HelloWorld.jpx”), rebuild the sources and start the debugger using the micro edition (context menu “HelloWorld.jad” → Micro Debug using “HelloWorld” ).


It is possible to start a debugging session without download of the Java files (*.jad and *.jar) again. The emulator has to be started with an additional parameter “-noload” and downloading of the Java files is suppressed. Please add the parameter in the following emulator running configuration line as described in the figures above.
Select the project properties (e.g. “HelloWorld.jpx”) and edit the emulator configuration.

Set the additional emulator parameter “-noload” and press OK.

Keep in mind, that you have to remove this emulator option before starting debugging session with download of Java files. The Java files are not updated in the Flash files system of the mod- ule while option “-noload” is set! The same procedure is used for all different JBuilder IDE versions.

If JBuilder 2005 or JBuilder 2006 Enterprise/Developer is not installed, run the JBuilder 2005 or JBuilder 2006 Enterprise/Developer install program and follow the installation wizard instruc- tions. Use the SMTK installation routine in maintenance mode. The SMTK will find the installed JBuilder 2005 or JBuilder 2006 Enterprise/Developer IDE. Select JBuilder 2005 or JBuilder 2006 Enterprise/Developer to integrate the SMTK into JBuilder 2005 or JBuilder 2006 Enter- prise/Developer.
After the integration of the SMTK into JBuilder 2005 or JBuilder 2006 Enterprise/Developer you can examine the integration by opening the menu Tools → Configure → JDKs… (see Figure below).

The libraries included with the SMTK can be examined by opening the menu Tools → Config- ure → Libraries… (see Figure below).


There are sample projects provided with the SMTK. These projects can be found in the JBuild- erSamples directory of the SMTK installation directory. This directory is accessed by opening a project using the menu File → Open Project… (see Figure below).

Starting the debugging session is done in the same way as for JBuilder X (see chapter for JBuilder X above).
Breakpoints can be set as usual within the IDE. The debugger cannot step through methods or functions whose source code is not available.

Java User’s Guide 11.5 Switching Java “System.out” to IDE Debug Window 97 s
The Java “System.out” can be redirected during a debugging session using a UDP socket con- nection as described in Section 5.9 “System Out” and Section 5.9.3 “UDP”. Switching between Java “System.out” using serial port and Java “System.out” using UDP socket is done by a set- ting inside of the emulator configuration file “WM_Debug_config.ini” (e.g. TC65 Release 2: located under “TC65_R2\WTK\bin”, TC65 Release 3: located Windows OS dependent under "Application Data" folder as described in Section 11.2). Switching Java “System.out” to serial port is used as default setting.

The following line of the “WM_Debug_config.ini” file is used for switching the Java “System.out” direction: #UDPport=12345
To switch the Java “System.out” direction to the UDP socket and display it on a IDE window please remove “#”. The configuration line looks as follows: UDPport=12345
To switch the Java “System.out” direction to serial port output please add “#” (default setting). The configuration line looks as follows: #UDPport=12345
Remarks: Please keep in mind that the handling of Java “System.out” is done asynchronous. It is possi- ble, that not all Java “System.out” data are written into the IDE window. To avoid this problem please set a breakpoint in front of the Java function call “notifyDestroyed()” inside your Java source.
Java “System.out” using IDE window is only supported during debugging session.

Java User’s Guide 11.6 Important Information for Java Debugging on Windows Vista 97 s
This section applies only to TC65.
Java Debugging on Windows Vista requires that administrator privileges be set. To do so, fol- low these steps: 1. Log on your system using an administrator account. 2. Start each IDE with option "Run as administrator" for starting Java debugging: - Temporarily: Right-click the IDE icon (on your desktop) and select "Run as administrator"
or - Permanently: Open the Windows Explorer and change the option for the IDE executable.
For example, right-click the "Eclipse.exe", select Properties and tab Compatibility, then select "Run this program as an administrator" in section "Privilege Level" (see figure below).

Please select this workspace before starting Java debugging with Eclipse! The automatic integration of TC65 is only done in this workspace.

