R FU-40SE-K Ta b letop / wall-mounting type AIR PURIFIER OPERA TION MANU AL.
.
FEA TURES Cluster Ion Contr ol The unit controls the ratio of minus cluster ions and plus cluster ions depending on the condition of the room. • Clean mode Appro ximately the same amount of plus and minus cluster ions are discharged. This mode is eff ective f or reducing floating mold and household odors in the air .
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loose. Electrical shock, shor t circuit and/or fire ma y occur as a result. • Do not damage, break, coat, f orcefull y bend, pull, twist, bundle, pinch or place hea vy objects on the power cor d.
CA UTIONS CONCERNING THE USA GE OF THIS PR ODUCT • Do not bloc k the intake and exhaust ports. • Do not use the unit near or on hot objects, such as a sto ve, etc. Also , do not use the unit where it ma y come into contact with steam. • Do not use the unit on its side.
Plasmacluster NAMES OF P AR TS MAIN UNIT DISPLA Y Filter timer lamp AU TO operation lamp F an level lamps * T obacco smoke mode oper ation lamp Pollen mode operation lamp OFF timer displa y lamps (set.
AC CESSORIES Remote control (1 unit) Battery (AA batter y X 2 units) When used on a tabletop Stand (1 unit) Thumbscrew (2 units) Located on bottom of stand CLUSTER ION LAMP Cluster ion operation is selected using the remote control.
INST ALLA TION WHEN USING THE UNIT ON A T ABLET OP FIXING THE ST AND 1 Remove the fr ont panel. • At this time, also remo ve the pre-filter , stamina-pow er carbon and the HEP A filter . Front panel 2 Place the unit with its front side facing down on a flat and stable surface.
Mount the brac k et to the back of the main unit using the small scre ws included. 3 Place the cushions as sho wn 4 Mount the main unit (1) Align the horizontal positions of mounting brack ets 1 and 2 and hook the brack et 2 to brack et 1. (2) Hold the bottom of the main unit, pull the unit to- w ards y ou and then pull down.
PREP ARA TION Be sure to remove the power plug from the wall outlet. INST ALLING THE FIL TERS To maintain the quality of the filters, the y are installed in the main unit within polyvinyl bags . Be sure to remove the filters from the polyvinyl bags before using the unit.
2 Install the filter 1 Remo ve the HEP A filter from the polyvinyl bag and install it in the main unit with the display facing up. Inser t so that the tabs on the HEP A filter are f acing you. Proper operation cannot be achie v ed if installed incorrectly .
OPERA TION MAIN UNIT OPERA TION The unit will start operation when the MODE-ON/OFF button is pressed. (The unit will star t oper ation in A UTO mode) • During operation, the cluster ion lamp will light. (During star t of operation, the cluster ion mode will be A UT O) The operation mode suitab le for the usa ge condition can be set.
REMOTE CONTROL OPERA TION •T o star t operation, press the ON/OFF b utton. A short beep will sound and operation will start in the AU TO mode. •T o stop operation, press the ON/OFF b utton again.
CARE AND MAINTENANCE (T o maintain the best perf ormance of this product, please clean the unit per iodically .) When cleaning, be sure to remove the power plug from the wall outlet. In addition, never handle the power plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
Guide for filter replacing timing • The f ollo wing is a guide from JEM 1467 b y Japan Electrical Manuf acturers Association in Japan, and in JEM 1467, the replacement period is set as when smoking 10 cigarettes per da y and the dust collection/deodorization power is reduced b y half that of new filters .
TROUBLESHOOTING Before calling f or repair , chec k the symptoms below f or possib le remedies, since the problem ma y not be a malfunction of the unit.
An important point after buying a device Sharp FU-40SE-K (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sharp FU-40SE-K yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sharp FU-40SE-K - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sharp FU-40SE-K you will learn all the available features of the product, as well as information on its operation. The information that you get Sharp FU-40SE-K will certainly help you make a decision on the purchase.
If you already are a holder of Sharp FU-40SE-K, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sharp FU-40SE-K.
However, one of the most important roles played by the user manual is to help in solving problems with Sharp FU-40SE-K. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sharp FU-40SE-K along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center