Owners & Installation Manual
P40 Gas Fireplace

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-566b
07/05/06

Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The P40 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P40 has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.
This Regency® product has been tested and listed by Warnock Hersey as a Vented Gas Fireplace Heater to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2005/CSA 2.33-2005 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA 2.17-M91.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used. (Kit# 502-969)
Ensure that structural members are not cut or weakened during installation.




This is a copy of the label that accompanies each P40-NG and P40-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
Copy of Safety Label
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.



YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
The P40 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
Gas fi replace" section) b) Clearances to Combustibles (Refer to
"Clearances" section) c) Mantle Clearances (Refer to "Mantel
Clearances" section) d) Framing & Finishing Requirements
(Refer to "Framing & Finishing" section) e) Venting Requirements (Refer to
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
Convert to propane if desired (Refer to "Conversion from NG to LP" section).
"Venting" section)

a) Brick Panels b) Log Set c) Standard Flush Door d) Flush Louvers e) Finishing trim f) Remote Control
The Heat Release Kit expels warm air from the fi replace to the outside of the building, allowing the fi replace to be operated with less heat entering the room. The kit may be used on either the left or right side.
See Heat Release installation manual for complete details and clearances from side only.
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.
A) Flat on Wall B) Flat on Wall Corner C) Recessed into Wall/Alcove D) Corner
This includes:
A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth is required, unless the unit is raised 4" (102mm). 4) This appliance is Listed for bedroom installations when used with the FireWizard (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.
MOBILE HOME
ADDITIONAL REQUIREMENTS
Vent Termination Locations" section.
DUCT KIT
The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.
GAS FIREPLACE
Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.
See HeatWave installation manual for complete details and clearances from side only.
The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.
Diagram 1

The clearances listed below are minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
* Note: A hearth is required, unless the unit is raised 4" (102mm), see "Hearth Requirements" section for details.
Minimum Clearance from Top of Louver Opening: Mantel Height min. 12" (305mm) (at 1" mantel depth) Ceiling 39" (990mm)

Horizontal Vent Clearances to Combustibles: Top 2-1/2" (64mm) Side 1-1/2" (38mm) Bottom 1-1/2" (38mm)
fi replace and vent system be installed only in
accordance with these instructions.

Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of louver opening are shown in the diagram below.
board.

This drawing is to scale at 1:6 (one inch = 6 inches)
Mantel can be installed anywhere in shaded area using the above scale.
on the mantel and the facing is "heat resistant" or the paint may discolour.
Combustible mantel leg clearances as per diagram:



the hearth height and material. Height = 42-1/2" plus height of hearth.

is access to install the gas lines when the unit is installed. See diagram 3 for details.
The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details. Diagram 2
Diagram 1 · Diagram 3

Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.
The top standoffs are shipped in a fl at position and must be folded into shape and attached.
To set the Vent restriction as indicated in the diagrams in the "Venting Arrangements" section, refer to the instructions below;


Determine the total thickness of facing material to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.
The Top Facing Support & Side Nailing Strips can be mounted in 3 different positions depending on the thickness of the facing material.
The P40 uses the "balanced fl ue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
* For "C" screw position the top facing support is reversed.
connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance.
Vent Restrictor setting at Set 2

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally
K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to
M= Clearance above paved sidewalk or a paved driveway located on public property
- Excluding direct vent or non-condensing appliances, a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family

*(min. 84"/2.1m) N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)
J= Clearance to service regulator vent outlet *(min. 36"/90cm)
L= Clearance to a mechanical air supply inlet *(6'/1.83m)
#3' (91cm) above if within 10' (3m) horizontally.
any other appliance *(12"/30cm) #(9"/23cm)
from the centerline of the regulator.
* (Canada) As specifi ed in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances. # (US) In accordance with the current ANSI Z223.1/NFPA 54, Natioinal Fuel Gas Code.
- Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.
D= Vertical clearance to ventilated soffi t located above the terminal within a horizontal
distance of (24"/60cm) from the centerline of the terminal (min. 23") check with local
A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)
B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)
- If the vent termination is accessible, a certifi ed guard shall be installed.
C= Clearance to permanently closed window *#(min. 12"/30cm)
E= Clearance to unventilated soffi t (min. 15"/38cm)
dwellings and serves both dwellings.
code.

