EN
Regency Wraps logo
Official user manual

Regency Wraps Wood Fireplace Insert (I2400M)

20 pages·850 KB·Indoor Fireplace·PDF·ENDEFRITNLJA
Regency Wraps Wood Fireplace Insert (I2400M)
Table of Contents 75 sections WOOD Fireplace · Insert · www.regency-fi re.com · Owners & Installation Manual · … ShowHide
WOOD Fireplacep.1Insertp.1www.regency-fi re.comp.1Owners & Installation Manualp.1MODELS: I2400Mp.1Installer : Please complete the details on the back coverp.1SAFETY LABELp.4SAFETY LABEL FOR I2400Mp.4MANUFACTUREp.4DATE OFp.4SIGNATUREp.4DO NOT TOUCH. KEEP CHILDREN,p.46988 VENTURE ST., DELTA, BC V4G 1H4p.4HOT WHILE IN OPERATIONp.4CAUTIONp.4DO NOT REMOVE THIS LABELp.4LISTED FACTORY BUILT FIREPLACE INSERTp.4REPORT NO.: 219-S-03-2p.4MODEL: I2400Mp.4UNIT DIMENSIONSp.5CHIMNEY SPECIFICATIONSp.6BEFORE INSTALLINGp.6YOUR INSERTp.6Requirements for Installing Solid-fuel Inserts in Factory-builtp.6WOOD INSERT SPECIFICATIONSp.6INSTALLING YOURp.7Convection Grillsp.7MASONRY AND FACTORY BUILT FIREPLACE CLEARANCESp.8HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLEp.8DEFINITIONSp.8INSTALLATION INTO A MASONRY FIREPLACEp.9STEP-BY-STEP INSTALLATION OF THE FACEPLATE AND TRIMp.10STEP-BY-STEP INSTALLATIONp.11OF THE FAN/BLOWERp.11FLOOR PROTECTIONp.12DRAFT CONTROLp.12FIREBRICK ASSEMBLYp.12SCREEN DOORp.12FLUE BAFFLE & SECONDARY AIR TUBEp.12DOOR HANDLEp.12OPERATING INSTRUCTIONSp.13FIRST FIREp.13SOME SAFETYp.13GUIDELINESp.13ASH DISPOSALp.14CREOSOTEp.14Removal for Cleaningp.141) Close draft control 2) Call the Fire Departmentp.14Ways to Prevent and Keep Unit Free of Creosotep.14FAN OPERATIONp.14WOOD STORAGEp.14MAINTENANCEp.15MAINTENANCE OF GOLD-PLATED DOORSp.15GLASS CLEANINGp.15GLASS REMOVALp.15DOOR LATCH ADJUSTMENTp.15PARTS LISTp.16MAIN ASSEMBLY & OPTIONS - I2400Mp.16BRICK PANELS - I2400Mp.18WARRANTYp.19Regency fi replace products are designedp.20with reliability and simplicity in mind. Inp.20addition, our internal Quality Assur-p.20ance Team carefully inspects eachp.20unit thoroughly before it leaves ourp.20Register your Regency online atp.20http://www.regency-fi re.comp.20Installer: Please complete the following informationp.20Dealer Name & Address: ______________________________________________p.20___________________________________________________________________p.20Installer: ___________________________________________________________p.20Phone #: ___________________________________________________________p.20Date Installed: ______________________________________________________p.20Serial No.: __________________________________________________________p.20Printed in Canadap.20
Page 1 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — Installer : Please complete the details on the back cover
Page 1 · click to enlarge
Page 1

WOOD Fireplace

Insert

www.regency-fi re.com

Owners & Installation Manual

Regency Wraps Wood Fireplace Insert (I2400M) — www.regency-fi re.com diagram (page 1)
Fig. 1 · www.regency-fi re.com

MODELS: I2400M

Tested by:

Installer : Please complete the details on the back cover

and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-171a

07/18/06

Page 2 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — WOOD Fireplace
Page 2 · click to enlarge
Page 2

Thank-you for purchasing a REGENCY FIREPLACE PRODUCT.

The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.

Keep those REGENCY FIRES burning.

SAFETY NOTE: If this Insert is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building, fi re offi cials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.

The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.

Regency Wraps Wood Fireplace Insert (I2400M) — WOOD Fireplace diagram (page 2)
Fig. 2 · WOOD Fireplace
Page 3 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — WOOD Fireplace
Page 3 · click to enlarge
Page 3
Page 3 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — WOOD Fireplace
Page 4 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — REPORT NO.: 219-S-03-2
Page 4 · click to enlarge
Page 4

SAFETY LABEL

SAFETY LABEL FOR I2400M

(Duplicate Serial #) 246

This is a copy of the label that accompanies your Regency Insert. We have printed a copy of the contents here for your review.

