Administrator Manual

The IP telephone optiPoint 410/420 complies with the European standard EN 60 950 which deals with the safety of information technology appliances including electronic office equipment. This device has been designed with safety in mind, thus protecting both indi- viduals and objects.
Safety Precautions

The device conforms to the EU guideline 1999/5/EG, as attested by the CE mark.
This device has been manufactured in accordance with our certified environ- mental management system (ISO 14001). This process ensures that energy consumption and the use of primary raw materials are kept to a minimum, thus reducing waste production.
All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and elec- tronic equipment. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service, the shop where you pur- chased the product or your sales representative. The statements quoted above are only fully valid for equipment which is in- stalled and sold in the countries of the European Union and is covered by the directive 2002/96/EC. Countries outside the European Union may have other regulations regarding the disposal of electrical and electronic equipment.
Safety Precautions




About the Manual General Information
The instructions within this manual will help you in administering and main- taining the optiPoint 410/420. The instructions contain important informa- tion for safe and proper operation of the optiPoint 410/420. Follow them carefully to avoid improper operation and get the most out of your multi- function telephone in a network environment.
These instructions describe administration through the operation of optiPoint 410/420. In addition, you can administer optiPoint 410/420 with the help of a web interface Æ page 42 or through a deployment tool (see instruction on administration with deployment tool). There is a separate manual for the operators. A quick reference guide con- tains a fast and reliable explanation corresponding to frequently used func- tions.
The identification details of your telephone are given on the nameplate containing the exact product designation and serial number on the bottom of the base unit. For more information on the software version, please refer to "General In- formation" in the Web-Based Management Tool section (Æ page 45). Please have these ready whenever you call our service department be- cause of trouble with or defects on the unit itself.
In some cases, while using the telephone you may hear an echo, which can be quite strong. This is not due to any design defect or other fault with your IP telephone, but caused by the other client. For example, if the echo occurs during a teleconference, it may be that the loudspeakers and microphones need to be repositioned.

General Information Safety Precautions for IP Telephony
Different methods can be implemented to protect an IP environment from external attacks (denial of service attacks, viruses, etc.) and call monitor- ing.
To ensure the secure transmission of call audio data, the Æ SRTP/SRTCP protocol is used in conjunction with the Æ CORNET IP TS and encrypted via a Æ PSS key that is valid for the whole network.
Security settings are updated and activated via the deployment tool (see the Deployment Tool administration manual).
You can view the next scheduled security key update in the Web-Based Management Tool (Æ page 57).
VoIP Security is available on the optiPoint 410/420 economy plus, standard, and advance telephones.

Safety
Information that is important for preventing injury or damages is marked specially, as they are important instructions for correct use of the unit.
7 This symbol indicates a hazard. Failure to follow the instructions giv- en may result in injury or in damage to the unit.
Key information important for the proper use of the unit is marked with this symbol.
The following symbols are used to indicate the different operation-related sequence descriptions:
Operation of the optiPoint 410 entry.
Operation of the optiPoint 410/420 economy/economy plus/standard/ad- vance and.
Operation through the web-based management tool.

General Information Notes and Symbols
Operating the telephone
n Lift the handset (off-hook).
t Replace the handset (on-hook).
s Conduct a call.
o Enter a telephone number or code. u or v Increase or reduce the value depending on the current operating mode.
optiPoint 410/420 economy/economy plus/stan- dard/advance
: The option appears on the screen. Press the : key to confirm your selection. > : Look for the select option. Press the < > keys, until the option appears on the screen. Then press the : key to confirm your selection.
Changing and viewing the configuration data in the optiPoint 410 entry is done by entering different refer- ence numbers.
For description of viewing data values on the LEDs of the optiPoint 410 entry see Æ page 100Administrator Manual.
Continue? > · 01=Configuration? > · optiPoint 410 entry

This chapter gives you an overview of the optiPoint 410/420 telephone models and their properties.
[1] Valid in software version 5.x or higher on HiPath 3000/5000 (version 6.0 or higher) and Hi- Path 4000 (version 3.0 or higher).

Setting Up the Telephone Installing the Telephone
This chapter describes how to connect the individual elements of the optiPoint 410/420 with each other (Æ Installing the Telephone) and how to set up the device ready for operation (Æ Preparing for Operation).
Connectors on the bottom of the telephone


3 6 4 5
2 1 3 1 2
optiPoint 410 entry optiPoint 410/420 standard
[1] Power over LAN: If power is supplied over the LAN cable, no local power supply is required.

Installing the Telephone Setting Up the Telephone
7 Only use switches in the LAN, to which the optiPoint 410/420 is connected. An operation at hubs can cause serious malfunctions in the hub and in the whole network.
The Western plugs of all cable connections must audibly snap into place.
Only if power not supported by LAN:
7 Use only the plug-in power supply unit fitting the optiPoint 410/420: – GER/IM: AUL:06D1284 – GBR: AUL:06D1287 – USA: AUL:51A4827
– Plug the plug-in power supply unit into the mains. – Plug the connector 3 at the bottom of the telephone into the plug-in
power supply unit.

Setting Up the Telephone Preparing for Operation
Preparing for Operation
For the optiPoint 410/420 economy/economy plus/stan- dard/advance follow the sequence described below. The sequence for the optiPoint 410 entry is described from Æ page 16.
The start up process sequence describes a stan- dard case of configuration. Network configura- tions that deviate from the standard case may re- quire additional entries.
Entering the administration area
: Confirm to enter the Configuration Menu.
o Enter admin password (default: 123456).
: Confirm.
01=Configuration? >

Preparing for Operation Setting Up the Telephone
Only if no DHCP server:
: Confirm. > : Confirm to switch the DHCP IP assign off. The change is displayed. > : Choose and confirm.
01=DHCP IP assign? >
02=Terminal IP addr.? >
: Confirm.
o Enter IP address of the optiPoint 410/420 (to edit see Æ page 93).
: Confirm. The IP address is displayed. > : Choose and confirm.
: Confirm.
o Enter terminal mask of the optiPoint 410/420 (to edit see Æ page 94).
: Confirm. The terminal mask is displayed. > : Choose and confirm to go to the top level of the config- uration menu.
In all configuration types
Enter Gateway address for communication with the HiPath System via the gateway. Entering only possible via Web-based Management, see Æ page 42.
Menu System > Gateway settings, see Æ page 55.
Enter Registration subscriber number (extension number). The extension number must be stored in the HiPath system. Entering only possible via Web-based Management, see Æ page 42.
Menu System > Gateway settings, see Æ page 55.
If the optiPoint 410 economy/economy plus/standard/ advance and optiPoint 420 advance does not function after making the described configuration, the failure can be attributed to peculiarities of the network environ- ment. More information on error detection is available in the "Start up not successful" Æ page 91.

Setting Up the Telephone Preparing for Operation
optiPoint 410 entry
Entering the administration area
e d g Press the keys simultaneously
o Enter admin password (default: 123456).
r Terminate the operation.
You are now in the Administration Area (all LEDs flash).
The top two function keys take over the following func- tions in this area:
1st Function key
Press 1st function key to make settings.
2nd Function key
Press 2nd function key to view settings.

Preparing for Operation Setting Up the Telephone

ddd Enter code to switch the DHCP IP assign off.
o Enter IP address of the optiPoint 410 entry (to edit see Æ page 93).
o Enter terminal mask of the optiPoint 410 entry (to edit see Æ page 93).
o Enter the default Route of the optiPoint 410 entry (to edit see Æ page 93).
Only if you are working in a Virtual LAN (VLAN)
fid Input the code to define the manual configuration of the VLAN Discovery Mode. r Terminate the operation.
o Enter (0 - 4095) for the Virtual LAN ID Æ page 62 (to edit see Æ page 93).

