MCC4R, MCC8R, MCC16R
MCC8RD, MCC16RD
Raritan Computer Inc. 400 Cottontail Lane Somerset, NJ 08873 USA Tel. 1-732-764-8886 Fax. 1-732-764-8887 E-mail: sales@raritan.com http://www.raritan.com/
Raritan Computer Europe, B.V. Eglantierbaan 16 2908 LV Capelle aan den IJssel The Netherlands Tel. 31-10-284-4040 Fax. 31-10-284-4049 E-mail: sales.europe@raritan.com http://www.raritan.com/ Raritan Computer Japan, Inc. 4th Flr. Shinkawa NS Building 1-26-2 Shin-kawa, Chuo-ku Tokyo 104-0033 Japan Tel. 81-03-3523-5991 Fax. 81-03-3523-5992 E-mail: sales@raritan.co.jp http://www.raritan.co.jp
Raritan Computer Taiwan, Inc. 5F, 121, Lane 235, Pao-Chiao Rd., Hsin Tien Taipei Hsien Taiwan, ROC Tel. 886-2-8919-1333 Fax. 886-2-8919-1338 E-mail: sales.asia@raritan.com http://www.raritan.com.tw Raritan Computer France 120 Rue Jean Jaures 93200 Levallois-Perret France Tel. 33-14-756-2039 Fax. 33-14-756-2061 E-mail: sales.france@raritan.com http://www.raritan.fr
Raritan Computer Deutschland GmbH Lichstraße 2 D-45127 Essen Germany Tel. 49-201-747-9820 Fax. 49-201-747-9850 E-mail: sales.germany@raritan.com http://www.raritan.de Raritan Computer U.K. Ltd. 36 Great St. Helen's London EC3A 6AP United Kingdom Tel. 44 20 7614 7700 Fax. 44 20 7614 7701 E-mail: sales.uk@raritan.com http://www.raritan.com
Shanghai Representative Office of Raritan Computer, Inc. RM 19C-1 Shanghai Shiye Building 18 Caoxi North Road Shanghai China 2000030 Tel. 86-21-64680475 Fax. 86-21-64627964 E-mail: sales.asia@raritan.com http://www.raritan.com.tw/
C US L U 1F61 I.T.E.
Copyright ©2008 Raritan Computer, Inc.
MCC-0F-E
June 2008 · 255-80-3100



This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential environment may cause harmful interference.
Product names mentioned in this document are trademarks or registered trademarks of their respective companies. MasterConsole, and its respective logos are registered trademarks of Raritan Computer, Inc. PS/2, RS/6000, and PC/AT are registered trademarks of the International Business Machines Corporation. Mac is a registered trademark of Apple Computer, Inc. Sun is a registered trademark of Sun Microsystems. Alpha is a registered trademark of Digital Equipment Corporation. HP9000 is a registered trademark of Hewlett Packard. SGI is a registered trademark of Silicon Graphics, Inc.

For assistance in the U.S., please contact the Raritan Technical Support Team
at (732) 764-8886 or e-mail us at tech@raritan.com. Ask for Technical Support – Monday through Friday, 8:00am to 8:00pm, EST.
For assistance outside the U.S., please contact your regional Raritan office.
FCC Information · Trademark Information · Japanese Approvals

This page intentionally left blank.


MasterConsole II Configuration Diagrams 30
APPENDIX F: TROUBLESHOOTING ...................................................................................35




Chapter 1: Introduction
Raritan's keyboard/video/mouse (KVM) switches are engineered to provide reliable, cost-effective, central control of multiple computers. This eliminates the cost and clutter of unnecessary equipment, reclaims space, and improves productivity for a host of applications. MasterConsole II enables control of any mix of 2 to 256 computers from a single keyboard, monitor, and mouse. The MasterConsole II user interface provides simple on-screen control and system management. Raritan's unique emulation technology dedicates a keyboard/mouse emulator for each computer to ensure that each computer always 'sees' its own keyboard and mouse. This means smooth, flawless switching and operation, even when computers are running the most demanding operating systems.


