Thank-you for purchasing a REGENCY FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
Keep those REGENCY FIRES burning.
SAFETY NOTE: If this Insert is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building, fi re offi cials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.
The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.




SAFETY LABEL FOR I2400M
(Duplicate Serial #) 246
This is a copy of the label that accompanies your Regency Insert. We have printed a copy of the contents here for your review.
Jan Feb Mar Apr May June
July Aug Sept Oct Nov Dec
DATE OF
SIGNATURE
MANUFACTURED BY FPI LTD.
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH July 1990, PARTICULATE EMISSION STANDARDS.
CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
FIREPLACE PRODUCTS INTERNATIONAL LTD.
MADE IN CANADA 918-176b
READ ABOVE INSTRUCTIONS.
Manufactured By:
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY
FIREPLACE OR FACTORY BUILT FIREPLACE. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN
TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE
A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE MANUFACTURER SUPPLIED SCREEN
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 0.5IN / 13MM ABOVE AN
ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-
COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN / 457 MM TO FRONT AND (G) 8 IN / 205 MM
OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. IF INSTALLED IN
MUST BE USED. REPLACE GLASS ONLY WITH CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY
TO SIDES FROM FUEL DOOR. 0.5" FLOOR PROTECTION NEEDS TO BE WITH k=0.84.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
THE I2400M MEETS UL 737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.
CERTIFIED FOR USE IN CANADA AND U.S.A.
COMPONENTS REQUIRED FOR INSTALLATION: 6IN / 150MM STAINLESS STEEL LINER.
OCCUR RAPIDLY. DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
MODEL: I2400M
ADJACENT SIDEWALL A) 11 in / 280 mm
MANTLE B) 20 in / 508 mm
TOP FACING C) 12 in / 305 mm
SIDE FACING D) 8 in / 200 mm
YOUR AREA.





Regency Inserts are constructed with the high- est quality materials and assembled under strict quality control procedures that insure years of trouble free and reliable performance.
the operation of the fi replace may be removed providing they can be stored on or within the fi replace for re-assembly if the insert is removed.
Before installing, check and clean your chimney system thoroughly. If in doubt about its condi- tion, seek professional advice. Your Regency Insert is designed for installation into a masonry fi replace that is constructed in accordance with the requirements of "The Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Ap- pliance", N.F.P.A. 211, the National Building Code of Canada, or the applicable local code requirements.
It is important that you read this manual thor- oughly and fully understand the safe instal- lation and operating procedures. The more you understand the way your Regency Insert operates, the more enjoyment you will experi- ence from knowing that your unit is operating at peak performance.
b. the chimney damper may be removed
to install the chimney liner.
The appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.
Regency Inserts are designed with a 6" (152mm) fl ue.
Fireplaces.
"WARNING: This fi replace has been converted for use with a wood insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fi replace re-approved by the authority having jurisdiction."
In order for a solid-fuel insert to be certifi ed for use in factory-built fi replaces, the above information must be clearly stated in the instal- lation manual and appropriate markings. Final approval is contingent on the authority having jurisdiction.
Your fi replace opening requires the following minimum sizes:
Two faceplates are available to seal the fi replace opening:
Standard Oversize 40" W x 30" H 48" W x 33" H
Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.


Your insert is very heavy and will require two or three people to move it into position. The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges. Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation.
The Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your fl ue connector and the insert collar. Detailed installation instructions are included with the kit.
The convection grills are installed before the unit is positioned inside the fi replace.
Position the grill on the inside bodyface side and fasten using the bolts, washers and nuts provided (2 per side) as shown in the diagrams.
View from Rear of Insert
on the front side have rounded edges and the rear holes have fl at edges.

The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below.
Side and Top facing is a maximum of 1.5" thick. Floor protection must be non-combustible, insula- tive material with an R value of 1.1 or greater.
* Hearth thickness of 0.5" with k value = 0.84", R value = 6 or greater.
** A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
** Max. mantle depth is 10" (254mm).
Thermal fl oor protection is not required if the unit is raised 3.5" minimum (measured from the bottom of the stove). However, standard ember fl oor protec- tion is required. It will need to be a non-combustible material that covers 16" (406 mm) in the US and 18" (450 mm) in Canada to the front of the unit and 8" (200 mm) to the sides.
If the unit is not raised, thermal fl oor protection required is 18" (450 mm) in the US and Canada.
Clearance diagram for Installations
All fl oor protection must be non-combustible (i.e., metals, brick, stone, mineral fi ber boards, etc.) Any organic materials (i.e. plastics, wood paper prod- ucts, etc.) are combustible and must not be used. The fl oor protection specifi ed includes some form of thermal designation such as R-value (thermal resistance) or k-factor (thermal conductivity).
Minimum Hearth Extension for the front (E) and sides (G) are measured from the
fuel door opening.
The specifi ed fl oor protector should be 3/8" (18mm) thick material with a K - factor of 0.84.
Step (b): Calculate R of proposed system. 4" brick of C = 1.25, therefore Rbrick = 1/C = 1/1.25 = 0.80 1/8" mineral board of k = 0.29, therefore Rmin.bd. = 1/0.29 x 0.125 = 0.431 Total R = Rbrick + Rmineral board = 0.8 + 0.431 = 1.231.
Thermal Conductance:
C = Btu = W (hr)(ft2 )(oF) (m2))(K)
The proposed alternative is 4" (100mm) brick with a C-factor of 1.25 over 1/8" (3mm) mineral board with a K-factor of 0.29.
Thermal Conductivity:
k = (Btu)(inch) = W = Btu (hr)(ft3)(oF) (m)(K) (hr)(ft)(oF)
Step (a): Use formula above to convert specifi cation to R-value. R = 1/k x T = 1/0.84 x .75 = 0.893.
Step (c): Compare proposed system R of 1.231 to specifi ed R of 0.893. Since proposed system R is greater than required, the system is acceptable.
Thermal Resistance:
R = (ft2)(hr)(oF) = (m2)(K) Btu W


