Parts and Technical Service guide Guía de servicio técnico y recambio Guide d’instructions et pièces de rechange

Ref.: Model 2190

The Samson RFX is designed to control and monitor the consumption and inventory balances of automotive fluid products with minimal installation and programming costs. The wall mounted keypad module consists of a 12-button keypad, LCD display and integral ticket printer. The RFX keypad can control up to 48 meters and track 8 different fluids and tanks. It is capable of sending and receiving data typically up to 300 feet in a service facility installation. A unique, patented feature of the control system is that the dispense trigger of the RFX Meter is locked until authorization from the keypad is received. After the dispense is completed, the user can top off the dispense and the actual amount used is sent back to the keypad and this meter returns to the locked status. Additionally, the meter can be installed on portable dolly systems offering control and monitoring of often high- cost lubrication products. Up to 50 operators can be defined with their own unique PIN number for accessing the system. The system provides dispense reports by operator, fluid type, meter or tank. This allows for flexibility in reviewing system activity.

E

Samson 2190 — E diagram (page 1)
Fig. 2

The operator enters his PIN number and selects the hose that the fluid is to be dispensed from. The operator then enters the required quantity and presses ENTER to confirm. The meter is then authorized to automatically dispense and shut off when the authorized amount of fluid is dispensed. The operator may then top off the vehicle for the proper fill, if necessary. The operator may allow the meter to “time out” or may depress “Reset” which sends all actual dispense data back to the keypad and puts the meter into a secure “Locked” status until the next authorized dispense work order is received from the keypad. After each dispense, a transaction ticket is printed showing the fluid and quantity dispensed along with the operator's name.

Operation/ Modo de empleo/ Mode d’emploi

E

Mount the keypad to the wall either inside the shop on a wall facing the shop. In either case mount the included remote antenna INSIDE the shop up high on the wall with line of sight to all the meters. Range is 300 feet unobstructed, be sure to test the keypad/antenna mounting position with a 2188 meter at all positions in the shop, and try to simulate a ‘worst case scenario’ with vehicle obstructions during testing. Performing this important step will ensure trouble-free service for the End User and no callbacks for the Installer.

E

RFX Keypad · Description/ Descripción/ Description · Installation and Configuration

Page 2 of the Samson 2190 user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Samson 2190 user manual
Page 3 of the Samson 2190 user manual — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP
Page 3 · click to enlarge
Page 3

PICTORAL DIAGRAM OF RF X LOGICAL SET-UP

Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 3)
Fig. 3
Page 4 of the Samson 2190 user manual — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP
Page 4 · click to enlarge
Page 4
Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 4)
Fig. 4

Keyboard Description:

FCC ID: GIF-RFKEYPAD FCC CERTIFIED, PART 15, SUBPART C This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 4)
Fig. 5
Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 4)
Fig. 6
Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 4)
Fig. 7
Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 4)
Fig. 8
Scroll KeyUsed to select options on active display
Home KeyPressing this key will return display to the PIN Number
Backspace KeyUsed to backspace when entering data
Enter KeyUsed to enter data and move to the next screen
Space KeyUsed to enter a space character when entering data
Alphanumeric KeysUsed to enter data on display. Hold down key

until the desired character is on display. Then release the key.

and Time/Date screens

Page 5 of the Samson 2190 user manual — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP
Page 5 · click to enlarge
Page 5

Default Screens:

  • The Personal Identification Number (PIN) number is 4 numeric digits
  • 1 supervisor account
  • Maximum of 50 operators
  • The supervisor account has access to the management screens (initialization, configuration, communication, report, external printer and internal printer reports)
  • The operator account only has access to the dispense order screens At power up, the following screens will be displayed:

01Jan2002 01:05 Version 1.0 US

This screen is displayed for system information only. It is displayed during 1 seconds every 5 seconds. The 4 other seconds the Enter Pin No. Screen will be displayed.

Enter Pin No.

Supervisor Menu:

To access the management menu, enter the Supervisor PIN Number. The Supervisor PIN is 4 numeric digits; default is 0000 at initial power-up.