Regency ® Direct Vent System
These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Requirements" section.
Regency® Direct Vent (Flex) System Termination Kit (Part# 946-615) includes all the parts needed to install the P40 with a maximum run of 4 feet.

If longer runs are needed, the Regency® Direct Vent system (Flex) Part# 946-616 includes all the parts needed to install the P40 with a maximum 10' run.

Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized fi nish.
The minimum components required for a basic horizontal termination are:

1 Horizontal Termination Cap 1 90o Elbow 1 Rigid Pipe Adaptor 1 Wall Thimble (Canada only) 1 Length of pipe to suit wall thickness
The minimum components required for a basic vertical termination are:
1 Vertical Termination Cap 1 Rigid Pipe Adaptor 1 Lengths of pipe to adequately penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.
When using Rigid Vent other than Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Do not combine venting components from different venting systems.
Use of the the AstroCap XLTM and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS and Selkirk Direct- Temp systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.
The FPI AstroCap XLTM is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent GS and Selkirk Direct-Temp. AstroCap XLTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
Flashing · Ceiling Firestop

Simpson Dura-Vent components are available directly from FPI.
Description Simpson Dura-Vent Selkirk Direct VentGS® Direct-TempTM
6" Pipe Length, Galvanized 1208 5DT-6 9" Pipe Length, Galvanized 1207 5DT-9 12" Pipe Length, Galvanized 1206 5DT-12 18" Pipe Length, Galvanized N/A 5DT-18 24" Pipe Length, Galvanized 1204 5DT-24 36" Pipe Length, Galvanized 1203 12DT-36 48" Pipe Length, Galvanized 1202 5DT-48
Adjustable Length, 11"-14", Galv. 1211 5DT-AJ
45O Elbow, Galvinized 1245 5DT-EL45 90O Elbow, Galvinized 1290 5DT-EL90S
Ceiling Support 1240 5DT-CS Cathedral Support Box 1241 5DT-CSS Wall Support/Band 1288 5DT-WS/B Offset Support 1289 5DT-OS Wall Thimble 1247 5DT-WT Firestop Spacer 1263 5DT-FS Trim Plate, Black N/A 5DT-TP
High Wind Vertical Cap 1291 5DT-VC High Wind Horizontal Cap 1285 5DT-HC Storm Collar 1253 5DT-SC
Adjustable Flashing, 0/12-6/12 1243 5DT-AF6 Adjustable Flashing, 6/12-12/12 1243S 5DT-AF12
Vinyl Siding Standoff 1250 5DT-VS Snorkel Termination 14" 1282 5DT-ST14 Snorkel Termination 36" 1281 5DT-ST36
FPI 946-604/P Vent Guard (Optional) 770-994 Rigid Pipe Adaptor (Must use with all Rigid Piping)
946-623/P AstroCap XL Horizontal Cap

The diagram shows all allowable combinations of vertical runs with horizontal terminations, one 90o elbow (two 45o elbows equal one 90o elbow).
45-3/8” (1143mm) Minimum Height Requirement
Refer to "Vent Restrictor Position" section for details on how to change the vent restrictor to Set 1 or Set 2 if required. A vent guard maybe required as per local codes, refer to "Exterior Vent Termination Requirements" section for details.


One 90o elbow = Two 45o elbows.
Option V H + H1 A) 2' Min. 2' Max. B) 3' Min. 5' Max. C) 4' Min. 6' Max. D) 5' Min. 7' Max. E) 6' Min. 8' Max.
With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.
VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 2x the vent restrictor setting is set to 1.
Please note minimum 1 foot between 90o elbows is required.
One 90o elbow = Two 45o elbows.

