Safetyp.5Important Safety Instructions READ AND SAVE THESE INSTRUCTIONSp.5Important Safety Instructionsp.5Safety Codes and Specificationsp.5Equipment and Usage Safety Requirementsp.5Power Requirements and Electrical Grounding Instructionsp.6Installationp.7Before You Beginp.7Tools and Parts Neededp.7Additional Parts Needed For Hard Wire Installationsp.7Parts Includedp.7Cabinet Requirementsp.7Figure 1: Cabinet Clearancesp.7Required Clearancesp.7Figure 2: Cooktop Clearancesp.8Electrical Requirementsp.9Figure 3: Electrical Outlet Placementp.9General Informationp.9Table 1: Electrical Specificationsp.10Installation Procedurep.10Installation Tipsp.10Install Ventilationp.10Prepare Walls and Floorp.10Prepare Rangep.10Install Strain Reliefp.10Figure 4: Electrical Connection and Strain Relief Knockout Panel Locationsp.11Connect Electricp.111. Four (4) wire range cordp.112. Three (3) wire range cordp.113. Four (4) wire flexible conduit connection (hard wire)p.114. Three (3) wire flexible conduit connection (hard wire)p.11Figure 5: Grounding Optionsp.12Four Wire Range Cord Connection (Recommended Method)p.121. Disconnect electrical power at breaker box.p.122. Remove the terminal block cover to expose the terminal blockp.12Figure 3: Four Wire Connectionp.124. Remove TOP nut, star washer, and round washer from each post.p.125. Remove screw from bottom end of ground strap.p.126. Remove ground strap from CENTER post, rotate so that wide end is at TOP and attach wide end to range through hole below junction box. Attach GREEN wire on TOP of ground strap. Tighten Screw.p.13Figure 7: Four Wire Range Cord Connection - Ground Strap and Wirep.138. Attach RED wire, round washer, star washer and nut IN THIS ORDER to LEFT post.p.139. Attach WHITE wire, round washer, star washer and nut IN THIS ORDER to CENTER post.p.1310. Attach BLACK wire, round washer, star washer and nut IN THIS ORDER to RIGHT post.p.13Figure 11: Four Wire Range Cord Connection (continued)p.1312. Tighten all connections securely and replace terminal block cover.p.1313. Properly secure strain relief. See “Install Strain Relief” on page 6.p.13Three Wire Range Cord Connectionp.131. Disconnect electrical power at breaker box.p.132. Remove the terminal block cover to expose the terminal block.p.14Figure 3: Terminal Blockp.144. Remove TOP nut, star washer, and round washer from each post.p.145. Attach WHITE wire, round washer, star washer and nut IN THIS ORDER on TOP of ground strap on CENTER post.p.146. Attach RED wire, round washer, star washer and nut IN THIS ORDER to LEFT post.p.147. Attach BLACK wire, round washer, star washer and nut IN THIS ORDER to RIGHT post.p.14Figure 8: Three Wire Connectionp.149. Tighten all connections securely and replace terminal block cover.p.14Figure 10: Completed Three Wire Range Cord Connectionp.1411. Properly secure strain relief. See “Install Strain Relief” on page 6.p.14Four Wire Flexible Conduit Connectionp.151. Disconnect electrical power at the breaker box.p.152. Remove the terminal block cover to expose the terminal block.p.153. Remove the TOP nut, star washer, and round washer from each post.p.154. Remove screw from bottom end of ground strap.p.155. Remove ground strap from CENTER post. Discard ground strap.p.156. Attach one terminal lug (included) through hole below terminal block using ground screw.p.157. Place one terminal lug (included) on each post. Replace the star washer