Figure 1 MCC4 – Front and Rear Views

Figure 2 MC8 – Front and Rear Views
MasterConsole II Overview · Product Photos


Figure 3 MCC16 – Front and Rear Views
Product Features

Chapter 2: Installation
MasterConsole II is designed for quick, easy installation and operation. Follow the steps for either one-tier or two-tier configuration to be up and running within minutes: 1. Install MasterConsole II (connect computers). 2. Configure MasterConsole II. 3. Assign computer names and set channel-specific scan rates for attached computers. 4. Turn ON security and change passwords to restrict access to computers connected to MasterConsole II. 5. Operate using On-Screen User Interface or front panel buttons. 6. Install optional Cat5 Reach for remote console or satellite unit.
Quick-Start Operation:
After you connect computers to your MasterConsole II you may wish to explore MasterConsole II operation with the default names and parameters. You may operate using the front panel buttons and/or the On-Screen User Interface. To activate On-Screen User Interface, press the key twice rapidly. The Selection Menu will appear. To select a computer, use the (up arrow) / (down arrow) keys to highlight the desired channel (computer) and press or press the desired computer's Key number (located in the left-hand column). To select another computer, use front panel buttons or re- activate the On-Screen User Interface.
Getting Started

One-Tier and Two-Tier Configurations
MasterConsole II can be configured in one or two tiers, depending on the number of computers you want to control. In a one-tier configuration, only computers are connected to a single MasterConsole II unit. In a two-tier configuration, either a computer or another MasterConsole unit is connected to each channel of the base MasterConsole II unit.

Figure 4 One-Tier Configuration

Second Tier Second Tier
Cat 5 Remote KVM Model
Cat 5 Cable up to 650’
Figure 5 Two-Tier Configuration (with optional Remote Access)


Monitor Port Keyboard Port
Figure 6 MasterConsole II Rear Panel

Figure 7 One-Tier Configuration Cabling Detail
Installation · Mouse Port


Figure 8 Cable Adapters to Convert PS/2 to AT

Figure 9 MasterConsole II Front Panel

Figure 10 MasterConsole II Front Panel Channel Lights

The Configuration Menu is used to specify your MasterConsole II configuration and to set/change operation parameters. 1. Activate on-screen user interface by pressing the hot-key ( by default) twice rapidly. 2. Press to access the Configuration Menu.

Figure 11 Configuration Menu
a. The Connected field displays the Channel ID and Name of the currently selected computer. b. The Model field displays the model number of this MasterConsole unit. 3. Use the (forward)/ + (backward) keys to highlight the desired field and make your changes as follows:
a. To change Name (default is the unit’s model number): Move to Name and type a name up to five characters. This field is used for your identification purposes only.
b. The Device field specifies the type of device connected to each channel. The default character is ".", which indicates that the device is a computer. In a one-tier configuration, only a computer may be connected to each channel. The Device field settings may be changed when expanding to a two-tier configuration.
c. To turn AutoScan ON/OFF (default is OFF): Move to Scan and press the / keys to toggle. If you exit On-Screen User Interface with AutoScan ON, MasterConsole II will scan according to the currently set mode (Individual/Global) and scan rate.
To change the Global Scan Rate (default is 3 seconds): Move to Set and type a number from 01 to 99, or press the / keys to specify the Scan Rate (in seconds) for Global AutoScan.
To change AutoScan mode (default setting is Global): Move to Mode and press the / keys to toggle between Global and Individual. See page 34 for description.
d. To turn AutoSkip ON/OFF (default is OFF): Move to Skip and press the / keys to toggle. With AutoSkip ON, only active channels can be selected.
e. To change the ID Display time interval (default is 3 seconds): Move to ID Display and type a number from 01 to 99, or press the / keys to specify the interval (in seconds) you want the Channel ID and Name to display when each computer is selected. Type 99 if you want the Channel ID and Name to display continuously.
f. To change the On-Screen User Interface activator (default is ): Move to Hot Key and press the / keys to select the desired key. The hot-key can only be , , left or left .
g. To change the menu Display position: Move to Menu and press the key. Then press the , , , and keys to move the menu vertically and horizontally to the desired position. Then press or .
Configuration

h. To change the channel ID display position: Move to ID and press . Then press the , , , and keys to move the menu vertically and horizontally to the desired position. Then press or .
i. To turn PowerSave On/Off (default is OFF): Move to Green Mode and press the / keys to toggle. To change the PowerSave delay time (default is 15 minutes): Move to the next field and type a number from 01 to 99, or press the / keys to change the interval (in minutes) of inactivity (no keyboard or mouse operation) after which the video signal will be cut off from the monitor. This will allow a properly equipped monitor to enter low-energy mode.
j. To select Previous Channel Toggle (default is ). This feature enables the user to toggle between the previous and current selected channel. Press F4 to display the Configuration menu and move the cursor to the Previous Channel Key. Use the or keys to select the key, , , , left , or left to be used. This feature enables the user to switch back to a previous channel by pressing the selected key twice rapidly. There is no need to activate the OSUI.
Assigning Names and Scan Rates
You may assign meaningful names to quickly and easily identify and select connected computers. By default, the channel name is PC00aa (where aa is the channel ID number) and the Channel- Specific Scan Rate is 3 seconds. 1. Activate On-Screen User Interface. 2. Press to access the Edit Names and Scan Rate Menu.

