Regency P40

48 pages·3.1 MB·Indoor Fireplace·PDF·ENDEFRITNLJA
Regency P40
Table of Contents 80 sections www.regency-fi re.com · Owners & Installation Manual · P40 Gas Fireplace · MODELS: P40-NG Natural Gas P40-LP Propane · … ShowHide
www.regency-fi re.comp.1Owners & Installation Manualp.1P40 Gas Fireplacep.1MODELS: P40-NG Natural Gas P40-LP Propanep.1To the New Owner:p.2SAFETY LABELp.4REQUIREMENTSp.5MA Code - CO Detector (for the State of Massachusetts only)p.5UNIT DIMENSIONSp.6Dimensionsp.6IMPORTANT MESSAGEp.7SAVE THESE INSTRUCTIONSp.7GENERAL SAFETYp.7INFORMATIONp.7BEFORE YOU STARTp.7CHECKLISTp.7HEAT RELEASE KITp.8HEARTH REQUIREMENTSp.8Floor Mounted Fireplacep.8MANUFACTUREDp.8MOBILE HOMEp.8ADDITIONAL REQUIREMENTSp.8HEATWAVEp.8Raised Fireplacep.8DUCT KITp.8LOCATING YOURp.8GAS FIREPLACEp.8CLEARANCESp.9MANTEL CLEARANCESp.10MANTEL LEG CLEARANCESp.10FRAMING & FINISHINGp.11PRIOR TO INSTALLATIONp.12VENT RESTRICTORp.12POSITIONp.12TOP STANDOFF ASSEMBLYp.12TOP FACING SUPPORT ANDp.12SIDE NAILING STRIPSp.12VENTING INTRODUCTIONp.12EXTERIOR VENT TERMINATION REQUIREMENTSp.13VENTING ARRANGEMENTSp.14HORIZONTAL TERMINATION (FLEX)p.14Regency ® Direct Vent Systemp.14RIGID PIPE VENTING SYSTEMSp.15BASIC HORIZONTAL & VERTICAL TERMINATIONSp.15RIGID PIPE VENTING COMPONENTS LISTp.16ALLOWABLE HORIZONTAL TERMINATIONSp.17Horizontal Venting with Three (3) 90 o Elbowsp.18Vertical Venting with Two (2) 90 o Elbowsp.19V Hp.19Vertical Venting with Three (3) 90 o Elbowsp.19V H1 Hp.19ALLOWABLE VERTICAL TERMINATIONSp.20UNIT INSTALLATIONp.21WITH HORIZONTALp.21TERMINATION (Rigid Vent Systems)p.21WITH VERTICALp.22Offset Chartp.22HORIZONTAL TERMINATIONp.23WITH FLEX VENT SYSTEMp.23GAS LINE INSTALLATIONp.24PILOT ADJUSTMENTp.24P40-NG SYSTEM DATAp.24P40-LP SYSTEM DATAp.24HIGH ELEVATIONp.24GAS PIPE PRESSUREp.25SIT VALVE DESCRIPTIONp.25BACK-UP BATTERYp.25TESTINGp.25INSTALLATION (within Power Module)p.25CONVERSION KIT #502-969 FROM NG TO LPp.26Installer Notice: These instructions must be leftp.27BRICK PANEL INSTALLATIONp.28LOG SET INSTALLATIONp.29Completed Log Set Installationp.31AERATION ADJUSTMENTp.32STANDARD FLUSH DOORp.32FLUSH LOUVERSp.32WIRING DIAGRAMp.33OPERATING INSTRUCTIONSp.34FIRST FIREp.34
Page 1 of the Regency P40 user manual — MODELS: P40-NG Natural Gas P40-LP Propane
Page 1 · click to enlarge
Page 1

www.regency-fi re.com

Owners & Installation Manual

P40 Gas Fireplace

Regency P40 — www.regency-fi re.com diagram (page 1)
Fig. 1 · www.regency-fi re.com

MODELS: P40-NG Natural Gas P40-LP Propane

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fi re department. Tested by:Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-566b

07/05/06

Page 2 of the Regency P40 user manual — MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
Page 2 · click to enlarge
Page 2

To the New Owner:

Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The P40 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P40 has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.

MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE

This Regency® product has been tested and listed by Warnock Hersey as a Vented Gas Fireplace Heater to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2005/CSA 2.33-2005 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA 2.17-M91.

This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.

This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used. (Kit# 502-969)

Ensure that structural members are not cut or weakened during installation.

Regency P40 — MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE diagram (page 2)
Fig. 2
Page 3 of the Regency P40 user manual — To the New Owner:
Page 3 · click to enlarge
Page 3
Page 3 of the Regency P40 user manual — To the New Owner:
Page 4 of the Regency P40 user manual — SAFETY LABEL
Page 4 · click to enlarge
Page 4

SAFETY LABEL

This is a copy of the label that accompanies each P40-NG and P40-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.

Copy of Safety Label

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

Page 5 of the Regency P40 user manual — MA Code - CO Detector (for the State of Massachusetts only)
Page 5 · click to enlarge
Page 5

REQUIREMENTS

MA Code - CO Detector (for the State of Massachusetts only)

5.08Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements:

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) EXEMPTIONSThe following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

Page 6 of the Regency P40 user manual — Dimensions
Page 6 · click to enlarge
Page 6

UNIT DIMENSIONS

Dimensions

Regency P40 — Dimensions diagram (page 6)
Fig. 3 · Dimensions
Page 7 of the Regency P40 user manual — CHECKLIST
Page 7 · click to enlarge
Page 7

IMPORTANT MESSAGE

12. Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

SAVE THESE INSTRUCTIONS

The P40 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.

CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

13. Do not slam shut or strike the glass door.
14. Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

GENERAL SAFETY

15. The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

INFORMATION

1. The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

BEFORE YOU START

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

2. The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

CHECKLIST

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

1. Locate appliance a) Room location (Refer to "Locating Your
3. See general construction and assembly instructions. The appliance and vent should be enclosed.

Gas fi replace" section) b) Clearances to Combustibles (Refer to

"Clearances" section) c) Mantle Clearances (Refer to "Mantel

4. This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.

Clearances" section) d) Framing & Finishing Requirements

(Refer to "Framing & Finishing" section) e) Venting Requirements (Refer to

5. Inspect the venting system annually for blockage and any signs of deterioration.
2. Assemble Top Standoffs and Top Facing Support and Side Nailing Strips (Refer to "Unit Assembly Prior to Installation). NOTE: Must be done before installing unit into place.
6. Venting terminals shall not be recessed into a wall or siding.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

7. Any safety glass removed for servicing must be replaced prior to operating the appliance.
3. Install vent (Refer to "Venting Arrangement" sections).
8. To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.
4. Back-up battery installation. Refer to "Backup Battery Installation" section.
9. Wear gloves and safety glasses for protection while doing required maintenance.
5. Make gas and electrical connections. Test the pilot. Must be as per diagram (Refer to "Pilot Adjustment " section).

