Instruction/ maintenance manual of the product Proflame GTM 9.957.03605 Regency
Go to page of 12
9.957.036 05 PROFLAME GTM SYSTEM USE AND INST ALLA TION INSTRUCTIONS Read the instructions before use. This control must be installed in accordance with the rules in force.
English - 12 2 2 ENGLISH The Proflame GTM is a modular remote control system that directs the functions of a hearth appliance. The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the hearth appliance.
3 Remote Control Supply voltage 4.5 V (three 1.5 V AAA batteries) Ambient temperature ratings 0 - 50 °C (32 - 122 °F) Radio frequency 315 MHz Receiver Supply voltage 6.
4 ENGLISH The Proflame Remote Control System consists of two elements: 1. Proflame Transmitter. 2. Proflame Receiver and a wiring harness to connect the Receiver to the gas valve and stepper motor. The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD display (Fig.
5 ENGLISH The Proflame Receiver (Fig. 3) connects directly to the gas valve and stepper motor with a wiring harness. The Receiver is powered by 4 AA type batteries. The Receiver accepts commands via radio frequency from the Transmitter to operate the appliance in accordance with with the particular Proflame system configuration.
6 ENGLISH REMOTE REMOTE TP TH TPTH Green Whi te Red Black (+) (-) Fig. 5: Wiring diagram. Initializing the System for the first time Install the 4 AA batteries into the receiver battery bay. Note the polarity of battery and insert into the battery bay as indicated on the Battery cover (+/-).
7 ENGLISH Fig. 7: Remote Control display. Temperature indication Display With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display.
8 ENGLISH Remote Flame Control The Proflame GTM has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off.
9 ENGLISH Smart Thermostat (Transmitter Operation) The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures. As the room temperature gets closer to the set point the Smart Function will modulate the flame down.
10 ENGLISH Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the appliance, the number of changes to the room thermostat set point, etc. When the Transmitter batteries are low, a Battery Icon will appear on the LCD display of the Transmitter (Fig.
11 ENGLISH CAUTION Property Damage Hazard. Excessive heat can cause property damage. The appliance can stay lit for many hours. T urn off the appliance if it is not going to be attended for any lenght of time. Always place the T ransmitter where childr en can not reach it.
PROFLAME T ransmitter PROFLAME Receiver Hearth mounted Wa ll mounted 140 37 71 DIMENSIONAL DRA WINGS Dimensions are in millimeters PRG 102 42 REMOTE PRG 115 70 REMOTE.
An important point after buying a device Regency Proflame GTM 9.957.03605 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Regency Proflame GTM 9.957.03605 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Regency Proflame GTM 9.957.03605 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Regency Proflame GTM 9.957.03605 you will learn all the available features of the product, as well as information on its operation. The information that you get Regency Proflame GTM 9.957.03605 will certainly help you make a decision on the purchase.
If you already are a holder of Regency Proflame GTM 9.957.03605, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Regency Proflame GTM 9.957.03605.
However, one of the most important roles played by the user manual is to help in solving problems with Regency Proflame GTM 9.957.03605. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Regency Proflame GTM 9.957.03605 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center