Jan Feb Mar Apr May June

July Aug Sept Oct Nov Dec

MANUFACTURE

DATE OF

SIGNATURE

MANUFACTURED BY FPI LTD.

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH July 1990, PARTICULATE EMISSION STANDARDS.

DO NOT TOUCH. KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY.

CONTACT MAY CAUSE SKIN BURNS.

FIREPLACE PRODUCTS INTERNATIONAL LTD.

6988 VENTURE ST., DELTA, BC V4G 1H4

MADE IN CANADA 918-176b

HOT WHILE IN OPERATION

READ ABOVE INSTRUCTIONS.

CAUTION

Manufactured By:

DO NOT REMOVE THIS LABEL

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY

FIREPLACE OR FACTORY BUILT FIREPLACE. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN

TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE

A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE MANUFACTURER SUPPLIED SCREEN

INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 0.5IN / 13MM ABOVE AN

ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-

COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN / 457 MM TO FRONT AND (G) 8 IN / 205 MM

OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. IF INSTALLED IN

MUST BE USED. REPLACE GLASS ONLY WITH CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY

TO SIDES FROM FUEL DOOR. 0.5" FLOOR PROTECTION NEEDS TO BE WITH k=0.84.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)

THE I2400M MEETS UL 737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.

OPTIONAL COMPONENTFAN (142-917), ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS, SCREEN DOOR (846-102)

LISTED FACTORY BUILT FIREPLACE INSERT

CERTIFIED FOR USE IN CANADA AND U.S.A.

TESTED TOULC S628 / UL 1482 / UL 737

COMPONENTS REQUIRED FOR INSTALLATION: 6IN / 150MM STAINLESS STEEL LINER.

OCCUR RAPIDLY. DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.

REPORT NO.: 219-S-03-2

MODEL: I2400M

ADJACENT SIDEWALL A) 11 in / 280 mm

MANTLE B) 20 in / 508 mm

TOP FACING C) 12 in / 305 mm

SIDE FACING D) 8 in / 200 mm

YOUR AREA.

Page 5 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — UNIT DIMENSIONS
Page 5 · click to enlarge
Page 5

UNIT DIMENSIONS

Regency Wraps Wood Fireplace Insert (I2400M) — UNIT DIMENSIONS diagram (page 5)
Fig. 3
Regency Wraps Wood Fireplace Insert (I2400M) — UNIT DIMENSIONS diagram (page 5)
Fig. 4
Regency Wraps Wood Fireplace Insert (I2400M) — UNIT DIMENSIONS diagram (page 5)
Fig. 5
Page 6 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — WOOD INSERT SPECIFICATIONS
Page 6 · click to enlarge
Page 6

Regency Inserts are constructed with the high- est quality materials and assembled under strict quality control procedures that insure years of trouble free and reliable performance.

CHIMNEY SPECIFICATIONS

7. Alteration of the fi replace in any manner is not permitted with the following exceptions; a. external trim pieces which do not affect

the operation of the fi replace may be removed providing they can be stored on or within the fi replace for re-assembly if the insert is removed.

Before installing, check and clean your chimney system thoroughly. If in doubt about its condi- tion, seek professional advice. Your Regency Insert is designed for installation into a masonry fi replace that is constructed in accordance with the requirements of "The Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Ap- pliance", N.F.P.A. 211, the National Building Code of Canada, or the applicable local code requirements.

It is important that you read this manual thor- oughly and fully understand the safe instal- lation and operating procedures. The more you understand the way your Regency Insert operates, the more enjoyment you will experi- ence from knowing that your unit is operating at peak performance.

b. the chimney damper may be removed

to install the chimney liner.

8. Circulating air chambers (i.e. in a steel fi replace liner or metal heat circulator) shall not be blocked.

BEFORE INSTALLING

9. Means must be provided for removal of the insert to clean the chimney fl ue.

The appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.

YOUR INSERT

10. Inserts that project in front of the fi replace must be supplied with appropriate supporting means.
1. Please read this entire manual before you install and use your new wood insert. Failure to follow instructions may result in property damage, bodily injury or even death. Install and use only in accordance with manufacturer’s installation and operating instructions.

Regency Inserts are designed with a 6" (152mm) fl ue.

11. Installer must mechanically attach the supplied label to the inside of the fi rebox of the fi replace into which the insert is installed.

Requirements for Installing Solid-fuel Inserts in Factory-built

2. Check your local building codes - Building Inspection Department. You may require a permit before installing your insert. Be aware that local codes and regulations may override some items in the manual.

Fireplaces.

"WARNING: This fi replace has been converted for use with a wood insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fi replace re-approved by the authority having jurisdiction."