These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then screwed into the fl ue liner.

3a) Full Flue Liner (No Cleanout Required)
The insert must be installed as per the require- ments of your local inspection authority. Three methods of fl ue connection are acceptable in most areas in the US, however a full fl ue liner is required in Canada.
required, by your inspector, to be installed when either the Positive fl ue connection or Direct fl ue connection method is used.
The use of one of the connection methods listed on this page not only increases the safety of your insert by directing the hot gases up the fl ue, but will also help increase the unit's effi ciency and decrease creosote deposits in the chimney.
When a connected fl ue or liner is in use, the insert is able to “breathe” better by allowing a greater draft to be created. The greater draft can decrease problems such as, diffi cult start-ups, smoking out the door, and dirty glass.
Solid-fuel Inserts in Factory-built Fire- places" section for the requirements for installing solid fuel inserts in factory built fi replaces.
Regency highly recommends the use of a full liner as the safest installation and provides the most optimum performance. Your retailer should be able to help you decide which system would be the best for your application.
Flush Inserts

Prior to sliding your insert into its fi nal position and attaching the connector or liner pipe, the faceplate side panel plates must be installed as follows:
tion, faceplate top and faceplate trim with the unit pulled slightly away from the fi replace face. If this is done, be very careful not to disturb the con- nector when shifting the unit to its fi nal position.
Now that your insert is installed, check once more that all the clearances from the unit to any combustible materials are correct as listed earlier.


OF THE FAN/BLOWER
Your fan should only be installed once the unit is in place in order to prevent any damage to the fan. To attach, follow the instructions provided with the fan. Make sure to install the rubber grommet to the fan housing before it is installed on the insert.
Do not turn fan ON until your insert has reached operating temperature or at least 30 minutes after starting fi re.




Blower/Fan Wiring Diagram

ensure the tube will not move when the unit is burning. Though there are four air tubes in the medium units.
Please check to ensure that your fl oor protection and hearth will meet the standards for clearance to combustibles. Your hearth extension must be made from a non-combustible material.
Before establishing your fi rst fi re, it is important that your fully understand the operation of you draft control. The draft rod is on the left side of the Inserts and it controls the intensity of the fi re by increasing or decreasing the amount of air allowed into the fi rebox. To increase your draft - pull open, and to decrease - push closed.
Firebrick is included to extend the life of your insert and radiate heat more evenly. Check to see that all fi rebricks are in their correct posi- tions and have not become misaligned during shipping.
Pull Open Push Closed
As well as a primary and glass wash air system, the unit has a full secondary draft system that allows air to the induction ports at the top of the fi rebox, just below the fl ue baffl e.
Hook screen to the inside on the right side of the fi rebox door opening. Lock in place by turning handle.

The fl ue baffl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier. The baffl es must be installed prior to your fi rst fi re. Smoke spill- age and draft problems may occur if the baffl es are improperly positioned. Check the position of the baffl es on a regular basis as they can be dislodged if too much fuel is forced into the fi rebox.
Back Side of Screen Shown
The unit arrives with the 2 baffl e plates on the fl oor of the fi rebox.
Attach spring handle by rotating counter clock- wise onto rod. Ensure that the rod fi ts into the entire length of the spring handle.
1) If all 4 air tubes are installed continue on to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door. Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side. Use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fi t will

Handle at 10 o'clock position.

SOME SAFETY
GUIDELINES
When your installation is completed and in- spected, you are ready for your fi rst fi re.
It is very important to carefully maintain your insert, including burning seasoned wood and maintaining a clean stove and chimney system. Have the chimney cleaned before the burning season and as necessary during the season, as creosote deposits may build up rapidly. Moving parts of your insert require no lubrication.
When operated with doors open the manufacturer supplied screen must be used.