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE- CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

10. Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

Convert to propane if desired (Refer to "Conversion from NG to LP" section).

11. Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.
6. Test Gas Pressure. (Refer to "Gas Pipe Pressure Testing" section).

"Venting" section)

Page 8 of the Regency P40 user manual — LOCATING YOUR
Page 8 · click to enlarge
Page 8
7. Install standard and optional features. Refer to the following sections:

HEAT RELEASE KIT

a) Brick Panels b) Log Set c) Standard Flush Door d) Flush Louvers e) Finishing trim f) Remote Control

The Heat Release Kit expels warm air from the fi replace to the outside of the building, allowing the fi replace to be operated with less heat entering the room. The kit may be used on either the left or right side.

See Heat Release installation manual for complete details and clearances from side only.

8. Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.

HEARTH REQUIREMENTS

A) Flat on Wall B) Flat on Wall Corner C) Recessed into Wall/Alcove D) Corner

This includes:

1. Clocking the appliance to ensure the correct fi ring rate (rate noted on label 45,000 (NG) Btu/h, 43,000 (LP) Btu/h) after burning appliance for 15 minutes.

A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth is required, unless the unit is raised 4" (102mm). 4) This appliance is Listed for bedroom installations when used with the FireWizard (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

2. If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

Floor Mounted Fireplace

5. The P40 Direct Vent Gas Fireplace is approved for alcove installations, see "Clearances" section for details.
6. We recommend that you plan your installation on paper using exact measurements for clearances and fl oor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

MANUFACTURED

MOBILE HOME

ADDITIONAL REQUIREMENTS

Vent Termination Locations" section.

1. Ensure that structural members are not cut or weakened during installation.

HEATWAVE

2. Ensure proper grounding using the #8 ground lug provided. See "Wiring Diagram" section.

Raised Fireplace

DUCT KIT

The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.

LOCATING YOUR

GAS FIREPLACE

Up to two kits may be installed on the fi replace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.

1. When selecting a location for your fi replace, ensure that the clearances are met.
2. The appliance must be installed on a fl at, solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or raised up on a platform to enhance its visual impact. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

See HeatWave installation manual for complete details and clearances from side only.

3. The P40 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

Diagram 1

Page 9 of the Regency P40 user manual — CLEARANCES
Page 9 · click to enlarge
Page 9

CLEARANCES

The clearances listed below are minimum distances unless otherwise stated:

A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.

standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

Clearance to Combustibles fromBack 0" (0mm) Side 0" (0mm) Floor 0"* (0mm)

* Note: A hearth is required, unless the unit is raised 4" (102mm), see "Hearth Requirements" section for details.

Minimum Clearance from Top of Louver Opening: Mantel Height min. 12" (305mm) (at 1" mantel depth) Ceiling 39" (990mm)

Side Wall to Unit8" (203mm)
Regency P40 — CLEARANCES diagram (page 9)
Fig. 4

Horizontal Vent Clearances to Combustibles: Top 2-1/2" (64mm) Side 1-1/2" (38mm) Bottom 1-1/2" (38mm)

Vertical Vent Clearances to CombustiblesAll Sides 1-1/4" (32mm)
Alcove ClearancesMax. Depth 36" (914mm) Min. Width 56" (1422mm) Min. Height 72" (1829mm)

fi replace and vent system be installed only in

accordance with these instructions.

Page 10 of the Regency P40 user manual — MANTEL LEG CLEARANCES
Page 10 · click to enlarge
Page 10

MANTEL CLEARANCES

Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of louver opening are shown in the diagram below.

board.

Regency P40 — MANTEL CLEARANCES diagram (page 10)
Fig. 5

This drawing is to scale at 1:6 (one inch = 6 inches)

Mantel can be installed anywhere in shaded area using the above scale.

on the mantel and the facing is "heat resistant" or the paint may discolour.

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram:

Regency P40 — MANTEL LEG CLEARANCES diagram (page 10)
Fig. 6
Page 11 of the Regency P40 user manual — FRAMING & FINISHING
Page 11 · click to enlarge
Page 11

FRAMING & FINISHING

1. Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 42-1/2" high x 40-1/2" wide x 20-1/16" deep (1080mm H x 1029mm W x 508mm D), see Diagram 1. Also see Diagram 2 for corner installations.
Regency P40 — FRAMING & FINISHING diagram (page 11)
Fig. 7

the hearth height and material. Height = 42-1/2" plus height of hearth.

Regency P40 — FRAMING & FINISHING diagram (page 11)
Fig. 8

is access to install the gas lines when the unit is installed. See diagram 3 for details.

2. For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fi replace itself.)
3. The unit does not have to be completely enclosed in a chase. A noncombustible header must be used. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details. Diagram 2

Diagram 1 · Diagram 3

Page 12 of the Regency P40 user manual — VENTING INTRODUCTION
Page 12 · click to enlarge
Page 12

Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

PRIOR TO INSTALLATION

Regency P40 — PRIOR TO INSTALLATION diagram (page 12)
Fig. 9

VENT RESTRICTOR

POSITION

Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.

TOP STANDOFF ASSEMBLY

The top standoffs are shipped in a fl at position and must be folded into shape and attached.

To set the Vent restriction as indicated in the diagrams in the "Venting Arrangements" section, refer to the instructions below;

1. Remove the standoffs from top of the fi replace.
1. Remove the top louver if installed. 2) Loosen the screw on the vent restrictor indicating plate. 3) Rotate the vent restrictor adjustment rod counter clockwise to line up the slot on the indicating plate with the point on the air box to the required setting. 4) Tighten screw to lock position.
2. Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the prepunched screw holes on the fi replace top line up.
3. Attach the standoff securely to the top with 2 screws per standoff (on opposite corners).
Regency P40 — TOP STANDOFF ASSEMBLY diagram (page 12)
Fig. 10
Regency P40 — TOP STANDOFF ASSEMBLY diagram (page 12)
Fig. 11

TOP FACING SUPPORT AND

2. Use the same screw hole position for the Side Nailing Strips as was used for the Top Facing Support. Attach each side nailing strip using 3 screws.

SIDE NAILING STRIPS

Determine the total thickness of facing material to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.