Figure 12 Edit Names and Scan Rate Menu (One-Tier)
00 to 99 (seconds). When the AutoScan Mode in the Configuration Menu is set to Individual, these Channel-Specific Scan Rates are enabled. If the AutoScan mode is set to Global, the global value will be used. 4. When you move to a different page or exit this Menu, you are prompted to save your changes. Press to save. 5. To exit the Edit Names and Scan Rate Menu: Press any Menu F key to go to another menu, or press to go to the Selection Menu.

Using MasterConsole II Security Feature
You can restrict access to MasterConsole II. The Administration Menu is used to turn security on/OFF and to change the Administrator's Password and the five authorized user passwords. Up to six passwords can be defined - one Administration Password and five User Passwords.
Only the Administrator's password provides access to the Administration Menu, which is accessed to turn security on/off and to change passwords. If you use the security feature, be sure to record and store passwords where they will be handy to you and other authorized users. MasterConsole II is delivered with system default passwords. They are:
USER PASSWORD Admin Raritan User 1 111 User 2 222 User 3 333 User 4 444 User 5 555
Turning Security on/OFF and Changing Passwords:

Figure 13 Administration Menu
field, then type a number from 01 to 99, or use the / keys to specify a time
Passwords

interval. If the system will remains inactive (no keyboard or mouse operation) for this time interval, the next user is required to enter a password to access the MasterConsole II. c. To change the Administration Password: Move to Change Passwords, where Admin will be highlighted. Press the key and type a new password (up to eight alphanumeric characters, no spaces). Press . Confirm the password by typing it again. Press . d. To change a User Password, press the key to highlight one of the desired Users.
Press . Type a new password (up to eight alphanumeric characters, no spaces). Press . Confirm the password by typing it again. Press . Repeat this process for the remaining four Users, pressing the key to move from one User field to the next. You can specify up to five User Passwords. e. To change the type of keyboard, press the key to highlight Language Mode field. Press / to select English, German, or French. 6. To exit the Administration Menu: Press any Menu F (function #) key to go to another menu or press to exit on-screen user interface and return to normal computer operation.

Figure 14 Selection Menu (One-Tier, sorted by Channel ID)
in the first column indicates a device is connected and powered ON, while a "-" indicates the device is powered OFF or there is no device connected. "Snn" indicates the Channel- Specific Scan Rate of nn seconds. (default is 3 seconds). c. As the computer status changes (active/inactive), the MCC updates the Status column periodically. To enable a user to see the new status immediately, activate the OSUI and press F8-Upgrade Computer Status. The MCC will scan the channels and update the computer status and then return to the previous menu. d. For any inactive channel, the ID bar will display only the channel ID and not the name
field, when sorted by channel and will not display anything when sorted by name-F12 toggle. e. The non-displayed names are still available in the MCC internal database and can be edited with the F3 function.
Selecting a Computer

Use the / or / keys to highlight the desired computer and press OR
When the Selection Menu is sorted by Channel ID, press the desired computer's Key number (shown in the left-hand column); OR
When the Selection Menu is sorted by name (arranged alphabetically), use the / or / keys, or type the first character(s) of the desired Name to quickly jump to the Name that most closely matches what you type. To back up a character, press the key. Highlight the desired computer, and press . a. When you select a computer, you automatically return to normal computer operation at the selected computer. b. The light above the selected Channel button turns from amber to green, and the monitor
displays video from the selected computer. c. The Channel ID and Name will be displayed on the monitor for the time interval specified in the Configuration Menu. d. Press at any time to return to the first page of the Configuration Menu (for 16-
channel or two-tier systems).
AutoScan activation shortcut: Activate the On-Screen User Interface and press the Key. The green light next to the button on the front panel will be ON and the unit will scan according to the parameters set in the Configuration Menu.
When the on-screen user interface is not activated, you can operate MasterConsole II from the front panel. The front panel has a [Scan] button, a [Skip] button, and a series of numbered buttons used to select channels and to set the Global scan rate.
Figure 15 MasterConsole II Front Panel
Figure 16 MasterConsole II Front Panel Channel Lights
Setting AutoScan

