Important Safety Instructions
Important Safety Instructions
Equipment and Usage Safety Requirements

Power Requirements and Electrical Grounding Instructions
Safety

Additional Parts Needed For Hard Wire Installations
Cabinet Requirements This unit is designed for installation near adjacent walls and projecting surfaces constructed of combustible materials. Allow a minimum of 30 inches (76.2 cm) between cabinets where range is to be installed (0.47” (12 mm) clearance from range sidewall to cabinet required in Canada).
30” (76.2 cm) Minimum between cabinets
Required Clearances These clearance instructions were determined using Standard American cabinets. Standard base cabinets measure 36 inch (91.4 cm) high x 24 inch (60.9 cm) deep. Cabinets over the cooking surface and cabinets adjacent to those over the cook-

ing surface measure 13 inches (33 cm) deep from backwall. If nonstandard cabi- nets are used, care should be taken to alter dimensions accordingly.
From cooktop to materials above:
There must be a minimum clearance of 30 inches (76.2 cm) between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet.
30in (76.2 cm) min. centered
30in (76.2 cm) min. 4in (10.2 cm) min
4in (10.2 cm) min
no clearance required (12 mm clearance from range sidewall to cabinet required in Canada.)
24 inches (61 cm) is acceptable when the bottom of the wood or metal cabinet is protected by:
(a) not less than 1/4 inch (6.35 mm) of flame retardant material which must
(b) not less than No. 28 MSG sheet metal, 0.015 inch (.381 mm) stainless
steel’ or 0.024 inch (.601 mm) aluminum or copper.
From range walls to adjacent materials, see Figure 2: Cooktop Clearances:
No clearance is required from unit walls to adjacent vertical combustible walls on rear, right or left. Clearance from range top to adjacent vertical walls must be at least 4” (10.2 cm).
be covered with

Electrical Requirements The electrical outlet must be located in the shaded space in Figure 3: Electrical Outlet Placement.
7 1/2” (190.5 mm)
3 1/2” (88.9 mm)
4 1/2” (114.3 mm) 4 1/2” (114.3 mm)
21” (533.4 mm)
Verify that wiring to house is adequate.
Contact your local utility company to verify that the present electric service to your home is adequate. In some instances, the size of the wiring to the house and ser- vice switch must be increased to handle the electrical load demanded by the range.
Verify that wiring inside house is adequate.
Most wiring codes require a separate circuit with separate disconnect switch and fuses either in the main entrance panel or in a separate switch and fuse box. Most local building regulations and codes require that electrical wiring be done by licensed electricians. Be sure to install your range according to the electric codes in place in your region.
General Information Ranges are dual rated for use on either 120/240 VAC or 120/208 VAC. See Table 1, “Electrical Specifications,” on page 6 for power ratings and circuit breaker sizes based upon the supply voltage for each model.
We recommend that the range be installed with a UL approved power cord set (not supplied). The electrical rating of the power cord set must be 120/240 volt, 50 amperes minimum. The power cord set shall be marked “For Use with Ranges.” Always use a new power cord. Alternatively, the range can also be hard wired using the terminal lugs included in the literature pack. If using this connection, flexible conduit must also be used (not supplied).
We recommend a 50 AMP, 60 Hz, 4 wire circuit; However, the NEC (National Electric Code) allows for some ranges to be installed on a 40 AMP circuit. Refer to your local electric code requirements in order to determine the required amper- age. Always choose a range power cord set that is rated for the circuit. In compli- ance with the NEC, a separate circuit is also recommended.
30” (762 mm)

For installations other than those in Canada, install the strain relief and connect the range cord (or wire conductors) as described in the following steps.
Check data plate for kW rating. Reference kW rating in table to determine amperage requirements.
* Varies by location. Refer to local electric code.
Install Ventilation We strongly recommend the installation of a ventilation hood above this range. For most kitchens a certified hood rating of not less than 300 CFM is recom- mended. The range hood must be installed according to instructions furnished with the hood.
Prepare Walls and Floor Seal any holes in the walls or floor. Remove any obstructions (extra electrical or gas connections, etc.) so that range will rest against wall properly.
Prepare Range Place range in front of cabinets where it is to be installed. Remove any packaging.
The strain relief provided with your range cord must be properly installed.
Place strain relief in knockout below terminal block. See Figure 4: Electrical Con- nection and Strain Relief Knockout Panel Locations. Feed range cord through hole and strain relief up to terminal block. Allow for slack in the cord between the strain relief and terminal block. Once cord length/ slack has been adjusted, attach strain relief per instructions included with strain relief.