The Java Security Model follows the specification of MIDP 2.0 and is IMP-NG conforming. It integrates only a simple protection domain concept since protection domains are not needed for module use cases.
Restrictions: • The module does not supply users independent date/time base. Therefore no examination of the validity of the expiration date/time of the certificate takes place.
This feature makes it possible for MIDlets to use safe data links to external communications partners. The specification IMP-NG defines two java classes with this characteristic - HTTPS- Connection and SecureConnection . The Siemens implementation follows the recommendations in IMP-NG:
HTTPSConnection • HTTP over TLS as documented in RFC 2818 and TLS Protocol Version 1.0 as specified in RFC 2246.
SecureConnection • TLS Protocol Version 1.0 as specified in RFC 2246

Two modes exist for safe data links.
Mode 1: • No examination of the server certificate takes place when setting up the connection. The authenticity of the server certificate is not verified. See Figure 59.




Figure 61: Mode 2 - Server Certificate and self signed root Certificate in module form a chain
The steps described below use the cygwin + openssl environment (for installation see http:// www.cygwin.com/ The openssl documentation can be found here http://www.openssl.org/ docs/apps/openssl.html)
A CA Root certificate is generated. This certificate can be placed on the HTTPS-Server. Another possibility is to use the private key of the certificate in order to sign thereby a server certificate. Both certificates form then a chain, which can be examined by the ME. A step-by- step description for the latter scenario can be found below.

certificate only. Add the parameter "-sha1" to the command "Making CA certificate ..." in the section of file CA.pl (cygwin location \cygwin\usr\ssl\misc”) - Create a shell (use location \cygwin\usr\ssl\misc) - Execute commands
>perl CA.pl –newca
- Convert file format from PEM to DER
CA certificate cacert.pem
>openssl x509 -in ./demoCA/cacert.pem -inform PEM -out ./demoCA/cacert.der -outform DER
CA private key file cakey.pem
>openssl pkcs8 -in ./demoCA/private/cakey.pem -inform PEM -out ./demoCA/private/cakey.der -outform DER -nocrypt -topk8
>keytool -genkey -alias server -keypass keypass -keystore customer.ks -storepass keystorepass -sigalg SHA1withRSA -keyalg RSA
The field “name” of the certificate is the domain name or the IP address of the server.
>keytool -certreq -alias server -file server.csr -keypass keypass -keystore customer.ks -storepass keystorepass
>openssl ca -in server.csr -out server.pem
- Convert file format from PEM to DER
>openssl x509 -in server.pem -inform PEM -out server.der -outform DER

12.5.3. - Execute command
>java -jar setprivatekey.jar -alias dummyca -storepass keystorepass -keystore customer.ks -keypass cakeypass -keyfile ./democa/private/cakey.der -certfile ./democa/cacert.der
java -jar getprivatekey.jar -alias server -keystore customer.ks -storepass keystorepass -keypass keypass -keyfile server_privkey.der
>openssl pkcs8 -in server_privkey.der -inform DER -out server_privkey.pem -outform PEM -nocrypt
Result:
- You have a keystore for the configuration of the Java Security of the module. - You have a signed server certificate (files “server.pem” or “server.der”). - You have a private key file for your server configuration (files "server_privkey.pem" or
"server_privkey.der. - The module contains the CA Root Certificat. - HTTPS certificate verification is activate.
Consult the documentation of your web server on how to set.up the certificate on it.
- Convert format

The Java environment of the ME supports two modes.
Unsecured mode: • The device starts all Java applications (MIDlets).
- The module changes into the mode “trusted” for MIDlet execution. “Untrusted Domain” is
OFF. - HTTPS certificate verification is OFF. - MES is ON. Remove the certificate:
- The module changes into the mode “untrusted” for MIDlet execution. - HTTPS certificate verification is OFF - MES is ON.

Create and insert a customer root certificate: A condition for the change to the secured mode is the existence of a customer root certificate inside of the module.

After this action the module is in the following conditions:
- The module changes into the mode “trusted” for MIDlet execution. “Untrusted Domain” is
OFF. - HTTPS certificate verification is OFF. - MES is ON.