c. The light above the selected Channel button turns green, video from the selected computer displays on screen and you may now operate the selected computer. d. The Channel ID and Name will be displayed on the screen for the time interval specified
in the Configuration Menu. 2. To activate AutoScan, press the [Scan] button (toggle ON/OFF) The green light next to the [Scan] button will be ON and the unit will scan according to the parameters set in the Configuration Menu. If the AutoScan Mode is set to Individual, AutoScan will occur at the Channel-Specific Scan Rates as defined in the Edit Names and Scan Rate Menu. 3. To change the scan rate, while AutoScan is ON, press the numbered button corresponding to the desired Scan Rate located above the front panel channel light to set the Global Scan Rate. If the Scan Mode in the Configuration Menu had been previously set to Individual, it will be reset to Global after the front panel button is pressed. 4. To activate AutoSkip, press the [Skip] button (toggle ON/OFF). The green light next to the [Skip] button will be ON and only active channels will be selected.

You may cascade MasterConsole II units to create a two-tier configuration. In a two-tier configuration, a mix of devices – computers and MasterConsoles – may be connected to the channels of the first tier-referred to as the base MasterConsole II. The second-tier MasterConsole may be any combination of MasterConsole IIs, or MasterConsole P Models, which may be banked. Only computers may be connected to the channels of the any second-tier MasterConsole.

Figure 17 Two-Tier Configuration (with optional Remote Access Kit)

Install Base Unit (First-Tier) MasterConsole II
Monitor Port Keyboard Port
Figure 18 MasterConsole II Rear Panel

Figure 19 Two-Tier Configuration Cabling Detail
numbered Channels on the base MasterConsole II back panel. c. Plug the cable's other connectors into the computer's keyboard, monitor, and mouse ports. Use supplied adapters for AT style PCs. d. Power ON the connected computer. e. Select the connected computer by pressing the corresponding front panel button. Verify that the monitor attached to MasterConsole II displays the video for the connected computer. Use the keyboard and mouse attached to the base MasterConsole II to verify that they operate the connected computer. f. Repeat steps 3.a through 3.e to connect additional computers to the base MasterConsole II.
Installation · Mouse Port

Connect Second-Tier MasterConsole(s) to the Base Unit
second-tier MasterConsole II or MasterConsole P Model. c. Power on the MasterConsole unit according to the following instructions:
Note: All second-tier MasterConsole P Models must be MasterView ready. To determine if your P Model does have this feature, check the white label on the bottom of the unit *. This label shows the unit's level and style of firmware: MDSP-nnn. If it is MDSP-1AC or higher (MDSP-1AD, etc.), the unit is MasterView ready. If not, you need to upgrade. Call Raritan Technical Support for details.
IMPORTANT: For MasterConsole II, the unit must be programmed as a second-tier unit. (The default setting is first-tier) To program any MasterConsole II as a second-tier unit, power ON while pressing the Channel #2 button on the front panel and hold for 3 seconds. When the unit is programmed as a second-tier unit, the LED on the far right of the unit's front panel (2ND) will be lit continuously. Note: Any unit can be re-programmed to be a first-tier unit by pressing the Channel #1 button on the front panel during a subsequent power ON process.
For MasterConsole P Model: Turn the power switch on. 1. Repeat steps 4a through 4c to connect additional second-tier MasterConsole units to the base MasterConsole II. 2. For second-tier units located more than 30 feet away from the base unit, see Remote Access Using Cat5 Reach, page 25.
Connect Computers to Second-Tier MasterConsole(s)
Connect computers to the channels of second-tier MasterConsole(s). 1. Follow Steps 3a through 3f to connect the computers to each second-tier MasterConsole II. 2. For MasterConsole P Models, follow installation instructions in the P Model manual.
The Configuration Menu is used to specify your base MasterConsole II configuration and to set/change parameters for operation. 1. Activate on-screen user interface by pressing the hot-key ( by default) twice rapidly. 2. Press to access the Configuration Menu.
Configuration


Figure 20 Configuration Menu (Two-Tier)
a. The Connected field displays the Channel ID and Name of the currently selected computer. b. The Model field displays the model number of this MasterConsole unit (MCCn). 3. Use the (forward)/ (backward) keys to select the desired field and make your change as follows: a. To change Name (default is the unit's model number): Move to Name and type a name up to five characters. This field is used for your identification purposes only. b. The Device field specifies the type of device computer or MasterConsole connected to
each channel of the base MasterConsole II unit. to the Device field. You must specify the device for each channel The Device field consists of a sequence of characters equal to the channel capacity of the base unit. The leftmost character corresponds to the unit's channel 1, while the rightmost character corresponds to the highest channel number.
.(dot) = computer (default) For non-computers, define the Device as follows: a = MCP2 b = MCP4 c = MCP8 d = MCP16 x = MCC4, MCS4, MCX4 y = MCC8, MCS8, MCX8 z = MCC16, MCX16
Figure 21 Device Types

Figure 22 Device Field
For example, the y c . . Device field indicates the following: an 8-channel MasterConsole II MCC8 model is connected to the first channel on the base MasterConsole II, an 8-channel MasterConsole P Model is connected to the sixth channel, and computers are connected (or to be connected) to all other channels.