Option V H V + V1 H + H1 A) 0' Min. 1' Max. 1' Min. 1' Max. B) 1' Min. 2' Max. 3' Min. 3' Max. C) 2' Min. 2' Max. 5' Min. 4' Max. D) 3' Min. 2' Max. 7' Min. 5' Max. E) 4' Min. 3 Max. 9' Min. 6' Max. F) 5' Min. 4' Max. 10' Min. 7' Max. G) 6' Min. 5' Max. 11' Min. 8' Max. H) 7' Min. 6' Max. 12' Min. 9' Max.
With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.
VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.

One 90o elbow = Two 45o elbows.
Option V H V + V1 A) 0' Min. 2' Max. 1' Min. B) 1' Min. 4' Max. 2' Min. C) 2' Min. 5' Max. 3' Min. D) 3' Min. 6' Max. 4' Min. E) 4' Min. 7' Max. 5' Min. F) 5' Min. 8' Max. 6' Min.
With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 8 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 2x the vent restrictor setting is set to 1.
For additional vertical venting with 2 x 90o elbows, refer to next page.
One 90o elbow = Two 45o elbows.
Option V H + H1 V + V1 A) 0' Min. 2' Max. 3' Min. B) 1' Min. 2' Max. 3' Min. C) 2' Min. 3' Max. 4' Min. D) 3' Min. 4' Max. 6' Min. E) 4' Min. 5' Max. 7' Min. F) 5' Min. 6' Max. 8' Min. G) 6' Min. 7' Max. 9' Min. H) 7' Min. 8' Max. 10' Min.
With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed.
4 10 12 12 14
Vent Restrictor on Set 2
Vent Restrictor on Set 1
Minimum 8’9” (2.6m)
Rigid Pipe (Part # 770-994).
Max. 10’ (3m)(centerline to centerline) Minimum 12” (305mm)
Vertical Height (Feet) · Vent Restrictor · Factory Set


TERMINATION (Rigid Vent Systems)
Install the vent system according to the manufacturer's instructions included with the components.
If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable.

The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
9) Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap suffi cient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe section. See Diagram 6.
or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fi re. The arrow on the vent cap should be pointing up.

b) The location of the horizontal vent
and high temp silicone sealant to outer pipe on every twist-lock joint.
termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations"
siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.
Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.


TERMINATION (Rigid Vent Systems)

2) Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance fl ue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at his point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may wish to relocate the appliance or to offset, as shown in Diagram 2 to avoid cutting load bearing members.
A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.

the vent passes through must be enclosed.

to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (Diagram 2). Galvanized pipe is desirable above the roofl ine due to its higher corrosion resistance. Continue to add pipe sections through the fl ashing until the height of the vent cap meets the minimum height requirements specifi ed in Diagram 5 or local codes. Note that for steep roof pitches, the vertical height must be increased. Diagram 3

Diagram 2

WITH FLEX VENT SYSTEM

and side & bottom clearance of 1-1/2"(38mm) must be maintained except that only a 1" (25mm) clearance is needed at the termination end. We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.

covered wall, a vinyl siding standoff or vinyl furring strips must be used to ensure that the termination is not recessed into the siding.