**** · ,

Page 6 of the Samson 2190 user manual — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP
Page 6 · click to enlarge
Page 6
Management MenuThe management menu displays after entering the supervisor PIN Number
190. -

Select INI CNF MET REP

  • Choose which menu option is desired

Screens in INI can be accessed only when the Dispense Order list is empty. If the supervisor wants to change one of these parameters whereas the list is not empty, a screen message will be displayed. The supervisor must clear all transaction records through the CNF menu prior to entering the INI (initialization) menu. For screens with multiple choices, the selection is in inverse video. (i.e. The selection is green on black.)

Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 6)
Fig. 9

The scroll key is used to select an answer (Example Yes – No). The selection is in inverse video, it is validated with the ENTER key. To go to the desired menu, move the scroll key to your choice and press the ENTER key

, · ,

Page 7 of the Samson 2190 user manual — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP
Page 7 · click to enlarge
Page 7
Initialization MenuFlow Chart

aThe parameter changes will affect all data in memory (example: if we change the quantity unit from liters to gallons, the general quantity will be simply switched from liters to gallons (no conversion from the previous quantity unit to the new quantity unit) aNo pending dispense order

Samson 2190 — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP diagram (page 7)
Fig. 10
Page 8 of the Samson 2190 user manual — PICTORAL DIAGRAM OF RF X LOGICAL SET-UP
Page 8 · click to enlarge
Page 8

Initialization Menu Screens (INI):

  • System date and time are initially blank
  • System time is in military standard
  • System date is in format DD/MMM/YYYY (in English)
  • To change month, press

Enter Time:

--:--

  • Enter key with no entry Æ Jumps to TANK UNIT screen
  • If the time/date are already entered into the system, press enter with no date to move to the next screens.

Enter time by using the numeric keys to set a 24-hour military time of day.

when finished to move to the next initialization screen. • Enter Date:

Action: Date is changed and tank unit screen is displayed.

Enter date by first entering the two digit day of the month. The cursor will

automatically jump to the month. Use

to select month, then enter a four-digit year.

After date is set, press

to move to the next initialization screen.

Show 9 more labels / short text on this page
to increment month · Enter Time · , · , · Press · Enter Date --/jan/---- · , · , · ,
Page 9 of the Samson 2190 user manual — LITERS
Page 9 · click to enlarge
Page 9

Tank Initialization:

The tank screens are used to set up the tanks in the system. Each tank is assigned a number and a starting quantity level in the desired unit of measure. The following is the process for installing a tank:

  • Maximum of 8 Tanks
  • Tank ID’s are numbered 1 thru 8
  • Tank unit of measure can be quarts, liters, pints or gallons
  • By default, the unit of measure is liters
  • Set the dispensing unit of measure to the proper value
  • The tank stock level setting is updated after each dispense from the associated tank.
  • The tank stock level quantity setting Format is 5.3 digits (99999.999)
  • The remaining tank stock level quantity will be printed out to the nearest whole number after each dispense on the ticket.
  • The Supervisor may update the tank stock level quantity setting at any time by entering these screens to change stock levels

Tank Unit Tank No -

  • Enter key with no entry jumps to Fluids Screens

Enter a numeric value from 1 to 8 and press

LITERS

to select between LITERS, GALLONS, PINTS, QUARTS and REMOVE (REMOVE option will delete the tank from the system.)

to move to the next screen.

Show 8 more labels / short text on this page
, · , · Tank Unit · , · , · , · Use · Press
Page 10 of the Samson 2190 user manual — LITERS
Page 10 · click to enlarge
Page 10
No X---------

Use the numeric keys to enter a stock level from 00000.000 to 99999.999.

to move to next screen. Alphanumeric keys are validated only for some of the display menus. In these menus to enter a letter just hold the related key and the letters scroll. Then release the key when the letter you want is displayed.

Fluid Initialization:

This screen is used to set initial tank stock level or when ever supplier delivers fluid. The fluid screens allow the supervisor to set the fluid names used in the system. The parameters are:

  • Maximum of 8 Fluid types
  • The fluid type ID number ranges from 1 to 8
  • The fluid type name is a 16 alphanumeric string
  • Initially, the fluid type name is blank
  • Enter key with no entry Æ moves to Tank/Fluid relationship screen

Fluid No. 1

Show 11 more labels / short text on this page
Tank Stock Level · , · , · Press · Select Fluid · No - · , · , · Alphanumeric keys, · , · ,
Page 11 of the Samson 2190 user manual — LITERS
Page 11 · click to enlarge
Page 11

Tank-Fluid Relationship Screens:

The relationship between tank id and fluid type id will be 1:1 (one tank assigned to one fluid type id). For example, the supervisor may associate tank #1 with fluid #1 or tank #1 with fluid #2. Each tank must be associated with one and only one fluid type.