See One-Tier Configuration for instructions on setting/changing other operational parameters (AutoScan, AutoSkip, ID Display, hot-key, Menu Display, PowerSave).

Assigning Names and Scan Rates
When you specify non-computer devices (MasterConsole units) connected to base MasterConsole II channels, these devices are automatically assigned default names in the base MasterConsole II Selection Menu. In addition, since computers can be connected to each channel of a second-tier MasterConsole, a page is automatically created for each second-tier MasterConsole in the Selection Menu, listing Channel IDs with default names for each channel. These names may be changed using the Edit Names and Scan Rate Menu. The following are the MasterConsole II default Channel ID and Names for connected devices in a two-tier configuration.

Figure 23 Default MasterConsole II Channel IDs and Names
To change Names and/or Channel-Specific Scan Rates: 1. Activate On-Screen User Interface. 2. Press to access the Edit Names and Scan Rate Menu.

Figure 24 Edit Names and Scan Rate Menu (Base MasterConole II)


Figure 25 Edit Names and Scan Rate Menu (Second-Tier MCC8)
a. To change the Name of a second tier MasterConsole Device in the base unit channel list: Type up to seven alphanumeric characters (no spaces). The "/" (backslash) first character cannot be changed. b. To change the Name of any computer connected to either the base unit or second-tier
MasterConsole, type up to eight alphanumeric characters (no spaces). c. To change the Channel-Specific scan Rate for any highlighted channel (default is 3 seconds): Type a number from 00 to 99 (in seconds). When the AutoScan Mode in the Configuration Menu is set to Individual, these Channel-Specific Scan Rates are enabled. If the AutoScan mode is set to Global, the global scan rate will be used. 4. When you move to a different page or exit this Menu, you are prompted to save your changes. Press to save. 5. To exit the Edit Names and Scan Rate Menu: Press any Menu F key to go to another menu, or press to go to the Selection Menu.

Using MasterConsole II Security Features
Follow instructions for Security in Using MasterConsole II’s Security Feature (One-Tier).

Figure 26 Selection Menu (Two-Tier, Base MasterConsole II)

Figure 27 Selection Menu (Two-Tier, Second Tier Unit)
“+”in the base unit's Selection Menu indicates the device is connected and powered ON, while a “–” indicates the device is powered OFF, or there is no device connected. A “.” in
Operating MasterConsole II · Selecting a Computer

the Status column of the second-tier Selection Menu indicates that the status of the computer is undetermined. Snn indicates the individual Scan Rate of nn seconds. c. As the computer status changes (active/inactive), the MCC updates the Status column periodically. To enable a user to see the new status immediately, activate the OSUI and press F8-Upgrade Computer Status. The MCC will scan the channels and update the computer status and then return to the previous menu. d. For any inactive channel, the ID bar will display only the channel ID and not the name
field, when sorted by channel and will not display anything when sorted by name-F12 toggle. e. The non-displayed names are still available in the MCC internal database and can be edited with the F3 function. 3. To select a computer:
Use the / or / keys to scroll to the desired computer and press OR
When the Selection Menu is sorted by Channel ID, press the desired computer's Key number (in the left-hand column) OR
a. When the Selection Menu is sorted by name, use the / or / keys, or type the first character(s) of the desired Name to quickly jump to a Name that most closely matches what you type. To back up a character, press the key. Highlight the desired computer, and press . b. When you select a computer, you automatically return to normal computer operation at
the selected computer. c. The light above the selected Channel button turns green, and the monitor displays video from the selected computer. d. The Channel ID and Name will display on the monitor for the time interval specified in the
Configuration Menu. e. Press at any time to return to the first channel on the first page of the Selection Menu. Press at any time to advance to the last channel on the last page of the Selection Menu.