Setting Up the Telephone Preparing for Operation
All other settings of your optiPoint 410 entry must be made through the "Web-based Management Tool" Æ page 42.
Confirm your entries and start the telephone:
Press key.
mm Enter the code.
r Confirm the entry.
After the start, the telephone is silent and you can make the other settings Æ page 32.
If the optiPoint 410 entry does not function after making the described configuration, the failure can be attribut- ed to peculiarities of the network environment. More information on error detection is available in the "Start up not successful" Æ page 91.
Other settings

The following pages describe how to make administration settings for the optiPoint 410/420 in a HiPath 3000/5000 / HiPath 4000 system.
There are different ways to make settings: • Locally on the telephone: – optiPoint 410/420 economy/economy plus/standard/advance
Æ page 20 – optiPoint 410 entry Æ page 32
Deployment Tool").
A few functions of the optiPoint 410/420 display module or application module are administered directly on the display module or application module Æ page 38 or Æ page 40.
The execution of the configuration and diagnostics jobs described below require good knowledge of network technology as well as of network pro- tocols, and they are normally carried out by network administrators. For your support you will find some background information in the chapter "Alphabetical Reference", Æ page 58.
The administration of an optiPoint 410/420 (locally or through re- mote maintenance) is possible only if no conversation is being con- ducted over this telephone.
The configuration and diagnostics jobs via the telephone are execut- able with restrictions only.
Only the Web-based Management allows unrestricted access to all configuration menuesÆ page 42.
Administration

Administration optiPoint 410/420 economy/economy plus/standard/advance
optiPoint 410/420 economy/ economy plus/standard/advance
Access to the Administration Menu
If you are in the Administration Menu, then the optiPoint 410/420 cannot be accessed ("offline").
All configuration and diagnostic operations are protect- ed against illegal accesses by the Administrator pass- word. e d g Press keys simultaneously.
: Confirm to enter the Configuration Menu.
o Enter admin password (default: 123456).
: Confirm.
The first entry of the selected menu is displayed. or > : Choose and confirm to enter the Diagnostics Menu. > : Choose and confirm to start the phone.
01=Configuration? > · 02=Diagnostics? > · 03=Start Phone? >

optiPoint 410/420 economy/economy plus/standard/advance Administration
Configurations
For detailed information see Æ page 62.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20.
: Confirm.
01=DHCP IP assign? >
: Confirm. or > : Confirm.
The change is displayed.
For detailed information see Æ page 80.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
02=Terminal IP addr.? >
o Enter IP address (to edit see Æ page 93).
: Confirm. The change is displayed.
For detailed information see Æ page 80.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
o Enter Terminal Maske (to edit see Æ page 94).
: Confirm. The change is displayed.

Administration optiPoint 410/420 economy/economy plus/standard/advance
For detailed information see Æ page 62.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
o Enter IP address (to edit see Æ page 93).
: Confirm. The change is displayed.
For detailed information see Æ page 81.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
: Confirm. or > : Choose and confirm.
Confirm. The change is displayed.
For detailed information see Æ page 62.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
o Enter value (to edit see Æ page 93).
: Confirm. The change is displayed.

optiPoint 410/420 economy/economy plus/standard/advance Administration
For detailed information see Æ page 75.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
: Confirm. or > : Choose and confirm. or > : Choose and confirm. or > : Choose and confirm.
The change is displayed.
LAN Port 1 Mode
For detailed information see Æ page 69.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
08=LAN port 1 mode? >
: Confirm. or > : Choose and confirm. or > : Choose and confirm. or > : Choose and confirm. or > : Choose and confirm.
10 Mb/s half duplex >
10 Mb/s full duplex >
100 Mb/s half duplex >
100 Mb/s full duplex >
The change is displayed.

Administration optiPoint 410/420 economy/economy plus/standard/advance
LAN Port 2 Mode
For detailed information see Æ page 69.
„LAN Port 2 Mode“ is not configurable for optiPoint 410 entry und optiPoint 410/ 420 economy.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
09=LAN port 2 mode? >
: Confirm. or > : Choose and confirm. or > : Choose and confirm. or > : Choose and confirm. or > : Choose and confirm.
10 Mb/s half duplex >
10 Mb/s full duplex >
100 Mb/s half duplex >
100 Mb/s full duplex >
The change is displayed.
For detailed information see Æ page 79.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
10=Fully qual sub num? >
o Enter Subscriber Number (to edit see Æ page 93).
: Confirm. The change is displayed.
For detailed information see Æ page 79.
Enter "Administration Menu" and go to the Configura- tion Menu Æ page 20. > : Choose and confirm.
o Enter Subscriber Password (to edit see Æ page 93).
: Confirm. The change is displayed.
![Page 25 of the Siemens 2000 user manual — 0123456789!"#$%&’()*+,-. /:;<=>?[¥]^_{|}ËÁ <>](/cdn/reader/0a/0a9275e3dec1f9444d61246bfc5cbf03eaa9ca4654ced787e68086151d7d23fa/images/page-25.webp?w=400)
optiPoint 410/420 economy/economy plus/standard/advance Administration
Diagnostics
For detailed information see Æ page 62.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20.
: Confirm.
> Press key to show the next display.
> Press key to show the next display.
> Press key to show the next display.
> Press key to show the next display.
: Confirm to end the test.
For detailed information see Æ page 72.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm. All LEDs are flashing.

Administration optiPoint 410/420 economy/economy plus/standard/advance
For detailed information see Æ page 68.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm.
Please press key >
e.g. >, u or h Press any key (except :) and read the display.
: Confirm to end the test.
For detailed information see Æ page 59.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm.
04=Audio loop test? >
Execute test:
: Confirm to end the test.
For detailed information see Æ page 75.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm. Wait until the result is displayed.
: Confirm to end the test.
For detailed information see Æ page 76.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm. Wait until the result is displayed.
: Confirm to end the test.

optiPoint 410/420 economy/economy plus/standard/advance Administration
For detailed information see Æ page 74.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm.
: Confirm. or: Choose and confirm. or: Choose and confirm. or: Choose and confirm. or: Choose and confirm. or: Choose and confirm. or: Choose and confirm. or: Choose and confirm. or: Choose and confirm. or: Choose and confirm.
01=User specified IP? >
03=DL server address? >
04=Default Router IP? >
05=Route 1 Gateway IP?>
06=Route 2 Gateway IP?>
07=SNMP trap address? >
08=Terminal IP addr.? >
08=Terminal IP addr.? >
Execute test:
: Confirm to start pinging. The result appears on the display after a few seconds.
or PING change target: > : Choose and confirm.
o Enter IP address (to edit see Æ page 93).
: Confirm. The change is displayed.
On changing the IP addresses of the entries "02=..." to "09=..." the IP addresses actually en- tered in the optiPoint 410/420 are changed. This can lead to the limiting of functions.