  • Enter key with no entry Æ moves to Create Hose screens

The user must enter a valid number for a fluid in the system. Pressing enter after a valid fluid number will bring the Tank-Fluid Tank No-, screen.

Show 8 more labels / short text on this page
Tank-Fluid · Tank No - · , · , · Tank-Fluid · Fluid No - · , · ,
Page 12 of the Samson 2190 user manual — LITERS
Page 12 · click to enlarge
Page 12
Adding and Deleting RF Meters(Meter and Hose are synonymous)

This set of screens allows the Supervisor to add or delete RF Meters from the keypad system.

  • The RF Meter identification number can be found on the RF Meter under the battery pack
  • The RF Meter identification number format is 10 decimal digits (-.---.---.---)
  • Leading zeros must be entered
  • X.XXX.XXX.XXX
  • RF Meters can be added and deleted
  • Maximum of 48 RF Meters
  • A given keypad can exchange data only with RF Meters whose identification number is in this list.
  • All RF Meters addresses and ids are unique
  • The relationship between tank and RF Meter will be 1:n (one tank assigned to n RF Meters). Since there will be a relationship between tank and fluid type, the RF Meter will be assigned to one fluid type.
  • Initially the RF Meter address list is empty

-.---.---.---

  • After validated RF Meter address is entered the tank-hose screen is displayed
  • Enter key with no entry Æ moves to Delete Hose screen
  • If RF Meter address already used Hose Address Already Used Screen is displayed

There is no active key. This screen is displayed if another RF Meter already uses the last three number of the RF Meter. If this screen displays check RF Meters in system to make some duplicate RF Meters do not exist, then check to see if this RF Meter has already been created in the system. It is displayed for 3 seconds and it comes back to create hose screen.

Show 5 more labels / short text on this page
Create Hose · , · , · Hose Address · Already Used
Page 13 of the Samson 2190 user manual — LITERS
Page 13 · click to enlarge
Page 13

The relationship between tank and RF Meter will be 1:n (one tank assigned to n meters). Since there will be a relationship between tank and fluid type, the RF Meter will be assigned to one fluid type. Assign the RF Meter to the tank in which it is connected.

ActionCreate hose screen is displayed

The system will automatically insert the created hose into the next available slot (1-48) in the system. The user has the option to change this hose number to any number (1-48) not currently in use. Note: The Hose ID is the number used to create dispense orders for the meter by the operator. The supervisor has the option to delete a hose/RF Meter through this screen. This is necessary when there is a change to the system; whereby, a RF Meter needs replacement for any reason. The supervisor should delete from the keypad the removed RF Meter prior to creating the new RF Meter. This will put the new RF Meter in the same logical position with the keypad and the dispense order process will remain the same.

-.---.---.---

  • If a RF Meter is deleted, the Delete Hose screen is displayed
  • Enter key with no entry Æ Create Operator screen is displayed
Show 10 more labels / short text on this page
No Action · Tank-Hose · Tank No - · , · , · Hose ID · _ _ · Delete Hose · , · ,
Page 14 of the Samson 2190 user manual — LITERS
Page 14 · click to enlarge
Page 14

Adding and Deleting Operators:

  • Only an operator with valid PIN can dispense fluid
  • A Maximum of 50 operators may be active in the system at a time
  • The operator id (PIN number) format is 4 numeric digits
  • The operator name format is 16 alphanumeric digits
  • Initially, the operator list is empty
  • If a new operator has been added, the Operator name screen is displayed
  • Enter key with no entry Æ Delete Operator screen is displayed
  • The New operator screen is displayed
  • Enter the operator’s name using the keypad and then press enter to add.

To delete an operator, enter the four-digit id number for the operator to be deleted and press enter.

Show 11 more labels / short text on this page
New operator · , · , · Operator XXXX · ---------------- · Alphanumeric keys, · , · , · Delete operator · , · ,
Page 15 of the Samson 2190 user manual — LITERS
Page 15 · click to enlarge
Page 15
Samson 2190 — LITERS diagram (page 15)
Fig. 11
Page 16 of the Samson 2190 user manual — YES / NO
Page 16 · click to enlarge
Page 16
Configuration Menu(CNF)

The Configuration Menu allows the supervisor to set-up all parameters for the Keypad Operation. The Supervisor is the only user with access to these screens.