1. The insert must be tested and meet the requirements of UL 1482 (U.S.) and or ULC S628 (Canada) when tested in a masonry fi replace built per ULC S628.
2. The factory-built fi replace must be listed per UL 127 or ULC S610.

In order for a solid-fuel insert to be certifi ed for use in factory-built fi replaces, the above information must be clearly stated in the instal- lation manual and appropriate markings. Final approval is contingent on the authority having jurisdiction.

3. Notify your home insurance company that you plan to install a fi replace insert or hearth heater.
3. Clearances obtained from the masonry fi replace tests are also relevant for installation in factory-built fi replaces.
4. Your fi replace insert is heavy and requires two or more people to move it safely. The insert can be badly damaged by mishandling.
4. Installation must include a full height listed chimney liner type HT requirements (2100 degree F.) per UL 1777 (U.S.) or ULC S635 (Canada). The liner must be securely attached to the insert fl ue collar and the chimney top.

WOOD INSERT SPECIFICATIONS

5. If your existing fi replace damper control will become inaccessible once you have installed your Regency Insert, you should either remove or secure it in the open position.

Your fi replace opening requires the following minimum sizes:

5. Means must be provided to prevent room air passage to the chimney cavity of the fi replace. This may be accomplished by sealing the damper area around the chimney liner, or sealing the fi replace front.
6. Inspect your fi replace and chimney prior to installing your insert to determine that it is free from cracks, loose mortar or other signs of damage. If repairs are required, they should be completed before installing your insert. Do not remove bricks or mortar from your masonry fi replace.
Height21.5" Width: 25" Depth: 17"
6. The air fl ow within and around the fi replace shall not be altered by the installation of the insert (i.e. no louvers or cooling air or outlet ports are blocked), unless specifi cally tested as such for each factory-built fi replace manufacturer and model line. Note : using a louvered faceplate (surround) complies with this requirement.

Two faceplates are available to seal the fi replace opening:

Standard Oversize 40" W x 30" H 48" W x 33" H

7. Do not connect the insert to a chimney system servicing another appliance or an air distribution duct.

Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.

Page 7 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — Convection Grills
Page 7 · click to enlarge
Page 7

INSTALLING YOUR

Regency Wraps Wood Fireplace Insert (I2400M) — INSTALLING YOUR diagram (page 7)
Fig. 6

INSERT

Your insert is very heavy and will require two or three people to move it into position. The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges. Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation.

The Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your fl ue connector and the insert collar. Detailed installation instructions are included with the kit.

Convection Grills

The convection grills are installed before the unit is positioned inside the fi replace.

Position the grill on the inside bodyface side and fasten using the bolts, washers and nuts provided (2 per side) as shown in the diagrams.

View from Rear of Insert

on the front side have rounded edges and the rear holes have fl at edges.

Page 8 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — DEFINITIONS
Page 8 · click to enlarge
Page 8

MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES

The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below.

UnitAdjacent Side Wall (to Side) AMantle** (to Top) BTop Facing (to Top) CSide Facing (to Side) DMinimum Hearth Extension* EMinimum Hearth Thickness* F Medium Flush Insert (I2400)11"/280mm20"/508mm12"/305mm8"/200mm18"/455mm0.5"/13mm

Side and Top facing is a maximum of 1.5" thick. Floor protection must be non-combustible, insula- tive material with an R value of 1.1 or greater.

* Hearth thickness of 0.5" with k value = 0.84", R value = 6 or greater.

** A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

** Max. mantle depth is 10" (254mm).

Thermal fl oor protection is not required if the unit is raised 3.5" minimum (measured from the bottom of the stove). However, standard ember fl oor protec- tion is required. It will need to be a non-combustible material that covers 16" (406 mm) in the US and 18" (450 mm) in Canada to the front of the unit and 8" (200 mm) to the sides.

If the unit is not raised, thermal fl oor protection required is 18" (450 mm) in the US and Canada.

Clearance diagram for Installations

All fl oor protection must be non-combustible (i.e., metals, brick, stone, mineral fi ber boards, etc.) Any organic materials (i.e. plastics, wood paper prod- ucts, etc.) are combustible and must not be used. The fl oor protection specifi ed includes some form of thermal designation such as R-value (thermal resistance) or k-factor (thermal conductivity).

Minimum Hearth Extension for the front (E) and sides (G) are measured from the

fuel door opening.

HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE

DEFINITIONS

The specifi ed fl oor protector should be 3/8" (18mm) thick material with a K - factor of 0.84.

Step (b): Calculate R of proposed system. 4" brick of C = 1.25, therefore Rbrick = 1/C = 1/1.25 = 0.80 1/8" mineral board of k = 0.29, therefore Rmin.bd. = 1/0.29 x 0.125 = 0.431 Total R = Rbrick + Rmineral board = 0.8 + 0.431 = 1.231.