Administration optiPoint 410/420 economy/economy plus/standard/advance
For detailed information see Æ page 72.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm.
: Confirm. or > : Choose and confirm.
The change is displayed.
For detailed information see Æ page 77.
„SLK Test“ is executable only for optiPoint 420 telephones.
Enter "Administration Menu" and go to the Diagnostics Menu Æ page 20. > : Choose and confirm.
Displaytest is running.
: Choose and confirm.
Press tick to stop it >
Displaytest finished.

optiPoint 410/420 economy/economy plus/standard/advance Administration
Restart
Reset via the Web-based Management Tool Æ page 42. 1. Open the Dialog „Restart Terminal“. Menu: Administrator Actions > Restart Terminal 2. Click on the button „Restart“.
By pulling the power plug
Disconnect the red Western plug of the power supply unit cable (Pos. 3 Æ page 12) or, if "Power over LAN", disconnect the LAN cable (Pos. 1 Æ page 12) from the optiPoint 410/420 for a few seconds. Then reconnect the plug.
On normal restart the following displays come in se- quence:
NETBOOT - 1.10 optiPoint 410
Basic display after finished restart.
Web-based Management Tool · After restart

Administration optiPoint 410/420 economy/economy plus/standard/advance
Error Messages
The DHCP server cannot assign any terminal IP address Æ page 80.
Possible solution:
Check the DHCP server.
The telephone is unable to find a network.
Possible solution:
Check the network cable.
No valid registration password
The PBX No. Æ page 65, Participant No. Æ page 79, and/or the participant password Æ page 79 are invalid.
Possible solution:
Change the Gateway address Æ page 65. Change the Participant No. Æ page 79. Change the participant password Æ page 79.
Error during file upload/download: An error occurred during data transfer. An appropriate error message can be viewed in the display.
Not all necessary FTP parameters are set.
FTP parameter missing EXIT?
Possible solution:
Enter the FTP account name Æ page 64. Enter the FTP password Æ page 64. Enter the FTP username Æ page 65.
The Æ PSS key is no longer valid.

optiPoint 410/420 economy/economy plus/standard/advance Administration
The connection or login to the database failed.
No IP connection to the gateway.
The telephone is not correctly furnished to the PABX.
No client licenses exist in the gateway.
(Empty display) No connection to the power supply Æ page 12.

Administration optiPoint 410 entry
optiPoint 410 entry
After integrating the optiPoint 410 entry into your net- work successfully Æ page 16, you can make all other settings through the "Web-based Management Tool" Æ page 42.
If you are in the administration area, you cannot reach the optiPoint 410 entry ("offline").
All configuration and diagnostic operations are protect- ed against illegal accesses by the Administrator pass- word.
edg Press keys simultaneously to enter "administration area".
o Enter admin password (default: 123456).
r Terminate the operation.
You are now in the administration area (all LEDs flash).
You can make the system display the important settings of your optiPoint 410 entry.
Making changes in the administration area (see above).
Press the 2nd function key from the top.
o Enter the 2-digit code (Table Æ page 103) for the de- sired function.
r Confirm the entry.
The settings are displayed through different illumina- tions of the LEDs. The table on Æ page 100 describes the meaning of the LEDs.
View settings

optiPoint 410 entry Administration
Restart
Reset via the Web-based Management Tool Æ page 42. 1. Open the Dialog „Restart Terminal“. Menu: Administrator Actions > Restart Terminal 2. Click on the button „Restart“.
Enter the administration area Æ page 32.
Making changes in the administration area Æ page 32.
ehk Press keys simultaneously.
o Enter the Administrator password (default: 123456).
r Confirm the entry.
During start-up the LEDs momentarily illuminate in suc- cession.
Web-based Management Tool · Function Codes

Administration optiPoint 410 entry
Reset factory settings
The resetting can lead to the failure of all the functions of the optiPoint 410 entry. Ensure that you have all the necessary information for start up Æ page 16.
For standard values, see Æ page 96.
Disconnect the red Western plug of the power supply unit cable (Pos. 3 Æ page 12) or, if "Power over LAN", disconnect the LAN cable (Pos. 1 Æ page 12) from the optiPoint 410 entry for a few seconds.
Reset factory settings via the Web-based Management Tool Æ page 42. 1. Open the Dialog „Factory Reset“. Menu: Administrator Actions > Factory Reset 2. Click on the button „Restart“.
n Lift handset.
flm Press keys simultaneously.
o Enter the reset password (124816).
r Confirm the entry.
t Replace the handset.
Web-based Management Tool · Function Codes

optiPoint 410 entry Administration

The LEDs flash till you switch to the Administration Mode Æ page 32.
The DHCP server cannot assign a terminal IP address Æ page 80.
The DHCP server cannot assign a terminal screen Æ page 80.
The DHCP server cannot assign a default route Æ page 62.
The DHCP IP assignment Æ page 62 is switched off and no terminal IP address is configured.

Administration optiPoint 410 entry

The DHCP IP assignment Æ page 62 is switched off and no terminal screen is configured.
The DHCP IP assignment Æ page 62 66 is switched off and no default route is configured.
The number Æ page 79 and/or password Æ page 79 are not configured.

optiPoint 410 entry Administration

The telephone cannot find the PBX Æ page 86.
The PBX No. Æ page 65, Participant No. Æ page 79, and/or the participant password Æ page 79 are invalid.

Administration optiPoint display module
optiPoint display module
Firmware Update
Firmware cannot be updated if a Java MIDlet is active (for example, a speed dialing list).
To update your optiPoint display module, perform the following steps: 1. Make sure that an FTP server is available, see Æ page 89, and that the relevant firmware file is stored on the server. 2. Start the Web-Based Management Tool, see Æ page 42. 3. Select "Administration" > [password] > "File Trans- fer", see Æ page 50. 4. Enter the following parameters: – FTP server address, see Æ page 64 – FTP account name, see Æ page 64 – FTP username, see Æ page 65 – DSM filename, see Æ page 63 5. Select "DSM Filename" from the field "Action on submit", see Æ page 58. 6. Select "Submit".

optiPoint display module Administration
Configuring the LDAP Server
Perform the following steps to enter the LDAP server IP address and port number: 1. Start the Web-Based Management Tool, see Æ page 43. 2. Select "Administration" > [password] > "Applica- tions" > "LDAP", see Æ page 47. 3. Enter the IP address of the LDAP server, see Æ page 69. 4. Select "Submit". 5. Select "System" > "Port Settings", see Æ page 56. 6. Enter the port number for communication with the LDAP server, see Æ page 69. 7. Select "Submit".
Installing the LDAP Template
A standard template is already installed. You can also install a template that corresponds to your personal criteria. See Æ page 70 for an example of this template.
Perform the following steps to transfer a template to your optiPoint display module: 1. Make sure that an FTP server is available (see Æ page 89) and that the relevant template file is stored on the server. 2. Start the Web-Based Management Tool, see Æ page 43. 3. Select "Administration" > [password] > "File Trans- fer", see Æ page 50. 4. Enter the following parameters: – FTP server address, see Æ page 64 – FTP account name, see Æ page 64 – FTP username, see Æ page 65 – LDAP template filename, see Æ page 72 5. Select "Download LDAP template" from the "Action on submit" field, see Æ page 58. 6. Select "Submit".

Administration optiPoint application module
optiPoint application module
Firmware Update
Firmware cannot be updated if a Java MIDlet is active (for example, a speed dialing list).
Perform the following steps to update the software on your optiPoint application module: 1. Make sure that an FTP server is available, see Æ page 89, and that the relevant firmware file is stored on the server. 2. Start the Web-Based Management Tool, see Æ page 42. 3. Select "Administration" > [password] > "File Trans- fer", see Æ page 50. 4. Enter the following parameters: – FTP server address, see Æ page 64 – FTP account name, see Æ page 64 – FTP username, see Æ page 65 – DSM filename, see Æ page 63 5. Select "DSM Filename" from the "Action on submit" list, see Æ page 58. 6. Select "Submit".

optiPoint application module Administration
Configuring the LDAP Server
Perform the following steps to enter the LDAP server IP address and port number: 1. Start the Web-Based Management Tool, see Æ page 43. 2. Select "Administration" > [password] > "Applica- tions" > "LDAP", see Æ page 47. 3. Enter the IP address of the LDAP server, see Æ page 69. 4. Select "Submit". 5. Select "System" > "Port Settings", see Æ page 56. 6. Enter the port number for communication with the LDAP server, see Æ page 69. 7. Select "Submit".
Installing an LDAP Template
A standard template is already installed. You can also install a template that corresponds to your personal criteria. See Æ page 70 for an example of this.
Perform the following steps to transfer a template to your optiPoint application module: 1. Maker sure that an FTP server is available (see Æ page 89) and that the relevant template file is stored on the server. 2. Start the Web-Based Management Tool, see Æ page 43. 3. Select "Administration" > [password] > "File Trans- fer", see Æ page 50. 4. Enter the following parameters: – FTP server address, see Æ page 64 – FTP account name, see Æ page 64 – FTP username, see Æ page 65 – LDAP template filename, see Æ page 72 5. Select "Download LDAP template" from the "Action on submit" list, see Æ page 58. 6. Select "Submit".

