EN
Sears logo
Official user manual

Sears 390.2508

16 pages·850 KB·Water Pump·PDF·ENDEFRITNLJA
Sears 390.2508
Table of Contents 80 sections SEARS · OWNER'S · MANUAL · 390.2508 · … ShowHide
SEARSp.1OWNER'Sp.1MANUALp.1390.2508p.1CRAFTSMAN ° HYDROGLASS ® SHALLOW WELL JET PUMPp.1CAUTION:p.1Read andFollow All Safety Rulesandp.1GENERAL INFORMATIONp.3Table h Pump Performance Chart (In Gallons Per Minute)p.3MAJOR COMPONENTS AND WHAT THEY DOp.3PIPINGp.3Piping in the Wellp.323140E96p.3Figure Ip.3Pressure Switchp.3Couplin9 Not Orive to Point Scalep.3MODEL NO. PUMP STARTS AT [PUMP STOPS AT 390.2508 _ / _p.3Check Valve or Foot Valvep.3PIPING INSTALLATIONp.4Cased Open Well Waterp.41-1/2"p.4Discharge Pipe Sizesp.4ELECTRICALp.5Motor Switch Settingsp.5Dial Type Voltage Selectorp.5Remove Hotor End Coverp.5Figure 5 - Voltage Set To 230 Volts, Dial Typep.5Figure 4 - Removing Motor End Coverp.5WIRING CONNECTIONSp.6Figure 6 - Pressure switch wiringp.6TABLE Ih WIRING CHART - Recommended Fusing and Wiring Datap.6Priming the Pumpp.7Disassembly and Assembly of Pumpp.7Removing Motor for Service and Replacing Shaft Sealp.7MAINTAINING YOUR PUMPp.7Lubricationp.7Draining for Winterp.7CARDBOARDWASHERp.8MOTOR FLANGE SCREWDRIVERp.8D WITHSEALp.8HALFp.8PUMPBACKp.8MOTORp.8_CREWDRIVERp.8TOP OF MOTOR FLANGEp.8COPPER SEATp.8SEAL PLATE INDEX PINS SLIDE IN HERE Figure I OAp.8FLOATINGp.8SEATp.8MEMBERp.8MOTOR FLANGEp.8SEAL PLATEp.8INDEX PINSp.8Figure I OBp.8SEAL PLATE HOLES MUSTp.9LINE UPp.9DIFFUSERp.9FACE OF SEALING WASHERp.9IMPELLER HUBp.9SHAFT SHOULDERp.9% BE SURE NIBS ENGAGE NOTCHESp.9RUBBER DRIVE RINGp.9Installing Copper Insertp.9Figure I Ip.9TO DISASSEMBLEp.9BE SURE RUBBER PAD STAYS IN PLACE ONp.9BESURESCREW ENGAGES HOLE IN SEALPLATEp.9RIB AT E O'CLOCKp.9PRIMING HOLEp.9Cleaning Shallow Well Jetp.10HELPFUL HINTSp.10How to Handle a Gaseous Wellp.10Remove /_ pUr=U'p.10Not pipep.10to valvo Scalep.10Figure I 7p.10Cleaning Impellerp.10Air Control in Flowing Wellsp.10TROUBLESHOOTING CHARTp.11SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTIONp.11
Page 1 of the Sears 390.2508 user manual — 390.2508
Page 1 · click to enlarge
Page 1
Sears 390.2508 — SEARS diagram (page 1)
Fig. 1

SEARS

OWNER'S

MANUAL

MODEL NO.

390.2508

CRAFTSMAN ° HYDROGLASS ® SHALLOW WELL JET PUMP

CAUTION:

Read andFollow All Safety Rulesand

Operating Instructions Before FirstUse of This Product.

  • Safety Instructions
  • Installation

Save ThisManual For Future Reference.

  • Troubleshooting
  • Repair Parts

Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.