Thermal Conductance:

C = Btu = W (hr)(ft2 )(oF) (m2))(K)

The proposed alternative is 4" (100mm) brick with a C-factor of 1.25 over 1/8" (3mm) mineral board with a K-factor of 0.29.

Thermal Conductivity:

k = (Btu)(inch) = W = Btu (hr)(ft3)(oF) (m)(K) (hr)(ft)(oF)

Step (a): Use formula above to convert specifi cation to R-value. R = 1/k x T = 1/0.84 x .75 = 0.893.

Step (c): Compare proposed system R of 1.231 to specifi ed R of 0.893. Since proposed system R is greater than required, the system is acceptable.

Thermal Resistance:

R = (ft2)(hr)(oF) = (m2)(K) Btu W

Page 9 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — INSTALLATION INTO A MASONRY FIREPLACE
Page 9 · click to enlarge
Page 9
Regency Wraps Wood Fireplace Insert (I2400M) — INSTALLATION INTO A MASONRY FIREPLACE diagram (page 9)
Fig. 7

These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then screwed into the fl ue liner.

1. When installed in a factory built fi replace, a full stainless steel rigid or fl exible fl ue liner is mandatory, for both safety and performance purposes. When a fl ue or liner is in use, the insert is able to breathe better by allowing a greater draft to be created. The greater draft can decrease problems such as, diffi cult start-ups, smoking out the door, and dirty glass.
1. Positive Flue Connection with Cleanout
2. Direct Flue Connection with Cleanout
Regency Wraps Wood Fireplace Insert (I2400M) — INSTALLATION INTO A MASONRY FIREPLACE diagram (page 9)
Fig. 8
2. In order to position the fl ue liner, the existing rain cap must be removed from your chimney system. In most cases the fl ue damper should also be removed to allow passage of the liner.
3. In most cases opening the existing spark screens fully should give enough room for the insert installation. If it does not, remove and store.
4. If the fl oor of your fi replace is below the level of the fi replace opening, adjust the insert's levelling bolts to accommodate the difference. When additional shimming is required, use non-combustible masonry or steel shims.

INSTALLATION INTO A MASONRY FIREPLACE

3a) Full Flue Liner (No Cleanout Required)

The insert must be installed as per the require- ments of your local inspection authority. Three methods of fl ue connection are acceptable in most areas in the US, however a full fl ue liner is required in Canada.

required, by your inspector, to be installed when either the Positive fl ue connection or Direct fl ue connection method is used.

5. Measure approximately the alignment of the fl ue liner with the position of the smoke outlet hole on the insert to check for possible offset. If an offset is required, use a proper stainless steel unit available with the chimney liner.
1. Positive fl ue connection, where a large blocking plate and a short connector pipe is used.

The use of one of the connection methods listed on this page not only increases the safety of your insert by directing the hot gases up the fl ue, but will also help increase the unit's effi ciency and decrease creosote deposits in the chimney.

6. Once the above items have been checked, slide your insert into position after fi rst positioning the fl ue liner and offset if required. (Re-install raincap at completion of installation).
2. Direct fl ue connection, where a smaller blocking plate and a connector pipe to the fi rst fl ue liner tile is used.
3. Full fl ue liner, where a stainless steel rigid or fl exible liner pipe is routed from the insert outlet collar to the top of the chimney.

When a connected fl ue or liner is in use, the insert is able to “breathe” better by allowing a greater draft to be created. The greater draft can decrease problems such as, diffi cult start-ups, smoking out the door, and dirty glass.

Solid-fuel Inserts in Factory-built Fire- places" section for the requirements for installing solid fuel inserts in factory built fi replaces.

Regency highly recommends the use of a full liner as the safest installation and provides the most optimum performance. Your retailer should be able to help you decide which system would be the best for your application.

Flush Inserts

Page 10 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — STEP-BY-STEP INSTALLATION OF THE FACEPLATE AND TRIM
Page 10 · click to enlarge
Page 10

STEP-BY-STEP INSTALLATION OF THE FACEPLATE AND TRIM

Prior to sliding your insert into its fi nal position and attaching the connector or liner pipe, the faceplate side panel plates must be installed as follows:

tion, faceplate top and faceplate trim with the unit pulled slightly away from the fi replace face. If this is done, be very careful not to disturb the con- nector when shifting the unit to its fi nal position.

1. Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts may need to be squeezed with a pair of pliers fi rst, to help them stay in position).

Now that your insert is installed, check once more that all the clearances from the unit to any combustible materials are correct as listed earlier.