Administration Web-based Management Tool
Web-based Management Tool
General
The optiPoint 410/420 is equipped with an HTTP web server that permits the mapping of the telephone's con- tent on the web browser of a PC integrated in the LAN ("Web-based Management Tool").
For this, the IP data of the optiPoint 410/420 Æ page 103 and the PC must be arranged correct- ly.
The web-based management tool contains the follow- ing formula elements:
Administration To go to the corresponding page, click on the link.
To take over the changes in the current form, click on the button. This operation transfers the changes to the optiPoint 410/420.
Click on the button to reset the changes in the current form to the earlier values in the optiPoint 410/420.
Click on the button to execute an action (such as "Save", "Download", "Invoke" and "Restart"). A message is dis- played if there is an error.
Select an option in the List field.
To activate/deactivate a function, click on the checkbox.

Web-based Management Tool Administration
Open web-based management tool
To invoke the interface, open a web browser and enter the following URL:
For optiPoint 410/420 economy plus/standard/advance: https://[IP of the telephone]
where [IP of the telephone] represents the IP address of the optiPoint 410/ 420 that you wish to match.
The start page of the web server is displayed (example optiPoint 420 advance).

only available for optiPoint 410/420 standard/advance
Click on "Administration".

Enter the administrator password for this optiPoint 410/420 telephone and click on "Login".

Administration Web-based Management Tool
– Clear User Data Æ page 46 [1]
– Restart Terminal Æ page 46 – Restore Factory Settings Æ page 46 • Applications [1]
– Dialling Properties Æ page 47 [1]
– Java Æ page 47 [1]
– LDAP Æ page 47 [1]
– WAP Æ page 48 [1]
– WAP Favourites Æ page 48 [1]
– Miscellaneous Æ page 48 [1]
1 Only for optiPoint 410/420 standard/advance available 2 Only for optiPoint 410/420 economy plus/standard/advance with software version 5.x and higher on HiPath 3000/5000 (version 6.0 and higher) or HiPath 4000 (version 3.0 and high- er).

Web-based Management Tool Administration
Click on the required field to see a description for each parameter.


General Information · Change administrator password

Administration Web-based Management Tool
Click on the required field to see a description for each parameter.
(Only for optiPoint 410/420 standard/advance available)

(Only for optiPoint 410/420 standard/advance available)




Web-based Management Tool Administration
(Only for optiPoint 410/420 standard/advance available)
Click on the required field to see a description for each parameter.
(Only for optiPoint 410/420 standard/advance available)

(Only for optiPoint 410/420 standard/advance available)

(Only for optiPoint 410/420 standard/advance available)

Dialling Properties · Java HTTP Settings · LDAP settings

Administration Web-based Management Tool
Click on the required field to see a description for each parameter.
(Only for optiPoint 410/420 standard/advance available)

(Only for optiPoint 410/420 standard/advance available)

(Only for optiPoint 410/420 standard/advance available)

WAP gateway · WAP Favourites · Miscellaneous

Web-based Management Tool Administration
Click on the required field to see a description for each parameter.

Click on the required field to see a description for each parameter.


Audio settings · Diagnostic Tests · Test results

Administration Web-based Management Tool
Click on the required field to see a description for each parameter.
File Transfer (optiPoint 410/420 standard/advance)

(Only for optiPoint 410/420 standard/advance available)

LDAP FTP Settings

Web-based Management Tool Administration
(Only for optiPoint 410/420 standard/advance available)

(Only for optiPoint 410/420 standard/advance available)

File Transfer (optiPoint 410/420 entry/economy/economy plus)

Java FTP Settings · ENB FTP Settings

Administration Web-based Management Tool
Click on the required field to see a description for each parameter.
(LAN Port 2 Mode only for optiPoint 410/420 economy plus/standard/ad- vance available)

Network and Routing

Web-based Management Tool Administration
Quality of Service (QoS)
Click on the required field to see a description for each parameter.


SNMP settings

Administration Web-based Management Tool
Click on the required field to see a description for each parameter.

QoS Data Collection

Web-based Management Tool Administration
Click on the required field to see a description for each parameter.


DLS Settings · Gateway settings

Administration Web-based Management Tool
Click on the required field to see a description for each parameter.


Port Settings · Port Control

Web-based Management Tool Administration
Click on the required field to see a description for each parameter.


Only for optiPoint 410/420 economy plus/standard/advance with software version 5.x and higher on HiPath 3000/5000 (version 6.0 and higher) or Hi- Path 4000 (version 3.0 and higher).

SRSR Settings · Time Settings · VOIP Encryption Settings

Alphabetical Reference Description of functions
This glossary offers basic information that can be used by the administrator to carry out configuration- and diagnostics-related jobs in the optiPoint 410/ 420. • The Chapter “Description of functions“ explains alphabetically sorted terms that, for instance, you will encounter in the menus. The symbols lead to the concerned operational sequence descriptions:
Operating the optiPoint 410/420 economy/economy plus/standard/ advance
Operating the optiPoint 410 entry
Operating with the help of the web-based management tool • This is followed by the Chapter “Abbreviations and Specialized Terms“.
You will find more information in the relevant literature on the topics "Net- work Technology" and "Æ VoIP".
Æ page 50 · Æ page 45

Description of functions Alphabetical Reference
Application Version • Displays the version of the telephone SW. It contains informations about the functional range of the optiPoint 410/420 and could change by executing an update of the telephone SW (Æ Application Filename).
Asset Identity • Displays Informations about the Æ Properties of the Telephone Mod- els.

Alphabetical Reference Description of functions
Codec • Here you can select the audio transfer principle that should be used.
Codec Audio Mode Use of
Uncompressed audio transmis- sion use (Æ G.711). Suitable for broadband Internet connec- tions.
Use preferred com- pressed audio transmis- sion.
Suitable for connections with different bandwidths.
Use compressed audio transmission exclusively.
Suitable for connections with low bandwidth.

Description of functions Alphabetical Reference

Alphabetical Reference Description of functions
Æ page 22 Æ page 17 Æ page 52
Æ page 22 Æ page 17 Æ page 52
Æ page 21 Æ page 17 Æ page 52
DLS Server Port • Enter the Æ Port-Number for communication with the Æ DLS-Server .
DLS Server Address • Enter theÆ IP address of the Æ DLS-Server.

Description of functions Alphabetical Reference

Alphabetical Reference Description of functions
Factory Reset • With this function you can reset all administration parameters to the original settings at the time of delivery.
Resetting can lead to the failure of all functions of the optiPoint 410/ 420. Ensure that you have all the information necessary for the start up Æ page 14.
Æ page 34 Æ page 46

Description of functions Alphabetical Reference
Gateway Address • Enter the Æ IP address of the Æ PBX which operates with the optiPoint 410/420.
Gateway Port • Enter the Æ Port-Number for communication with the Æ Gateway- Server ein.

Alphabetical Reference Description of functions
Æ page 47 and Æ page 56
HTTPS • Enter the Æ Port-Number for communication with the HTTPS-Server (HTTP with SSL-encryption).

Description of functions Alphabetical Reference

Alphabetical Reference Description of functions
Jitter Buffer • Select the duration of the intermediate storage here (number of data packets) that changes the effect of the Æ Jitter.