and round washer and secure with 20 inch pounds of torque.p.158. Strip 3/8 inches (9.53 mm) of insulation from the end of each wire.p.15Figure 9: Wire Strippingp.1510. Insert the insulated grounding wire into the lug below the terminal block.p.1511. Insert stripped end of WHITE wire into the CENTER lug. Secure the clamping screw.p.15Figure 12: Attaching Wire to Terminal Lugp.1513. Insert stripped end of RED wire into the LEFT lug. Secure clamping screw.p.1514. Insert BLACK wire into the RIGHT lug. Secure clamping screw.p.1515. Tighten each clamping screw with the appropriate torque. See Table 2.p.15Table 2: Appropriate Torque Levels for Aluminum or Copper Wirep.1516. Properly secure flexible conduit at knockout on angle and at supply side junction box. The wiring is now complete.p.16Figure 17: Completed Four Wire Flexible Conduit Connectionp.16Three Wire Flexible Conduit Connectionp.161. Disconnect electrical power at the breaker box.p.162. Remove the terminal block cover to expose the terminal block.p.16Figure 3: Terminal Blockp.164. Remove the TOP nut, star washer, and round washer from each post.p.165. Place one terminal lug (packaged with this manual) on each post. Replace the star washer and round washer and secure with 20 inch pounds of torque.p.166. Strip 3/8 (9.53 mm) inches of insulation from the end of each wire.p.16Figure 7: Wire Strippingp.168. Insert stripped end of WHITE wire into the CENTER lug on TOP of the ground strap. Secure the clamping screw.p.17Figure 9: Attaching Wire to Terminal Lugp.1710. Insert stripped end of RED wire into the LEFT lug. Secure clamping screw.p.1711. Insert stripped end of BLACK wire into the RIGHT lug. Secure clamping screw.p.1712. Tighten each clamping screw with the appropriate torque. See Table 3.p.17Table 3: Appropriate Torque Levels for Aluminum or Copper Wirep.1713. Properly secure flexible conduit at knockout panel on range and at supply side junction box. The wiring is now complete.p.17Figure 14: Completed Three Wire Flexible Conduit Connectionp.17Anti-tip Bracketp.17Attach anti-tip bracket to floorp.171. Adjust height of range and level by rotating the adjustable leg supports on the bottom of the range, using 1-1/4 inch (31.75 mm) wrench. See Figure 2: Adjusting the Leg Support.p.18Figure 2: Adjusting the Leg Supportp.183. Measure to locate bracket position as shown in Figure 4: Anti-tip Bracket Location.p.18Figure 4: Anti-tip Bracket Locationp.185. Secure bracket with 2 screws (not included) that are adequate for mounting surface. (i.e.; for wood floor use wood screws for concrete floor use concrete anchors and screws).p.18Complete the Installationp.181. Move range close enough to the opening to plug into the receptacle.p.182. Slide range into position insuring that the left back leg slides under the anti-tip bracket. Range will sit 3/4” (19.05 mm) away from back wall when properly installed.p.183. Carefully tip range forward to insure that the anti-tip bracket engages the range back brace and prevents tip-over.p.184. Turn on electrical power. Check range for proper operation as described in Use and Care Manual.p.18Servicep.20Before Calling Servicep.20Product Data Platep.20Figure 5: Data Platep.20
Page 1 of the Siemens C) user manual — Estufas electrica de Siemens Instrucciones de instalación Modelo: HE2224(U,C), HE2425(U,C), HE2528U
Page 1 · click to enlarge
Page 1
Siemens C) diagram (page 1)
Fig. 1