In addition to the Java secured mode it is possible to prevent the activation of the Module Exchange Suite. When Module Exchange Suite access is deactivated with AT^SJSEC, it is no longer possible to access to the Flash file system on the module. A condition for the deactiva- tion of the access to the Flash file system is the existence of a customer root certificate inside of the module (see Section 12.2.1).
The default state of MES is ON.
Special commands are used in the Java security environment. These commands are trans- ferred to the module with the help of the special AT command AT^SJSEC. This command makes it possible to send binary data to the module. After AT^SJSEC is issued, the module changes into a block transfer mode. Now binary data in a fixed format can be sent. These binary data contain the actual Java security commands.

Java User’s Guide 12.4 Structure and Description of the Java Security Commands 112 s


Java User’s Guide 12.4 Structure and Description of the Java Security Commands 112 s


Java User’s Guide 12.4 Structure and Description of the Java Security Commands 112 s
Use a terminal program. Enter:
AT^SJSEC Wait for the answer:
CONNECT JSEC READY: SEND COMMAND ...
Now you can send the binary data of the command (for example: from a file with the binary data of the command).
The module’s answer depends on the result of the operation. The read command, AT^SJSEC?, can be used to request the current Java security status.
The read command can be used to request the current status of java secu- rity. Response ^SJSEC:,,, []
Java security mode
0 Unsecured mode, i.e. security mode not active (default) 1 Secured mode, i.e. security mode active
0 The HTTPS connection or Secure Connection is possible if the server certificate (or certificate chain) is valid (default) 1 The HTTPS Connection or Secure Connection is possible only if the server certificate is signed by the customer (owner of root certificate in device)
0 Start of Module Exchange Suite is not permitted 1 Start of Module Exchange Suite is permitted (default)
0 Untrusted domain does not exist, MIDlets must be signed (default) 1 Untrusted domain does exist, unsigned MIDlets have limited rights of access to the Java-API
Read command AT^SJSEC?

Java User’s Guide 12.5 Create a Java Security Environment Step by Step 112 s
12.5.1 Create Key Store
The key store contains the key pairs for signing data. For producing the key store with keys the tool “keytool.exe” can be used. The program is in the Java SDK. (for a description see http:// java.sun.com/j2se/1.3/docs/tooldocs/solaris/keytool.html). Example:
keytool -genkey -alias keyname -keypass keypassword -keystore customer.ks -storepass keystorepassword -sigalg SHA1withRSA -keyalg RSA
If you want to re-use the key store created in Section 12.1.1 you have to use the alias and pass- words used there.
For exporting the x.509 root certificate use “keytool.exe”. The program is in the Java SDK. (for description see http://java.sun.com/j2se/1.3/docs/tooldocs/solaris/keytool.html)
keytool -export -v -keystore customer.ks -storepass keystorepassword -alias keyname > certificate.der
For producing the java security commands the tool “jseccmd.jar” can be used. This program is in the folder “wkt\bin”.
Command for inserting the Customer Root Certificate
- In consequence of the command
java -jar jseccmd.jar -cmd SetRootCert -certfile certificate.der -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > SetRootCert.bin
Command for removing the Customer Root Certificate
- In consequence of the command all switches are reset
java -jar jseccmd.jar -cmd DelRootCert -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > DelRootCert.bin

Java User’s Guide 12.5 Create a Java Security Environment Step by Step 112 s
java -jar jseccmd.jar -cmd TrustedModeOn -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > TrustedModeOn.bin
java -jar jseccmd.jar -cmd TrustedModeOff -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > TrustedModeOff.bin
java -jar jseccmd.jar -cmd UntrustedDomainOn -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > UntrustedDomainOn.bin
java -jar jseccmd.jar -cmd UntrustedDomainOff -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > UntrustedDomainOff.bin
java -jar jseccmd.jar -cmd HttpsVerifyOn -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > HttpsVerifyOn.bin
java -jar jseccmd.jar -cmd HttpsVerifyOff -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > HttpsVerifyOff.bin
java -jar jseccmd.jar -cmd ObexActivationOn -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > ObexActivationOn.bin
java -jar jseccmd.jar -cmd ObexActivationOff -imei 012345678901234 -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks > ObexActivationOff.bin

Use the tool “jadtool.jar” to sign a Java MIDlet. This program is in the folder “wkt\bin”.
java -jar jadtool.jar -addjarsig -jarfile helloworld.jar -inputjad helloworld.jad -outputjad helloworld.jad -alias keyname -storepass keystorepassword -keypass keypassword -keystore customer.ks -encoding UTF-8
The central element of Java Security is the private key. If Java Security is activated and you lose the private key, then the module is destroyed. You have no chance of deactivating Java Security, downloading of a new Midlet or starting any other operation concerning Java Security. To prevent problems you are strongly advised to secure the private key.