PRINTED IN USA. Form No F642-04072 (Rev 2/15/05)

Page 2 of the Sears 390.2508 user manual — SEARS
Page 2 · click to enlarge
Page 2
Page 2 of the Sears 390.2508 user manual — SEARS
Page 3 of the Sears 390.2508 user manual — Couplin9 Not Orive to Point Scale
Page 3 · click to enlarge
Page 3
Sears 390.2508 — GENERAL INFORMATION diagram (page 3)
Fig. 2

GENERAL INFORMATION

Table h Pump Performance Chart (In Gallons Per Minute)

Discharge Pump Suction Discharge Pressure Pumping Depth in Feet

Model Description Size Size P.S.I. 5' 10' 15' 20'

390.2508 1/2 HP Standard S.W. Jet 1-1/4" 3/4" 40 7.3 6.2 5.2 4.2

MAJOR COMPONENTS AND WHAT THEY DO

PIPING

Piping in the Well

ie Tee Water System and Priming Plug

A Shallow well jet pump can be installed on a dug well, drilled well or with a driven point. In a dug or ased well, a foot valve and strainer should be installed for easy priming. It should be five to ten feet below the lowest level to which the water will drop while pump is operating (pumping water level).

The strainer should not be too close to the bottom or sedi- ment may clog it. Before installing the foot valve, check to see that it works freely.

When installed on a driven pont well, your Shallow Well Jet Pump should have a check valve installed as shown in Figure 2.

23140E96

To Household Discharge Tee

Figure I

Water System f- and Priming Plug

Impeller turns with motor shaft, causing the water to fly out from its rim by centrifugal force. Impeller rotation creates a vacuum which puUs in more water. Part of the water is di- verted back to the jet where it passes through the nozzle and venturi. This creates more vacuum to draw in more water.

In shallow wells (less than 20 feet deep), the vacuum cre- ated at the pump is enough to pull water to the pump. Therefore, for shallow well use the jet is built into the pump. Air Volume Control

The air volume control (AVC) maintains the cushion of air in Standard tanks.

Pressure Switch

The pressure switch provides automatic control.

Couplin9 Not Orive to Point Scale

MODEL NO. PUMP STARTS AT [PUMP STOPS AT 390.2508 _ / _

Check Valve or Foot Valve

This pump is equipped with a built-in check valve. Install a foot valve in the well on dug or cased wells. See Figure 3, Page 4. Tank

For a pump at sea level, be sure the vertical distance (lift) from the pumping water level to the pump is not over 20 feet if the pump is over the well. This wll be less if the pump is offset from the well.

The tank serves two functions. It provides a reservoir of water, some of which can be drawn through the house fix- ture before the pump must start. It maintains a cushion of air under pressure.

The maximum lift of any pump decreases at the rate of about 1' less lifx for every 1,000 feet elevation above sea level. For example, if your are at 5,000 feet elevation such as in Denver, Colorado, you would loose five feet of llfx. The max- imum depth from which oyou could pump water would therefore be 15 feet.

Two types of tanks are available: Captive Air® and Standard. No air vohtme control is needed with Captive® Air Tanks.

Show 6 more labels / short text on this page
Relief Valve · Built-in · Check Valve · Impeller and Jet · II _--Relief Valve · Drive Point
Page 4 of the Sears 390.2508 user manual — Discharge Pipe Sizes
Page 4 · click to enlarge
Page 4
Sears 390.2508 — PIPING INSTALLATION diagram (page 4)
Fig. 3

PIPING INSTALLATION

ff horizontal suction pipe is more than 25' long, install a priming plug at well head to allow filling of pipe.

Cased Open Well Water

SEARS jet pumps should be used vdth Captive Air® Tanks (see Figure 2, Page 3). For mounting pump to tank, pur- chase tank fittings Kit No. 2788.

SEARS Captive Air* Tanks are pre-charged with air at the fac- tory. Check the tank Owner's Manual to find if air charge needs adjustment. Pump model 390.2508 requires 30 pounds for proper operation.

The Jet pump can also be mounted on standard horizontal tanks. A mounting kit with an AVC is furnished with tank (Figure 1, Page 3). Instruction are also included.

The installation, operation and care of your Hydroglass® pump is very similar to cast iron pumps. We ask, however, that you keep the following points in mind.