CREOSOTE
During constant use, ashes should be removed every few days. Please take care to prevent the build-up of ash around the start-up air housing located inside the fi rebox, under the loading door lip.
When wood is burned slowly, it produces tar and other organic vapors, which form creosote when combined with moisture. The creosote vapors condense in the relatively cool chimney fl ue of a slow-burning fi re. As a result, creosote residue accumulates on the fl ue lining. When ignited, this creosote can make an extremely hot fi re.
DO NOT ALLOW ASHES TO BUILD UP TO THE LOADING DOORS.
Only remove ashes when the fi re has died down. Even then, expect to fi nd a few hot embers. Always leave 1 to 2 inches of ash in the bottom of the fi rebox. This helps in easier starting and a more uniform burn of your fi re.
Removal of your insert for cleaning purposes is usually not required if a proper installation has been done. In the event that removal is re- quired, be sure not to damage any parts needed for re-installation. In most cases removal and replacement of the baffl e system should allow full access for cleaning.
Ashes should be placed in a metal container with a tight fi tting lid. The closed container of ashes should be placed on a noncombustible fl oor or on the ground, well away from all combustible materials, pending fi nal disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste should not be placed in the ash container.
FAN OPERATION
The fan is to be operated only with the draft control rod pulled out at least 1/2" from the fully closed position. The fan is not to be oper- ated when the draft control rod is in the closed position (pushed in). The fully closed position is the low burn setting.
The fan unit must not be turned on until a fi re has been burning for at least 30 minutes and the unit is hot enough. As well, after each fuel loading the fan must be shut off until 30 minutes has elapsed.
To operate fan automatically, push switch on side of fan housing to "Auto" and second switch to either "High" or "Low" for fan speed. The automatic temperature sensor will engage the blower when the unit is at temperature and will shut off the blower once the fi re has gone out and the unit has cooled to below a useful heat output range.
To manually operate the fan system, push the fi rst switch to "Man" and second switch to either "high" or "Low". This will bypass the sensing device and allow full control of the fan. Switching from "Auto" to "Manual" or "High" to "Low" may be done at any time.
Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap plywood etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process.

MAINTENANCE OF GOLD-PLATED DOORS
GLASS CLEANING
Only clean your glass window when it is cool. Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits.
The gold electroplated fi nish on the doors requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

Your Regency Insert is supplied with 5 mm. Neoceram ceramic glass (Part #846-304) that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact - purchase your replacement from an authorized Regency dealer only, and follow our step-by-step instructions.
If the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Regency dealer.
DOOR LATCH ADJUSTMENT
Allow the stove to cool before removing or replac- ing glass. Remove the door from the insert and remove the glass retainer. Use caution when removing broken glass to prevent injury.
The door latch may require adjustment as the door gasket material compresses after a few fi res. Removal of the spacer washer, shown in the diagram below, will allow the latch to be moved closer to the door frame, causing a tighter seal. Remove and replace the nuts, washer as shown.
When placing the replacement glass in the door, make sure that the glass gasketing will properly seal your unit. Replace the retainer and tighten securely, but do not wrench down on the glass as this may cause breakage. Do not substitute materials. If your glass door does break, do not continue to use your unit until it has been replaced.

Avoid impact on glass doors such as striking or slamming shut.

MAIN ASSEMBLY & OPTIONS - I2400M
142-917 Fan Assembly 24) 910-157/P Fan Motor 120 Volts 25) 910-678 Power Cord 120 Volts 27) 910-142 Fan Thermodisc 28) 910-140 Fan Speed Hi / OFF / Low Switch (3-way) 29) 910-138 Auto / Manual On / OFF Switch 30) * Grommet Strain Relief 36) 033-953 Air Tube 3/4" (Qty:4) 37) 020-957 Baffl e (2/set)
*Not available as a replacement part.

Part # Description · Part # Description · Part # Description

BRICK PANELS - I2400M
Part # Description

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
Firebox, ceramic baffl e, vermiculite baffl e, convector airmate, castings, ashdrawer, glass (thermal breakage) gold plating (against defective manufacture), airtubes (against warpage) and door handles.
Special Finishes - One year on brushed nickel, louvers and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, i.e.. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
The above will be covered for parts and subsidized labour for the fi rst fi ve years and parts only thereafter with the exception of the fi reboxes (see below).
FPI is not liable for freight or labor on any wood burning appliance replaced in fi eld.
Electrical components such as blowers, switches and thermodisc's are covered for one year from the date of purchase.
Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect.
The authorized selling dealer is responsible for all in-fi eld service work carried out on your Excalibur product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing, fi rebrick or trim. It does not cover installation and operational related problems such as over-fi ring, use of corrosive driftwood, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures caused by mechanical systems such as furnaces, fans, clothes dryers etc.
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. i.e. as products evolve, fi eld modifi cations or upgrades will not be performed.
FPI will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse.
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Excalibur, may nullify your warranty on this product.
* Subsidy according to job scale as predetermined by FPI.


with reliability and simplicity in mind. In
addition, our internal Quality Assur-



unit thoroughly before it leaves our
door.
Fireplace Products Interna- tional Ltd. is pleased to extend this Limited Lifetime Warranty to the origi- nal purchaser of a Regency Product.
See the inside back cover for details.
http://www.regency-fi re.com
Dealer Name & Address: ______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: __________________________________________________________
Regency and Classic are trademarks of FPI Fireplace Products International Ltd.