This small tutorial includes explanations on how to use the AT Command API and suggestions for programming MIDlets. The developer should read about MIDlets, Threads and AT com- mands as a complement to this tutorial.
Perhaps the most important API for the developer is the AT command API. This is the API that lets the developer issue commands to control the module. This API consists of the ATCom- mand class and the ATCommandListener and ATCommandResponseListener interfaces. Their javadocs can be found in …\wtk\doc\html\index.html, [3].
The ATCommand class supports the execution of AT commands in much the same way as they would be executed over a serial interface. It provides a simple way to send strings directly to the device’s AT parsers.
There can be only exactly as many ATCommand instances as there are parsers on the device. If there are no more parsers available, the ATCommand constructor will throw ATCommand- FailedException. All AT parser instances support CSD. However from a Java application point of view it may make sense to have one dedicated instance for CSD call handling. Therefore, and also for historical reasons, only one parser with CSD support may be requested through the constructor. If more then one parser with CSD support is requested, the constructor will throw ATCommandFailedException.
ATCommand atc = new ATCommand(false); /* An instance of ATCommand is created. CSD is not explicitly * requested. */ } catch (ATCommandFailedException e) { System.out.println(e); }
The csdSupported() method returns the CSD capability of the connected instance of the device's AT parser. The method checks as well, if the current mode of the module supports CSD. Please notice that this check has not been done when opening the ATCommand instance.
boolean csd_support = atc.csdSupported();
release() releases the resources held by the instance of the ATCommand class. After calling this function the class instance cannot be used any more but the resources are free to be used by a new instance
try {

An AT command is sent to the device by using the send() method. The AT command is sent as a string which must include the finalizing line feed "\r" or the corresponding line end charac- ter.
String response = atc.send(“at+cpin?\r”); /* method returns when the module returns a response */ System.out.println(response);
This send function is a blocking call, which means that the calling thread will be interrupted until the module returns a response. The function returns the response, the result code of the AT command, as a string.
Occasionally it may be infeasible to wait for an AT command that requires some time to be pro- cessed, such as AT+COPS. There is a second, non-blocking, send function which takes a sec- ond parameter in addition to the AT command. This second parameter is a callback instance, ATCommandResponseListener. Any response to the AT command is delivered to the callback instance when it becomes available. The method itself returns immediately. The ATComman- dResponseListener and the non-blocking send method are described in Section 13.1.2.

If a data connection is created with the ATCommand class, for instance with ‘atd’, an input stream is opened to receive the data from the connection. Similarly, an output stream can be opened to send data on the connection.
/* Please note that this example would not work unless the module had * been initialized and logged into a network. */
if (response.indexOf("CONNECT") >= 0) { try { // We have a data connection, now we do some streaming... // IOException will be thrown if any of the Stream methods fail OutputStream dataOut = ATCmd.getDataOutputStream(); InputStream dataIn = ATCmd.getDataInputStream();
// out streaming... dataOut.write(new String("\n\rHello world\n\r").getBytes()); dataOut.write(new String("\n\rThis data was sent by a Java " + "MIDlet!\n\r").getBytes()); dataOut.write(new String("Press 'Q' to close the " + "connection\n\r").getBytes());
// ...and in streaming System.out.println("Waiting for incoming data, currently " + dataIn.available() + " bytes in buffer."); rcv = 0; while(((char)rcv != 'q') && ((char)rcv != 'Q') && (rcv != -1)){ rcv = dataIn.read(); if (rcv >= 0) { System.out.print((char)rcv); } } /* The example continues after the next block of text */