1. Wrap one and one-half to two layers of Teflon tape on all male threads being attached to pump. This vdll insure leakproof connections. Do not overtighten threaded fiv tings in the plastic pump. If leaks do occur, remove the fitting, clean off the old Teflon tape, rewrap with one and one-half to two Myers of new tape and remake the connection.

Horizontal Piping From well To Pump

When the pump is offset more than 25 feet from the well, horizontal piping should be increased in size to reduce fric- tion losses. In no case should the offset piping be smaller than the suction tapping of the pump.

Be sure to support all piping connected to your Shallow Well Jet Pump.

To connect AVC to the pump, remove the 1/8" pipe plug (Key No. 13, Page 11) from the jet portion of the pump body near the suction tapping. Insert a 1/8" fitting into this tapping. Cut tubing to length and assemble the two fittings on the air volume control and pump body.

Horizontal Offset Piping Sizes for Shallow Well Jets

1-1/2"

t 1-1/4" Up to 25 Ft.

25 to 50 Ft.

50 to 200 Ft.

Discharge Pipe Sizes

When the pump is set at a distance from the house or point of water use, the discharge pipe size should be increased to reduce pressure losses caused by friction.

1" l 1-1/4" 1-1/2"

Up to 25 Ft. _ 25 to 100 Ft. 100 to 600 Ft.

Show 4 more labels / short text on this page
Foot Valve · Strainer · Screen · 2 _
Page 5 of the Sears 390.2508 user manual — Figure 4 - Removing Motor End Cover
Page 5 · click to enlarge
Page 5
Sears 390.2508 — ELECTRICAL diagram (page 5)
Fig. 4

ELECTRICAL

Disconnect power before working on pump, motor, pressure switch, or wiring.

Motor Switch Settings

Dial Type Voltage Selector

If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor.

Remove Hotor End Cover

Figure 5 - Voltage Set To 230 Volts, Dial Type

To change to I 15 volts: 1. Make sure power is off.

2. Turn the dial counter-clockwise until 115 shows in the dial window.

Figure 4 - Removing Motor End Cover

3. Reinstall the Motor end cover
4. Go to Wiring Connections, Page 6.

You will need to remove the motor end cover to change the voltage setting. The illustration above also shows the pressure switch. If the power supply connection still needs to be made, the pressure svdtch cover v/ill need to be removed.

I_,WARNING] Hazardous voltage. Can shock, burn, or kill. Connect ground wire before connecting power supply wires. Use the wire size (including the ground wire) specified in the wiring chart. If possible, connect the pump to a separate branch circuit with no other appli- ances on it.

Your motor terminal board (located under the motor end cover) should look like the one at right.

[_.WARNING] Explosion hazard. Do not ground to a gas supply line.

Page 6 of the Sears 390.2508 user manual — Figure 6 - Pressure switch wiring
Page 6 · click to enlarge
Page 6
Sears 390.2508 — WIRING CONNECTIONS diagram (page 6)
Fig. 5

ELECTRICAL

WIRING CONNECTIONS

Connection Procedure:

,AWARNING] Fire hazard. Incorrect voltage can cause a

1. Connect the ground wire first as shown in Figure 6. The ground wire must be a solid copper wire at least as large as the power supply wires.

fire or seriously damage the motor and voids the warranty. The supply voltage must be within + 10% of the motor name- plate voltage.

2. There must be a solid metal connection between the pressure switch and the motor for motor grounding protection. If the pressure switch is not connected to the motor, connect the green ground screw in the switch to the green ground screw under the motor end cover. Use a solid copper wire at least as large as the power supply wires.

Install, ground, wire, and maintain your pump in compli- ance with 'the National Electrical Code (NEC) or the Canadian Electrical Code (CEC), as applicable, and with all local codes and ordinances that apply. Consult your local building inspector for code information.

Connect the ground wire to a grounded lead in a service panel, to a metal underground water pipe, to a metal well casing at least ten feet (3M) long, or to a ground electrode provided by the power company or the hydro authority.

Motor wires connect here.

Connect the power supply wires to the pressure switch as shown in Figure 6.

-Power supply wires connect here.