Raritan's Cat5 Reach can be used to extend the user console up to 650 feet away. Please see the Cat5 Reach manual for installation procedure. The MasterConsole II with Cat5 Reach provides:

Figure 28 Remote Access with Cat5 Reach

Figure 29 Two-Tier Configuration with Satellite Unit



Appendix A: Specifications
MCC4 (4–channel model) 10.55”(W) x 9”(D) x 1.75”(H) 2.0 kg (4.5 lbs.) MCC8 (8–channel model) 15.4”(W) x 9”(D) x 1.75”(H) 2.8 kg (6.1 lbs.) MCC16 (16–channel model) 15.4”(W) x 9”(D) x 3.5”(H) 3.8 kg (8.4 lbs.) Power 115V/230V (Auto Sensing) 60 Hz / 50 Hz 0.2A/0.1A
MCC4R (4–channel model) 19”(W) x 9”(D) x 1.75”(H) 3.0 kg (6.66 lbs.) MCC8R (8–channel model) 19”(W) x 9”(D) x 1.75”(H) 3.77 kg (8.37 lbs.) MCC16R (16–channel model) 19”(W) x 9”(D) x 3.5”(H) 4.8 kg (10.66 lbs.) Power 115V/230V (Auto Sensing) 60 Hz / 50 Hz 0.2A/0.1A
Rackmount 48 Volt DC Model
MCC8RD (8–channel model) 19”(W) x 9”(D) x 1.75”(H) 2.97 kg (6.6 lbs.) MCC16RD (16–channel model) 19”(W) x 9”(D) x 3.5”(H) 4.52 kg (10.05 lbs.) Power 48Volt DC +/-0.3A 3W3 male connector Pin out A1 (G), A2 (-), A3 (+) Operating Temp. 0–50°C (32–122°F)
For each PS/2 Computer (VGA Video, PS/2 K/B, PS/2 Mouse) and AT Computer (VGA Video, AT K/B, Serial Mouse) Part No. Length Connectors CCPT06 2’ (0.6 M) DB25(M) to HD15(M), 2x mini-DIN6(M) CCPT20 6.5’ (2 M) DB25(M) to HD15(M), 2x mini-DIN6(M) CCPT40 13’ (3 M) DB25(M) to HD15(M), 2x mini-DIN6(M) CCPT60 20’ (6 M) DB25(M) to HD15(M), 2x mini-DIN6(M) CCPT90 30’ (9 M) DB25(M) to HD15(M), 2x mini-DIN6(M) Each Universal Cable Kit comes with 2 Adapters for AT keyboard and serial mouse: (1) DIN 6F to DIN 5M, and (1) DIN 6F to DB9F

RMCS4 (for 4–channel model) 19” Rack Mount Bracket – 1U RMCS8 (for 8–channel model) 19” Rack Mount Bracket – 1U RMCS16 (for 16–channel model) 19” Rack Mount Bracket – 2U PCE60 20’ (6 M) Extension Cable for Keyboard, Video, and Mouse PCE110 35’ (11 M) Extension Cable for Keyboard, Video, and Mouse
See Cat5 Reach Specification Sheet for complete details. UKVM (Dual Transmitter for Category 5 UTP cable) Dimensions 4.3" (W) x 3.6"(D) x 1.0" (H) 108mm (W) x 91mm (D) x 23mm (H) Weight 0.5 lbs (0.2 kg) Power No external power required User Port (local access) 6 pin k/b & mouse, HD15 Connection to PC/switch Cable kit CCPT06 or CCP10E required URKVM (Receiver for Category 5 UTP cable) Dimensions 4.3" (W) x 3.6"(D) x 1.0" (H) 108mm (W) x 91mm (D) x 23mm (H) Weight 0.5 lbs (0.2 kg) Power 6V DC input (Adapter included) User Port (remote access) 6 pin k/b & mouse, HD15
For highest quality video at distances greater than 200', Category 5 UTP Enhanced (350Mhz bandwidth) cable is recommended.

Accessories · Remote Access Kit

Administration Password raritan (case sensitive)
Channel-Specific Scan Rate 3 seconds
Device “.” (computer devices)
Global Scan Rate 3 seconds
Hot Key
ID Display Interval 3 seconds
MasterConsole II unit configuration First tier
PowerSave delay time (Green Mode) 15 minutes
Remote Time Out interval 3 seconds
Security activation delay time 15 minutes
Selection Menu sorting Channel ID
User password User 1-111



Use the following Function Keys while using On-Screen User Interface:
PRESS... WHEN YOU WANT TO... Go to the Help Menu; get a list of all the Function keys Go to the Selection Menu; view the list of channels or select a channel Go to the Edit Names and Scan Rate Menu; change channel Names or Individual Scan Rates Go to the Configuration Menu; change operating parameters (on-screen user interface, Menu position, ID position, Global / Individual Scanning, AutoScan OFF/ON, scan rate, AutoSkip OFF/ON, Hot Key, duration of ID display) Go to the Administration Menu; turn Security ON/OFF, change User Passwords Exit On-Screen User Interface and turn ON AutoScan + Exit On-Screen User Interface and turn OFF AutoScan Exit On-Screen User Interface and turn ON AutoSkip + Exit On-Screen User Interface and turn OFF AutoSkip Toggle Selection Menu sorting (by Name or Channel ID) Exit on-screen user interface and return to normal computer operation at the last channel selected. If SCAN is set ON, the system will AutoScan according to parameters set in the Configuration Menu