Siemens Electric Range with threeD (Surround) Convection ®

Installation Instructions Models: HE2224(U,C), HE2425(U,C), HE2528U

Please read instructions before using. Important: Save these instructions.

Cuisinières électriques Siemens Instructions d’installation Modèle: HE2224(U,C), HE2425(U,C), HE2528U

Merci de lire les instructions avant d'utiliser. Important : Conserver ces instructions.

Estufas electrica de Siemens Instrucciones de instalación Modelo: HE2224(U,C), HE2425(U,C), HE2528U

Favor de leer las instrucciones antes de usar. Importante: Guarde estas instrucciones.

Page 2 of the Siemens C) user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Siemens C) user manual
Page 3 of the Siemens C) user manual — 866-44SIEMENS (447-4363)
Page 3 · click to enlarge
Page 3

Table of Contents

Safety 1

Important Safety Instructions 1

Before You Begin 3 Installation Procedure 6

Service 16

Before Calling Service 16

Questions?

866-44SIEMENS (447-4363)

www.siemens-home.com

5551 McFadden Ave. Huntington Beach, CA 92649 We look forward to hearing from you!

Page 4 of the Siemens C) user manual
Page 4 · click to enlarge
Page 4
Page 4 of the Siemens C) user manual
Page 5 of the Siemens C) user manual — READ AND SAVE THESE INSTRUCTIONS
Page 5 · click to enlarge
Page 5

Safety

Important Safety Instructions

READ AND SAVE THESE INSTRUCTIONS

Important Safety Instructions

  • Ask your dealer to recommend a qualified technician and an authorized repair service.
  • Install only per installation instructions provided in the literature package for this range.
  • Important - Save for local electrical inspector’s use.
  • Safety Codes and Specifications
  • This appliance complies with one or more of the following Standards:
  • UL 858, The Standard for the Safety of Household Electric Ranges
  • UL 923, The Standard for the Safety of Microwave Cooking Appliances
  • UL 507, The Standard for the Safety of Electric Fans
  • ANSI Z21.1-2000, The American National Standard for Household Cooking Gas Appliances
  • CAN/CSA-C22.2 No. 113-M1984 Fans and Ventilators
  • CAN/CSA-C22.2 No. 61-M89 Household Cooking Ranges
  • It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.
  • Be sure your appliance is properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/ NFPA No. 7 latest edition and local electrical code requirements.
  • Local codes vary. Installation, electrical connections and grounding must comply with all applicable codes.
  • This appliance has been tested in accordance with ANSI/UL 858 Standard for Safety for Household Ranges and CAN/CSA-22.2 No. 61 National Standard of Canada for Household Cooking Ranges. It is the responsibility of the owner and the installer to determine if additional requirements and standards apply in specific installations.

Equipment and Usage Safety Requirements

  • Unit is heavy and requires at least two persons or proper equipment to move.
  • Stepping, leaning or sitting on the doors or drawers of this range can result in serious injuries and also cause damage to the range.
  • Do not allow children to climb or play around the range. The weight of a child on an open door may cause the range to tip, resulting in serious burns or other injury.
  • Do not store items of interest to children in the cabinets above a range or on the backguard of a range. Children climbing on the range to reach items could be seriously injured.
  • To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is provided, the risk can be reduced by installing a range hood that projects a minimum of five inches (12.7 cm) beyond the bottom of the cabinets.
Page 6 of the Siemens C) user manual — Power Requirements and Electrical Grounding Instructions
Page 6 · click to enlarge
Page 6
  • Remove all tape and packaging before using the range. Destroy the packaging after unpacking the range. Never allow children to play with packaging material.
  • Do not repair or replace any part of the appliance unless specifically recommended in the manuals. All other servicing should be done by a qualified technician. This may reduce the risk of personal injury and damage to the range.
  • Never modify or alter the construction of a range by removing leveling legs, panels, wire covers, anti-tip brackets/screws, or any other part of the product.
  • DO NOT LIFT RANGE BY DOOR HANDLE.
  • Remove the door for easier handling and installation. See ‘Removing Oven Door’ in the Maintenance section of the Use and Care Manual.
  • Do not use the warming drawer (if equipped) or oven for storage.
  • Hidden surfaces may have sharp edges. Use caution when reaching behind or under range.

Power Requirements and Electrical Grounding Instructions

  • If required by the National Electrical Code (or Canadian Electrical Code), this appliance must be installed on a separate branch circuit.
  • Only a power-supply cord kit rated for this appliance and marked "for use with ranges" shall be used.
  • Before installing, turn power OFF at the service panel. Lock service panel to prevent power from being turned ON accidentally.
  • Before you plug in an electrical cord, be sure all controls are in the OFF position.
  • Know how to disconnect the power to the range at the circuit breaker or fuse box in case of an emergency.
  • Installer - show the owner the location of the circuit breaker or fuse. Mark it for easy reference.