Description of functions Alphabetical Reference
LAN Port Settings • Here you must define the bandwidth at which the optiPoint 410/420 should be run. The required value depends on the bandwidth that the switch or router supports in the network.
Auto in standard case
10/Full in 100 Mbit networks in full duplex[[1]] process
10/Half in 10 Mbit networks with half duplex[[2]] process
100/Full in 100 Mbit networks in full duplex[1] process
100/Half in 10 Mbit networks with half duplex[2] process
[1] Up to a date, the data can be simultaneously transmitted and received.
[2] Up to a date, the data can only be transmitted or received.
Æ page 23 Æ page 52
Æ page 47 and Æ page 56
Bandwith Possible application · Æ page 48 · Æ page 47

Alphabetical Reference Description of functions
SEARCHBASE "O=SIEMENS COMM, C=GB" organisation and speci- fication of country
SEARCHFILTER1 = "surnameNational,Surname" search criterion
search criterion (fast and advanced)
SEARCHFILTER3 = "department,Department" search criterion (advanced)
SEARCHFILTER4 = "localityShortCode,Location" search criterion
SEARCHFILTER5 = "ou,Org. Unit" search criterion (advanced)
SEARCHATTRIB2 =
SEARCHATTRIB3 =
SEARCHATTRIB4 =
SEARCHATTRIB5 = "ou,Organisational Unit,0" non-selectable field
SEARCHATTRIB6 = "localityNational,Location,0" non-selectable field
SEARCHATTRIB7 = "department,Department,0" non-selectable field
SEARCHATTRIB8 = "mainFunction,Function,0" non-selectable field

Description of functions Alphabetical Reference
Example for assumption (Copy & Paste)
optiPoint 410 LDAP TEMPLATE (V1)
SEARCHFILTER1 = "surnameNational,Surname" SEARCHFILTER2 = "givenNameNational,First-name" SEARCHFILTER3 = "department,Department" SEARCHFILTER4 = "localityShortCode,Location" SEARCHFILTER5 = "ou,Org. Unit"
SEARCHATTRIB1 = "commonNameNational,Name,0" SEARCHATTRIB2 = "telephoneNumber,Telephone,1" SEARCHATTRIB3 = "alternatePhone,Telephone 2,1" SEARCHATTRIB4 = "mobileTelephoneNumber,Mobile,1" SEARCHATTRIB5 = "ou,Organisational Unit,0" SEARCHATTRIB6 = "localityNational,Location,0" SEARCHATTRIB7 = "department,Department,0" SEARCHATTRIB8 = "mainFunction,Function,0"
Syntax of the LDAP template file
Examples of Searchbase:
SEARCHBASE = "" for no restriction
SEARCHBASE = "C=DE" for the Country "Germany"
SEARCHBASE = "O=SIEMENS,C=DE" for the Organisation "Siemens" in the Country "Germany"
Search Filter:
SEARCHFILTER# = "LDAP name1,Prompt2"
Search filters can be used up to five. Search filter 1 and 2 are used for the fast search, search filter 1 to 5 are used for the advanced search. All search filters are linked together by an "AND".
Search Attribute:
SEARCHATTRIB# = "LDAP name1,description3,[1|0]4"
Search attributes can be used up to eight. Contents of the field "SEARCHATTRIB1" are displayed in the result list.
1 The attribute name as defined in the data base which can be scanned. 2 The designation of the input field in the display of the optiPoint 410/420, assigned to the search field "LDAP name". 3 The designation of the result field in the display of the optiPoint 410/420, assigned to "LDAP name". 4 1 = The field contains a dialable number. 0 = The field contains a non-dialable value. If 1 is used, then a dial button is set beside this field and the number can be dialed.

Alphabetical Reference Description of functions
Port[ [1]]
Function LEDs on optiPoint 410/420 (right row)
PC Activity LED1 Not Active Active
Speed LED2 10 Mbit/s 100 Mbit/s
Duplex LED3 Half-Duplex Full-Duplex
(no function) LED4 - -
LAN Activity LED5 Not Active Active
Speed LED6 10 Mbit/s 100 Mbit/s
Duplex LED7 Half-Duplex Full-Duplex
(no function) LED8 - -
[1] See Æ page 12.
Æ page 50 · Æ page 25 · Æ page 28

Description of functions Alphabetical Reference
Location Identifier • Enter the number of the telephone stored on the server. The number automatically will be entered into the optiPoint 410/420 and shown in the Display (also called Local ID). Is no name available the Location Identifier Number (LIN) will be displayed.
MAC Address • Displays the Æ MAC address of a network terminal device (e.g., the optiPoint 410/420).
ifInDiscards Discarded ingoing packets
iflnErrors Non-valid ingoing packets
ifOutDiscards Discarded outgoing packets
ifOutErrors Non-valid outgoing packets

Alphabetical Reference Description of functions
Phone Identity • Displays the Phone Identity of the optiPoint 410/420.
Æ page 27 Æ page 49

Description of functions Alphabetical Reference
Æ page 23 Æ page 53
QoS Protocol Version • The Version Number gives information regarding the actuality of the QoS report file (read only).
Æ page 26 Æ page 49

Alphabetical Reference Description of functions
Report Mode • Choose the according Report Mode: – 1: A report will be sent at the end of a session when the threshold
threshold was reached. – 3: A report allways will be sent at the end of a session. – 4: A report allways will be sent within each Æ Report Interval.
Restart Terminal • Executes the restart of the optiPoint 410/420.
Æ page 26 Æ page 49
systems (test interface). It allows external feedback suggestions from messages to be entered in telephones thus enabling different scenarios to be tested. – Test Interface: This function permits automatic regression tests. Key-
strokes can be simulated and displays or audio statuses can be read out. – CTI: This function provides classic dialing assistance (for example, via
Windows dialing aid application). – Resource Sharing: The PC mouse and keys can be used to control
telephone applications (for example, DSM).

Description of functions Alphabetical Reference
Service Agent Request • Enter the Æ Port-Number for transfer of the Service Agent Requests.
Security Setting • Select the designated value from the list for the security setting for the Æ Gateway.
SNMP • Activate this field to deactivate read access to telephone data (for ex- ample, the device type can no longer be read via SNMP). The SNMP traps sent by a telephone are not affected by this.
SNMP Active • Activate the checkbox to run the Æ SNMP report.

Alphabetical Reference Description of functions
SNMP Trap Port • Define the Æ Port here through which the Æ SNMP error messages should be transmitted.
SRSR Automatic Switch Back • Activate this checkbox for executing automatical change between standby mode (emergency mode) and home mode (standard mode) of the communication plattform.

Description of functions Alphabetical Reference
Æ page 24 Æ page 55
Æ page 24 Æ page 55
System Type • Select the type of the used communication platform here (read only).

Alphabetical Reference Description of functions
Æ page 21 Æ page 17 Æ page 52
Æ page 21 Æ page 17 Æ page 52
Time Source • In this field, you specify how time is updated on your telephone.
System All settings are transferred from the system (Æ DHCP).
SNTP Enter the following parameters manually: Æ Default SNTP IP, Æ Timezone offset, Æ Daylight saving
Time Window • Messages sent by the gateway will be accepted only within this de- fined time window.

Description of functions Alphabetical Reference
Manual The ID entered in Æ Default VLAN ID is used.
DHCP If a Æ DHCP server is used, then the ID delivered by this server is applied.
Æ page 22 Æ page 17 Æ page 52

Alphabetical Reference Description of functions
Æ page 48 and Æ page 56
WBM Interface • If you activate this field, you can no longer administer the telephone via the Web-Based Management Tool. Administration is only possible via the local display or DLS.
Web Content Version • Displays the version number of the Software for access to the optiPoint 410/420 via the Æ Web-based Management Tool.