Regency Wraps Wood Fireplace Insert (I2400M) — STEP-BY-STEP INSTALLATION OF THE FACEPLATE AND TRIM diagram (page 10)
Fig. 9
2. Screw the side faceplate panels, (item A in the diagram) one to each side.
3. Using the top panel (item B in the diagram) as a gauge, check that the side panels are within approximately 1/4" of the overall width. If the difference is greater than this, use the supplied washers to attain the required width.
4. The unit may now be slid into fi nal position and attached to the connection system.
5. Once connection is made, the insulation strips should be installed between the insert faceplates and the fi replace face. The faceplate top may now be installed (with insulation strip behind) by aligning its brackets with the top fl ange on the side shields and the angle iron bar on the insert top. The faceplate trim may be installed to the edge of the faceplate at this time.
Page 11 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — STEP-BY-STEP INSTALLATION
Page 11 · click to enlarge
Page 11

STEP-BY-STEP INSTALLATION

OF THE FAN/BLOWER

Your fan should only be installed once the unit is in place in order to prevent any damage to the fan. To attach, follow the instructions provided with the fan. Make sure to install the rubber grommet to the fan housing before it is installed on the insert.

3. Slide the supports into the clips. The tension holding the clips in place may be adjusted by increasing or decreasing the offset spacing of the clips.

Do not turn fan ON until your insert has reached operating temperature or at least 30 minutes after starting fi re.

4. Ensure that the power cord is not in contact with any hot stove surfaces.
1. Remove the protective covering from the brass trim on the fan.
2. Align the fan support with the offset clip on the bottom of the ashlip.
Regency Wraps Wood Fireplace Insert (I2400M) — STEP-BY-STEP INSTALLATION diagram (page 11)
Fig. 10
Regency Wraps Wood Fireplace Insert (I2400M) — STEP-BY-STEP INSTALLATION diagram (page 11)
Fig. 11
Regency Wraps Wood Fireplace Insert (I2400M) — STEP-BY-STEP INSTALLATION diagram (page 11)
Fig. 12
Regency Wraps Wood Fireplace Insert (I2400M) — STEP-BY-STEP INSTALLATION diagram (page 11)
Fig. 13

Blower/Fan Wiring Diagram

Page 12 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — DOOR HANDLE
Page 12 · click to enlarge
Page 12

FLOOR PROTECTION

ensure the tube will not move when the unit is burning. Though there are four air tubes in the medium units.

DRAFT CONTROL

Please check to ensure that your fl oor protection and hearth will meet the standards for clearance to combustibles. Your hearth extension must be made from a non-combustible material.

Before establishing your fi rst fi re, it is important that your fully understand the operation of you draft control. The draft rod is on the left side of the Inserts and it controls the intensity of the fi re by increasing or decreasing the amount of air allowed into the fi rebox. To increase your draft - pull open, and to decrease - push closed.

2. Slide the left baffl e over the air tubes from the front and then push it to the back.

FIREBRICK ASSEMBLY

Firebrick is included to extend the life of your insert and radiate heat more evenly. Check to see that all fi rebricks are in their correct posi- tions and have not become misaligned during shipping.

Pull Open Push Closed

3. Tilt the left baffl e up on top of the side channel and it will leave enough room to position the right baffl e in the same manner as Step 1) above. Then reposition the left baffl e fl at on the air tubes.

As well as a primary and glass wash air system, the unit has a full secondary draft system that allows air to the induction ports at the top of the fi rebox, just below the fl ue baffl e.

SCREEN DOOR

Hook screen to the inside on the right side of the fi rebox door opening. Lock in place by turning handle.

Regency Wraps Wood Fireplace Insert (I2400M) — SCREEN DOOR diagram (page 12)
Fig. 14
4. Important: push both baffl es so they are tight against the side walls.

FLUE BAFFLE & SECONDARY AIR TUBE

The fl ue baffl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier. The baffl es must be installed prior to your fi rst fi re. Smoke spill- age and draft problems may occur if the baffl es are improperly positioned. Check the position of the baffl es on a regular basis as they can be dislodged if too much fuel is forced into the fi rebox.

Back Side of Screen Shown

DOOR HANDLE

The unit arrives with the 2 baffl e plates on the fl oor of the fi rebox.

Attach spring handle by rotating counter clock- wise onto rod. Ensure that the rod fi ts into the entire length of the spring handle.

1) If all 4 air tubes are installed continue on to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door. Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side. Use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fi t will

Regency Wraps Wood Fireplace Insert (I2400M) — DOOR HANDLE diagram (page 12)
Fig. 15

Handle at 10 o'clock position.

Show 4 more labels / short text on this page
Side View · Front View · Handle Lock Hooks · Front View
Page 13 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — FIRST FIRE
Page 13 · click to enlarge
Page 13

OPERATING INSTRUCTIONS

13. Do not store any fuel closer than 2 feet from your unit.

FIRST FIRE

SOME SAFETY

GUIDELINES

When your installation is completed and in- spected, you are ready for your fi rst fi re.