230 Volt: Connect 2 hot wires (black and red) here and cap the white (neutral) wire. It does not matter which wire goes to which screw 115 Volt: Connect one hot wire (black or red) to one of these screws (it'doesn'tmatter which one). Connect the white (neutral)wire to the otherscrew. Cap any remaining

Reinstall the pressure switch cover.

black or red wires,

prevent strain on the terminal screws.

green (or bare copper) ground wire to the green ground screw. 31870398

Figure 6 - Pressure switch wiring

TABLE Ih WIRING CHART - Recommended Fusing and Wiring Data

Distance in Feet From Motor to Meter

Branch* Motor Max. Fuse Horse- Load Rating power Volts Amperes Amps

0' 51' 101' 201' 201' 401' to 50' 100' 200' 300' 400' 500' Wire Size 10/14! 8/t416/1416/12

1/2 115/230 10.4/5.2 15/15 14/14 r 14/14 {

  • Time delayed fuses are recommended instead of regularfuses in any motor circuit.
Page 7 of the Sears 390.2508 user manual — Draining for Winter
Page 7 · click to enlarge
Page 7
Sears 390.2508 — Priming the Pump diagram (page 7)
Fig. 6 · Priming the Pump

Priming the Pump

Disassembly and Assembly of Pump

&WARNING Risk of electrical shock. Be sure Unit is grounded and power disconnected before at- tempting any work on pump or motor.

[& CAUTION Never run pump dry. Running pump with- out water may cause pump to overheat, dam- aging seal and possibly causing burns to persons handling pump. Fill pump with water before starting.

Your SEARS pump is designed for ease in servicing. Should repair or replacement of the motor or seal be needed, the pump and piping do not need to be disconnected or dis- turbed.

l. Disassemble ptmap as follows:

_WARNING Explosion Hazard. Never run pump against closed discharge. To do so can boil water in- side pump, causing hazardous pressure ha unit, risk of ex- plosion and possibly scalding persons handling pump.

A. Disconnect power.

B. Remove pressure switch tube from pump body and allow pump to drain.

To prevent damage to internal parts, do not start motor until pump has been filled with water.

C. Remove four hexnuts and lockwashers (Key Nos. 24 and 23, Page 12) which hold the pump body to the motor.

To prime pump:

D. Remove motor, seal plate, impeller, rubber pad and diffuser (Key Nos. 1, 3, 7, 8 and 9, Page 12) as a unit. You may have to pry gently with two screwdrivers be- tween the motor flange and the pump body to sepa- rate pump and motor.

1. Remove priming plug (Figure 1, Page 3).
2. Fill pump with water.
3. Replace priming plug, using Teflon tape on plug threads; tighten plug.
4. Start the pump. Water should be pumped in 1-2 minutes. If not, repeat steps 1, 2 and 3.
2. Reassembly of pump:

A. install O-Ring gasket on seal plate (Key Nos. 5 and 3, Page 12).

On shallow depths to water (ten feet or less), the pump vdIl more than likely prime the first time after following the outlined procedure.

B. Pick up a small amount of petroleum jelly on one fin- ger and spread evenly over seal plate and venturi O-Ring gasket for lubrication during reassembly. Be careful not to nick or tear O-Ring.

From ten to 20 foot depths, it is very likely you v_ill have to shut the pump off and reptime per the outlined pro- cedure several times.

C. Replace motor onto pump body; be sure rubber pad (Key No. 8, Page 12) stays in place on top of diffuser. Remount base on lower studs. Tighten four hexnuts and lockwashers snugly (35_15 inch-lbs, torque). Do not overtighten.

5. If, after priming pump several times, no water is pumped, check the following:

A. Be sure suction pipe is in the water.

B. Be sure suction pipe has no leaks.

D. Replace pressure switch tubing and motor wiring.

C. Be sure the pump is not trying to lift water too high. (See "Piping in the Well," Page 4).

E. Prime pump according to instructions above. F. Check for leaks.

6. As long as foot valve and check valve function correctly and suction pipe does not develop leaks, pump should not need repriming in normal service.