Abbreviations and Specialized Terms Alphabetical Reference
You will find more information in the relevant literature on the Network Technology and Æ VoIP.
The canonical format is an international standardisation of call numbers. In order for to be able to dial these numbers correctly, the dialing rules (con- version information) must be defined.
Example of a station number in canonical format:
Station number Local Area Code Local Country Code
This Siemens routing protocol is based on existing protocols, such as, H.323, MGCP, Megaco or the RTP protocol and includes signaling and con- trol functions necessary for IP telephony.
Abbreviation for "Dynamic Host Configuration Protocol". The dynamic assignment of IP addresses to the subscribers of an IP net- work with the help of a central DHCP server.
Abbreviation for„Deployment License Service“. DLS is a HiPath Management Application for Administration of Workpoints (optiPoint-Telephones und optiClient-Installations) in a HiPath- and non-Hi- Path-Network.
Abbreviation for "Domain Name System". Internet service for the conversion of voice address names into Æ IP ad- dress.
Standardization of telephone numbers according to the International Tele- phone Number Plan of ITU with a maximum of 15 digits. Usually assem- bled from the following components: Country Reference Number (CC, Country Code), Place Reference Number (NDC, National Destination Code) and Subscriber Number (SN, Subscriber Number).

Alphabetical Reference Abbreviations and Specialized Terms
Personal Telephonebook of the display module or application module.
Abbreviation for "File Transfer Protocol". Is used for transferring files in networks, e.g., to update telephone soft- ware Æ page 50.
Audio protocol for uncompressed voice transmission. Requires a band- width of 64 kbit/s.
Audio protocol for uncompressed voice transmission. Requires a band- width 128 kbit/s. This voice transmission supplies the best quality.
Audio protocol for compressed voice transmission. The quality is worse than in Æ G.711 and Æ G.729. Requires a bandwidth of about 6 kbit/s.
Audio protocol for compressed voice transmission. The quality is worse than in Æ G.711 and better than in Æ G.723. Uses a bandwidth of about 8 kbit/s.
Mediation components between two different network types, e.g., Æ IP network and ISDN network.
Abbreviation for "Hicom Feature Access". Sets up the connection between Æ IP telephony and a Æ PBX with the help of a gateway (e.g., HG 1500 or HG 3530) .
Abbreviation for "Hypertext Transfer Protocol". Protocol for the transfer of data in Æ IP networks.
Abbreviation for „Hypertext Transfer Protocol secure“. The HTTP protocol (encrypted via the SSL protocol) guarantees secure transmission of data in Æ IP networks.
Gateway · HTTPs

Abbreviations and Specialized Terms Alphabetical Reference
Abbreviation for "Internet Protokoll".
Also called "Æ IP" in short. The unique address of a terminal device in the network. It consists of four number blocks of 0 to 255 each, separated by a point. To simplify the notation, voice names can be released from a Æ DNS into the IP addresses.
Runtime fluctuations in data transmission in Æ IP networks.
Abbreviation for "Local Area Network".
2nd layer (Data Link Layer) of the 7-layer OSI model for describing data transmission interfaces.
3rd layer (Network Layer) of the 7-layer OSI model for describing the data transmission interfaces.
Abbreviation for "Lightweight Directory Access Protocol". Simplified protocol for accessing standardized directory systems, e.g., a company telephone directory.
Abbreviation for "Liquid Crystal Display". Display of numbers, text or graphics with the help of liquid crystal technology.
Abbreviation for "Light Emitting Diode". Cold light illumination in different colours at low power consumption.
Abbreviation for "Medium Access Control Address". A 48-bit address with the help of which a terminal device (e.g., Æ IP tele- phone or Network card) identifies itself uniquely in a network all over the world.

Alphabetical Reference Abbreviations and Specialized Terms
Abbreviation for "Management Information Base". Database containing descriptions of error messages of the devices and functions in a network.
Abbreviation for "Private Branch eXchange". Private telephone system that connects the different internal devices to the ISDN network
Abbreviation for "Packet Internet Groper". A program to test whether a connection can be made to a defined Æ IP target. Data is sent to the target and returned from there during the test. The result of the test displays the success / failure of the transmission and possible additional information such as the transmission time.
Ports are used in Æ IP networks to permit several communication connec- tions simultaneously. Different services often have different port numbers.
Abbreviation for "Pre Shared Secret". The PSS key is the master key used for data encryption in VoIP.
Abbreviation für „Quality of Service". Describes the subjectively ascertainable quality (service quality) of a voice connection through Æ IP networks. Properties of QoS are packet loss rate, packet delay, delay deviation, reserved bandwidth, type and bit rate (vari- able, constant or unspecified).
Abbreviation for "Random Access Memory". Memory with read / write access.
Abbreviation for "Read Only Memory". Memory with read only access.
Abbreviation for „Realtime Transport Protocol“.
Port · QoS

Abbreviations and Specialized Terms Alphabetical Reference
Abbreviation for "Session Initiation Protocol". Protocol standard for initialising calls in Æ IP networks.
Only for optiPoint 420 telephones. SLK (Self-Labeling-Key) means, that the labeling fields of the function keys automatically display the stored func- tions via LCD display.
Abbreviation for "Virtual Local Area Network". Subdivision of an Æ IP network into autonomous administration groups (domains). A possibility of characterizing the association with a VLAN is us- ing a Æ Default VLAN ID.
Abbreviation for "Simple Network Management Protocol". The protocol is used for communication with servers that takeover net- work management functions. This includes for example, protocolling er- rors that occur in network components (SNMPTrap).
Abbreviation for "Simple Network Time Protocol". The protocol is used between timeservers and terminal devices of a net- work to synchronize the time of the terminal device.
Abbreviation for "Small Remote Sites Redundancy".
Abbreviation for "Secure Real Time Protocoll" or "Secure Real Time Contoll Protocoll". The SRTP protocol is a more secure version of the Æ RTP protocol and is used in IP telephony for secure transmission of voice data between sta- tions. The SRTCP protocol determines the QoS characteristics for received streams. This provides senders with feedback that they can use to opti- mize voice stream emission.
Classifies networks in A-, B- and C networks. Each class has a subnet mask that demasks the relevant bits. 255.0.0.0 for Class A, 255.255.0.0 for Class B and 255.255.255.0 for Class C. In a Class C network, for instance, there are 254 Æ IP addresss.
Subnet Mask

Alphabetical Reference Abbreviations and Specialized Terms
Transmission position in a star-shaped network.
Abbreviation for "Voice over IP". E.g., voice transmission through Æ IP technology.
Abbreviation for "Wireless Application Protocol". Synonym for graphical applications on mobile telephones, organizers and other suitable terminal devices, transferred in accordance with the proto- col by the same name.
Abbreviation for "Wireless Session Protocol". Protocol for transferring data to Æ WAP-enabled terminal devices.
Switch · VoIP

Setting up the FTP server Administration scenarios
A correctly configured FTP server is necessary in all the cases, with the help of which, the data is exchanged through Æ FTP. The server program must run on the same computer (e.g., PC) in the Æ LAN in which the optiPoint 410/420 is run.
The installation of the "3Cserver" server program of the "3Com" company is described below as an example.

