All safety information must be followed as provided in Service Manual of DV338, DV448, DV438.
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.


To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
An occurrence of an Error will make a sound of error melody for 5sec and con tinuously show one of the Error Displays from the following errors.

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
Continuous Run Mode: 1. Press Signal + Dry Level for 3 sec during Power On State (Normal User Mode) . 2. Once in Continuous Run Mode, 7-Segment will toggle display “total cycle” and the remain- ing time. 3. The previous cycle will restart during Continuous Run Mode until continuous run mode is disabled. 4. During Continuous Run Mode, press Signal + Dryness Level for 3 seconds to return to normal user mode. 7-segment will no long display “total cycle ” and only display the remaining time.
Definition of Special Test Mode: - Dryer must be on before Service Mode can be entered. - Press Signal and Temp Keys for 3 seconds, or until 3 beeps are heard. - The machine will now be in Service Mode. - Upon entry into Service Mode, the Sensor Bar Touch Data will be shown (Default Special Test Mode).
How to Enter: - To enter Special Test Mode press Signal and Temp Keys for 3 seconds for 3 seconds or until the control beep.
Special Test Mode ·

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
Sensor Bar Touch Data Mode
Definition of Sensor Bar Touch Data Mode: - While in Power On pressing Signal and Temp Keys for 3 seconds - This action will put the dryer into sensor bar touch data mode - Dryer will display Sensor Bar data. This mode is default mode of entering service mode
Definition of Cycle Count Mode: - While in Service Mode pressing the Signal key will put the dryer into the cycle count mode - Cycle number executed will display.
How to Enter: - To enter Special Test Mode press While in Service Mode pressing the Signal key for 3 seconds or until the control beep.
Definition of Software Version Mode: - While in Service Mode pressing the Temp key will put the dryer into the software version mode
How to Enter: - To enter Special Test Mode press Temp Key until the control beep. ex) In case of “U105”, U0 means major version “v1“ 05 means minor version “05”
Special Test Mode: - While in Power Off, pressing the Dryness Level + Power keys simultaneously will put the dryer into the System Check mode - “ t2 “ will display. - System Check Mode Progress t2 mode Function Performed Start/Pause Motor(CW) Relay On → Heater Relay On → Heater Relay Off → Motor(CW) Relay Off (Circulation)

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
TROUBLE DIAGNOSIS - As the micom dry machine is configured of the complicate structure, there might be the service call. Below information is prepared for exact trouble diagnosis and suitable repair guide.
Please follow below instruction for the trouble diagnosis and parts replacement.

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.




2.88Ω between Pin# 3 and 4

3.5Ω between Pin# 4 and 5
Contacts · Centrifugal Switch (Motor) ·

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.


Gas Valve(25M01A) Valve 1-2 : Resistance value 1.2K Ω Valve 1-3 : Resistance value 0.5K Ω Valve 4-5 : Resistance value 1.2K Ω If resistance is infinity, replace Valve
Radiant Sensor(10RS) Resistance value < 1 Ω If resistance is infinite, replace Radiant sensor


Igniter(101D) Resistance value 40~400 Ω If resistance is infinite, replace Igniter
Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 Ω If resistance is infinity, replace Thermostat

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.




CN1 1. AC Power Port 2. AC Power Off Detection Sensor 3. Door Detection Sensor
RY5 - Motor Relay Switch
RY6 - Heater Relay Switch

Sensor Bars - Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5. Approx ∞ Ω without laundry Approx 190Ω ± 10% with wet clothes
Cycling Thermostat - Disconnect harness and test Blue wire Pin 2 to Red wire Pin 6. Approx 10 KΩ at 25 °C/77 °F

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
3-WIRE SYSTEM CONNECTIONS 1. Loosen or remove center terminal block screw. 2. Connect neutral wire (white or center wire) of the power cord to the center, silver-colored terminal screw of the terminal block. Tighten screw. 3. Connect the other wires to outer terminal block screws. Tighten screws. 4. Tighten strain relief screws. 5. Insert tab of terminal block cover into your dryer’s rear panel slot. Secure cover with hold-down screw. 1. External ground connector 2. Neutral grounding wire (green/yellow) 3. Center silver-colored terminal block screw 4. Neutral wire (white or center wire) 5. 3/4” (1.9 cm) UL-listed strain relief
4-WIRE SYSTEM CONNECTIONS 1. Remove center terminal block screw. 2. Connect ground wire (green or unwrapped) of power cord to external ground conductor screw. 3. Connect neutral wire (white or center wire) of power cord and appliance ground wire (green with yellow stripes) under central screw of the terminal block. 4. Connect the other wires to outer terminal block screws. Tighten screws. 5. Tighten strain relief screws. 6. Insert tab of terminal block cover into your dryer’s rear panel slot. Secure cover with hold-down screw. 1. External ground connector 2. Green or bare copper wire of power cord 3. 3/4 in. (1.9 cm) UL-listed strain relief 4. Center silver-colored terminal block screw 5. Grounding wire (green/yellow) 6. Neutral wire (white or center wire)


To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Will Not Start or Run | • All wires are hooked up to their corresponding terminals. • Dryer is plugged in. • Blown fuse or circuit breaker. • Door switch functional...door closed. Check for error code 3 (See Table for codedefinition). • Start/Pause rotary selector dial functional. • Control Board operational. • Belt off or broken and Belt Cut-off Switch operates. • Drive motor functional. • Check motor winding resistance: 2.88ohms between pin #3 and 4, 3.5ohms between pin #4 and 5. | p.6 | |
| Motor runs/ tumbler will not turn | • Belt off or broken/damaged. • Idler tension spring too weak or stretched. • Idler pulley jammed or stuck. | p.6 | |
| Runs a few minutes and then stops | • Lint buildup around drive motor. • Low voltage present. • Blower impeller blocked in blower housing. • Drive motor - start switch contacts stuck closed. | p.6 | |
| Blows fuses or trips circuit breaker | - Is the belt connected well? - Is the winding of the motor continuous? (Rotor winding, stator winding, generator) - Is the motor protector normal? • If above points are not found, the PCB assembly is out of order. Replace it. | p.6 | |
| Blows fuses or trips circuit breaker (Gas Model) | • During ignition the dryer will draw X amps. With the burner ON, the dryer will draw X amps. If the dryer is drawing am- perages above this, then the house wiring, fuse box or circuit breaker is suspected to be at fault. • Igniter harness loose and shorted to base. • Incorrect wiring or wire shorted to ground. • Drive motor winding shorting to ground. | p.6 | |
| Will not heat (motor runs) | Open heating element. • Hi-Limit trips easily or is open. • Regulating thermostat trips easily or is open. • Membrane switch open. • Check Thermistor. | p.6 | |
| Will Not Dry Gas Model Poor Gas gnition | When the dryer is operated on a heat setting, the igniter should be energized and burner shall fire within 45 seconds at 120 VAC. The failure of a component in this system will usually be indicated by one of three symptoms: | p.6 |
Owners and our team usually reply within a day — and your question helps the next person too.