PILOT ADJUSTMENT
For 0 to 4500 feet altitude Front Burner Orifi ce: #44 Back Burner Orifi ce: #35 Max. Input Rating 45,000 Btu/h Min. Input Rating 13,000 Btu/h
The gas line can be brought through the bottom right of the appliance. The gas valve is situated on the bottom of the unit.
The gas line connection may be made of rigid pipe, copper pipe or an approved fl ex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.
Supply Pressure min.5.0" w.c. Manifold Pressure (High) 3.5"+/- 0.3"w.c.
Periodically check the pilot fl ames. Correct fl ame pattern has three strong blue fl ames: 1 fl owing around the thermopile, 1 around the thermocouple and 1 fl owing across the burner (it does not have to be touching the burner).
Log Set: Ceramic fi bre, 8 per set + ember bed. Vent System: Simpson Dura-Vent Direct Vent System, Regency® Flex Kit, Selkirk Direct-Temp
For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.
When using copper or fl ex connectors use only approved fi ttings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and fl ex connectors are usually considered to meet this requirement.
contact your Regency® dealer for further instructions.
Incorrect fl ame pattern will have small, probably yellow fl ames, not coming into proper contact with the rear burner or thermopile or thermocouple.
For 0 to 4500 feet altitude Front Burner Orifi ce: #55 Back Burner Orifi ce: #53 Max. Input Rating 43,000 Btu/h Min. Input Rating 12,000 Btu/h
Supply Pressure min.12.0" w.c.
Manifold Pressure (High) 10"+/- 0.5" w.c.
Log Set: Ceramic fi bre, 8 per set + ember bed. Vent System: Simpson Dura-Vent Direct Vent System, Regency® Flex Kit, Selkirk Direct-Temp
This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M91).
Conversion Kit# 502-969

BACK-UP BATTERY
TESTING
INSTALLATION (within Power Module)
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.
The 9V battery operates the rear burner and the AA battery operates the DC Sparker for lighting the pilot under power outage conditions.
The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

inlet and manifold pressures should be checked using the valve pressure ports on the valve.




Power Module

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
LP Conversion Kit Contains:
Qty. Part # Description 1 910-462 LP Conversion Coil 1 910-037 LP Pilot Orifi ce 1 904-345 Orifi ce #53 1 904-575 Orifi ce #55 1 904-529 Allen Key 1 918-590 LP Conversion Decal 1 908-528 Red Propane Label 1 918-587 Instruction Sheet









WARNING! This conversion kit should be installed by a qualifi ed service agency in ac- cordance with the authority having jurisdiction. If the information in these instructions are not followed exactly, a fi re, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualifi ed service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the con- verted appliance is checked as speci- fi ed in the manufacturer's instructions supplied with the kit.


with the appliance.

Control Module · J9 Jumper · Modulating Coil

Must install 1 set of brick panels with the P40.


Left Side Small Back Brick Panel
Right Side Small Back Brick Panel


Brick Panels Completely Installed



Read the instructions below carefully and refer to the pictures. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

Log kit (Part # 502-930) contains the following pieces:
a) 03-32 Back Log b) 03-40 Ember Bed c) 03-34 Front Left Log d) 03-33 Middle Back Log e) 03-35 Middle Left Cross Log f) 03-36 Middle Right Cross Log g) 03-37 Front Right Log h) 03-38 Right Side Ember Bed i) 03-38 Left Side Ember Bed j) 902-154 Embers Lava k) 902-179 Vermiculite




Ember Bed Burner Tube











Ember Bed 03-38 Right

Ember Bed 03-38 Left

Ember Bed 03-38 Left 03-38 Right

STANDARD FLUSH DOOR
FLUSH LOUVERS
Aeration Adjustment should only be per- formed by an authorized Regency® Installer at the time of installation or service.

The rear burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.
The rear burner air shutter can be adjusted by moving the air shutter wire. Open (pull) the air shutter wire for a blue fl ame or close (push) for a more yellow fl ame.

* The front burner aeration is factory set, do not adjust this setting.
Minimum Air Shutter Opening:
NG Front Burner* 1/8" Rear Burner 1/4"
LP Front Burner* 3/8" Rear Burner 5/16"
resulting from improperly setting the aeration controls is NOT covered under warranty.
a) Ensure that the bottom louver is open.

b) Pull out the Manual Control Box from the
right side under the bottom of the fi rebox.
c) Using the 2 screws on the louver, secure
the control box onto the right side of the louver.

Rear Burner Adjustment Wire
Adjustment Wire - Pull to open or
push to close aeration cap.
be OVER not under the gas line.


A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully. The front and rear burners will operate on low, when the unit is running on battery back-up.
(Do not cut the ground terminal off under any circumstances.)