Safety

Page 7 of the Siemens C) user manual — Before You Begin
Page 7 · click to enlarge
Page 7

Before You Begin

  • Tools and Parts Needed
  • 50 Amp Power Supply Cord Kit (not necessary for Canadian installations)
  • Measuring Tape
  • Phillips Head Screwdriver
  • 1-1/4” (31.8 mm) Wrench
  • Pencil
  • T-20 Torx Screwdriver
  • Screws (2) and Anchors (2) for Anti-Tip Bracket (style will vary depending on mounting surface)
  • Level
  • Drill and Drill Bit
  • Safety Gloves and Goggles
  • Tape (optional)
  • Cloth or Cardboard (optional - to protect floor)

Additional Parts Needed For Hard Wire Installations

  • Flexible Conduit (for Hard Wire Installation Only)
  • Torque Wrench (for Hard Wire Installation Only)
  • Note: Power Supply Cord Kit not necessary for Hard Wire Installations
  • Parts Included
  • Anti-Tip Bracket
  • Terminal Lugs (for use with Hard Wire Installations) (not necessary for Canadian installations)

Cabinet Requirements This unit is designed for installation near adjacent walls and projecting surfaces constructed of combustible materials. Allow a minimum of 30 inches (76.2 cm) between cabinets where range is to be installed (0.47” (12 mm) clearance from range sidewall to cabinet required in Canada).

30” (76.2 cm) Minimum between cabinets

Figure 1Cabinet Clearances

Required Clearances These clearance instructions were determined using Standard American cabinets. Standard base cabinets measure 36 inch (91.4 cm) high x 24 inch (60.9 cm) deep. Cabinets over the cooking surface and cabinets adjacent to those over the cook-

Page 8 of the Siemens C) user manual — Figure 2: Cooktop Clearances
Page 8 · click to enlarge
Page 8

ing surface measure 13 inches (33 cm) deep from backwall. If nonstandard cabi- nets are used, care should be taken to alter dimensions accordingly.

From cooktop to materials above:

There must be a minimum clearance of 30 inches (76.2 cm) between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet.

30in (76.2 cm) min. centered

30in (76.2 cm) min. 4in (10.2 cm) min

4in (10.2 cm) min

no clearance required (12 mm clearance from range sidewall to cabinet required in Canada.)

Figure 2Cooktop Clearances

24 inches (61 cm) is acceptable when the bottom of the wood or metal cabinet is protected by:

(a) not less than 1/4 inch (6.35 mm) of flame retardant material which must

(b) not less than No. 28 MSG sheet metal, 0.015 inch (.381 mm) stainless

steel’ or 0.024 inch (.601 mm) aluminum or copper.

From range walls to adjacent materials, see Figure 2: Cooktop Clearances:

No clearance is required from unit walls to adjacent vertical combustible walls on rear, right or left. Clearance from range top to adjacent vertical walls must be at least 4” (10.2 cm).

be covered with

Page 9 of the Siemens C) user manual — Electrical Requirements
Page 9 · click to enlarge
Page 9

Electrical Requirements The electrical outlet must be located in the shaded space in Figure 3: Electrical Outlet Placement.

7 1/2” (190.5 mm)

3 1/2” (88.9 mm)

4 1/2” (114.3 mm) 4 1/2” (114.3 mm)

21” (533.4 mm)

Figure 3Electrical Outlet Placement

Verify that wiring to house is adequate.

Contact your local utility company to verify that the present electric service to your home is adequate. In some instances, the size of the wiring to the house and ser- vice switch must be increased to handle the electrical load demanded by the range.

Verify that wiring inside house is adequate.

Most wiring codes require a separate circuit with separate disconnect switch and fuses either in the main entrance panel or in a separate switch and fuse box. Most local building regulations and codes require that electrical wiring be done by licensed electricians. Be sure to install your range according to the electric codes in place in your region.

General Information Ranges are dual rated for use on either 120/240 VAC or 120/208 VAC. See Table 1, “Electrical Specifications,” on page 6 for power ratings and circuit breaker sizes based upon the supply voltage for each model.