Clearing Transactions from Keypad Memory:

  • Removes all transactions (Dispense Orders) previously recorded in memory
  • Clear transactions will erase WO results data, Data will be cleared confirmation.

YES / NO

The selection is in reverse video

Use the scroll key to select between YES/NO.

YES / NO

The selection is in reverse video

Action: The keypad will automatically return to the Clear Transacts screen on YES or NO confirmation

Show 6 more labels / short text on this page
Clear Transacts · , · , · Confirm Clear · , · ,
Page 17 of the Samson 2190 user manual — YES / NO
Page 17 · click to enlarge
Page 17

System Reset:

Allows the user to reset all the configuration parameters to default values:

YES / NO

  • If yes, the keypad asks the user to confirm
  • If no, the keypad displays the mileage type screen

YES / NO

ActionThe keypad returns to the System Reset screen

Mileage Type:

Allows the user to select how mileage is stored in the keypad

  • KM/MILES
  • The mileage type by default is KM.

Mileage Type KM / MILES

  • Press enter key to move to Mileage Info screen
Show 8 more labels / short text on this page
System Reset · , · , · Confirm Reset · , · , · , · ,
Page 18 of the Samson 2190 user manual — YES / NO
Page 18 · click to enlarge
Page 18

Mileage and Registration Information Option:

  • Allows the supervisor to select the storage of vehicle mileage and registration information for each dispense order.
  • 16 numeric digit field
  • YES/NO to the option of entering the vehicle mileage information for each dispense order
  • Mileage information by default is NO

YES / NO

Action: Use the scroll key to select YES/NO, press enter key to move to the Registration option screen

  • 16 numeric digit field
  • YES/NO to the option of entering the vehicle registration information for each dispense order
  • Registration information by default is NO

Regist. Info YES / NO

Action: Use the scroll key to select YES/NO, press enter key to move to the keypad timeout screen

Show 5 more labels / short text on this page
Mileage Info · , · , · , · ,
Page 19 of the Samson 2190 user manual — YES / NO
Page 19 · click to enlarge
Page 19

Keypad Timeout Option:

  • Timeout parameter corresponding to the time it takes to validate after all dispense order data has been entered. If the enter button is not pressed within the time allocated, the keypad display goes back to the initial menu, and the input data is erased.
  • The keypad timeout is between 0 to 255 seconds (0 no timeout) and the default for this feature is 10 seconds
  • Press Enter key to move to Hose Inactive Timeout Option

Hose Inactive Timeout Option:

  • Essentially, this is the time the user has to top-off the dispense and completing the automatic batch.
  • Timeout parameter corresponding to the time that a RF Meter could stay inactive after the reset key has been pressed on the meter.
  • If the user has not pressed reset on the RF Meter within the timeout period, the RF Meter will transmit the dispense order quantity to the keypad and lockout the RF Meter.
  • Meter inactive timeout is sent to the RF meter. It’s the meter (ER) that is responsible of tracking this timer.
  • The meter inactive timeout is set for all RF Meters.
  • The meter inactive timeout is between 0 to 65534 seconds (0 = no timeout) and the default value is 10 minutes.
  • Press Enter key to move to Display Timeout Option
Show 6 more labels / short text on this page
Keypad Timeout · , · , · Hose Inactive · , · ,
Page 20 of the Samson 2190 user manual — YES / NO
Page 20 · click to enlarge
Page 20
Display Timeout Option(Do Not Change)
  • Timeout parameter corresponding to the time for displaying information on the keypad LCD before it is refreshed with new information
  • The display timeout is set at 2 seconds
  • Press Enter key to move to Internal Printer Option

Internal Printer Option:

  • YES / NO. Parameter indicating the existence of an internal printer (CUSTOM FT190).
  • The internal printer value is set by default NO ( a The keypad will not detect the existence of a printer)

YES / NO

  • Use scroll key to select the internal printer setting
  • Press Enter key to select the internal printer setting and move to External Printer Option

External Printer Option:

  • YES / NO. Parameter indicating the existence of an external printer (EPSON LX300).
  • The external printer value is set by default NO

