IAS-MO 2000 Set Instructions for use LEVEL OVERLOAD 0 0 40 20 +/- 15dB dB GAIN Industry Acoustic System.
.
1 Contents Safety instructions .......................... .............. .............. ................. .............. ............... . 2 IAS-MO 2000 Set ............ .............. ................. .............. .............. ................. .
2 Safety instructions This instruction manual contains impor tant safety information. Read this inst ruction manual. Keep this instruction manual in a safe place. Al ways include this instru ction manual when passing the system on to third parties. Heed all warni ngs.
3 Operation T hi s de v i c e mu s t b e op e ra t e d o nl y f r o m t h e t y pe o f p o we r su p p ly i n d i c a t e d on the type plate. Observe c orrect polarity! Ne ver push ob je cts of an y .
4 IAS-MO 2000 SET The IAS-MO 2000 Set system cons ists of the fol lowing main components : y 1 MO 2000 Set optical microphone system y 1 MZWW 2000 weat her and wind protecti on The IAS-MO 2000 Set system meets the re quirements of the A TEX directive.
5 Delivery includes IAS-MO 2000 Set y 1 MO 2000 H optical microphone with 3 m fiber optic cable y 1 MO 2000 CU central unit y 1 mains unit with di fferent country adapters y 1 GA 2 rack adapter y 1 ca.
6 Product overview IAS-MO 2000 Set Gain switch (coarse adju stment) Level control (fine adjustment), with 0 dB mark OVERLOAD LED ON/OFF button Cable grip for powe r supply DC cable.
7 Putting the system into operation You can set up the device on an even surface or mount it into a 19” rack. Note: Do not fit the rubber feet wh en rack mounting the device.
8 To m o u n t two ce ntral units into a rack: 왘 Place the two central units si de by si de upside-d own onto a flat surface. 왘 Align the join ting plate over the holes in the bottom sides of the central units. 왘 Secure the jointing plate to the central units using eight of the supplied recessed head screws (M 3x6).
9 Connecting the optical microphone 왘 Before connecting the opti cal microphone, remove the protections caps from the microphone connections and of the central unit. Keep the protection caps in a safe place for re use during transpo rt or storage.
10 Connecting the optical microphone to the weather and windshield 왘 Remove the windshield basket and op en the flap in the pipe as shown. 왘 Remove the protectio n caps from th e c onnectors of the fiber optic cable . 왘 Push down the plastic housing on an even base until the h ousing detaches from the connectors with an audible clic k.
11 Switching the central unit on/off Af ter connection to the mains, the device sw itches on automatically and the ON button lights up. 왘 Press the ON button to switch the MO 200 0 CU central unit on or off. Note: If the power supply is interrupted for several seconds (e.
12 Disassembling the weather and wind protection Accessories Cat.-No. Accessory 009823 GA 2 rack adapter 525700 MO 2000 H optical microphon e 525701 MO 2000 CU central unit 525702 Pipe 522170 SCRJ-GOF.
13 Care and maintenance T o clean the MO 2000 CU central unit: 왘 Before cleaning, disconnect the device from th e mains. 왘 Use a sof t, dry cloth to clean the device. T o clean the MZWW 2000 weather and wind protection: 왘 Use a sof t, slightly da mp cloth to clea n the weather and wind protection.
14 Specifications MO 2000 CU central unit Housing 1 / 2 19” metal housing Front panel connections and controls ON/OFF button with operation indicator, OVE RL OAD LE D, gain control (coarse adj ustme.
15 Fiber optic extension cable (optional) Interface SC Design multimode 20 0/230 μ m Cable loss approx. 3–4 dB per 100 m Optical transducer (optiona l) Interface socket/socket Design type SC Coupli.
16 Manufacturer Declarations W arranty Sennheiser GmbH & Co. KG gives a warranty of 24 months on this p roduct. For the current warran ty conditions, please visit our web sit e at www.
.
Sennheiser electronic GmbH & Co. KG Am Labor 1 30900 W edemark, Germany Phone +49 (513 0) 600 0 Printed in Germany Fa x +49 (5130) 600 300 Publ. 08/08 www.
An important point after buying a device Sennheiser Industry Acoustic System IAS-MO 2000 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sennheiser Industry Acoustic System IAS-MO 2000 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sennheiser Industry Acoustic System IAS-MO 2000 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sennheiser Industry Acoustic System IAS-MO 2000 you will learn all the available features of the product, as well as information on its operation. The information that you get Sennheiser Industry Acoustic System IAS-MO 2000 will certainly help you make a decision on the purchase.
If you already are a holder of Sennheiser Industry Acoustic System IAS-MO 2000, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sennheiser Industry Acoustic System IAS-MO 2000.
However, one of the most important roles played by the user manual is to help in solving problems with Sennheiser Industry Acoustic System IAS-MO 2000. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sennheiser Industry Acoustic System IAS-MO 2000 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center