We recommend that the range be installed with a UL approved power cord set (not supplied). The electrical rating of the power cord set must be 120/240 volt, 50 amperes minimum. The power cord set shall be marked “For Use with Ranges.” Always use a new power cord. Alternatively, the range can also be hard wired using the terminal lugs included in the literature pack. If using this connection, flexible conduit must also be used (not supplied).

We recommend a 50 AMP, 60 Hz, 4 wire circuit; However, the NEC (National Electric Code) allows for some ranges to be installed on a 40 AMP circuit. Refer to your local electric code requirements in order to determine the required amper- age. Always choose a range power cord set that is rated for the circuit. In compli- ance with the NEC, a separate circuit is also recommended.

30” (762 mm)

Page 10 of the Siemens C) user manual — Install Strain Relief WARNING:
Page 10 · click to enlarge
Page 10

For installations other than those in Canada, install the strain relief and connect the range cord (or wire conductors) as described in the following steps.

Table 1Electrical Specifications

Check data plate for kW rating. Reference kW rating in table to determine amperage requirements.

kW RatingAMPS Required At 120/240 Volts:At 120/208 Volts:US Models:Canadian Models: 12.39.240 or 50* 12.69.540 or 50*50 13.510.250

* Varies by location. Refer to local electric code.

Installation Procedure

  • Installation Tips
  • Tape warming drawer or storage drawer shut to keep it from opening while installing the range.
  • During installation, place a portion of the box or a piece of cloth under the range to protect floors.
  • To make range lighter and easier to handle, remove door (see instructions in Use and Care manual).

Install Ventilation We strongly recommend the installation of a ventilation hood above this range. For most kitchens a certified hood rating of not less than 300 CFM is recom- mended. The range hood must be installed according to instructions furnished with the hood.

Prepare Walls and Floor Seal any holes in the walls or floor. Remove any obstructions (extra electrical or gas connections, etc.) so that range will rest against wall properly.

Prepare Range Place range in front of cabinets where it is to be installed. Remove any packaging.

Install Strain Relief WARNING:

The strain relief provided with your range cord must be properly installed.

Place strain relief in knockout below terminal block. See Figure 4: Electrical Con- nection and Strain Relief Knockout Panel Locations. Feed range cord through hole and strain relief up to terminal block. Allow for slack in the cord between the strain relief and terminal block. Once cord length/ slack has been adjusted, attach strain relief per instructions included with strain relief.

Page 11 of the Siemens C) user manual — WARNING:
Page 11 · click to enlarge
Page 11

Electrical connection (found behind terminal block cover)

Feed range cord through strain

relief in knockout panel here.

Figure 4Electrical Connection and Strain Relief Knockout Panel Locations

Connect Electric There are four possible electrical connections:

1. Four (4) wire range cord 2. Three (3) wire range cord 3. Four (4) wire flexible conduit connection (hard wire) 4. Three (3) wire flexible conduit connection (hard wire)

The four wire range cord connection is the recommended method, but where local codes permit, three wire connections are also acceptable.

As an alternative to the range cord, the appliance can also be hard wired with either a three or four wire connection. In this case, the terminal lugs supplied must be used.

Always verify that your chosen connection complies with all applicable codes. Table 1, “Electrical Specifications,” on page 6.

WARNING:

To prevent electrical shock, the grounding prong on the range cord should not be cut or removed under any circumstances. It must be plugged into a matching grounding type receptacle and connected to a correctly polarized 240- Volt circuit. If there is any doubt as to whether the wall receptacle is properly grounded, have it checked by a qualified electrician.

WARNING:

Risk of Electric Shock or Fire. Frame grounded to neutral through a ground strap. Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC), mobile homes, and recre- ational vehicles, or in an area where local codes prohibit grounding through the neutral conductor.