YES / NO

Show 9 more labels / short text on this page
Display Timeout · , · , · Internal printer · , · , · External Printer · , · ,
Page 21 of the Samson 2190 user manual — YES / NO
Page 21 · click to enlarge
Page 21
  • Use scroll key to select the external printer setting
  • Press Enter key to move to select the external printer setting and Supervisor Password Option

Supervisor Password Option:

The default supervisor password for protecting the modification of the supervisor id is 0000. The Supervisor can change this password during the initial set-up of the system. Maximum of 1 Supervisor login password

  • Use numeric keys to enter the new password then press enter.
  • Enter key with no entry Æ No change to password and displays buzzer option.

Action: reenter new password to confirm.

Buzzer Option:

This screen provides the user with the option to have a beep on every key entry. The default is YES.

Buzzer YES / NO

Show 9 more labels / short text on this page
Super new pass · **** · , · , · Super Confirm · , · , · , · ,
Page 22 of the Samson 2190 user manual — YES / NO
Page 22 · click to enlarge
Page 22

Action: Select YES or NO by using the scroll key, then press Enter. The keypad will display the Supervisor Menu. Meter Reset Menu (MET):

  • Only the supervisor has access to this process.
  • The supervisor may delete a dispense order in the keypad que for a single hose or all hoses in the system.
  • If the supervisor selects all RF Meters, all dispense orders in the que will be deleted and all meters may be programmed for a dispense order.

YES / NO

  • If YES Æ Start (Hoses Init) is displayed
  • If NO Æ User is prompted for a hose number to reset
  • Press ENTER to reset the hose

Meter Reset Menu Flowchart:

Samson 2190 — YES / NO diagram (page 22)
Fig. 12
Show 5 more labels / short text on this page
Init all Hose · , · , · Start Hoses Init · Press enter
Page 23 of the Samson 2190 user manual — YES / NO
Page 23 · click to enlarge
Page 23
Report Menu Screens(REP)

The supervisor has the opportunity to print out a variety of reports, if there is an external printer connected to the keypad. INI: Prints all parameters associated with the system initialization CNF: Prints all parameters selected for the configuration of the keypad MET: Prints the status of all hoses/meters REP: Prints the dispense order history The external printer has to be activated and connected. aWhen the keypad is printing out a report or a receipt, the keypad keyboard will be locked for all new data entry (i.e. the operator will not be able to enter a new Dispense Order List while the keypad is printing). aIf the keypad detects an error on the internal printer or the external printer (not connected, out of paper or off line), the keypad keyboard will be locked for all new data entry and an error will displayed on the keypad LCD. The user should check the printers for off-line or out of paper conditions. aIf an error is detected while printing, the keypad will not purge the memory (especially in the case of the Dispense Order List report) aAfter printing out the Dispense Order List report, the Dispense Order list memory is erased automatically The dispense order receipt is automatically (after a user prompt message) printed out after the RF reception of the dispense order result

Select Report INI CNF MET WO

  • Use the scroll key to select report option
  • Enter key with no entry Æ keypad returns to Supervisor Menu screen

, · ,

Page 24 of the Samson 2190 user manual — YES / NO
Page 24 · click to enlarge
Page 24

Initialization Report: DD/MMM/YYYY INITIALIZATION REPORT HH:MI TNK PRODUCT LEVEL UNT === ================ ===== ====== 1 Fluid 1 name 99999 LITERS 2 Fluid 2 name 99999 LITERS (…) 7 Fluid 7 name 99999 LITERS 8 Fluid 8 name 99999 LITERS ID ADDR TNK === ================ === 123 124456 1 234 561444 2 (…) (…) (…) ID PIN NAME === ==== ================ 1 1234 John SMITH 2 1235 Paul GREEN 3 1236 Mike BROWN (…) (…) (…) ID PRODUCT === ================ 1 Fluid 1 name 2 Fluid 2 name (…) (…) 7 Fluid 7 name 8 Fluid 8 name DD/MMM/YYYY

Date of the printout HH:MI Time of the printout TNK Tank No PRODUCT Fluid type name QTY Quantity dispensed UNT Unit ADDR Meter RF address ID RF Meter Id (Last 3 address characters) TNK Tank No PIN User pin number NAME User name

Page 25 of the Samson 2190 user manual — YES / NO
Page 25 · click to enlarge
Page 25