14. Do not burn salt drift wood as it will corrode your unit and void the warranty.
1. Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or ‘freshen up’ a fi re in your heater. Keep all such liquids well away from the heater while it is in use.
1. Open draft control fully.
15. Do not operate the unit if the glass is broken or missing. Do not operate the unit if the gasketing is worn out and not sealing the door or the glass.
2. Open fi rebox door and build a small fi re using paper and dry kindling on the fi rebrick hearth, wait a few minutes for a good updraft in the fl ue to establish the fi re. Leaving the door slightly open will help your fi re start more rapidly.
2. Keep the door closed during operation and maintain all seals in good condition.

It is very important to carefully maintain your insert, including burning seasoned wood and maintaining a clean stove and chimney system. Have the chimney cleaned before the burning season and as necessary during the season, as creosote deposits may build up rapidly. Moving parts of your insert require no lubrication.

3. Do not burn large quantities of paper in your insert.
4. If you have smoke detectors, prevent smoke spillage as this may set off a false alarm.
5. Do not overfi re your insert. If the insert begin to glow, you are overfi ring. Stop adding fuel and close the draft control. Overfi ring can cause extensive damage to your stove including warpage and premature steel corrosion. Overfi ring will void your warranty.
3. With the draft still in the fully open position, add two or three seasoned logs to your fi re. Form a trench in the ash bed to allow air to reach the rear of the fi rebox prior to closing the door.
6. Do not permit creosote or soot buildup in the chimney system. Check and clean chimney at regular intervals.
4. After about 15 to 20 minutes, when your wood has begun to burn strongly, adjust your draft control down to keep the fi re at a moderate level.

When operated with doors open the manufacturer supplied screen must be used.

7. Your Regency Insert can be very hot. You may be seriously burned if you touch the insert while it is operating. Warn children of the burn hazard.
8. The insert consumes air while operating, provide adequate ventilation with an air duct or open a window while the insert is in use.
5. Once a bed of coals has been established, you may adjust the draft control to a low setting to operate the unit in its most effi cient mode.
9. Do not use grates, irons or other methods for supporting fuel. Burn directly on the bricks.
6. During the fi rst couple of hours, keep the combustion rate at a moderate level and avoid a large fi re until the paint is cured. Only then can you operate the insert at its maximum setting, and only after the metal has been warmed.
10. Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fi re.
11. Do not connect your unit to any air distribution duct.
7. For the fi rst few hours, the insert will give off an odor from the paint. This is to be expected as the high temperature paint becomes seasoned. Windows and/or doors should be left open to provide adequate ventilation while this temporary condition exists. Burning the insert at a very high temperature the fi rst few times may damage the paint. Burn fi res at a moderate level the fi rst few days.
12. Your insert should burn dry, standard fi rewood only. The use of “mill ends” is discouraged as this fuel can easily overheat your insert. Evidence of excessive overheating will void your warranty. As well, a large portion of sawmill waste is chemically treated lumber, which is illegal to burn in many areas. Chemically treated fi re logs also must not be burned in your insert.
8. Do not place anything on the insert top during the curing process. This may result in damage to your paint fi nish.
Page 14 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — WOOD STORAGE
Page 14 · click to enlarge
Page 14

OPERATING INSTRUCTIONS

9. During the fi rst few hours it may be more diffi cult to start the fi re. As you dry out your fi re brick and your masonry fl ue (if applicable), your draft will increase.

ASH DISPOSAL

CREOSOTE

During constant use, ashes should be removed every few days. Please take care to prevent the build-up of ash around the start-up air housing located inside the fi rebox, under the loading door lip.

When wood is burned slowly, it produces tar and other organic vapors, which form creosote when combined with moisture. The creosote vapors condense in the relatively cool chimney fl ue of a slow-burning fi re. As a result, creosote residue accumulates on the fl ue lining. When ignited, this creosote can make an extremely hot fi re.

10. For those units installed at higher elevations or into sub-standard masonry fi replaces, drafting problems may occur. Consult an experienced dealer or mason on methods of increasing your draft.

DO NOT ALLOW ASHES TO BUILD UP TO THE LOADING DOORS.

11. Some cracking and popping noises may be experienced during the heating up process. These noises will be minimal when your unit reaches temperature.

Only remove ashes when the fi re has died down. Even then, expect to fi nd a few hot embers. Always leave 1 to 2 inches of ash in the bottom of the fi rebox. This helps in easier starting and a more uniform burn of your fi re.

Removal for Cleaning

Removal of your insert for cleaning purposes is usually not required if a proper installation has been done. In the event that removal is re- quired, be sure not to damage any parts needed for re-installation. In most cases removal and replacement of the baffl e system should allow full access for cleaning.