The Top Facing Support & Side Nailing Strips can be mounted in 3 different positions depending on the thickness of the facing material.

VENTING INTRODUCTION

Screw PositioFacing Material Depth n A1/2" / 13mm B7/8" / 22mm C*1-1/4" / 32mm

The P40 uses the "balanced fl ue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

* For "C" screw position the top facing support is reversed.

connected to any other appliance.

1. Mount Top Facing Support using the 3 supplied screws into the three pre-punched screw holes on the top front of the unit. Use hole positions A, B, or C depending on your facing depth.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance.

Vent Restrictor setting at Set 2

Page 13 of the Regency P40 user manual — EXTERIOR VENT TERMINATION REQUIREMENTS
Page 13 · click to enlarge
Page 13

EXTERIOR VENT TERMINATION REQUIREMENTS

H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally

K= Clearance to non-mechanical air supply inlet to building or the combustion air inlet to

M= Clearance above paved sidewalk or a paved driveway located on public property

- Excluding direct vent or non-condensing appliances, a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family

Regency P40 — EXTERIOR VENT TERMINATION REQUIREMENTS diagram (page 13)
Fig. 12

*(min. 84"/2.1m) N= Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)

J= Clearance to service regulator vent outlet *(min. 36"/90cm)

L= Clearance to a mechanical air supply inlet *(6'/1.83m)

#3' (91cm) above if within 10' (3m) horizontally.

any other appliance *(12"/30cm) #(9"/23cm)

from the centerline of the regulator.

* (Canada) As specifi ed in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances. # (US) In accordance with the current ANSI Z223.1/NFPA 54, Natioinal Fuel Gas Code.

- Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.

D= Vertical clearance to ventilated soffi t located above the terminal within a horizontal

distance of (24"/60cm) from the centerline of the terminal (min. 23") check with local

A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)

- If the vent termination is accessible, a certifi ed guard shall be installed.

C= Clearance to permanently closed window *#(min. 12"/30cm)

E= Clearance to unventilated soffi t (min. 15"/38cm)

dwellings and serves both dwellings.

F= Clearance to outside corner13"
G= Clearance to inside corner13"

code.

Page 14 of the Regency P40 user manual — HORIZONTAL TERMINATION (FLEX)
Page 14 · click to enlarge
Page 14

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency ® Direct Vent System

These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Requirements" section.

Regency® Direct Vent (Flex) System Termination Kit (Part# 946-615) includes all the parts needed to install the P40 with a maximum run of 4 feet.

Regency P40 — HORIZONTAL TERMINATION (FLEX) diagram (page 14)
Fig. 13
1. 8" dia. fl exible liner (4 ft. length) 2) 5" dia. fl exible liner (4 ft. length) 3) spring spacers (4) 4) thimble 5) AstroCap XL termination cap (1) 6) screws (12) 7) tube of Mill Pac (1) 8) plated screws (8) 9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4) 10) vinyl siding standoff

If longer runs are needed, the Regency® Direct Vent system (Flex) Part# 946-616 includes all the parts needed to install the P40 with a maximum 10' run.

1. 8" dia. fl exible liner (10 ft. length) 2) 5" dia. fl exible liner (10 ft. length) 3) spring spacers (7) 4) thimble (2) 5) AstroCap XL termination cap (1) 6) screws (12) 7) tube of Mill Pac (1) 8) plated screws (8) 9) screws #8 x 1-1/2" Drill Point, Stainless Steel (4) 10) vinyl siding standoff
1. Liner sections should be continuous without any joints or seams.
2. Only Flex pipe purchased from FPI may be used for Flex installations.
3. Horizontal vent must be supported every 3 feet. (For 10' fl ex kit 946-616 only.)
Page 15 of the Regency P40 user manual — BASIC HORIZONTAL & VERTICAL TERMINATIONS
Page 15 · click to enlarge
Page 15

RIGID PIPE VENTING SYSTEMS

BASIC HORIZONTAL & VERTICAL TERMINATIONS

Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized fi nish.

The minimum components required for a basic horizontal termination are:

Regency P40 — BASIC HORIZONTAL & VERTICAL TERMINATIONS diagram (page 15)
Fig. 14

1 Horizontal Termination Cap 1 90o Elbow 1 Rigid Pipe Adaptor 1 Wall Thimble (Canada only) 1 Length of pipe to suit wall thickness

The minimum components required for a basic vertical termination are:

1 Vertical Termination Cap 1 Rigid Pipe Adaptor 1 Lengths of pipe to adequately penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

When using Rigid Vent other than Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

Do not combine venting components from different venting systems.

Use of the the AstroCap XLTM and FPI Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS and Selkirk Direct- Temp systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

The FPI AstroCap XLTM is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent GS and Selkirk Direct-Temp. AstroCap XLTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Flashing · Ceiling Firestop

Page 16 of the Regency P40 user manual — RIGID PIPE VENTING COMPONENTS LIST
Page 16 · click to enlarge
Page 16

RIGID PIPE VENTING COMPONENTS LIST

Simpson Dura-Vent components are available directly from FPI.

Description Simpson Dura-Vent Selkirk Direct VentGS® Direct-TempTM

6" Pipe Length, Galvanized 1208 5DT-6 9" Pipe Length, Galvanized 1207 5DT-9 12" Pipe Length, Galvanized 1206 5DT-12 18" Pipe Length, Galvanized N/A 5DT-18 24" Pipe Length, Galvanized 1204 5DT-24 36" Pipe Length, Galvanized 1203 12DT-36 48" Pipe Length, Galvanized 1202 5DT-48

Adjustable Length, 11"-14", Galv. 1211 5DT-AJ

45O Elbow, Galvinized 1245 5DT-EL45 90O Elbow, Galvinized 1290 5DT-EL90S

Ceiling Support 1240 5DT-CS Cathedral Support Box 1241 5DT-CSS Wall Support/Band 1288 5DT-WS/B Offset Support 1289 5DT-OS Wall Thimble 1247 5DT-WT Firestop Spacer 1263 5DT-FS Trim Plate, Black N/A 5DT-TP

High Wind Vertical Cap 1291 5DT-VC High Wind Horizontal Cap 1285 5DT-HC Storm Collar 1253 5DT-SC

Adjustable Flashing, 0/12-6/12 1243 5DT-AF6 Adjustable Flashing, 6/12-12/12 1243S 5DT-AF12

Vinyl Siding Standoff 1250 5DT-VS Snorkel Termination 14" 1282 5DT-ST14 Snorkel Termination 36" 1281 5DT-ST36

FPI 946-604/P Vent Guard (Optional) 770-994 Rigid Pipe Adaptor (Must use with all Rigid Piping)

946-623/P AstroCap XL Horizontal Cap

Page 17 of the Regency P40 user manual — ALLOWABLE HORIZONTAL TERMINATIONS
Page 17 · click to enlarge
Page 17

VENTING ARRANGEMENTS

ALLOWABLE HORIZONTAL TERMINATIONS

The diagram shows all allowable combinations of vertical runs with horizontal terminations, one 90o elbow (two 45o elbows equal one 90o elbow).