Configuration Report: DD/MMM/YYYY CONFIGURATION REPORT HH:MI Mileage Type KM Registration Info NO Mileage Info NO Internal printer Yes External printer Yes Address printer Buzzer Yes Approved PTB NO Supervisor pass 1234 Hose Inactive 600 Keypad Timeout 10 Display Timeout 2 On-Off sequence 999999

Select Report INI CNF COM WO

  • Use scroll key to move to CNF and press Enter key
  • Enter key with no entry Æ Supervisor Menu screen is displayed
ActionAfter Report is completed the Select Report screen is displayed
Show 4 more labels / short text on this page
, · , · Start CNF Report · ,
Page 26 of the Samson 2190 user manual — YES / NO
Page 26 · click to enlarge
Page 26

Communications Report: DD/MMM/YYYY COMMUNICATION REPORT HH:MI ADDR ID STA ====== ==== === 0.000.000.101 1 inactive 0.000.000.137 2 inactive 0.000.000.111 3 inactive 0.000.000.126 4 inactive 0.000.000.127 5 inactive 0.000.000.109 6 inactive 0.000.000.100 7 inactive 0.000.000.135 8 inactive DD/MMM/YYYY

  • Date of the printout HH:MI Time of the printout ADDR Meter RF address ID RF Meter Id (Last 3 address characters) STA Status of the RF link:
  • OK Î RF link is established
  • KO Î RF link not established
  • ? Î RF link doubtful

Select Report INI CNF COM WO

  • Use scroll to move to COM and press Enter
  • Enter key with no entry Æ Supervisor Menu screen is displayed
ActionAfter printing Select Report Menu is displayed
Show 4 more labels / short text on this page
, · , · Start COM report · ,
Page 27 of the Samson 2190 user manual — YES / NO
Page 27 · click to enlarge
Page 27

Dispense Order Reports:

Select Report INI CNF COM WO

  • Scroll to WO and press Enter key
  • Enter key with no entry Æ Supervisor Menu screen is displayed

Select REP USR PRO HOS TNK

ActionScroll to report to print and press the Enter key

There are four reports that may be printed associated with Dispense Orders:

  • USR: Print dispense orders by Operator
  • PRO: Print dispense orders by Fluid Type
  • HOS: Print dispense orders by Hose/Meter
  • TNK: Print dispense orders by Tank
User Report (USR)DD
Samson 2190 — YES / NO diagram (page 27)
Fig. 13

USER PRODUCT QTY ================ ================ ===== JOHN SMITH FLUID TYPE 1 99999 FLUID TYPE 2 99999 FLUID TYPE 3 99999 FLUID TYPE 4 99999 PAUL GREEN FLUID TYPE 5 99999 FLUID TYPE 6 99999 FLUID TYPE 7 99999 FLUID TYPE 8 99999 (…)

ActionAfter printing the Select Report Screen is displayed
Show 5 more labels / short text on this page
, · , · , · , · ,
Page 28 of the Samson 2190 user manual — YES / NO
Page 28 · click to enlarge
Page 28

Product Report (PRO): DD/MMM/YYYY STATISTICAL REPORT BY PRODUCT HH:MI PRODUCT USER QTY ================ ================ ===== FLUID TYPE 1 JOHN SMITH 99999 PAUL GREEN 99999 FLUID TYPE 2 JOHN SMITH 99999 PAUL GREEN 99999 FLUID TYPE 3 JOHN SMITH 99999 PAUL GREEN 99999 (…)

ActionAfter printing the Select Report Screen is displayed

Hose/Meter Report (HOS): DD/MMM/YYYY STATISTICAL REPORT BY RF METER HH:MI ADDR ID USER QTY ====== === ================ ===== 123456 456 JOHN SMITH 99999 PAUL GREEN 99999 234561 561 JOHN SMITH 99999 PAUL GREEN 99999 (…)

ActionAfter printing the Select Report Screen is displayed
Show 4 more labels / short text on this page
Start Report · , · Start Report · ,
Page 29 of the Samson 2190 user manual — MENU
Page 29 · click to enlarge
Page 29

