Instruction/ maintenance manual of the product Platinum APS 675 Audiovox
Go to page of 18
Model APS 675 Installation Manual 3 Channel Remote Start / Keyless Entry System Installation Instructions This Unit Is Intended For Installation In V ehicles With 12 V olt Negative Ground Electrical Systems, Gasoline or Diesel With T rue T ach Reference And Automatic T ransmissions Only .
The APS-675 Remote Start/Keyless Entry System is designed to be used with Automatic Transmission Vehicles Only! The unit provides a selectable ignition control that allows a 10 second output for glow plug pre-heat which may be required for certain diesel vehicles, (see selectable feature #9).
3 allowed for the body of the switch, and also that the drill will not penetrate any existing factory wiring or fluid lines. Drill a 1/4" hole in the desired location and mount the switch by passing it through the panel from the underside. Secure the switch using the nut, star washer , and on/off face plate.
used ) and the neutral safety switch as shown in the following diagram. Failure to connect this wire to the ignition switch side of the of the neutral safety switch can result in personal injury and property damage. SEE NEUTRAL ST ART SAFETY TEST FOR FUR THER DET AILS.
WIRING CONNECTIONS: 12 Pin Input / Output Harness Black Wire: Chassis Ground Source Connect the Black wire to a known vehicle ground source or to a solid clean metal part of the chassis. Be certain to remove any paint or grease and secure this wire with a self taping screw and ring terminal.
Brake Switch Positive Shutdown Detail YELLOW w/ BLACK Tracer Wire: + 12 Volt Alarm By - Pass Output NOTE: YOU MUST DISCONNECT THE IGNITION INPUT OF THE ALARM FROM ANY OTHER WIRE THAT IT IS PRESENTLY CONNECTED TO IN THE VEHICLE.
The Light Blue wire can be used to accommodate the following situations: A. Shock Sensor By Pass: If there is Shock Sensor used with an alarm system and it is not shunted during the Remote Start activation period, then vibration from the running vehicle can cause the alarm to trigger .
DARK GREEN/ORANGE Wire: Tach Sensor Input This wire will continually monitor the engine tach rate while the unit is under power of the Remote Start module. This wire will be routed to the vehicle ECM tach input or through the firewall into the engine compartment and connect to the negative side of the ignition coil.
3 Wire Positive Switched Door Locks: In this application, the Red wire of the two pin harness provide sa+1 2 volt pulse during the disarming sequence, or pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire from the factory door unlock switch to the factory door unlock relay .
T ypically this output will be used to re-lock the vehicle doors if the doors unlock automatically when the ignition circuit transitions to off. Black w/ Y ellow T race Wire: Ground Output During S tart (Crank) The Black w/ Y ellow Trace wire will provide a 300 mA ground output while the starter output of the remote start unit is active.
Dark Blue/Black and Green/White - 2 Pin Input/Output Harness: Dark Blue/Black T race Wire: External T rigger Input The Dark Blue/Black trace wire allows the remote start unit to be activated from an external source. The intent of this wire is to allow the unit to be controlled from a "POSSE/CAR-LINK" paging system or similar device.
To program these selectable features: 1. Start with the programming switch in the OFF position. 2. Turn the ignition key to the ON position. 3. Flip the program switch ON - OFF - ON - OFF - ON - then OFF. 4. Immediately turn the ignition key OFF, then back to ON.
TIMED ST ART PROGRAM: The Remote Start unit has the ability to start the vehicle automatically at timed intervals. This feature is useful in extremely cold climates where starting the engine is the only means to keep the battery charged and fluids warm.
T o test the integrity of this circuit: 1. With the driver's window in the down position, start the vehicle using the RF transmitter . 2. Reach inside the car and pull the hood release. 3. Raise the hood and confirm that the remote start unit shuts down.
MECHANICAL NEUTRAL SAFETY SWITCH CONSIDERA TIONS: Mechanical neutral safety switch configurations differ slightly in that they do not offer the same level of safety when installing a remote start device.
Additional information concerning Key In Sensor method s1&2a r e listed below and should be reviewed before considering either alternative. Method 1 will allow the safety required for the remote s.
METHOD 2 T o connect to the key in sensor circuit as shown for method 2: A . Locate the control wire that connects the drivers door pin switch to the key in sensor switch. B . Cut this wire and connect the ignition cylinder side to chassis ground. C .
WIRING DIAGRAM 18 2nd White © 1998 Audiovox Corp., Hauppauge, N.Y . 1 1788 Form No. 128-5367.
An important point after buying a device Audiovox Platinum APS 675 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Audiovox Platinum APS 675 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Audiovox Platinum APS 675 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Audiovox Platinum APS 675 you will learn all the available features of the product, as well as information on its operation. The information that you get Audiovox Platinum APS 675 will certainly help you make a decision on the purchase.
If you already are a holder of Audiovox Platinum APS 675, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Audiovox Platinum APS 675.
However, one of the most important roles played by the user manual is to help in solving problems with Audiovox Platinum APS 675. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Audiovox Platinum APS 675 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center