45-3/8” (1143mm) Minimum Height Requirement

Refer to "Vent Restrictor Position" section for details on how to change the vent restrictor to Set 1 or Set 2 if required. A vent guard maybe required as per local codes, refer to "Exterior Vent Termination Requirements" section for details.

  • Maintain clearances to combustibles as listed in "Clearances" section
  • Horizontal vent must be supported every 3 feet.
  • Firestops are required at each fl oor level and whenever passing through a wall.
  • A wall thimble is required for all horizontal terminations.
Show 8 more labels / short text on this page
Horizontal (Feet) · Vertical Height (Feet) · Vent Restrictor · on Set 2 · Vent Restrictor · Vent Restrictor · on Set 1 · Factory Set
Page 18 of the Regency P40 user manual — Horizontal Venting with Three (3) 90 o Elbows
Page 18 · click to enlarge
Page 18
Regency P40 — Horizontal Venting with Three (3) 90 o Elbows diagram (page 18)
Fig. 15 · Horizontal Venting with Three (3) 90 o Elbows

One 90o elbow = Two 45o elbows.

Option V H + H1 A) 2' Min. 2' Max. B) 3' Min. 5' Max. C) 4' Min. 6' Max. D) 5' Min. 7' Max. E) 6' Min. 8' Max.

With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.

VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 2x the vent restrictor setting is set to 1.

Please note minimum 1 foot between 90o elbows is required.

Horizontal Venting with Three (3) 90 o Elbows

One 90o elbow = Two 45o elbows.

Regency P40 — Horizontal Venting with Three (3) 90 o Elbows diagram (page 18)
Fig. 16 · Horizontal Venting with Three (3) 90 o Elbows

Option V H V + V1 H + H1 A) 0' Min. 1' Max. 1' Min. 1' Max. B) 1' Min. 2' Max. 3' Min. 3' Max. C) 2' Min. 2' Max. 5' Min. 4' Max. D) 3' Min. 2' Max. 7' Min. 5' Max. E) 4' Min. 3 Max. 9' Min. 6' Max. F) 5' Min. 4' Max. 10' Min. 7' Max. G) 6' Min. 5' Max. 11' Min. 8' Max. H) 7' Min. 6' Max. 12' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.

VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.

Page 19 of the Regency P40 user manual — V H1 H
Page 19 · click to enlarge
Page 19

Vertical Venting with Two (2) 90 o Elbows

One 90o elbow = Two 45o elbows.

Option V H V + V1 A) 0' Min. 2' Max. 1' Min. B) 1' Min. 4' Max. 2' Min. C) 2' Min. 5' Max. 3' Min. D) 3' Min. 6' Max. 4' Min. E) 4' Min. 7' Max. 5' Min. F) 5' Min. 8' Max. 6' Min.

With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 8 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

V H

VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 2x the vent restrictor setting is set to 1.

For additional vertical venting with 2 x 90o elbows, refer to next page.

Vertical Venting with Three (3) 90 o Elbows

One 90o elbow = Two 45o elbows.

Option V H + H1 V + V1 A) 0' Min. 2' Max. 3' Min. B) 1' Min. 2' Max. 3' Min. C) 2' Min. 3' Max. 4' Min. D) 3' Min. 4' Max. 6' Min. E) 4' Min. 5' Max. 7' Min. F) 5' Min. 6' Max. 8' Min. G) 6' Min. 7' Max. 9' Min. H) 7' Min. 8' Max. 10' Min.

With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

V H1 H

VENT RESTRICTOR SETTING: When total vertical exceeds total horizontal by 3x the vent restrictor setting is set to 1.

Page 20 of the Regency P40 user manual — ALLOWABLE VERTICAL TERMINATIONS
Page 20 · click to enlarge
Page 20

VENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed.

4 10 12 12 14

Maximum40 ft. (12.2m)

Vent Restrictor on Set 2

Maximum28 ft. (8.5m)

Vent Restrictor on Set 1

  • Vent must be supported at offsets.
  • Firestops are required at each fl oor level and whenever passing through a wall.
  • Maintain clearances to combustibles as listed in the "Clearances" section.
  • Refer to "Vent Restrictor Position" section for details on how to change the vent restrictor to Set 1 or Set 2 if required.

Minimum 8’9” (2.6m)

Rigid Pipe (Part # 770-994).

Max. 10’ (3m)(centerline to centerline) Minimum 12” (305mm)

Vertical Height (Feet) · Vent Restrictor · Factory Set

Page 21 of the Regency P40 user manual — WITH HORIZONTAL
Page 21 · click to enlarge
Page 21

UNIT INSTALLATION

6. Mark the wall for a 11" x 11" (279mm x 279mm) square hole. The center of the square hole should line up with the centerline of the horizontal pipe. Cut and frame the 11 inch (279mm) square hole in the exterior wall where the vent will be terminated. See diagram 2 for center line requirements.
Regency P40 — UNIT INSTALLATION diagram (page 21)
Fig. 17

WITH HORIZONTAL

TERMINATION (Rigid Vent Systems)

Install the vent system according to the manufacturer's instructions included with the components.

If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable.

1. Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.
Regency P40 — WITH HORIZONTAL diagram (page 21)
Fig. 18

The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

2. Direct Vent pipe and fi ttings are designed with special twist-lock connections to connect the venting system to the appliance fl ue outlet. A twist-lock appliance adaptor is required.
8. Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble (Part # 1247) over the vent pipe, required in Canada.
3. In conjunction with the Simpson Dura-Vent Direct Vent GS system. Install the adaptor after the unit is set in its desired location. Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar. Slip the adapter over the existing inner and outer fl ue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier).

9) Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap suffi cient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe section. See Diagram 6.

4. Level the fi replace and fasten it to the framing using nails or screws through the top and side nailing strips.

or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fi re. The arrow on the vent cap should be pointing up.

5. Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection.
Regency P40 — WITH HORIZONTAL diagram (page 21)
Fig. 19

b) The location of the horizontal vent

and high temp silicone sealant to outer pipe on every twist-lock joint.

termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations"

7. Insure that the 1-1/4"(32mm) pipe clearances to combustible materials are maintained (Diagram 5). Install the termination cap.

siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.

10. Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7).

Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.

Show 4 more labels / short text on this page
Diagram 5 · Diagram 2 · Diagram 1 · Diagram 7
Page 22 of the Regency P40 user manual — Offset Chart
Page 22 · click to enlarge
Page 22

UNIT INSTALLATION

4. Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed.
Regency P40 — UNIT INSTALLATION diagram (page 22)
Fig. 20

WITH VERTICAL

TERMINATION (Rigid Vent Systems)

Regency P40 — WITH VERTICAL diagram (page 22)
Fig. 21
1. Maintain the 1-1/4" (32mm) clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check "Venting Arrangemnt - Vertical Termination" section for the maximum vertical rise of the venting system and the maximum horizontal offset limitations.
5. Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2. The hole should be of suffi cient size to meet the minimum requirements for clearance to combustibles of 1-1/4"(32mm). Slip the fl ashing under the shingles (shingles should overlap half the fl ashing) as per Diagram 4.

2) Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance fl ue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at his point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters or other framing will obstruct the venting system. You may wish to relocate the appliance or to offset, as shown in Diagram 2 to avoid cutting load bearing members.

A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.

Regency P40 — WITH VERTICAL diagram (page 22)
Fig. 22
7. Ensure vent is vertical and secure the base of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and seal with a mastic.
8. Install the vertical termination cap by twistlocking it.
Diagram 4The upper half of the fl ashing is

the vent passes through must be enclosed.

Offset Chart

6. Continue to assemble pipe lengths.
Regency P40 — Offset Chart diagram (page 22)
Fig. 23 · Offset Chart
3. A Firestop spacer must be installed in the fl oor or ceiling of every level.

to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose (Diagram 2). Galvanized pipe is desirable above the roofl ine due to its higher corrosion resistance. Continue to add pipe sections through the fl ashing until the height of the vent cap meets the minimum height requirements specifi ed in Diagram 5 or local codes. Note that for steep roof pitches, the vertical height must be increased. Diagram 3

Regency P40 — Offset Chart diagram (page 22)
Fig. 24 · Offset Chart

Diagram 2

Page 23 of the Regency P40 user manual — HORIZONTAL TERMINATION
Page 23 · click to enlarge
Page 23

UNIT INSTALLATION

4. Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.

HORIZONTAL TERMINATION

WITH FLEX VENT SYSTEM

1. Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left. Locate the centerline of the termination and mark wall accordingly. Cut an 11"(279mm) hole in the wall (inside dimension).
5. Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.
Regency P40 — HORIZONTAL TERMINATION diagram (page 23)
Fig. 25

and side & bottom clearance of 1-1/2"(38mm) must be maintained except that only a 1" (25mm) clearance is needed at the termination end. We recommend framing a 11"(279mm) x 11"(279mm) (inside dimensions) hole to give structural rigidity for mounting the termination.

6. Pull the centre 5"(127mm) liner and outer 8"(203mm) liner out enough to slip over the fl ue collars of the fi replace. (You may wish to cut the liner shorter to make it more workable.) Do not bend liner more than 90 o . The liners must slip over the collars a minimum of 1-3/8".
Regency P40 — HORIZONTAL TERMINATION diagram (page 23)
Fig. 26
7. Apply Mill Pac over the fi replace inner collar and slip the 5"(127mm) liner down over it and attach with 3 supplied screws.
8. Do the same with the 8"(203mm) liner.
9. Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the water out.

covered wall, a vinyl siding standoff or vinyl furring strips must be used to ensure that the termination is not recessed into the siding.

Regency P40 — HORIZONTAL TERMINATION diagram (page 23)
Fig. 27
2. Level the fi replace and fasten it to the framing using nails or screws through the nailing strips.
3. Assemble the vent assembly by applying Mill Pac to the 5"(127mm) inner collar of the termination and slipping the 5"(127mm) liner over it at least 1-3/8" (35mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill Pac or high temperature silicone to the 8"(203mm) fl ex pipe and slip it over the 8" outer collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws.
Page 24 of the Regency P40 user manual — HIGH ELEVATION
Page 24 · click to enlarge
Page 24

GAS LINE INSTALLATION

PILOT ADJUSTMENT

P40-NG SYSTEM DATA

For 0 to 4500 feet altitude Front Burner Orifi ce: #44 Back Burner Orifi ce: #35 Max. Input Rating 45,000 Btu/h Min. Input Rating 13,000 Btu/h

The gas line can be brought through the bottom right of the appliance. The gas valve is situated on the bottom of the unit.

The gas line connection may be made of rigid pipe, copper pipe or an approved fl ex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.

Supply Pressure min.5.0" w.c. Manifold Pressure (High) 3.5"+/- 0.3"w.c.

Periodically check the pilot fl ames. Correct fl ame pattern has three strong blue fl ames: 1 fl owing around the thermopile, 1 around the thermocouple and 1 fl owing across the burner (it does not have to be touching the burner).

Log Set: Ceramic fi bre, 8 per set + ember bed. Vent System: Simpson Dura-Vent Direct Vent System, Regency® Flex Kit, Selkirk Direct-Temp

For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or fl ex connectors use only approved fi ttings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and fl ex connectors are usually considered to meet this requirement.

P40-LP SYSTEM DATA

contact your Regency® dealer for further instructions.

Incorrect fl ame pattern will have small, probably yellow fl ames, not coming into proper contact with the rear burner or thermopile or thermocouple.

For 0 to 4500 feet altitude Front Burner Orifi ce: #55 Back Burner Orifi ce: #53 Max. Input Rating 43,000 Btu/h Min. Input Rating 12,000 Btu/h

Supply Pressure min.12.0" w.c.

Manifold Pressure (High) 10"+/- 0.5" w.c.

Log Set: Ceramic fi bre, 8 per set + ember bed. Vent System: Simpson Dura-Vent Direct Vent System, Regency® Flex Kit, Selkirk Direct-Temp

HIGH ELEVATION

This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M91).

Conversion Kit# 502-969

Page 25 of the Regency P40 user manual — SIT VALVE DESCRIPTION
Page 25 · click to enlarge
Page 25

GAS PIPE PRESSURE

SIT VALVE DESCRIPTION

BACK-UP BATTERY

TESTING

INSTALLATION (within Power Module)

1. Gas on/off knob 2) Electronically Operated Hi/Lo 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.

The 9V battery operates the rear burner and the AA battery operates the DC Sparker for lighting the pilot under power outage conditions.