Administration scenarios Setting up the FTP server



Check handset functionalities Administration scenarios
optiPoint 410/420.
Check whether one or more of the mentioned questions are valid for your configuration:
Is the optiPoint 410/420 being run in a Æ VLAN ? • Enter the VLAN ID manually, or, if a Æ DHCP server is being used, set the “VLAN Method“ Æ page 81 on "DHCP" , so that the VLAN ID trans- ferred from the DHCP server is used. – More information on Æ Default VLAN ID.
Æ page 22 Æ page 53
Is the optiPoint 410/420 being run behind a Æ Gateway? • Enter the Æ IP address of the Gateway in Æ Default Route.
Æ page 22 Æ page 52
Other configuration possibilities ...
Æ page 27 Æ page 25
You can determine the version of the software that is running the optiPoint 410/420, e.g., during a pending software update.
Æ page 42

Administration scenarios Improve speech quality
“Compression“ Æ page 61. • Activate the suppression of the background noise during silence, for the optiPoint 410/420. – More information on “Silence Suppression“ Æ page 77.

optiPoint 410 entry only: The edited characters are displayed binary coded on the LEDs of the optiPoint 410 entry Æ page 100.
Permitted: Numeric values.
o Specify the numbers. < Press this key to delete one character at a time to the left. u v In case of negative numbers, press this key to change the prefixed sign.
optiPoint 410 entry only: It is not possible to edit an existing string. The string will be overwrit- ten by the new text.
Permitted: Integer values from 0 to 255 and dots (".").
q Press key to write dots between the IP fields.
Leading zeros will be ignored.
optiPoint 410 entry only: It is not possible to edit an existing string. The string will be overwrit- ten by the new text.
Number Editor Editors

Editors Teminal Mask Editor
Valid values: 0 Bit (000.000.000.000) to 32 Bit (255.255.255.255).
Bit Block 3 Block 2 Block 1 Block 0
0 0000
000
1 1000 0000
128 000 000 000
2 1100 0000
192 000 000 000
3 1110 0000
224 000 000 000
29 1111 1000
255 255 255 248
30 1111 1100
255 255 255 252
31 1111 1110
255 255 255 254
32 1111
255
q Press key to set a block’s value to "255".
r Press key to set a block’s value to "000".
> Press key to increment the value by 1 bit.
< Press key to decrement the value by 1 bit.
Binary code · Decimal code (input)

Character entry is performed by multiple presses of the keypad keys ac- cording to the following tables. This also applies to entry of alphanumeric passwords.
Example: "+" = press the r key 17 times.
Key 1x 2x 3x 4x 5x 6x 7x 8x 9x 10x 11x 12x e 1
f a b c 2
g d e f 3
h g h i 4
i j k l 5
j m n o 6
k p q r s 7
l t u v 8
m w x y z 9
r # . \ _ $ % / ( ) = [ ]
Key 13x 14x 15x 16x 17x 18x 19x 20x 21x 22x 23x r { } @ ~ + ; : " ’ ! ?
[1] Space.
[2] The next character to be entered will be interpreted as upper case.
optiPoint 410/420 economy/economy plus/standard/advance
< Press key to delete to the left.
: Press key to advance to the next character.
optiPoint 410 entry only
u Press key to advance to the next character.
It is not possible to edit an existing string. The string will be overwrit- ten by the new text.
Text Editor Editors · d [[1]] · q [[2]]

Factory Default Settings Standard value
Administration password Æ Password Functions
Application DL filename[[1]] ipphone.app
Audio mode G.711 always
Avg round trip delay threshold 100
Configuration DL filename OP400-28069
Consecutive good packets 8
Consecutive lost packets 2
Default route 0.0.0.0
DHCP IP assign on
DL server IP address 0.0.0.0
External Access[[2]] 9
FTP account name guest
FTP password Æ Password Functions
Gatekeepers 0.0.0.0
Gateway 0.0.0.0
H.225.0 Call Signalling 1720
H.245 TCP Channel 1720
Hold music filename MoHFile
International Prefix[2] 00
IP routing 0.0.0.0 (all)
LDAP server address[2] 0.0.0.0
LDAP server port[2] 389
Local Area Code[2] 115
Local District Code[2] 943

Standard value Factory Default Settings
Local Country Code[2] 44
Lost packet thresholds 10
Max jitter threshold 15
Minimal Session Length 255
National Dial Prefix[2] 0
QCU home address 0.0.0.0
QoS Layer 2 Default 0
QoS Layer 2 Voice/Signalling 5
QoS Layer 3 Signalling 26
QoS Layer 3 Voice 46
SNMP password Æ Password Functions
SNMP trap ID address 0.0.0.0
SNTP IP address 0.0.0.0
Switch To Home Expiry Timeout 20
Switch To Home Retry Count 3
Switch To Standby Expiry Timeout 20
Switch To Standby Retry Count 3
TC_TEST Expiry Timeout 20
TC_TEST Retry Count 3
Terminal IP address 0.0.0.0
Terminal mask 0.0.0.0
Time zone offset +0
VLAN ID 0
WAP mode[2] HTTP
WAP server address[2] 0.0.0.0
WAP server port[2] 9200
[1] Filename is postfixed by a letter a, b, c or d for the various language packages. [2] optiPoint 410 standard/advance, optiPoint 420 advance only

Factory Default Settings Password Functions
The minimum password length can be predefined in the Deploy- ment Tool.
User Password Protects the user-specific settings of the optiPoint 410/420.
Administrator Password Protects the administration area from unau- thorized access („Configuration" and „Diag- nostics").
FTP Password Protects the FTP server from unauthorized access for data transmission (e.g., Down- loading of firmware).
HiPath Password Protects the settings for communication with other HiPath devices.
SNMP Password Protects the SNMP server from unautho- rized access for error assessment.
Subscriber Password Protects the transfer of the subscriber num- ber and configuration settings to another telephone.
Cancel Mobility Password Protects resetting in case of a transfered subscriber number to another telephone.
Password Function setting

Programmable Keys optiPoint 410/420 economy/economy plus/standard/advance Factory Default


Data Visualisation (optiPoint 410 entry only) Status Messages

For error messages on the optiPoint 410 entry see Æ page 35.
The table illustrates in which way characters are displayed on the LEDs of the optiPoint 410 entry.
LEDs . 0 1 2 3 4 5 6 7 8 9

Binary encoded ASCII table Technical data
Protocols H.323, H.225, H.245, TCP/IP, FTP, DHCP, SNTP, SRTP/SRTCP[[1]]
Gatekeeper routed and direct routed call model
Voice algorithms G.711 (64 kbit/s), G.723.1 (6,4 kbit/s) Room echo compensation
Interfaces IEEE 802.3 Fast Ethernet (10/100 Mbit/s) 2 x RJ 45 TP
Pin assignment: LAN receptacle Pin 1 TX + Pin 2 TX - Pin 3 RX + Pin 4 -- (DC+) Pin 5 -- (DC+) Pin 6 RX - Pin 7 -- (DC-) Pin 8 -- (DC-)
Handset receptacle Pin 1 microphone - Pin 2 receiver cap + Pin 3 receiver cap - Pin 4 microphone +
Power supply unit receptacle
Pin 1 V - Pin 2 -- Pin 3 -- Pin 4 -- Pin 5 -- Pin 6 V +
Power supply (external plug-in power supply unit)
EU-variant, grounding plug (230 V, 50 Hz) UK-variant (230 V, 50 Hz) US-variant (110 V, 60 Hz)
[1] Only for optiPoint 410/420 economy plus/standard/advance with software version 5.x or higher on HiPath 3000/5000 (version 6.0 or higher) and HiPath 4000 (version 3.0 or higher).