Removing Motor for Service and Replacing Shaft Seal

MAINTAINING YOUR PUMP

If it is necessary to separate motor and seal plate, always re- place the shaft seal. We suggest you purchase this item, U109_A, and have it on hand for future use.

Lubrication

It is not necessary to lubricate the pump or its motor. The motor bearings are lubricated for life. The mechanical shaft seal in the pump is water lubricated and self-adjusting.

Remove motor as follows:

Draining for Winter

l. Disassemble pump per instructions above.

When the pump is to be disconnected from service or is in danger of freezing, it must be drained. To drain it, turn off power and relieve all pressure on the system. Remove pres- sure switch tubing from the side of the pump housing. Remove the priming plug to vent the pump. Drain the pres- sure tank; drain all piping to a point below the freeze line.

2. Remove diffuser and impeller as follows (Key Nos. 9 and 7, Page 12).

A. Remove screws holding diffuser.

B. Loosen two screws aiad remove motor canopy from motor (Key No. 1, Page 12).

To drain an air volume control (AVC), remove the tubing from it and turn the AVC upside down. This will permit any water in the AVC to drain into tank.

C. Place 7/16" open end wrench on motor shaft flat.

D. Turn impeller counterclockwise when facing it.

Page 8 of the Sears 390.2508 user manual — Table of Contents
Page 8 · Contents
Contents

Contents

SEARSp.1OWNER'Sp.1MANUALp.1390.2508p.1CRAFTSMAN ° HYDROGLASS ® SHALLOW WELL JET PUMPp.1CAUTION:p.1Read andFollow All Safety Rulesandp.1GENERAL INFORMATIONp.3Table h Pump Performance Chart (In Gallons Per Minute)p.3MAJOR COMPONENTS AND WHAT THEY DOp.3PIPINGp.3Piping in the Wellp.323140E96p.3Figure Ip.3Pressure Switchp.3Couplin9 Not Orive to Point Scalep.3MODEL NO. PUMP STARTS AT [PUMP STOPS AT 390.2508 _ / _p.3Check Valve or Foot Valvep.3PIPING INSTALLATIONp.4Cased Open Well Waterp.41-1/2"p.4Discharge Pipe Sizesp.4ELECTRICALp.5Motor Switch Settingsp.5Dial Type Voltage Selectorp.5Remove Hotor End Coverp.5Figure 5 - Voltage Set To 230 Volts, Dial Typep.5Figure 4 - Removing Motor End Coverp.5WIRING CONNECTIONSp.6Figure 6 - Pressure switch wiringp.6TABLE Ih WIRING CHART - Recommended Fusing and Wiring Datap.6Priming the Pumpp.7Disassembly and Assembly of Pumpp.7Removing Motor for Service and Replacing Shaft Sealp.7MAINTAINING YOUR PUMPp.7Lubricationp.7Draining for Winterp.7CARDBOARDWASHERp.8MOTOR FLANGE SCREWDRIVERp.8D WITHSEALp.8HALFp.8PUMPBACKp.8MOTORp.8_CREWDRIVERp.8TOP OF MOTOR FLANGEp.8COPPER SEATp.8SEAL PLATE INDEX PINS SLIDE IN HERE Figure I OAp.8FLOATINGp.8SEATp.8MEMBERp.8MOTOR FLANGEp.8SEAL PLATEp.8INDEX PINSp.8Figure I OBp.8SEAL PLATE HOLES MUSTp.9LINE UPp.9DIFFUSERp.9FACE OF SEALING WASHERp.9IMPELLER HUBp.9SHAFT SHOULDERp.9% BE SURE NIBS ENGAGE NOTCHESp.9RUBBER DRIVE RINGp.9Installing Copper Insertp.9Figure I Ip.9TO DISASSEMBLEp.9BE SURE RUBBER PAD STAYS IN PLACE ONp.9BESURESCREW ENGAGES HOLE IN SEALPLATEp.9RIB AT E O'CLOCKp.9PRIMING HOLEp.9Cleaning Shallow Well Jetp.10HELPFUL HINTSp.10How to Handle a Gaseous Wellp.10Remove /_ pUr=U'p.10Not pipep.10to valvo Scalep.10Figure I 7p.10Cleaning Impellerp.10Air Control in Flowing Wellsp.10TROUBLESHOOTING CHARTp.11SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTIONp.11
Page 9 of the Sears 390.2508 user manual — RIB AT E O'CLOCK
Page 9 · click to enlarge
Page 9
Sears 390.2508 — SEAL PLATE HOLES MUST diagram (page 9)
Fig. 7

I. Screw impeller on shaft (clockwise) while holding shaft wzth 7/16" open end wrench on shaft flats. This v_fll automatically locate seal in place. See Figure 11.