Electrical connection (found behind terminal block cover)
Feed range cord through strain
relief in knockout panel here.
The four wire range cord connection is the recommended method, but where local codes permit, three wire connections are also acceptable.
As an alternative to the range cord, the appliance can also be hard wired with either a three or four wire connection. In this case, the terminal lugs supplied must be used.
Always verify that your chosen connection complies with all applicable codes. Table 1, “Electrical Specifications,” on page 6.
To prevent electrical shock, the grounding prong on the range cord should not be cut or removed under any circumstances. It must be plugged into a matching grounding type receptacle and connected to a correctly polarized 240- Volt circuit. If there is any doubt as to whether the wall receptacle is properly grounded, have it checked by a qualified electrician.
Risk of Electric Shock or Fire. Frame grounded to neutral through a ground strap. Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC), mobile homes, and recre- ational vehicles, or in an area where local codes prohibit grounding through the neutral conductor.
For installations where grounding through the neutral conductor is prohibited, (a) disconnect the link from the neutral, (b) use grounding terminal or lead to ground unit, (c) connect neutral terminal to lead branch circuit neutral in usual manner

(when the appliance is to be connected by means of a cord kit, use 4-conductor cord for this purpose)

Use only cord kits rated 125/250 volts (minimum), 50 amperes and labeled “For Use with Ranges”. Strain relief provided with cord must be installed per instruc- tions included with cord.
Four Wire Range Cord Connection (Recommended Method)




Three Wire Range Cord Connection The Four Wire Connection (above) is preferred, but where local codes and ordi- nances permit grounding through neutral and where conversion to four wire is impractical, the unit may be connected to the power supply via a three wire con- nection.




Four Wire Flexible Conduit Connec- tion
Gauge Torque (in./lbs.) Torque (Nm)
6 35 3.95
8 25 2.82
3/8 “ · lug · clamping screw wire


Three Wire Flexible Conduit Con- nection
The Four Wire Connection is preferred, but where local codes and ordinances permit grounding through neutral and/or conversion to four wire is impractical, unit may be connected to the power supply via a three wire connection.





RANGE TIPPING HAZARD All ranges can tip and injury could result. To prevent accidental tipping of the range, attach it to the floor by installing the Anti-Tip Device sup- plied.


9/16" (14.29 mm) from rear wall to center of screw hole
flush against cabinet wall
Complete the Installation 1. Move range close enough to the opening to plug into the receptacle. 2. Slide range into position insuring that the left back leg slides under the anti-tip bracket. Range will sit 3/4” (19.05 mm) away from back wall when properly installed. 3. Carefully tip range forward to insure that the anti-tip bracket engages the range back brace and prevents tip-over. 4. Turn on electrical power. Check range for proper operation as described in Use and Care Manual.


Before Calling Service
See Use and Care Manual for troubleshooting information. Refer to the Warranty in the Use and Care Manual.
To reach a service representative, see the contact information at the front of the manual. Please be prepared with the information printed on your product data plate when calling.
Product Data Plate The data plate shows the model and serial number. Refer to the data plate on the appliance when requesting service. It is located on the frame near the drawer. Open the drawer to view it.



Instructions de sécurité importantes 1
Avant de commencer 3 Procédure d'installation 6
Avant d'effectuer un appel de service 15
5551 McFadden Ave. Huntington Beach, CA 92649 Nous attendons de vos nouvelles !
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.