These streams behave slightly differently than regular data streams. The streams are not closed by using the close() method. A stream remains open until the release() method is called. A module can be switched from the data mode to the AT command mode by calling the break- Connection() method.
/* continue example */ if (rcv != -1) { // Now break the data connection System.out.println("\n\n\rBreaking connection"); try { strRcv = ATCmd.breakConnection(); } catch(Exception e) { System.out.println(e); } System.out.println("received: " + strRcv); } else { // Received EOF, somebody else broke the connection System.out.println("\n\n\rSomebody else switched to " + "command mode!"); } System.out.println("Hanging up"); strRcv = ATCmd.send("ATH\r"); System.out.println("received: " + strRcv); } catch(IOException e) { System.out.println(e); } } else { System.out.println("No data connection established,"); }
An IOException is thrown if any function of the I/O streams are called when the module is in AT command mode, except for read functions. The read function case is explained in more detail in Section 13.1.3. The ATCommand class does not report the result codes returned after data connection release.
For data connection signaling see also Section 13.1.3.

For performance reasons no synchronization is done in the ATCommand class. If an instance of this class has to be accessed from different threads ensure that the send() functions, the release() function, the cancelCommand() function and the breakConnection() function are syn- chronized in the user implementation.
The ATCommandResponseListener interface defines the capabilities for receiving the response to an AT command sent to one of the module's AT parsers. When the user wants to use the non blocking version of the ATCommand.send function of an implementation class of the ATCommandResponseListener interface must be created first. The single method of this class, ATResponse(), must contain the processing code for the possible response to the AT command sent.
class MyListener implements ATCommandResponseListener {
public MyListener(String awaited_response) { listen_for = awaited_response; }
void ATResponse(String Response) { if (Response.indexOf(listen_for) >= 0) { System.out.println("received: " + strRcv); } } }
After creating an instance of the ATCommandResponseListener class, the class instance can be passed as the second parameter of the non-blocking ATCommand.send() method. After the AT command has been passed to the AT parser, the function returns immediately and the response to the AT command is passed to this callback class later when it becomes available Somewhere in the application:
MyListener connect_list = new MyListener("CONNECT"); atc.send("ATD" + CALLED_NO + "\r", connect_list);
/* Application continues while the AT command is processed*/ /* When the module delivers its response to the AT command the callback * method ATResponse is called. If the response is "CONNECT", we will see * the printed message from ATResponse in MyListener. */
A running AT command sent with the non-blocking send function can be cancelled with ATCommand.cancelCommand(). Any possible responses to the cancellation are sent to the waiting callback instance.
String listen_for;

The user must create an implementation class for ATCommandListener to receive AT events. The ATEvent method of this class must contain the processing code for the different AT-Events (URCs). The RINGChanged, DCDChanged, DSRChanged and CONNChanged methods should contain the processing code for possible state changes. This code shall leave the lis- tener context as soon as possible (i.e. running a new thread). While the callback method does not return it cannot be called again if changes occur.
The CONNChanged method indicates the start and the end of data connections. During a data connection it is possible to transfer data with the I/O stream methods (see Section 13.1.1.3). Some data services (i.e. FTP) transfer the data so quickly, that the CONNChanged start and close events are received even parallel to the response of the AT command which originated the data connection. The user’s application must realize, that the data connection had taken place and read the data with the I/O stream read methods afterwards.
An ATEvent or a URC is a report message sent from the module to the application. An unso- licited result code is either delivered automatically when an event occurs or as a result of a query the module previously received. However, a URC is not issued as a direct response to an executed AT command. Some URCs must be activated with an AT command.
Typical URCs may be information about incoming calls, a received SM, temperature changes, the status of the battery, etc. A summary of URCs is listed in [1].

class ATListenerA implements ATCommandListener {
public void ATEvent(String Event) { if (Event.indexOf("+CALA: Reminder 1") >= 0) { /* take desired action after receiving the reminder */ } else if (Event.indexOf("+CALA: Reminder 2") >= 0) { /* take desired action after receiving the reminder */ } else if (Event.indexOf("+CALA: Reminder 3") >= 0) { /* take desired action after receiving the reminder */ } /* No action taken for these events */ public void RINGChanged(boolean SignalState) {} public void DCDChanged(boolean SignalState) {} public void DSRChanged(boolean SignalState) {} }
class ATListenerB implements ATCommandListener {
public void ATEvent(String Event) { if (Event.indexOf("+SCKS: 0") >= 0) { System.out.println("SIM Card is not inserted."); /* perform other actions */ } else if (Event.indexOf("+SCKS: 1") >= 0) { System.out.println("SIM Card is inserted."); /* perform other actions */ } } public void RINGChanged(boolean SignalState) { /* take some action when the RING signal changes if you want to */ }
public void DCDChanged(boolean SignalState) { /* take some action when the DCD signal changes if you want to */ }
public void DSRChanged(boolean SignalState {} /* take some action when the DSR signal changes if you want to */ }
public void CONNChanged(boolean SignalState {} /* take some action when the state of a connection changes if you want to */ } }

