OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035- 80749-00.
TA BLE OF CONTENTS A C880 B e f o r e U s i n g t h e A C 8 8 0 ..................... 2 S a f e t y P r e c a u t i o n s .......................... 2 U s i n g t h e A C 8 8 0 ........................... 3 S e t u p ..................................
Page 2 BEFORE USING T HE A C880 Check for any shipping damage. Place a claim with carrier if damage is disc overed. DO NOT USE A DAMA GED UNIT. Complete and retur n the Warr anty Card to ac tivate te chnical s upport ser vice and w arra nty coverage.
Page 3 USIN G T HE A C880 Note: The purpose of this discus sio n is to fa m iliarize the user with t he features and functions of the AC880 Refrigerant Handling Station.
Page 4 SETUP 1 Low Pressure Gauge 7 Oil Charge - High Side 13 Fill Port 2 Keypad 8 Red Hose - High Side 14 Refrigerant Cylinder 3 Power Switch 9 Blue Hose - Low Side 15 Y ellow Hose w/Anti-blowback 4 .
Page 5 N N N N N N N N N N N N EXTREMELY IMPOR TA NT N N N N N N N N N N N N Always connect Y ellow Hose (15) to Cylinder (14) first and then connect other end of hose with anti-blowback valve to Fill Port (13) on AC880. WEIGHT = XX.X LB AUTOMA TIC ? # >>>> WEIGHT = XX.
Page 6 WEIGHT = XX.X LB AUTOMA TIC ? # > WEIGHT = XX.X LB RECYCL E ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER CHECK HO SES START ? # ENTER WEIGHT = XX.
Page 7 DRA IN RECOVERED OIL Oil is separated from the recove re d refrigerant and MUST be removed following EACH Recover/ Recycle procedure to determine the amount (if any ) necessary to add into the A/C Sy stem as follows: Note: The AC880 must be connected to pow er source.
Page 8 WEIGHT = XX.X LB AUTOMA TIC ? # >> WEIGHT = XX.X LB VACUUM ? # ENTER * A/C HAS PR ESSURE GO TO RECY CLE # ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < .
Page 9 WEIGHT = XX.X LB AUTOMA TIC ? # >>> WEIGHT = XX.X LB CHARGE ? # ENTER ENTER CH ARGE AMOUNT = XX.X LB # >< ENTER * LOW LEVEL , GO T O FILL CY LIND ER # ENTER CHECK H IGH- LOW CHARGE S WITCH # ENTER WEIGHT = XX.X LB CHARGI NG CHARG E COMP LETE EVAC HOS ES # ENTER CHA RGE 1.
Page 10 WEIGHT = XX.X LB AUTOMA TIC ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < ENTER ADD OIL ? Y/N # < ENTER ENTER CH ARGE AMOUNT = XX.
Page 11 WEIGHT = XX.X LB COMPRE SSOR OFF * HIGH PR ESSU RE SEE MAN UAL ** CYLIND ER FULL GO TO CHAR GE # TIME LE FT=X X MIN PUMP ON PUMP OFF XX MIN CONTIN UE ? # ENTER ADD OIL NO W CONTIN UE ? # ENTER WEIGHT = XX.
Page 12 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # ENTER FILTER H OURS= XX.X HOU RS > TOTAL R ECYC LED= XXXX.X K G > TOTAL C HARG ED= XXXX.X K G > A CCESS ST ORED DA TA 1. Set up the AC880 and t urn the Main Power Switch ON.
Page 13 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # Calibration Switch WEIGHT = XX.X LB CHARGI NG > OVER CH ARGE AMOUNT = X.XX KG # >< ENTER SET OVER CHA RGE A MOUNT 1. Remove the front panel of the AC880.
Page 14 SCHEDULED MA INT ENA NCE DA IL Y... Che ck the oil le vel in t he Vacuum Pump while the pump is running. The Vacuum Pum p Oil Level Sight Glass is visible thr ough a hole in the Lower Rear Panel of the AC880. The oil l evel s hould be at the “half-way” point of the glass.
Page 15 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 360-81555-00 Manifold Assy 880 120V 2 024-80037-00 Contactor ½ HP (120V) 3NO/1N C 3 024-80066-00 Rocker Swi tch SPDT Visired N on-lig hted 4 360-803.
Page 16 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 026-80077-00 Combo Filter 3/8 Fl are (Long) 2 360-81192-00 Compressor Inlet Tube Assy 3 360-81197-00 Accumulator Assy 4 360-81356-01 Compressor Assy .
Page 17 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 024-80040-00 Rocker Swi tch SPDT (on-on) Amber 125V 2 024-80060-01 Circuit Boar d 120V 3 026-80065-03 Gauge 30"-120 Psig 1/4 MFL 3.
Page 18 T ROUBLESHOOTING FILL CYLINDER PROCEDURE 1) The cy linder of new refrigerant should be at ambient temperature or great er for best performance of the Fill Cylinder procedure. Make sure the cy linder was not recently moved from an air-conditi oned storage ro om to a w arm w ork a rea .
An important point after buying a device Sharp AC880 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sharp AC880 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sharp AC880 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sharp AC880 you will learn all the available features of the product, as well as information on its operation. The information that you get Sharp AC880 will certainly help you make a decision on the purchase.
If you already are a holder of Sharp AC880, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sharp AC880.
However, one of the most important roles played by the user manual is to help in solving problems with Sharp AC880. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sharp AC880 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center