For installations where grounding through the neutral conductor is prohibited, (a) disconnect the link from the neutral, (b) use grounding terminal or lead to ground unit, (c) connect neutral terminal to lead branch circuit neutral in usual manner

Page 12 of the Siemens C) user manual — Figure 5: Grounding Options
Page 12 · click to enlarge
Page 12

(when the appliance is to be connected by means of a cord kit, use 4-conductor cord for this purpose)

Siemens C) — Figure 5: Grounding Options diagram (page 12)
Fig. 2 · Figure 5: Grounding Options
Figure 5Grounding Options

Use only cord kits rated 125/250 volts (minimum), 50 amperes and labeled “For Use with Ranges”. Strain relief provided with cord must be installed per instruc- tions included with cord.

Four Wire Range Cord Connection (Recommended Method)

1. Disconnect electrical power at breaker box. 2. Remove the terminal block cover to expose the terminal block
Siemens C) — Figure 5: Grounding Options diagram (page 12)
Fig. 3 · Figure 5: Grounding Options
Figure 3Four Wire Connection
4. Remove TOP nut, star washer, and round washer from each post.
5. Remove screw from bottom end of ground strap.
Page 13 of the Siemens C) user manual — 6. Remove ground strap from CENTER post, rotate so that wide end is at TOP and attach wide end to range through hole below junction box. Attach GREEN wire on TOP of ground strap. Tighten Screw.
Page 13 · click to enlarge
Page 13
6. Remove ground strap from CENTER post, rotate so that wide end is at TOP and attach wide end to range through hole below junction box. Attach GREEN wire on TOP of ground strap. Tighten Screw.
Siemens C) — 6. Remove ground strap from CENTER post, rotate so that wide end is at TOP and attach wide end to range through hole below junction box. Attach GREEN wire on TOP of ground strap. Tighten Screw. diagram (page 13)
Fig. 4 · 6. Remove ground strap from CENTER post, rotate so t…
Figure 7Four Wire Range Cord Connection - Ground Strap and Wire
8. Attach RED wire, round washer, star washer and nut IN THIS ORDER to LEFT post. 9. Attach WHITE wire, round washer, star washer and nut IN THIS ORDER to CENTER post. 10. Attach BLACK wire, round washer, star washer and nut IN THIS ORDER to RIGHT post.
Siemens C) — 6. Remove ground strap from CENTER post, rotate so that wide end is at TOP and attach wide end to range through hole below junction box. Attach GREEN wire on TOP of ground strap. Tighten Screw. diagram (page 13)
Fig. 5 · 6. Remove ground strap from CENTER post, rotate so t…
Figure 11Four Wire Range Cord Connection (continued)
12. Tighten all connections securely and replace terminal block cover. 13. Properly secure strain relief. See “Install Strain Relief” on page 6.

Three Wire Range Cord Connection The Four Wire Connection (above) is preferred, but where local codes and ordi- nances permit grounding through neutral and where conversion to four wire is impractical, the unit may be connected to the power supply via a three wire con- nection.

1. Disconnect electrical power at breaker box.
Page 14 of the Siemens C) user manual — 2. Remove the terminal block cover to expose the terminal block.
Page 14 · click to enlarge
Page 14
2. Remove the terminal block cover to expose the terminal block.
Siemens C) — 2. Remove the terminal block cover to expose the terminal block. diagram (page 14)
Fig. 6 · 2. Remove the terminal block cover to expose the ter…
Figure 3Terminal Block
4. Remove TOP nut, star washer, and round washer from each post.
5. Attach WHITE wire, round washer, star washer and nut IN THIS ORDER on TOP of ground strap on CENTER post. 6. Attach RED wire, round washer, star washer and nut IN THIS ORDER to LEFT post. 7. Attach BLACK wire, round washer, star washer and nut IN THIS ORDER to RIGHT post.
Siemens C) — 2. Remove the terminal block cover to expose the terminal block. diagram (page 14)
Fig. 7 · 2. Remove the terminal block cover to expose the ter…
9. Tighten all connections securely and replace terminal block cover.
Figure 10Completed Three Wire Range Cord Connection
11. Properly secure strain relief. See “Install Strain Relief” on page 6.
Page 15 of the Siemens C) user manual — Four Wire Flexible Conduit Connection
Page 15 · click to enlarge
Page 15

