Instruction/ maintenance manual of the product Commercial Power Direct Vent Water heater Rheem
Go to page of 28
Printed in USA F O R Y O U R S A F E T Y ! — Do no t s to re or us e gas ol in e or ot her fla mma b le v a p o r s o r l iq u id s o r o th e r c o mb u st ib l e m at er i al s i n t he v i c i ni ty o f t hi s or an y ot he r ap pl i an c e. T o d o s o m a y r es u lt in a n e x p lo s io n o r f ir e.
S af et y In f or ma t io n S af et y P re ca ut io ns . . . . . . . . . . . . . . . 3- 4, 1 6 I nt r o du ct io n Lo ca l In st al la ti on R eg ul at io ns . . . . . . . . . . 5 W at er H ea te r Lo ca ti on . . . . . . . . . . . . . . . . . 5 I ns ta ll at io n In st ru ct i on s I n s p e c t S h i p m e n t .
3 T o m e e t c o m m e r ci a l w a t e r us e ne e d s , th e t he r m o s t a t on th i s w a te r h e a t e r is ad j u s t ab le up to 18 0° F . Ho we ve r , wa te r te m p er a t u r e s o ve r 1 2 5 ° F . c a n c a u s e s e ve re b ur n s i n s t a n tl y o r d e a t h f r om s c a ld s .
4 General Safety Precautions Be sure to read and understand the entire Use & Care Manual bef ore attempting to install or operate this water heater . P ay particular attention to the follo wing General Safety Precautions. F ailure to follow these warnings could result in a fire or e xplosion, causing proper ty damage , bodily injur y or death .
5 Read and Review this entire Manual with special emphasis on the V enting Sections (Pa ges 8-12) and Operation Section ( P ag es 1 4- 1 7 ) p r i o r t o a n y i n s t a ll a t i o n w or k .
T h e ma n uf ac t u r e r ’ s w ar r a n t y d o e s n o t c o ve r a n y d a m a ge o r d e f e c t c a u s e d b y i n s t a l la t i o n , or a t t a c hm en t , or u s e o f a n y s p e c i a l.
SYSTE M SENTI NEL POWER THERMOST AT I GN ITION PILO T VALVE MAIN VALVE ECO ® T emperature & Pressure Relief V alve T o Gas Supply Manual Gas Shut-Off Ground Joint Union Thermostat Cap Gas V alve Air Gap 6" Sediment T rap Hot Outlet Cold Water Inlet Shut-Off V a lve Ref er to V enting section on pages 8-11 in this manual.
N E VE R us e o pe n f la me t o te st f or g a s le ak s, a s bo di l y in ju ry or p r o p er ty d a m a g e c o u l d r e su l t . PRESSURE TESTING THE GAS SUPPL Y SYSTEM — The water heater and i.
9 MINIMUM AND MAXIMUM VENT LENGTHS Char ts are for installation from 0 - 2000 ft. elev ation ONL Y . (Please see supplement sheet f or installations abov e 2000 f eet.) NO TICE: Be sure to mount inlet v ent ter minal 6 inches higher than the outlet vent ter minal.
1 0 Installation GP100-250 § § § § § § Inlet Outlet Sh ee t M eta l S hiel d o n B ric k o r Ma so nry Wa lls Ou ts ide of Bu il din g W all § Mo rtar or Si li con e C aul k F rom W ate r He at.
11 Installation 3 . Maximum twenty-f our (24) inches above roof lev el without additional suppor t for v ent pipe. 4. F our (4) feet from any gable, dor mer or other roof str ucture with building interior access (i.e., v ent, window , etc.). 5 . T en (10) f eet from any f orced air inlet to the building.
1 In accordance with current CAN/CGA-B149 Installation Codes. 2 In accordance with current ANSI Z223.1/ NFP A 54 National Fuel Gas Code. + A vent shall not terminate directly above a side walk or pav ed dr ive wa y that is located between two single f amily dwellings and ser ves both dwellings .
A. W ater Heater Location ❑ Close to area of vent. ❑ Indoors and protected from freezing temperatures. ❑ Proper clearance from comb ustible surf aces obser ved and water heater not installed on carpeted floor . ❑ Air supply free of corrosive elements and flammab le vapors.
1 4 Operation 1. LIGHTING PROCEDURE - Lighting procedures are outlined on the label pictured belo w . This label is also located on the water heater near the ther mostat.
1 5 FOR YOUR SAFETY READ BEFORE OPERATING 1. TURN OFF ALL ELECTRIC POWER TO THE APPLIANCE IF SERVICE IS TO BE PERFORMED. 2. SET THE THERMOSTA T TO LOWEST SETTING. TO TURN OFF GAS TO APPLIANCE OPERATING INSTRUCTIONS B. BEFORE OPERATING smell all around the appliance area for gas.
2. TEMPERA TURE SETTINGS — The thermostat is adjusted to its low est temperature position when shipped from the factory . T o meet com - mercial water use needs, it is adjustable up to 180°F (82°C). How- e ver , water temperatures ov er 125°F (52°C) can cause sev ere bur ns instantly or death from scalds.