Programming MasterConsole II at Power Up
MasterConsole II Product Design Background and Considerations
Each MasterConsole II is programmed at the factory as a base tier unit. To modify the factory setting, a MasterConsole II unit can be programmed as a second-tier unit by holding down the #2 button on the front panel at power up for a minimum of 3 seconds.
Programming MasterConsole II

MasterConsole II Configuration Diagrams
Basic MasterConsole II One-Tier Configurations

Figure 30 Basic One-Tier Configurations
MasterConsole II Two-Tier Configuration with Remote Access Kit

Figure 31 One-Tier with Remote Access Kit

MasterConsole II Two-Tier Configuration

Figure 32 Two-Tier Configuration of up to 256 Computers
MasterConsole II Two-Tier Configuration with MasterConsole P Model

Figure 33 Two-Tier Configuration with MasterConsole P Model

MasterConsole II Two-Tier Configuration with Satellite Unit

Figure 34 Two-Tier Configuration with Satellite Unit

Appendix E: Glossary
T ERM D EFINITION
Administration Menu Used to restrict access to MasterConsole II; toggle Security ON/OFF and to change Administrator’s Password and up to five User Passwords.
Administration Password The only Password with access to the Administration Menu, through
the Administration password prompt.
AutoScan When activated, MasterConsole II automatically cycles through channels, displaying each computer’s video for a specified period.
AutoSkip When activated, channel selection is restricted to active channels.
Base Unit MasterConsole II unit to which devices (computers and / or other MasterConsoles) are connected in a two-tier configuration.
Channel The 25-pin connector by which a device is connected to MasterConsole II.
Active: A channel is active when a powered ON device is connected to it.
Inactive: A channel is inactive when there is no device connected to it, or if the connected device is powered OFF.
Channel ID The specific Channel number to which a device is connected.
Configuration One-Tier: Computers are connected to a single MasterConsole II unit.
Two-Tier: A mix of devices (computers and MasterConsole units) is connected to a base MasterConsole unit.
Configuration Menu Used to specify MasterConsole II configuration and operation parameters.
Device A computer or a MasterConsole unit connected to a MasterConsole II channel.
Device Field In the Configuration Menu, specifies the type of device connected to each channel of a base MasterConsole II unit.
Edit Names and Scan Rate Menu
Channel-Specific Scan Rates.
Green Mode A field in the Configuration Menu used to toggle the PowerSave feature ON/OFF.
Hot Key Used to activate On-Screen User Interface. (To activate On-Screen User Interface, press the hot-key twice rap
ID Display The display shown on the monitor to identify the currently selected channel Key Left-hand column in the Selection Menu; lists the key numbers (a sequence of numbers) for the channels listed on that page. To quickly select a channel, press its Key number when the Selection Menu is displayed. KVM Port The Keyboard, Monitor, and Mouse connectors on the back of the MasterConsole II unit. Menu An On-Screen User Interface display. Menu F Keys Function keys used to access On-Screen User Interface menus while On-Screen User Interface is activated. Mode Field in the Configuration Menu; can be set to either Global or Individual. See also Scan Rate. Name A user-assigned label (up to eight characters) for a device connected to a MasterConsole II channel.

TERM DEFINITION On-Screen User Interface (OSUI)
Series of Menus displayed on the monitor that can be used, through keystrokes, to operate MasterConsole II. All keystrokes are captured and interpreted as MasterConsole II commands. PowerSave Allows a properly equipped monitor to operate in low-energy mode. Remote Console Keyboard, monitor, and mouse plugged into the Remote access kit. Cat5 Remote KVM Module: Optional Remote Unit that connects to the MasterConsole II to provide additional access to connected computers up to 650' away using Cat5 UTP Cable. Cat5 Remote KVM Port: The Keyboard, Monitor, and Mouse ports on the back of the Cat5 Remote KVM Module unit. Satellite Unit Second-tier MasterConsole II located more than 30 feet from the base unit and connected through its Remote Access Kit. Scan Front panel button and On-Screen User Interface function used to activate AutoScan. Scan Rate The duration (in seconds) a channel’s computer is to remain displayed on the monitor when AutoScan is activated. Global Scan Rate: Scan rate is the same for all computers, if the Mode field in the Configuration Menu is set to Global. Channel-Specific (Individual) Scan Rate:: Scan rate specified for each computer during the Scan cycle, if the Mode field in the Configuration Menu is set to Individual. Channel-specific scan rates can be set in the Edit Names and Scan Rate Menu. Security When activated, and the system remains idle for a period of time, the next user must enter an authorized User Password to establish access. Selection Menu Used to select a computer. Sorting Order of the channels listed in Selection Menu; either by Channel ID or by Name. Time Out the length of time that the system can remain idle (that is, since the last keyboard/mouse or front panel operation) before the next user must enter an authorized User Password to establish access. User Password Enables access to the system after Time Out.