Four Wire Flexible Conduit Connec- tion

1. Disconnect electrical power at the breaker box. 2. Remove the terminal block cover to expose the terminal block. 3. Remove the TOP nut, star washer, and round washer from each post.
4. Remove screw from bottom end of ground strap. 5. Remove ground strap from CENTER post. Discard ground strap. 6. Attach one terminal lug (included) through hole below terminal block using ground screw. 7. Place one terminal lug (included) on each post. Replace the star washer and round washer and secure with 20 inch pounds of torque. 8. Strip 3/8 inches (9.53 mm) of insulation from the end of each wire.
Figure 9Wire Stripping
10. Insert the insulated grounding wire into the lug below the terminal block. 11. Insert stripped end of WHITE wire into the CENTER lug. Secure the clamping screw.
Figure 12Attaching Wire to Terminal Lug
13. Insert stripped end of RED wire into the LEFT lug. Secure clamping screw. 14. Insert BLACK wire into the RIGHT lug. Secure clamping screw. 15. Tighten each clamping screw with the appropriate torque. See Table 2.
Table 2Appropriate Torque Levels for Aluminum or Copper Wire

Gauge Torque (in./lbs.) Torque (Nm)

6 35 3.95

8 25 2.82

3/8 “ · lug · clamping screw wire

Page 16 of the Siemens C) user manual — 16. Properly secure flexible conduit at knockout on angle and at supply side junction box. The wiring is now complete.
Page 16 · click to enlarge
Page 16
16. Properly secure flexible conduit at knockout on angle and at supply side junction box. The wiring is now complete.
Siemens C) — 16. Properly secure flexible conduit at knockout on angle and at supply side junction box. The wiring is now complete. diagram (page 16)
Fig. 8 · 16. Properly secure flexible conduit at knockout on…
Figure 17Completed Four Wire Flexible Conduit Connection

Three Wire Flexible Conduit Con- nection

The Four Wire Connection is preferred, but where local codes and ordinances permit grounding through neutral and/or conversion to four wire is impractical, unit may be connected to the power supply via a three wire connection.

Siemens C) — 16. Properly secure flexible conduit at knockout on angle and at supply side junction box. The wiring is now complete. diagram (page 16)
Fig. 9 · 16. Properly secure flexible conduit at knockout on…
1. Disconnect electrical power at the breaker box. 2. Remove the terminal block cover to expose the terminal block.
Figure 3Terminal Block
4. Remove the TOP nut, star washer, and round washer from each post.
5. Place one terminal lug (packaged with this manual) on each post. Replace the star washer and round washer and secure with 20 inch pounds of torque. 6. Strip 3/8 (9.53 mm) inches of insulation from the end of each wire.
Siemens C) — 16. Properly secure flexible conduit at knockout on angle and at supply side junction box. The wiring is now complete. diagram (page 16)
Fig. 10 · 16. Properly secure flexible conduit at knockout on…
Figure 7Wire Stripping
Page 17 of the Siemens C) user manual — Attach anti-tip bracket to floor WARNING
Page 17 · click to enlarge
Page 17
8. Insert stripped end of WHITE wire into the CENTER lug on TOP of the ground strap. Secure the clamping screw.
Siemens C) — 8. Insert stripped end of WHITE wire into the CENTER lug on TOP of the ground strap. Secure the clamping screw. diagram (page 17)
Fig. 11 · 8. Insert stripped end of WHITE wire into the CENTER…
10. Insert stripped end of RED wire into the LEFT lug. Secure clamping screw. 11. Insert stripped end of BLACK wire into the RIGHT lug. Secure clamping screw. 12. Tighten each clamping screw with the appropriate torque. See Table 3.
Table 3Appropriate Torque Levels for Aluminum or Copper Wire
Siemens C) — 8. Insert stripped end of WHITE wire into the CENTER lug on TOP of the ground strap. Secure the clamping screw. diagram (page 17)
Fig. 12 · 8. Insert stripped end of WHITE wire into the CENTER…
13. Properly secure flexible conduit at knockout panel on range and at supply side junction box. The wiring is now complete.
Figure 14Completed Three Wire Flexible Conduit Connecti on

Anti-tip Bracket

Attach anti-tip bracket to floor WARNING

RANGE TIPPING HAZARD All ranges can tip and injury could result. To prevent accidental tipping of the range, attach it to the floor by installing the Anti-Tip Device sup- plied.