OPERATING INSTRUCTIONS
DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.
The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on.
4) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 1) to 4). If knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.
When fi rst operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.
"HIGH" and resume it's last setting after 20 seconds of operation.
is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.
SHUTDOWN PROCEDURE
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!
During the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Only when the pilot holds, without pressure being applied to the control knob, reapply the tension springs to the door. The unit must not be operated with the tension springs unattached.
you must fi rst release the tension springs below the door.
Ensure that the 3 way switch on the manual control panel is in the "Remote" position.

Manual Control Panel · 3-way Switch

OPERATION DURING
When in "Manual" position; In the event of a power failure, if the 3-way switch is in the "Manual" position the front buner will remain on at the lowest setting and will remain on when power resumes. If the rear burner is not in use, to operate see "Rear Burner Opera- tion" above.

Both burners when on will operate at the lowest fl ame setting. The BTU's for NG will be 13,000 and 12,000 for LP.
When power resumes the unit will remain on at the lowest setting until reset using the remote control.
3-way switch on the Manual Control Panel to the "Remote" position to be able to use the FireWizardTM Remote Control.
SUMMARY OF
CONTROL FUNCTIONS The FireWizardTM Remote Control was de- veloped to provide a user-friendly system to operate your appliance. The operating range is approximately 10 metres (32 feet) from the fi replace.
For the Manual Control Box, located on
right hand side of the bottom louver.
When in "Remote" position; In the event of a power failure, if the 3-way switch is in the "Remote" position, the unit cannot be operated with the Remote Control until after power is restored.
See FireWizard Remote Control Manual for complete details on operation functions and instructions.
On/Off Button If the unit is off, pressing and releasing this button once will switch the unit on. The unit will be on high for 20 seconds and then resume to its last settings.
To operate unit during a power failure;

If the unit is on, pressing and releasing this button once will switch the unit off.
lowest fl ame setting. The BTU's for NG will be 13,000 and 12,000 for LP.
Flame: There are seven fl ame settings that can be adjusted by pressing and releasing the plus (+) and minus (-) FLAME button.
Front Burner Operation: 1) Open the bottom louver to gain access to the Manual Control Panel. 2) To turn on the front burner, change the 3-way switch to "Manual" position.
Increase: If the unit is on, pressing and releasing the fl ame plus (+) button once will increase the fl ame height to the next available high setting.
Rear Burner Operation: 1) Open the bottom louver to gain access to the Manual Control Panel. 2) To turn on the rear burner, change the Rear Burner Switch to the "On" position. Changing the switch to the "Off" postion will turn the rear burner off.
Decrease: If the unit is on, pressing and releasing the fl ame minus (-) button once will decrease the fl ame height to the next available low setting.
Fan: There are three fan speeds that can be adjusted by pressing and releasing the plus (+) and minus (-) FAN button.
Pressing and releasing the plus (+) FAN button will change the fan speed as follows:
OFF -> LOW -> MEDIUM -> HIGH -> OFF
Pressing and releasing the minus (-) FAN button will be the reverse of the above.

COPY OF LIGHTING PLATE INSTRUCTIONS NORMAL OPERATING
SOUNDS OF GAS APPLIANCES
It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes,
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.
Blower: Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.
A) This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these
instructions exactly.
B) BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the fl oor
because some gas is heavier than air and will settle on the fl oor.
- Do not try to light any appliance. - Do not touch any electric switch, do not use any phone in your building. - Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s
instructions. - If you cannot reach your gas supplier, call the fi re department.
Burner Tray: The burner tray is positioned directly under the burner tube and logs and is made of a different gauge material from the rest of the fi rebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.
C) Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it, call a qualifi ed service technician. Forced or attempted repair may result in a fi re or explosion.
D) Do not use this appliance if any part has been under water. Immediately call a qualifi ed service
technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
E) This appliance needs fresh air for safe operation and must be installed so there are provisions for
adequate combustion and ventilation air.
Pilot Flame: While the pilot fl ame is on it can make a very slight "whisper" sound.
STOP! Read the safety information above on this label.
Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.
VEILLEUSE OFF
Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.
ELEMENT THERMOELECTRIQUE
4) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 1) to 4). If knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 5) Turn gas control knob counterclock-wise to “ON”.
918-583