The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

Regency P40 — SIT VALVE DESCRIPTION diagram (page 25)
Fig. 28
1. Unplug the power source.
2. Remove the Power Module by lifting it up off of the velcro and pull out.

inlet and manifold pressures should be checked using the valve pressure ports on the valve.

Regency P40 — SIT VALVE DESCRIPTION diagram (page 25)
Fig. 29
1. Make sure the valve is in the "OFF" position.
2. Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide fl at screwdriver.
Regency P40 — SIT VALVE DESCRIPTION diagram (page 25)
Fig. 30
3. Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.
4. Light the pilot and turn the valve to "ON" position.
3. Remove the Power Module cover by removing the 2 screws, one on each side of the box.
5. The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label.
Regency P40 — SIT VALVE DESCRIPTION diagram (page 25)
Fig. 31
6. When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. Note: Screw should be snug, but do not over tighten.
4. Install the 9V and AA battery.
Regency P40 — SIT VALVE DESCRIPTION diagram (page 25)
Fig. 32

Power Module

Page 26 of the Regency P40 user manual — CONVERSION KIT #502-969 FROM NG TO LP
Page 26 · click to enlarge
Page 26

CONVERSION KIT #502-969 FROM NG TO LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

6. Slide the burner to the right and lift out.
11. Remove the clip from the pilot head assembly using a fl at head screw driver to pop out.

LP Conversion Kit Contains:

7. Remove the front burner by removing the 2 screws. Lift the burner up and swing to the right and slide out.

Qty. Part # Description 1 910-462 LP Conversion Coil 1 910-037 LP Pilot Orifi ce 1 904-345 Orifi ce #53 1 904-575 Orifi ce #55 1 904-529 Allen Key 1 918-590 LP Conversion Decal 1 908-528 Red Propane Label 1 918-587 Instruction Sheet

Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 33
Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 34
1. Turn control knob to the OFF position; Shut off the gas supply to the valve; Unplug the power source.
8. Replace the rear burner orifi ce with #53, using a 1/2" wrench. See image below. Use another wrench to hold onto the elbow behind the orifi ce.
2. Remove the louvers and the fl ush door.
12. Remove the NG pilot orifi ce with the Allen Key and replace with LP pilot orifi ce. Reattach pilot head and clip.
3. Remove the logs.
9. Replace the front burner orifi ce with #55, using a 1/2" wrench. See image below. Use another wrench to hold onto the elbow behind the orifi ce.
4. Remove the front air box by undoing the 3 screws.
Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 35
Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 36
Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 37
5. Remove the 2 screws on the back burner.
13. Re-install pilot shield.
Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 38
14. Set aeration on both front and rear burner for LP gas; Rear 5/16" Front 3/8"
10. Remove the pilot shield by removing the 2 screws.
Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 39
15. Reverse steps 7 to 4.
16. Remove the Power Module by lifting it up off of the velcro and move it over to the side.
Regency P40 — CONVERSION KIT #502-969 FROM NG TO LP diagram (page 26)
Fig. 40
Show 10 more labels / short text on this page
Front Burner · Clip · Front Air Box · Front Burner · Rear Burner · Orifi ce · Orifi ce · Back Burner · Pilot Shield · Power Module
Page 27 of the Regency P40 user manual — Installer Notice: These instructions must be left
Page 27 · click to enlarge
Page 27
17. Remove the Control Module, located behind the power module, by lifting it up off of the velcro.
21. Using a Torx T20, or slotted screwdriver, remove and discard the three pressure regulator mounting screws and rubber diaphram.

WARNING! This conversion kit should be installed by a qualifi ed service agency in ac- cordance with the authority having jurisdiction. If the information in these instructions are not followed exactly, a fi re, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualifi ed service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the con- verted appliance is checked as speci- fi ed in the manufacturer's instructions supplied with the kit.

Regency P40 — Installer Notice: These instructions must be left diagram (page 27)
Fig. 41 · Installer Notice: These instructions must be left
22. Insure that the new rubber gasket is properly positioned and install the new modulating pressure regulator assembly to the valve using the screws supplied with the kit. Tighten screws securely.
23. Reattach 2 wires to modulating coil.
24. Install the enclosed identifi cation label to the valve body where it can be easily seen. The label is found in the coil package.
18. Remove the J9 jumper using needle nose pliers, located under the heat shield.
25. Attach the LP conversion decal near or on top of the serial # decal located on a metal plate under the unit.
Regency P40 — Installer Notice: These instructions must be left diagram (page 27)
Fig. 42 · Installer Notice: These instructions must be left

Installer Notice: These instructions must be left

26. Replace the yellow "Natural Gas" label with the red "Propane" label on the valve assembly.

with the appliance.

27. Ensure proper installation of venting is complete, gas line is connected and then turn on power to unit.
28. Check for gas leaks.
29. Check inlet (12" wc) and outlet (10" wc) pressures.
30. Check operation of fl ame control using the manual control box located on the right side under the fi rebox.
19. Reverse steps 17 and 16. Be careful not to pinch wires.
31. Re-install logs and fl ush door. Check for proper fl ame appearance and glow on logs.
20. Remove the 2 wires connected to the modulating coil.
Regency P40 — Installer Notice: These instructions must be left diagram (page 27)
Fig. 43 · Installer Notice: These instructions must be left

Control Module · J9 Jumper · Modulating Coil

Page 28 of the Regency P40 user manual — BRICK PANEL INSTALLATION
Page 28 · click to enlarge
Page 28

BRICK PANEL INSTALLATION

Must install 1 set of brick panels with the P40.

1. Unwrap the Brick Panels from the protective wrapping.
6. Place the Top Brick Panel over the back brick panel and secure with the top brick panel bracket.
2. Ensure that the logs are not in the unit.
3. Place the 2 small Back Brick Panels at the base of the fi rebox on the left and right side of the burner assembly.
Regency P40 — BRICK PANEL INSTALLATION diagram (page 28)
Fig. 44
Regency P40 — BRICK PANEL INSTALLATION diagram (page 28)
Fig. 45
7. Remove the screw on the left side of the fi rebox. Place the left side brick panel in position and secure using the brick tab and screw. Repeat for right side brick panel.