SEAL PLATE HOLES MUST

LINE UP

DIFFUSER

FACE OF SEALING WASHER

IMPELLER HUB

SHAFT SHOULDER

% BE SURE NIBS ENGAGE NOTCHES

RUBBER DRIVE RING

Installing Copper Insert

Figure I I

Remount diffuser on seal plate. Be sure diffuser is right side up as follows (see Figures 13 and 14).

1. Remove copper insert as shown in Figure 14. do not deform.

a. Rib next to priming hole should be at six o'clock position;

b. Part number (N1-28P) should be between nine o'clock and ten o'clock.

c. Both mounting screws must engage screw holes in seal plate. See Figure 12.

d. Be sure rubber pad (Figure 12; Key No. 8, Page 12) stays in place on top of diffuser.

TO DISASSEMBLE

BE SURE RUBBER PAD STAYS IN PLACE ON

BESURESCREW ENGAGES HOLE IN SEALPLATE

2. Replace copper insert:

A. Clean off surplus Permatex* from around insert cav- ity. Be careful not to scratch or mark the machined bore. It is important that this area be clean no no old Permatex lodges behind the new insert and causes im- proper seating.

MOLDED PART NO.

AT 9:30 BE SURE SCREW O'CLOCK ENGAGES HOLE IN SEAL PLATE

RIB AT E O'CLOCK

PRIMING HOLE

* "Permatex" is a registered trademark of Permatex Co. Inc.

Page 10 of the Sears 390.2508 user manual — Air Control in Flowing Wells
Page 10 · click to enlarge
Page 10
Sears 390.2508 — Cleaning Shallow Well Jet diagram (page 10)
Fig. 8 · Cleaning Shallow Well Jet

B. Place a small amount of No. 2 non-hardening Permatex on surface of insert as shown. Smooth out with finger. See Figure 15.

Cleaning Shallow Well Jet

To remove debris from venturi or nozzle, proceed as follows:

1. Disassemble pump per instructions on Page 7.
2. Turn venturi counterclockwise and remove it. The nozzle is now exposed. Remove it using a 5/8" hex socket wrench with extension. Turn counterclockwise. If socket wrench is not available, insert an ice pick or similar pointed tool carefully into the nozzle. This will dislodge debris.

Wipe on small amount of

non-hardening Permatex on this surface

3. Flush out the debris by running water through the nozzle in the same direction as the dislodging tool was inserted.
4. Replace nozzle and venturi. Do not overtighten!

C. Pull insert into cavity as shown in Figure 16.

5. Reassemble per pump instructions on Page 7.

HELPFUL HINTS

How to Handle a Gaseous Well

In some areas well water contains gases which must be at- lowed to escape before the water is used. This can be done as shown in Figure 18.

D. Clean out any surplus Permatex from insert cavity where new seal will be located. See Figure 17.

Remove /_ pUr=U'

Not pipe

to valvo Scale

A good way of delivering gas-free water is to suspend a pipe, closed at the bottom and open at the top, surrounding the suction pipe. Since the gases rise in the well casing, the water sucked down through the pipe and into the suction pipe is free of gas. This type of well must be vented to the outside of any enclosure.

Figure I 7

Cleaning Impeller

1. Follow steps 1A through 1D under "Disassembly and Assembly of Pump" on Page 7.

Air Control in Flowing Wells

2. Remove diffuser and impeller from pump per instructions under "Removing Motor for Service and Replacing Shaft Seal" on Page 7.

Flowing wells, or wells with little or no drawdown, could create a special problem in air control in the operation of your water system.