17 Pro per l y m ain tai ned , thi s wa ter h eat er wil l prov ide year s of de pen dable, trouble free ser vice. It is strongly suggested that a regular routine main- tenance program be established and follow ed by the owner .
D . BLOWER — Clean the blow er per iodically to remov e any buildup of lint or dir t. Remov e the inlet plate and blo w out any lint or dir t on the wheel and on the screen of the inlet plate. Bef ore operation, re-install the inlet plate to the blo wer .
1 9 ® S Y S T E M S E N T I N E L P O W E R T HE R MO S T A T I G N I T I O N P I L O T V AL V E M A I N V AL V E E C O “System Sentinel” Diagnostic System The “System Sentinel” Diagnostic sy.
2 0 N O S e c t i o n 1 . .. t h e “ P O WE R” L ED “System Sentinel” T r oubleshooting Guide I s t h e “ P O WE R ” LE D I l l u m i na t e d ? I s t h e “ O N/ O F F ” S wi t c h in t h e “ O N ” p o s i ti o n ? T urn switc h to ON position .
2 1 S e c t i o n 2 . .. t h e “ T H E R MO S T A T ” L E D “System Sentinel” T r oubleshooting Guide I s Th er m o s t a t s e t a t a t e m p e r a - t u r e h i g h e r t h a n t h e w a te r t e m - p e r a t u r e i n t a n k ? Thermostat is de f ect ive or out of ca lib rat ion a n d m us t b e r e pl a c e d .
2 2 Y E S CA UTION ! L a b e l a l l w i r e s p r i o r t o d i s c o nn e c t i o n w h e n s e rv ic i n g c o n t r ol s . Wi ri n g e r r or s c a n c a u se i m p r o p er a n d d a n ge r ou s o p e r a t i o n . VE R I F Y P R OP - E R O P E R A T I O N A F T E R SE R V I C I N G! S e c t i o n 3 .
S e c t i o n 4 . .. t h e “ P I L O T V A L VE ” L E D “System Sentinel” T r oubleshooting Guide I s t h e S p a rk I g n i t o r o p e r a t i n g ? ( C a n s p a r k in g b e h e a r d? ) I s t h e “ I GN I T I O N ” L E D i l l u m in a t e d ? Ignition Contr ol Module is inoperable and must be r e p l a c e d .
CA UTION ! L a b e l a l l w i r e s p r i o r t o d i s c o nn e c t i o n w h e n s e rv ic i n g c o n t r ol s . Wi ri n g e r r or s c a n c a u se i m p r o p er a n d d a n ge r ou s o p e r a t i o n . VE R I F Y P R OP - E R O P E R A T I O N A F T E R SE R V I C I N G! S e c t i o n 5 .
2 5 Replacement P ar ts Instructions F or Placing a P arts Order All par ts orders should include: The model and serial number of the water heater from the r ating plate. Specify type of gas (natural or LP) as mar ked on the r ating plate. Part descr iption (as noted below) and number of parts desired.
2 6 Wiring and Schematic Dia grams F i gu re 1 4 . — Di a gr am s f or u ni ts s up pl ie d wi th H o ne yw el l V R8 30 4 P or VR 83 04 M Ga s V a lv e a nd H on e yw el l S8 60 0M I gn it io n Co nt r ol , H on e y we ll T he rm o - s t at a nd T e mp er at u re L im it in g S wi tc h f or v en t p ip e.
Wiring and Schematic Dia grams 1 IGNITION LED THERMOST A T LED POWER LED BR-3 BR-3 Y-3 BL-5 R-3 GY-1 BR-4 BR-3 BL-4 GY-1 BL-5 R-3 BR-4 BR-3 BL-4 IGNITION CONTROL LED INDICA TORS MAIN V AL VE ECO PILO T V AL VE IGNITION THERMOST A T POWER MV MV PV PV 24V MV/PV GY-2 BR-1 GND PV MV GND GAS V ALVE 1 5 6 BR-2 24V 120V PILO T ELECTRODE ASSY .
2 8 The f ollowing Gask ets are required for Normal Maintenance f or all Models: SP5886 T ank Handhole Sealplate Gasket All other P ar ts can be ordered by pro viding the f ollowing inf or mation: 1. Description of Part(s), such as: Main Gas V alve Pilot Bur ner Main Bur ner Ther mostat Blower Assemb ly Anode Rod Or other par ts as required.
An important point after buying a device Rheem Commercial Power Direct Vent Water heater (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Rheem Commercial Power Direct Vent Water heater yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Rheem Commercial Power Direct Vent Water heater - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Rheem Commercial Power Direct Vent Water heater you will learn all the available features of the product, as well as information on its operation. The information that you get Rheem Commercial Power Direct Vent Water heater will certainly help you make a decision on the purchase.
If you already are a holder of Rheem Commercial Power Direct Vent Water heater, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Rheem Commercial Power Direct Vent Water heater.
However, one of the most important roles played by the user manual is to help in solving problems with Rheem Commercial Power Direct Vent Water heater. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Rheem Commercial Power Direct Vent Water heater along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center