After creating an instance of the ATCommandListener class, it must be passed as a parameter to the ATCommand.addListener() method. The callback methods of the instance will be called by the runtime system each time the corresponding events (URCs or signal state changes) occur on the corresponding device AT parser.
/* we have two ATCommands instances, atc1 and atc2 */ ATListenerA reminder_listener = new ATListenerA(); ATListenerB card_listener = new ATListenerB(); atc1.addListener(reminder_listener); atc2.addListener(card_listener);
The ATCommand.removeListener() method removes a listener object that has been previously added to the internal list table of listener objects. After it has been removed from the list it will not be called when URCs occur. If it was not previously registered the list remains unchanged.
The same ATCommandListener may be added to several ATCommand instances and several ATCommandListeners may be added to the same ATCommand.

The life cycle and structure of MIDlets are described in Chapter 6. Since the MIDlets will run on Java METM, all of Java METM’s features, including threads, are available. Small applications, such as those without any timer functions or those used only for tests and simple examples, can be written without using threads. Longer applications should be implemented with threads.
Although small applications can be written without using threads longer applications should use them. The Java programming language is naturally multi-threaded which can make a substan- tial difference in the performance of your application. Therefore we recommend referring to Java descriptions on threads before making any choices about threading models. Threads can be created in two ways. A class can be a subclass of Thread or it can implement Runnable.
For example, threads can be launched in startApp() and destroyed in destroyApp(). Note that destroying Java threads can be tricky. It is recommended that the developer read the Java doc- umentation on threads. It may be necessary to poll a variable within the thread to see if it is still alive.
/* This example derives a class from Thread and creates two instances * of the subclass. One thread instance finishes itself, the other one * is stopped by the main application. */
package example.threaddemo; import javax.microedition.midlet.*; public class ThreadDemo extends MIDlet { /* Member variables */ boolean runThreads = true; // Flag for stopping threads DemoThread thread1; // First instance of DemoThread DemoThread thread2; // Second instance of DemoThread
/* Private class implementing the thread to be started by the * main application */ private class DemoThread extends Thread { int loops;
public DemoThread(int waitTime) { /* Store number of loops to execute */ loops = waitTime; System.out.println("Thread(" + loops + "): Created"); }
public void run() { System.out.println("Thread(" + loops + "): Started"); for (int i = 1; i

/* Print loop counter and wait 1 second, * do something useful here instead */ System.out.println("Thread(" + loops + "): Loop " + i); try { Thread.sleep(1000); } catch(InterruptedException e) { System.out.println(e); } } System.out.println("Thread(" + loops + "): Finished naturally"); } } /** * ThreadDemo - constructor */ public ThreadDemo() { System.out.println("ThreadDemo: Constructor, creating threads"); thread1 = new DemoThread(2); thread2 = new DemoThread(6); } /** * startApp() */ public void startApp() throws MIDletStateChangeException { System.out.println("ThreadDemo: startApp, starting threads"); thread1.start(); thread2.start(); System.out.println("ThreadDemo: Waiting 4 seconds before stopping threads"); try { Thread.sleep(4000); } catch(InterruptedException e) { System.out.println(e); } destroyApp(true); System.out.println("ThreadDemo: Closing application"); } /** * pauseApp() */ public void pauseApp() { System.out.println("ThreadDemo: pauseApp()"); } /** * destroyApp() */ public void destroyApp(boolean cond) { System.out.println("ThreadDemo: destroyApp(" + cond + ")"); System.out.println("ThreadDemo: Stopping threads from outsdide"); runThreads = false; try { System.out.println("ThreadDemo: Waiting for threads to die"); thread1.join(); thread2.join(); } catch(InterruptedException e) { System.out.println(e); } System.out.println("ThreadDemo: All threads died"); notifyDestroyed(); } }

Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.