3. Clean impeller and reassemble impeller and diffuser per instructions under "Removing Motor for Serivce and Replacing Shaft Seal" on Page 7.

In such cases, install a Captive Air* Tank. It does not require any air control.

Show 8 more labels / short text on this page
Socket · Gases · rise to · $u_ace · wimtohold pipe slBeve · cap · ProperlyJ · Seated "
Page 11 of the Sears 390.2508 user manual — SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Page 11 · click to enlarge
Page 11
Sears 390.2508 — TROUBLESHOOTING CHART diagram (page 11)
Fig. 9

TROUBLESHOOTING CHART

SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION

Motor will not run 1. Disconnect switch is off 1. Be sure switch is on

2. Fuse is blown 2. Replace false
3. Starting switch is defective 3. Replace sta_ing switch
4. Wires at motor are loose, 4. Refer to instructions on wiring. Check and tighten all wiring. disconnected, or wired incorrectly
5. Pressure switch contacts are dirty 5. Cleanbyslidingpiecesofplainpaperbctweencontacts

Motor runs hot and 1. Motor is wired incorrectly 1. Refer to instructions on wiring

overload kicks off 2. Voltage is too low 2. Check with power company. Install heavier wiring if wire size is too small. See wiring instructions

3. Pump cycles too frequently 3. See section below on too frequent cycling

Motor runs but no I. 1, In new instalJation: water is delivered

Pump in new installation did not pick up prime through: a, Improper prinling b. Air leaks

a. Re-prime according to instructions b. Check all connections on suction line, air volume control, and jet c. Replace foot valve

c. Leaking foot valve

Pump has lost prime througha. Air leaks
2. In installation already in use: a. Check all connections on suction line, air volume control,

jet and shaft seal b. Lower suction line intu water and re-prime. If recedirtg water level in well exceeds suction lift, a deep well pump is needed

b. Water level below suction

3. Jet or impeller is plugged

3, Clean jet or impeller according to instructions •

4. Check valve or foot valve is stuck in cinsed position
4. Replace check valve or foot valve
5. Pipes are frozen
5. Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
6. Foot valve and/or strainer are buried in sand or mud
6. Raise foot valve and/or strainer above well bottom
1. Water level in well is lower than estimated

Pump does not deliver water to full

1. A deep weIl jet pump may be needed (over 20 ft. to water)

capacity (Also check point 3

2. Steel piping (if used) is corroded or limed, causing excess friction
2. Replace with plastic pipe where possible, otherwise with new steel pipe

3, Offset piping is too small in size

3. Use larger offset piping

Pump pumps water but does not shut off

I, Pressure switch is out of adjustment or contacts are "frozen"

1. Adjust or replace pressure switch
2. Faucets have been left open
2. Close faucets
3. Jet or impeller is clogged
3. Clean jet or impeller
4. Water level in well is lower than estimated
4. Check possibility of using a deep well jet pump
5. Motor is wired incorrectly
5. Refer to instructions on wiring

Pump cycles too frequently

1. Standard pressure tank is waterlogged and has no air cushion
1. Drain tank to air volume control tapping. Check air volume control for defects. Check for air leaks at any connection
2. Pipe leak
2. Check connections
3. Faucets or valves are open
3. Close faucets or valves
4. Foot valve leaks
4. Replace foot valve
5. Pressure switch is out of adjustment
5. Replace pressure switch
6. Air charge too low in Captive Air* Tank
6. Disconnect electrical power and open faucets until all pressure is relieved. Using automobile tire pressure gauge, check air pressure in tank at the valve stem located at top of tank. If air pressure is lower, pump air into tank from outside source undi proper air pressure is reached. Check air valve for leaks, oKmg soapy solution, and replace core If necessary.