Tank Report (TNK): DD/MMM/YYYY STATISTICAL REPORT TANK LEVEL HH:MI TNK PRODUCT LEVEL UNT === ================ ===== ======= 1 5W30 OIL 123 LITERS 2 GEAR OIL 1111 LITERS 3 ATF 111 11111 GALLONS 4 HYDRAULIC FLUID 232 QUARTS 5 10W40 OIL 3466 PINTS 6 WASHER FLUID 1 LITERS 7 5W40 OIL 2344 LITERS 8

BEER 43234 PINTS

ActionAfter printing the Select Report Screen is displayed

REPORT

Select Report INI CNF COM WO

MENU

Select REP USR PRO HOS TNK

Show 7 more labels / short text on this page
Start Report · , · Report Menu Flowchart · Start INI Report · Start CNF Report · Start COM Report · Start Report
Page 30 of the Samson 2190 user manual — BEER 43234 PINTS
Page 30 · click to enlarge
Page 30

Internal Printer Reports:

FLU: Prints all fluids created in the system HDS: Prints all hose numbers with meter serial numbers TNK: Prints all tanks created in the system USE: Prints all operators created in the system WO: Prints all work orders pending PEN: Prints the current meter status “INACTIVE”: Hose is ready “ACTIVE”: A dispense order is pending “UNREACHABLE”: Hose is not ready

- Hit reset button on meter to begin communications test and reset meter. PAR: Prints the current setting in configuration menu MEM: Prints the memory configuration for system NOTE: It is recommended that the supervisor print all internal reports and store hard copies after setting up the system.

Samson 2190 — BEER 43234 PINTS diagram (page 30)
Fig. 14
Page 31 of the Samson 2190 user manual — Fluid Type Definitions
Page 31 · click to enlarge
Page 31

Fluid Type Definitions

Fluid id Name

1 2 3 4 5 6 7 8

Maximum Fluid types is 8

The Fluid name can be 16 characters in length

Page 32 of the Samson 2190 user manual — Tank Definitions
Page 32 · click to enlarge
Page 32

Tank Definitions

Tank id Tank Level Tank Capacity

1 2 3 4 5 6 7 8

Maximum of 8 Tanks

The Tank Capacity value is formatted 00000.000

Page 33 of the Samson 2190 user manual — Hose/Meter Definitions
Page 33 · click to enlarge
Page 33

Hose/Meter Definitions

Hose/Meter id Address Number x.xxx.xxx.xxx 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Samson 2190 — Hose/Meter Definitions diagram (page 33)
Fig. 15 · Hose/Meter Definitions

Maximum of 48 Hose/Meters

Hose/Meters address is a 10 digit number

Address Data Format is x.xxx.xxx.xxx

Page 34 of the Samson 2190 user manual — Hose/Meter Definitions
Page 34 · click to enlarge
Page 34

Hose/Meter Definitions

Hose/Meter id Address Number x.xxx.xxx.xxx 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Samson 2190 — Hose/Meter Definitions diagram (page 34)
Fig. 16 · Hose/Meter Definitions

Maximum of 48 Hose/Meters

Hose/Meters address is a 10 digit number

Address Data Format is x.xxx.xxx.xxx

Page 35 of the Samson 2190 user manual — User Definitions User id User Name Pin id
Page 35 · click to enlarge
Page 35

User Definitions User id User Name Pin id

Samson 2190 — User Definitions User id User Name Pin id diagram (page 35)
Fig. 17 · User Definitions User id User Name Pin id

1 Reserved Supervisor 0000 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

The User Name is up to 16 characters

The User Pin id is a 4 digit number with leading 0’s required

Page 36 of the Samson 2190 user manual — User Definitions User id User Name Pin id
Page 36 · click to enlarge
Page 36

User Definitions User id User Name Pin id

Samson 2190 — User Definitions User id User Name Pin id diagram (page 36)
Fig. 18 · User Definitions User id User Name Pin id

26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

The User Name is up to 16 characters

The User Pin id is a 4 digit number with leading 0’s required Maximum of 50 users

Page 37 of the Samson 2190 user manual — User Definitions User id User Name Pin id
Page 37 · click to enlarge
Page 37
Samson 2190 — User Definitions User id User Name Pin id diagram (page 37)
Fig. 19 · User Definitions User id User Name Pin id

Ask about the Samson 2190

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Samson 2190

Be the first to ask — other owners or our team will answer.

Original document

Samson 2190 manual PDF

37 pages·1.1 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…