Technical data Binary encoded ASCII table
Protocols H.323, H.225, H.245, TCP/IP, FTP, DHCP, SNTP Gatekeeper routed and direct routed call model
Voice algorithms G.711 (64 kbit/s), G.723.1 (6,4 kbit/s) Room echo compensation
Interfaces IEEE 802.3 Fast Ethernet (10/100 Mbit/s) 2 x RJ 45 TP
Pin assignment: LAN receptacle Pin 1 TX + Pin 2 TX - Pin 3 RX + Pin 4 -- (DC+) Pin 5 -- (DC+) Pin 6 RX - Pin 7 -- (DC-) Pin 8 -- (DC-)
Handset receptacle Pin 1 microphone - Pin 2 receiver cap + Pin 3 receiver cap - Pin 4 microphone +
Power supply unit receptacle
Pin 1 V - Pin 2 -- Pin 3 -- Pin 4 -- Pin 5 -- Pin 6 V +
Power supply (external plug-in power supply unit)
EU-variant grounding plug 230 V, 50 Hz (AUL:06D1284)
UK-variant 230 V, 50 Hz (AUL:06D1287)
US-variant 110 V, 60 Hz (AUL:51A4827)

optiPoint 410/420Operation Codes Summary
In the following pages you will find a list of the reference numbers corresponding to the administration and diagnostics functions in the optiPoint 410/420 economy/economy plus/ standard/advance and the optiPoint 410 entry in the alphabetical order.
Administration Interface
Operation optiPoint 410/420 economy/ economy plus
optiPoint 410/420 standard/ advance
edg (simult.) o r Æ page 20
edg (simult.) o r Æ page 32
Operation optiPoint 410/420 economy/ economy plus (Æ Administration Interface)
optiPoint 410/420 standard/ advance (Æ Administration Inter- face)
Refer to · Refer to

Operation Codes SummaryoptiPoint 410/420
Operation optiPoint 410/420 economy/ economy plus (Æ Administration Interface)
optiPoint 410/ 420 standard/advance (Æ Administration Inter- face)
Audio Loop Test dh s dh s Æ page 59
SLK Test[[1]]
[1] Only for optiPoint 410/420 standard/advance available
Refer to

optiPoint 410 entryOperation Codes Summary
Administration Interface
Operation optiPoint 410 entry Refer to
Configurations edg (simult.) o r Æ page 20

DHCP IP Assignment dd o r Æ page 62
Factory Reset flm (simult.) o r Æ page 64
Terminal IP Address de o r Æ page 80

Restart ehk (simult.) o (Administration password) r

The following table shows a concerned overview of the menu structure of the optiPoint 410/420.
Menu Operation steps Explanation |--- Administration? | |--- 01=Configuration? | | |--- 01=DHCP IP assign? Æ page 21 Æ page 62 | | |--- 02=Terminal IP addr.? Æ page 21 Æ page 80 | | |--- 03=Terminal mask? Æ page 21 Æ page 80 | | |--- 04=Default route? Æ page 22 Æ page 62 | | |--- 05=VLAN method? Æ page 22 Æ page 81 | | |--- 06=VLAN id? Æ page 22 Æ page 62 | | |--- 07=QoS? | | |--- 08=LAN port 1 mode? | | |--- 09=LAN port 2 mode? [1] | | |--- 10=Fully qual sub num? Æ page 24 Æ page 79 | | |--- 11=Home subscriber pwd? Æ page 24 Æ page 79 | | |--- 00=End? | |--- 02=Diagnostics? | | |--- 01=Display test? Æ page 25 Æ page 62 | | |--- 02=LED test? Æ page 25 Æ page 72 | | |--- 03=Key test? Æ page 26 Æ page 68 | | |--- 04=Audio loop test? Æ page 26 Æ page 59 | | |--- 05=RAM test? Æ page 26 Æ page 75 | | |--- 06=ROM test? Æ page 26 Æ page 76 | | |--- 07=Ping Test? Æ page 27 Æ page 74 |--- 01=User specified IP |--- 02=Gateway? |--- 03=DL server address? |--- 04=Default Router IP? |--- 05=Route 1 Gateway IP? |--- 06=Route 2 Gateway IP? |--- 07=SNMP trap address? |--- 08=Terminal IP addr.? |--- 09=DNS Server? |--- 10=SNTP IP? |--- 00=End? | | |--- 08=Line Test? Æ page 28 Æ page 72 | | |--- 09=SLK test? [2] Æ page 28 Æ page 77 | | |--- 00=End? | |--- 03=Start Phone?
[1] Only for optiPoint 410/420 economy plus/standard/advance available [2] Only for optiPoint 420 Workpoints available
Menu structureoptiPoint 410/420


H H.225.0 Call Signalling 56, 66 H.225.0 RAS 56, 65 H.245 TCP Channel 56, 66 Handsfree distance 3 Help Internet URL Base 48, 66 HTTP Gateway/Proxy Address 47, 66 HTTP Password 47, 66 HTTP Port Number 47, 56, 66 HTTP Username 47, 67 HTTPS 56, 66
Local Country Code 47, 73 Local District Code 47, 73 Location Identifier 55, 73
M MAC Address 45, 73 Menu structure 106 MIB-II Error Count 49, 73 Minimal Session Length 54, 74
I Improve speech quality 92 IP Routing 52 , 67
Values 54, 74
O Observation Interval 54 , 74 Operation Codes Summary 103
K Key Test 26
P Packet size 49, 74 Password 45, 59 Phone Identity 45, 74 PING Test 27, 74 Port Control
L LAN connection checking 91 LAN Port Settings 23, 24, 52, 69 Layer 2
CTI 56 Debug Interface 56 Probe Interface 56 Resource Sharing 56 Service Agent 56 SNMP 56 Test Interface 56 WBM Interface 56 Precautions 2 Programmable Keys 99
Default 53, 68 Layer 3
Signalling 53, 68 Voice 53, 68 LDAP
configurieren at application module 41 configuring at display module 39 install template 39, 41 Server IP Address 47, 69 Server Port 56, 69 template example 70 Template Filename 50, 72 LED
Q QCU Home Address 54, 75 QCU Standby Address 54, 75 QDC Server 56, 75 QoS Layer Options 23, 53, 75 QoS Protocol Version 54, 75
Visualisation on optiPoint 410 entry 100 LED Test 25, 72 Line Status 28, 72 Local Area Code 47, 73
Index

R RAM Test 26, 49, 75 Report Interval 54, 75 Report Mode 54, 76 Restart Terminal 29, 33, 46, 76 ROM Test 26, 76 RTP Port Base 56, 76
Terminal IP Address 17, 21, 52, 80 Terminal Mask 17, 21, 52, 80 Time source 57 Time window 55, 80 Timezone offset 57
S Security Setting 55, 77 Serial number 7 Service Agent Request 56, 77 Silence Suppression 49, 77 SNMP 77 active 53, 77 Password 53, 77 Server Address 53, 78 Trap Port 53, 78 Software-Version, determine 91 Specialized terms 83 SRSR
ID 22, 62 Method 22, 81 VoIP security 8, 57
Access Allowed 48, 81 Access User Name 48, 81 Favourites 48, 81 Gateway Port Number 56, 82 Home Page 48, 82 Mode 48, 81 Server Address 48, 82 Title 48, 82 URL 48, 82 Web Content Version 45, 82 Web-based Management Tool 42
Automatic Switch Back 78 Enabled 78 Switch To Home Expiry Timeout 78 Switch To Home Retry Count 78 Switch To Standby Expiry
Timeout 78 TC_TEST Expiry Timeout 79 TC_TEST Retry Count 79 Start up not successful 91 Subscriber Number 24, 55, 79 Subscriber Password 24, 55, 79 Switch To Home Expiry Timeout 57 Switch To Home Retry Count 57 Switch To Standby Expiry
Timeout 57 Symbole 58 System Type 55, 79
optiPoint 410 eco/sta 101 optiPoint 410 entry 102 optiPoint 410/420 advance 101
Index

© Siemens AG 2005 Siemens Communications Hofmannstr. 51 • D-81359 München
The information provided in this document contains merely general de- scriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. The trademarks used are owned by Siemens AG or their respective owners.
Bestell-Nr.: A31003-A2056-B415-7-76A9
Subject to availability. Right of modification reserved. Printed in the Federal Republic of Germany. 09.11.05
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.