Air spurts from faucets 3

1. Pump is picking up prime
1. As soon as pump picks up prime, all air will be ejected

o2. Leak in suction side of pump

2. Check suction piping
3. Well is gaseous
3. Change installation as described in manual
4. lr_termlttent over-pumping of well
4. Lower foot valve if possible, otherwise restrict discharge side of pump

of pump · immediately above)

Page 12 of the Sears 390.2508 user manual — Sears Product Service, 1-800-366-7278
Page 12 · click to enlarge
Page 12
Sears 390.2508 — TROUBLESHOOTING CHART diagram (page 12)
Fig. 10

REPAIR PARTS

6 7 8 9

To Order Parts, Call

Sears Product Service, 1-800-366-7278

J 14

13 / 12 J 12A / 12B

Model 390.2508

Key Qty. No, Part Number Used Description

1# J218-g53c 1 Motor - 115/230V 2 17351-0009 1 Water Slinger 3* N203-12P 1 Sea_ Plate Assembly 4 J3-2 1 Seal Plate Insert

5 U9-390 1 O-Ring 6 U109-6A 1 Shaft Seal 7 J105-40PF 1 Impeller 8 C35-41 1 Rubber Pad 9 N1-28P 1 Diffuser

10 U30-738SS 2 Capscrew #10-16 Hex Head 11** N176-35PE 1 Pump Body Assembly 12 N76-38PE 1 Pump Body 12A U9-226 1 O-Ring 12B N166-5P 1 Check Valve

131" 1 Pipe Plug 1/8" NPT 14 U111-212T 2 90 ° Hose Barb 15 U37-669P 1 Switch Tube 16 J20-18 1 Gasket 17 N76-29P 1 Pump Body Jet Insert 18 U30-742SS 4 Capscrew #10-16 19 N34P-19 1 Nozzre #45 20 N32P-66 1 Venturi

21 U9-201 1 O-Ring 22 J104-gP t Base Assembly Painted 23t 4 Lock Washer 3/8" 24t 4 Nut 3/8" - 16 25 C35-5 1 Rubber Pad 26 2781 1 Pressure switch 271" 1 Locknut 1/2" 28 L43-5C 1 Connector 1/2"

# For repair or service to motors, always give the meter model number and any other data found on the motor model plate. • Includes Key Nos. 4 and 5. ** Includes Key Nos. 12, 12A, 12B, and 16 through 21, t Standard hardware item, may be purchased locally.

AVC Port · 2305 0296

Page 13 of the Sears 390.2508 user manual — TROUBLESHOOTING CHART
Page 13 · click to enlarge
Page 13
Sears 390.2508 — TROUBLESHOOTING CHART diagram (page 13)
Fig. 11
Page 14 of the Sears 390.2508 user manual — TROUBLESHOOTING CHART
Page 14 · click to enlarge
Page 14
Sears 390.2508 — TROUBLESHOOTING CHART diagram (page 14)
Fig. 12
Page 15 of the Sears 390.2508 user manual — TROUBLESHOOTING CHART
Page 15 · click to enlarge
Page 15
Sears 390.2508 — TROUBLESHOOTING CHART diagram (page 15)
Fig. 13
Page 16 of the Sears 390.2508 user manual — information:
Page 16 · click to enlarge
Page 16
Sears 390.2508 — TROUBLESHOOTING CHART diagram (page 16)
Fig. 14

SEARS

I:RRFTSMRN* HYDROGLASS ® SHALLOW WELL JET PUMP

OWNER'S

MANUAL

Forthe repairor replacementpartsyouneed

Call 7am - 7 prn, 7 daysa week 1-800-366-PART (1-800-366-7278)

MODEL NO.

390.2508

Forin-homemajorbrand repair service

Call24 hours aday,7 daysa week

1-800-4-REPAIR (1-800-478-7247)

The model number of

your Shallow Well Jet

Forthe locationof a SearsRepairServiceCenterinyourarea

Pumpwill be found on a plate attached to the pump discharge connection.

Call 24 hours a day,7 daysaweek

1-800-488-1222

For informationonpurchasinga Sears

When requesting service or ordering parts, always give the following

MaintenanceAgreementorto inquire

aboutan existingAgreement call 9 am - 5 pm, Monday-Saturday

1-800-827-6655 SEARS

information:

  • ProductType
  • Model Number
  • Part Number

Ame#ca 's Repair Specialists

  • Part Description

Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.

Ask about the Sears 390.2508

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Sears 390.2508

Be the first to ask — other owners or our team will answer.