PROBLEM SOLUTION No power. a. Check power cord. b. Make sure power switch is turned ON. c. Check cable connection from PC to MasterConsole II. No video display for one or all computers.
a. Check video cable’s connection to the PC. b. Check the monitor and PC: Turn off power to MasterConsole and the PCs. Connect the monitor to the PC directly, boot the PC, and make sure the monitor has the proper display. If it does not, the problem is either with your PC, or the monitor is not compatible with your PC. If it does display, continue to Troubleshooting #3. The monitor cannot correctly display the video output from some of the PCs.
a. The monitor probably does not match the video outputs. If the monitor is a single mode type VGA, all PCs must have the same type of video output. b. (Note: this problem occurs most often with some IBM PS/2s and IBM 63xx, 85xx, and 95xx monitors.) The intelligent type display card outputs video signals based on the monitor ID-pin setting in the connector of the monitor cable. If the ID-pin setting is correct, the monitor at MasterConsole may have no display, become monochrome instead of color, or become unstable. If this is the case, you will need to provide a proper ID-pattern to the display card. Call Raritan Computer for help if necessary. All PCs powered up without keyboard error, but the keyboard at MasterConsole II has no control (cannot input to any PC).
a. Make sure the keyboard is connected firmly into MasterConsole II. Disconnect and reconnect keyboard. b. Replace keyboard. (MasterConsole II allows hot re-connection of keyboard at its Keyboard port.) c. In a two-tier configuration, check that the MasterConsole II with the keyboard connected is the base unit. Repeated “KB ERROR" at power-up of PC.
a. The keyboard cable from the PC to MasterConsole II is loose. Secure the connection and power up the PC again. b. If the problem occurs after MasterConsole II has been installed for a period of time, and occurs on PCs that have previously worked with MasterConsole II , then some components are out of order. Verify that the PC works with the keyboard when connected directly. Then contact your dealer or Raritan Computer for service. After a period of trouble- free operation, the keyboard attached to MasterConsole II locks (unable to input keystrokes) when a particular PC is selected, but works normally when other PCs are selected.
a. The most likely cause of the problem is either a voltage "spike" (increase) or a "brown out" (decrease) in the power supply, which would cause the microprocessors in MasterConsole II to malfunction. A short-term solution to the problem is to try to recover operation by turning the MasterConsole II power switch off and on. Then, if necessary, restart all PCs. The long-term method of avoiding this problem is to power MasterConsole from a UPS. b. Check keyboard connection.
Repeated "MOUSE INSTALLATION FAILURE" at power-up of PC.
a. The mouse cable from the PC to MasterConsole II is loose. Secure the connection and power up again. b. If the problem only occurs to new PCs which are being added to the system, the firmware in the KVM (MasterConsole II internal mouse emulator) may need to be upgraded to a later version to be compatible with newer PCs. Contact your dealer or Raritan Computer for Service. After a period of trouble- free operation, the mouse attached to
a. Try to identify if the problem is originating from the PC by reconnecting the PC to a different channel with a different cable. Then power up the PC. If the problem is not with the cable or with the

PROBLEM SOLUTION MasterConsole II locks (unable to control mouse functions) when a particular PC is selected, but works normally when other PCs are selected.
specific channel, then connect the mouse directly to the PC. If the problem persists, then the PC's mouse port is out of order. Otherwise, contact your dealer or Raritan Computer. b. If the problem occurs after MasterConsole II has been installed for a period of time, and occurs to PCs that have previously worked with MasterConsole II, then some components are out of order. Contact your dealer or Raritan Computer for service. Unit does not operate in On-Screen User Interface.
Replace keyboard. On-Screen User Interface works only with PS/2 or extended AT style keyboards.
Unable to select channel.
Scan function is active; press the Scan button once to toggle Scan OFF so the light next to the button is off.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.