MAINTENANCE INSTRUCTIONS
GENERAL VENT
THERMOPILE / THERMOCOUPLE
MAINTENANCE
Conduct an inspection of the venting system semiannually. Recommended areas to inspect as follows:
GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-155).
The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.
the glass properly secured in place.
The finish on the louvers require little maintenance, and need only be cleaned with a damp cloth.
DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.
create carbon build-up and will severely alter the unit's performance which is not covered under warranty.
Clean any fi ngerprints off before turning the unit on.

FAN REPLACEMENT
DOOR GLASS
Your Regency® fi replace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials.


* Do not clean when the glass is hot. * The use of substitute glass will void all product warranties. * Care must be taken to avoid breakage of the glass. * Do not strike or abuse the glass. * Do not operate this fi replace without the glass front or with a cracked or broken glass front. * Wear gloves when removing damaged or broken glass. * Replacement of the glass panel(s) should be done by a licensed or qualifi ed service per son.


In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only.
Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Door Installation in "Standard Flush Door" section.



Power Module · Control Module

VALVE REPLACEMENT










Wa & Wb Wires Vu Wires





fi t behind the metal posts when re- installing.

6) Replace the Control Module and reverse steps to re-install. POWER MODULE
CONTROL MODULE
REPLACEMENT
REPLACEMENT
BACKUP BATTERY
burner and the AA battery operates the DC Sparker for lighting the pilot under power outage conditions.



J2
J1


MAIN ASSEMBLY
Part # Description 10) 502-528 Brick Panel Base (Set of 3)
Part # Description 910-930 FireWizardTM Remote Control 918-582 Manual FireWizardTM
502-901 Brick Panel Set Standard Brown 502-902 Brick Panel Set Standard Red 11) 502-040 Cast Iron Fender 502-075 Front Ember Tray
910-215/P Fan 115 Volt / 110 Cfm (dual blower) 910-073 Spark Generator Battery Holder 910-074 Spark Generator Swtch C/W Wire
910-813 Power Cord 120Vlt Plug in Fan
910-927 Wire Harness Twin Fan 910-928 Wire Harness Solenoid Switch 910-939 Wire Sparker - Combo Drive
502-930 Log Set - (Oak)
910-935 Switch Manual Control 910-528 Wire - 54 in.

918-566 Manual

VALVE TRAY ASSEMBLY
502-574/P Valve Assembly - NG 502-576/P Valve Assembly - LP 502-969 Conversion - LP
Part # Description

FLUSH DOOR & LOUVERS
Part # Description 502-910 Flush Louvers (Set) - Black 133) * Flush Louver - Top 134) * Flush Louver - Bottom
502-924 Finishing Trim - Black 141) * Trim Side Left 142) * Trim Side Right 143) * Trim Top
*Not available as a replacement part.

___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________

___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________

Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product. This warranty is not transferable.
The Warranty: Limited Lifetime The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for fi ve (5) years for parts and subsidized labour* and parts only thereafter.
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for fi ve (5) years and parts only thereafter from date of purchase.
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.
Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, ie. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly components, and gas valves are covered for one year parts and subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.
FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.
Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of installation. Reported damage after this time will be subject to rejection.
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect.
The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency® product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.
FPI will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryer, etc.
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty on this product.
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.
* Subsidy according to job scale as predetermined by FPI.


FPI fi replaces are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door.
FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product.
See the inside back cover for details.
http://www.regency-fi re.com
Dealer Name & Address: ______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: __________________________________________________________
Printed in Canada Regency® is a trademark of FPI Fireplace Products International Ltd.
© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.