Left Side Small Back Brick Panel

Right Side Small Back Brick Panel

Regency P40 — BRICK PANEL INSTALLATION diagram (page 28)
Fig. 46
4. Insert the Back Brick Panel by slipping it between the back wall of the fi rebox and the burner assembly, sitting it on the small back brick panels installed in step 3.
Regency P40 — BRICK PANEL INSTALLATION diagram (page 28)
Fig. 47

Brick Panels Completely Installed

Regency P40 — BRICK PANEL INSTALLATION diagram (page 28)
Fig. 48
5. Remove the Top Brick Panel Bracket by removing the 3 screws.
Regency P40 — BRICK PANEL INSTALLATION diagram (page 28)
Fig. 49
Show 5 more labels / short text on this page
Top Brick Panel · Bracket · Top Brick Panel · Brick Tab · Back Brick Panel
Page 29 of the Regency P40 user manual — LOG SET INSTALLATION
Page 29 · click to enlarge
Page 29

LOG SET INSTALLATION

Read the instructions below carefully and refer to the pictures. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

4. Re-install the brackets removed in step 2 to hold the log in place.
Regency P40 — LOG SET INSTALLATION diagram (page 29)
Fig. 50

Log kit (Part # 502-930) contains the following pieces:

a) 03-32 Back Log b) 03-40 Ember Bed c) 03-34 Front Left Log d) 03-33 Middle Back Log e) 03-35 Middle Left Cross Log f) 03-36 Middle Right Cross Log g) 03-37 Front Right Log h) 03-38 Right Side Ember Bed i) 03-38 Left Side Ember Bed j) 902-154 Embers Lava k) 902-179 Vermiculite

5. Place the Ember Bed on the 2 tabs located on the front burner. Then slide the ember bed to the right until it touches the burner tube.
Regency P40 — LOG SET INSTALLATION diagram (page 29)
Fig. 51
Regency P40 — LOG SET INSTALLATION diagram (page 29)
Fig. 52
Regency P40 — LOG SET INSTALLATION diagram (page 29)
Fig. 53
1. Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.
2. Remove the brackets on the left and right side of the back air box.
Regency P40 — LOG SET INSTALLATION diagram (page 29)
Fig. 54

Ember Bed Burner Tube

3. Fit log 03-32 into the pins on the back air box. Push the log tight against the back brick panel.
Show 7 more labels / short text on this page
03-36 03-37 · Front Burner · 03-33 03-35 · 03-38 Left · 03-32 03-38 Right · Back Air · Box
Page 30 of the Regency P40 user manual — LOG SET INSTALLATION
Page 30 · click to enlarge
Page 30
8. Place log 03-33 on the back burner in between the burner tubes. Slide the log to the left until it touches the end of the burner tube.
6. Spread the embers along the ember tray on the inside of the fender as shown.
Regency P40 — LOG SET INSTALLATION diagram (page 30)
Fig. 55
Regency P40 — LOG SET INSTALLATION diagram (page 30)
Fig. 56
Regency P40 — LOG SET INSTALLATION diagram (page 30)
Fig. 57
9. Place the bottom of log 03-35 onto the 2nd fender post and fi t the top of log 03-35 into the pin on the left side of log 03-33.
Regency P40 — LOG SET INSTALLATION diagram (page 30)
Fig. 58
7. Fit log 03-34 into the 1st left side Fender Post and rest on the ember bed.
Regency P40 — LOG SET INSTALLATION diagram (page 30)
Fig. 59
10. Place the end of log 03-36 on the 3rd fender post and fi t the top of log 03-36 into the pin on the right side of log 03-33.
Regency P40 — LOG SET INSTALLATION diagram (page 30)
Fig. 60
Regency P40 — LOG SET INSTALLATION diagram (page 30)
Fig. 61
Show 11 more labels / short text on this page
Burner · Tube · Ember Tray · Pin · 03-35 03-33 · 2nd Fender Post · 1st Fender Post · Pin · 03-36 03-33 · 3rd Fender Post · Ember Bed
Page 31 of the Regency P40 user manual — Completed Log Set Installation
Page 31 · click to enlarge
Page 31
11. Fit log 03-37 on the 4th fender post and rest on the notch in log 03-33.
13. Place log 03-38 Right on the right side of the ember bed inbetween log 03-37 and log 03-36.
Regency P40 — Completed Log Set Installation diagram (page 31)
Fig. 62 · Completed Log Set Installation
Regency P40 — Completed Log Set Installation diagram (page 31)
Fig. 63 · Completed Log Set Installation

Ember Bed 03-38 Right

14. Spread the bag of vermiculite on the exposed base brick.
12. Place log 03-38 Left on the left side of the ember bed inbetween log 03-34 and log 03-35.
Regency P40 — Completed Log Set Installation diagram (page 31)
Fig. 64 · Completed Log Set Installation

Ember Bed 03-38 Left

Completed Log Set Installation

Regency P40 — Completed Log Set Installation diagram (page 31)
Fig. 65 · Completed Log Set Installation

Ember Bed 03-38 Left 03-38 Right

Show 5 more labels / short text on this page
03-37 03-36 · 4th Fender Post · 03-34 03-35 · 03-36 03-35 · 03-32 03-33
Page 32 of the Regency P40 user manual — AERATION ADJUSTMENT
Page 32 · click to enlarge
Page 32

AERATION ADJUSTMENT

STANDARD FLUSH DOOR

FLUSH LOUVERS

Aeration Adjustment should only be per- formed by an authorized Regency® Installer at the time of installation or service.

1. Install the top louver by sliding the two bracket clips into the brackets located underneath the top of the fi rebox.
1. The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1.
Regency P40 — AERATION ADJUSTMENT diagram (page 32)
Fig. 66

The rear burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

2. Install the bottom louver by securing the louver onto the 2 hinges provided.

The rear burner air shutter can be adjusted by moving the air shutter wire. Open (pull) the air shutter wire for a blue fl ame or close (push) for a more yellow fl ame.

Regency P40 — AERATION ADJUSTMENT diagram (page 32)
Fig. 67

* The front burner aeration is factory set, do not adjust this setting.

Minimum Air Shutter Opening:

NG Front Burner* 1/8" Rear Burner 1/4"

LP Front Burner* 3/8" Rear Burner 5/16"

resulting from improperly setting the aeration controls is NOT covered under warranty.

3. Installing the Manual Control Box
2. Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

a) Ensure that the bottom louver is open.

Regency P40 — AERATION ADJUSTMENT diagram (page 32)
Fig. 68

b) Pull out the Manual Control Box from the

right side under the bottom of the fi rebox.

c) Using the 2 screws on the louver, secure

the control box onto the right side of the louver.

Regency P40 — AERATION ADJUSTMENT diagram (page 32)
Fig. 69

Rear Burner Adjustment Wire

Adjustment Wire - Pull to open or

3. Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3.

push to close aeration cap.

be OVER not under the gas line.