12. Before opening your door to reload, open draft fully for approximately 10 to 15 seconds until fi re has been re-established. This will minimize any smoking.

Ashes should be placed in a metal container with a tight fi tting lid. The closed container of ashes should be placed on a noncombustible fl oor or on the ground, well away from all combustible materials, pending fi nal disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste should not be placed in the ash container.

13. All fuel burning appliances consume oxygen during operation. It is important that you supply a source of fresh air to your unit while burning. A slightly opened window is suffi cient for this purpose.

1) Close draft control 2) Call the Fire Department

Ways to Prevent and Keep Unit Free of Creosote

FAN OPERATION

The fan is to be operated only with the draft control rod pulled out at least 1/2" from the fully closed position. The fan is not to be oper- ated when the draft control rod is in the closed position (pushed in). The fully closed position is the low burn setting.

1. Burn insert with draft control wide open for about 45 minutes every morning during burning season. This helps to prevent creosote deposits within the heating system.
14. Green or wet wood is not recommended for your unit. If you must add wet or green fuel, open the draft control fully until all moisture has been dispersed by the intense fi re. Once all moisture has been removed, the draft control may be adjusted to maintain the fi re.
2. Burn insert with draft control wide open for about 10 - 15 minutes every time you add fresh wood. This allows the wood to achieve the charcoal stage faster and burns up any wood vapors which might otherwise be deposited within the system.

The fan unit must not be turned on until a fi re has been burning for at least 30 minutes and the unit is hot enough. As well, after each fuel loading the fan must be shut off until 30 minutes has elapsed.

15. If you have been burning your insert on a low draft, use caution when opening the door. After opening the damper, open the door a crack, and allow the fi re to adjust before fully opening the door.
3. Only burn seasoned wood! Do not burn wet or green wood. Seasoned wood that has been dried at least one year must be used.

To operate fan automatically, push switch on side of fan housing to "Auto" and second switch to either "High" or "Low" for fan speed. The automatic temperature sensor will engage the blower when the unit is at temperature and will shut off the blower once the fi re has gone out and the unit has cooled to below a useful heat output range.

16. The controls of your unit should not be altered to increase fi ring for any reason.
4. A small hot fi re is preferable to a large smouldering one that can deposit creosote within the system.

WOOD STORAGE

5. Check the chimney at least twice a month during the burning season for creosote build-up.

To manually operate the fan system, push the fi rst switch to "Man" and second switch to either "high" or "Low". This will bypass the sensing device and allow full control of the fan. Switching from "Auto" to "Manual" or "High" to "Low" may be done at any time.

Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap plywood etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process.

6. Have chimney system and unit cleaned by competent chimney sweeps twice a year during the fi rst year of use and at least once a year thereafter or when a signifi cant layer of creosote has accumulated (3mm / 1/8" or more) it should be removed to reduce the risk of a chimney fi re.
Page 15 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — GLASS REMOVAL
Page 15 · click to enlarge
Page 15

MAINTENANCE

MAINTENANCE OF GOLD-PLATED DOORS

GLASS CLEANING

Only clean your glass window when it is cool. Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits.

The gold electroplated fi nish on the doors requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

Regency Wraps Wood Fireplace Insert (I2400M) — MAINTENANCE diagram (page 15)
Fig. 16

Your Regency Insert is supplied with 5 mm. Neoceram ceramic glass (Part #846-304) that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact - purchase your replacement from an authorized Regency dealer only, and follow our step-by-step instructions.

If the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Regency dealer.

GLASS REMOVAL

DOOR LATCH ADJUSTMENT

Allow the stove to cool before removing or replac- ing glass. Remove the door from the insert and remove the glass retainer. Use caution when removing broken glass to prevent injury.

The door latch may require adjustment as the door gasket material compresses after a few fi res. Removal of the spacer washer, shown in the diagram below, will allow the latch to be moved closer to the door frame, causing a tighter seal. Remove and replace the nuts, washer as shown.

When placing the replacement glass in the door, make sure that the glass gasketing will properly seal your unit. Replace the retainer and tighten securely, but do not wrench down on the glass as this may cause breakage. Do not substitute materials. If your glass door does break, do not continue to use your unit until it has been replaced.

Regency Wraps Wood Fireplace Insert (I2400M) — GLASS REMOVAL diagram (page 15)
Fig. 17

Avoid impact on glass doors such as striking or slamming shut.

