Instruction/ maintenance manual of the product E12 Siemens
Go to page of 47
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 1 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Training Manual for In.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 2 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 This m anual was prepared for training purposes by Siemens AG for the project Siemens Automation Cooperates with Education (SCE).
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 3 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 PA GE 1. Preface ................................... ....................
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 4 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 The fo llowing symbols.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 5 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 1 PREFA CE Regarding its content, Module E 12 is part of the instruction unit ’IT Comm unication w ith S7’ .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 6 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Hardware and soft ware.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 7 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 2 NOTES ON USING T HE CPU 315F-2 PN/DP The CPU 315F-2 PN/DP is a CPU that is shipped wit h 2 integrated interfaces.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 8 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 3.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 9 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 3.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 10 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 3.5 Setting the Comm unication Interface of the VS120 to PROFINET First, switch on the power supply of the evaluati on device VS120 for the initi al startup.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 11 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 "Connect" M enu: The Ethernet IP mode has to be set to PNIO.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 12 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4 STARTING UP A PROJECT WIT H CPU 315F-2 PN/DP A ND VS120 Below, starting u p the VS120 in a project is described.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 13 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.1 Setting Up a New Project 1. The c entral tool in S T EP 7 is the ’SIMA TIC Manag er’ .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 14 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4. Next, highlight y our project and insert an ’Industrial Ethernet Subnet’ .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 15 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.2 Configuring t he Hardware 6. W ith a doubl e click , open the configuration tool for the ’Hardware’ .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 16 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 8. Now, from the hardware catalog select all m odules that are also inserted in y our actual rack and place them in the configuration table.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 17 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 9. Next, we drag the ’CPU 315F-2 PN/DP’ to t he second slot. The CPU’s order num ber and the version are provided on the front of the CPU.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 18 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Notes regarding netw .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 19 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 11. Next, we drag the input module for 16 inputs to the 4th slot. The module’s order num ber is inscribed on the front.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 20 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 12. Then, we drag the output module for the 16 outputs to the 5th slot. The module’s order num ber is inscribed on the front.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 21 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 14.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 22 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 16. Now double click on the control by te of the inserted m odule and change the address of the inputs to 10 and of the outputs to 20.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 23 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.3 A ssigning the Dev ice Name 18. Highlight module VS120 a nd then select, via the menu “Destination system“, at Ethernet ’A ssign device name’ .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 24 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 20. By clicking on ' ’, we can now load the hardware configuration into th e PLC.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 25 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.4 Inserting Blocks and FB1 and DB10 int o the Project From the template directory or from the Im age Process ing Sy stem SIMATIC VS120 V2.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 26 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 FB1 Input Parameters .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 27 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 FB1 Output Parameters.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 28 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.6 Operating FB1 Mo del Selection • To select a m odel, the DISA bit has to be set to 1.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 29 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.7 FB1 Error Information If an error occ urs, ERROR = 1 is set. The exact c ause for the error is indicated in ERRCODE.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 30 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Structure of the DB10.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 31 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.9 Supplementing t he Symbol Table Open the sy m bol table and enter the follow ing sy m bol assignm ents.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 32 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 The input/output addresses of the VS120 (hardware) have to be entered at th e firs t four input parameters of FB1.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 33 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 4.11 Calling F C10 in OB1 Double click on OB1. Enter sy m bolic name and symbol com m ent.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 34 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 5. WEB SERVER BA SED OPERA TOR INT ERFA CE OF VS120 5.1 Setting Up and Evalu ating the M odel Open the Internet browser.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 35 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Click on Set up Sensor . On the left of the interface, you w ill see a selection of tasks in the form of buttons.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 36 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Click on the button Set up . Here, we specify the param eters for image pick up and image evaluation.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 37 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Now click on the button Connections . Then click on the tab Integration or on the button Continue .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 38 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Then click on the button Continue , set the param eters and draw a circular ROI (Region of Interest) around the part.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 39 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Under the tab Test , the trained part is tested. Click on the button Continue .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 40 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Under the tab Save , save the model with the na m e Part1. Now click on the button Evaluate and start the evaluation m ode.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 41 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Evaluatio n result: Faulty p art with the Number 1 is too large and milling is crooked.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 42 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 5.2 Setting Up the M odel Set and Evaluating th e Mod el Number Several models are to be trained and combined into a set.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 43 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Parts 1 to 5 are to be combined into one model set. Click on the button Options .
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 44 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Now click on the button Evaluate and start the evaluation m ode. Set the CPU to Run and start image evaluation w ith “ Start “ (I0.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 45 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 Even if the number is faulty, a parts assignment is still made by means of the shape.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 46 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 6 RESULTS OF IM AGE EV ALUA TION IN THE CPU 6.1 Web View of th e Evaluation 6.
Industry A utomation and Drive T echnologies - SCE TIA Training Document Page 47 of 47 Module E12 Status: 01/2010 Vis ion Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120 6.
An important point after buying a device Siemens E12 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Siemens E12 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Siemens E12 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Siemens E12 you will learn all the available features of the product, as well as information on its operation. The information that you get Siemens E12 will certainly help you make a decision on the purchase.
If you already are a holder of Siemens E12, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Siemens E12.
However, one of the most important roles played by the user manual is to help in solving problems with Siemens E12. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Siemens E12 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center