Page 18 of the Siemens C) user manual — 1. Adjust height of range and level by rotating the adjustable leg supports on the bottom of the range, using 1-1/4 inch (31.75 mm) wrench. See Figure 2: Adjusting the Leg Support.
Page 18 · click to enlarge
Page 18
  • A risk of tip-over may exist if the appliance is not installed in accordance with these instructions.
  • If the range is pulled away from the wall for cleaning, service, or any other reason, insure that the Anti-Tip Device is properly reengaged when the range is pushed back against the wall. In the event of abnormal usage (such as a person standing, sitting, or leaning on an open door), failure to take this precaution could result in tipping of the range. Personal injury might result from spilled hot liquids or from the range itself.
1. Adjust height of range and level by rotating the adjustable leg supports on the bottom of the range, using 1-1/4 inch (31.75 mm) wrench. See Figure 2: Adjusting the Leg Support.
Siemens C) — 1. Adjust height of range and level by rotating the adjustable leg supports on the bottom of the range, using 1-1/4 inch (31.75 mm) wrench. See Figure 2: Adjusting the Leg Support. diagram (page 18)
Fig. 13 · 1. Adjust height of range and level by rotating the…
Figure 2Adjusting the Leg Support
3. Measure to locate bracket position as shown in Figure 4: Anti-tip Bracket Location.

9/16" (14.29 mm) from rear wall to center of screw hole

flush against cabinet wall

Figure 4Anti-tip Bracket Location
5. Secure bracket with 2 screws (not included) that are adequate for mounting surface. (i.e.; for wood floor use wood screws for concrete floor use concrete anchors and screws).

Complete the Installation 1. Move range close enough to the opening to plug into the receptacle. 2. Slide range into position insuring that the left back leg slides under the anti-tip bracket. Range will sit 3/4” (19.05 mm) away from back wall when properly installed. 3. Carefully tip range forward to insure that the anti-tip bracket engages the range back brace and prevents tip-over. 4. Turn on electrical power. Check range for proper operation as described in Use and Care Manual.

Show 7 more labels / short text on this page
drawer · wrench · adjustable leg · rear wall · cabinet wall · floor · anti-tipping device
Page 19 of the Siemens C) user manual — 1. Adjust height of range and level by rotating the adjustable leg supports on the bottom of the range, using 1-1/4 inch (31.75 mm) wrench. See Figure 2: Adjusting the Leg Support.
Page 19 · click to enlarge
Page 19
Page 20 of the Siemens C) user manual — Data Plate
Page 20 · click to enlarge
Page 20

Service

Before Calling Service

See Use and Care Manual for troubleshooting information. Refer to the Warranty in the Use and Care Manual.

To reach a service representative, see the contact information at the front of the manual. Please be prepared with the information printed on your product data plate when calling.

Product Data Plate The data plate shows the model and serial number. Refer to the data plate on the appliance when requesting service. It is located on the frame near the drawer. Open the drawer to view it.

Data Plate

Figure 5Data Plate
Page 21 of the Siemens C) user manual — Service
Page 21 · click to enlarge
Page 21
Page 21 of the Siemens C) user manual — Service
Page 22 of the Siemens C) user manual — 866.44SIEMENS (447.4363)
Page 22 · click to enlarge
Page 22

Table des matières

Sécurité 1

Instructions de sécurité importantes 1

Avant de commencer 3 Procédure d'installation 6

Service 15

Avant d'effectuer un appel de service 15

Questions?

866.44SIEMENS (447.4363)

www.siemens-home.com

5551 McFadden Ave. Huntington Beach, CA 92649 Nous attendons de vos nouvelles !

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Siemens C)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Siemens C)

Be the first to ask — other owners or our team will answer.

Original document

Siemens C) manual PDF

56 pages·2.5 MB·Range·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…