Page 16 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — PARTS LIST
Page 16 · click to enlarge
Page 16

PARTS LIST

MAIN ASSEMBLY & OPTIONS - I2400M

1. 846-910 Door Assy - Large Gold (no glass) 846-916 Door Assy - Large Blk (no glass) 2) 846-304 Glass - Replacement 4) 936-243 7/8" Adhesive Tape Gasket 5) 846-920 Glass Retainer Clips (8/set) 6) * Screw 1/4-20 x 3/8" 7) 948-172/P Glass Retainer - Large 9) 846-973 Door Handle Assembly

142-917 Fan Assembly 24) 910-157/P Fan Motor 120 Volts 25) 910-678 Power Cord 120 Volts 27) 910-142 Fan Thermodisc 28) 910-140 Fan Speed Hi / OFF / Low Switch (3-way) 29) 910-138 Auto / Manual On / OFF Switch 30) * Grommet Strain Relief 36) 033-953 Air Tube 3/4" (Qty:4) 37) 020-957 Baffl e (2/set)

42. 163-932 Convection Grill - Gold (Opt) 163-930 Convection Grill - Blk (Opt) 43) * Hex Nut 10-24 Zinc Coated 44) * Washer #10 Flat 45) * Bolt, 10-24 x 3/4" Blk Carriage
47. 846-102 Screen Door 948-216 Regency Logo 918-171 Manual
16. 846-570 Door Gasket Kit 17) 846-918 Hinge Caps - Gold Plated (2/set) 19) 948-101 Spring Handle - Large 20) 948-102 Spring Handle - Small 23) 846-235 Flue Brackets Package

*Not available as a replacement part.

Regency Wraps Wood Fireplace Insert (I2400M) — PARTS LIST diagram (page 16)
Fig. 18

Part # Description · Part # Description · Part # Description

Page 18 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — PARTS LIST
Page 18 · click to enlarge
Page 18

PARTS LIST

BRICK PANELS - I2400M

70. 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 75) 802-122 Brick Partial: 1-1/4 x 4-1/2" x 2" 76) 802-152 Brick Partial: 1-1/4" x 2" x 9"

Part # Description

Page 19 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — WARRANTY
Page 19 · click to enlarge
Page 19

WARRANTY

Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.

The WarrantyLifetime Covered under the agreement are the following components:

Firebox, ceramic baffl e, vermiculite baffl e, convector airmate, castings, ashdrawer, glass (thermal breakage) gold plating (against defective manufacture), airtubes (against warpage) and door handles.

Special Finishes - One year on brushed nickel, louvers and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, i.e.. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

The above will be covered for parts and subsidized labour for the fi rst fi ve years and parts only thereafter with the exception of the fi reboxes (see below).

FPI is not liable for freight or labor on any wood burning appliance replaced in fi eld.

Electrical components such as blowers, switches and thermodisc's are covered for one year from the date of purchase.

Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Excalibur product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing, fi rebrick or trim. It does not cover installation and operational related problems such as over-fi ring, use of corrosive driftwood, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures caused by mechanical systems such as furnaces, fans, clothes dryers etc.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. i.e. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work.

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Excalibur, may nullify your warranty on this product.

* Subsidy according to job scale as predetermined by FPI.

Page 20 of the Regency Wraps Wood Fireplace Insert (I2400M) user manual — Printed in Canada
Page 20 · click to enlarge
Page 20
Regency Wraps Wood Fireplace Insert (I2400M) — Regency fi replace products are designed diagram (page 20)
Fig. 19 · Regency fi replace products are designed

Regency fi replace products are designed

with reliability and simplicity in mind. In

addition, our internal Quality Assur-

Regency Wraps Wood Fireplace Insert (I2400M) — Regency fi replace products are designed diagram (page 20)
Fig. 20 · Regency fi replace products are designed
Regency Wraps Wood Fireplace Insert (I2400M) — Regency fi replace products are designed diagram (page 20)
Fig. 21 · Regency fi replace products are designed
Regency Wraps Wood Fireplace Insert (I2400M) — Regency fi replace products are designed diagram (page 20)
Fig. 22 · Regency fi replace products are designed

ance Team carefully inspects each

unit thoroughly before it leaves our

door.

Fireplace Products Interna- tional Ltd. is pleased to extend this Limited Lifetime Warranty to the origi- nal purchaser of a Regency Product.

See the inside back cover for details.

Register your Regency online at

http://www.regency-fi re.com

Installer: Please complete the following information

Dealer Name & Address: ______________________________________________

___________________________________________________________________

Installer: ___________________________________________________________

Phone #: ___________________________________________________________

Date Installed: ______________________________________________________

Serial No.: __________________________________________________________

Regency and Classic are trademarks of FPI Fireplace Products International Ltd.

Printed in Canada

© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.

Printed in Canada

Ask about the Regency Wraps Wood Fireplace Insert (I2400M)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Regency Wraps Wood Fireplace Insert (I2400M)

Be the first to ask — other owners or our team will answer.

Original document

Regency Wraps Wood Fireplace Insert (I2400M) manual PDF

20 pages·850 KB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…