4. To remove the fl ush door, reverse the above steps.
Show 4 more labels / short text on this page
Diagram 1 · Diagram 2 · Manual Control Box · Diagram 3
Page 33 of the Regency P40 user manual — WIRING DIAGRAM
Page 33 · click to enlarge
Page 33
Regency P40 — WIRING DIAGRAM diagram (page 33)
Fig. 70
1. Install the Finishing Trim sides as shown in diagram 1, line up the holes in the side trim with the holes in the fi rebox side.
3. Loosen the 3 screws in the top inside edge of the fi rebox.
4. Slide the Finishing Trim Top over the Side Trim pieces and fi t the bottom bracket slots over the screws. Tighten the 3 screws to secure. Diagram 1

WIRING DIAGRAM

A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully. The front and rear burners will operate on low, when the unit is running on battery back-up.

(Do not cut the ground terminal off under any circumstances.)

Regency P40 — WIRING DIAGRAM diagram (page 33)
Fig. 71
Page 34 of the Regency P40 user manual — IMPORTANT To ignite or reignite the pilot,
Page 34 · click to enlarge
Page 34

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

1. Push in gas control knob slightly and turn clockwise to “OFF”. Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

FIRST FIRE

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

1. Read and understand these instructions before operating this appliance.
2. Wait fi ve (5) minutes to clear out any gas.
2. Check to see that all wiring is correct and enclosed to prevent possible shock.
3. Turn knob on gas control counterclockwise to “PILOT”.

The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on.

4) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 1) to 4). If knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

3. Check to ensure there are no gas leaks.
4. Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

When fi rst operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

5. Verify that the venting and cap are unobstructed.
6. Ensure that the brick panels are installed.
7. Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

OPERATION

5. Turn gas control knob counterclock-wise to “ON”.

"HIGH" and resume it's last setting after 20 seconds of operation.

6. Turn the unit on.
8. The unit should never be turned off, and on again without a minimum of a 60 second wait.

is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

LIGHTING PROCEDURE

SHUTDOWN PROCEDURE

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

IMPORTANT To ignite or reignite the pilot,

1. Press the ON/OFF switch once.

During the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Only when the pilot holds, without pressure being applied to the control knob, reapply the tension springs to the door. The unit must not be operated with the tension springs unattached.

2. The LED will fl ash.

you must fi rst release the tension springs below the door.

3. Turn the main gas control clockwise to the "OFF" position to turn off the pilot.
4. Turn off all electric power to appliance if service is to be performed.

Ensure that the 3 way switch on the manual control panel is in the "Remote" position.

Regency P40 — IMPORTANT To ignite or reignite the pilot, diagram (page 34)
Fig. 72 · IMPORTANT To ignite or reignite the pilot,

Manual Control Panel · 3-way Switch

Page 35 of the Regency P40 user manual — CONTROLS
Page 35 · click to enlarge
Page 35

OPERATING INSTRUCTIONS

OPERATION DURING

When in "Manual" position; In the event of a power failure, if the 3-way switch is in the "Manual" position the front buner will remain on at the lowest setting and will remain on when power resumes. If the rear burner is not in use, to operate see "Rear Burner Opera- tion" above.

Regency P40 — OPERATING INSTRUCTIONS diagram (page 35)
Fig. 73

POWER OUTAGE

Both burners when on will operate at the lowest fl ame setting. The BTU's for NG will be 13,000 and 12,000 for LP.

When power resumes the unit will remain on at the lowest setting until reset using the remote control.

3-way switch on the Manual Control Panel to the "Remote" position to be able to use the FireWizardTM Remote Control.

FIREWIZARD TM REMOTE

OPERATION

SUMMARY OF

CONTROL FUNCTIONS The FireWizardTM Remote Control was de- veloped to provide a user-friendly system to operate your appliance. The operating range is approximately 10 metres (32 feet) from the fi replace.

CONTROLS

For the Manual Control Box, located on

right hand side of the bottom louver.

When in "Remote" position; In the event of a power failure, if the 3-way switch is in the "Remote" position, the unit cannot be operated with the Remote Control until after power is restored.

See FireWizard Remote Control Manual for complete details on operation functions and instructions.

On/Off Button If the unit is off, pressing and releasing this button once will switch the unit on. The unit will be on high for 20 seconds and then resume to its last settings.

To operate unit during a power failure;

Regency P40 — CONTROLS diagram (page 35)
Fig. 74

If the unit is on, pressing and releasing this button once will switch the unit off.

lowest fl ame setting. The BTU's for NG will be 13,000 and 12,000 for LP.

Flame: There are seven fl ame settings that can be adjusted by pressing and releasing the plus (+) and minus (-) FLAME button.

Front Burner Operation: 1) Open the bottom louver to gain access to the Manual Control Panel. 2) To turn on the front burner, change the 3-way switch to "Manual" position.

Increase: If the unit is on, pressing and releasing the fl ame plus (+) button once will increase the fl ame height to the next available high setting.

Rear Burner Operation: 1) Open the bottom louver to gain access to the Manual Control Panel. 2) To turn on the rear burner, change the Rear Burner Switch to the "On" position. Changing the switch to the "Off" postion will turn the rear burner off.

Decrease: If the unit is on, pressing and releasing the fl ame minus (-) button once will decrease the fl ame height to the next available low setting.

Fan: There are three fan speeds that can be adjusted by pressing and releasing the plus (+) and minus (-) FAN button.

Pressing and releasing the plus (+) FAN button will change the fan speed as follows:

OFF -> LOW -> MEDIUM -> HIGH -> OFF

Pressing and releasing the minus (-) FAN button will be the reverse of the above.

Show 8 more labels / short text on this page
Unit On/Off Button · Fan Control · Buttons · Flame Control Buttons · Manual Control Panel · Manual Control Box · Switch 3-way Switch · Rear Burner
Page 36 of the Regency P40 user manual — DO NOT REMOVE THIS INSTRUCTION PLATE
Page 36 · click to enlarge
Page 36

OPERATING INSTRUCTIONS

COPY OF LIGHTING PLATE INSTRUCTIONS NORMAL OPERATING

SOUNDS OF GAS APPLIANCES

It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes,

CSA B149.1. (AustraliaAS5601-2004, New Zealand: NZS 5261)

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

Blower: Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the speed setting of your fan speed control.

A) This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these

instructions exactly.

B) BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the fl oor

because some gas is heavier than air and will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

- Do not try to light any appliance. - Do not touch any electric switch, do not use any phone in your building. - Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s

OPERATION

instructions. - If you cannot reach your gas supplier, call the fi re department.

Burner Tray: The burner tray is positioned directly under the burner tube and logs and is made of a different gauge material from the rest of the fi rebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.

C) Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not

push in or turn by hand, don’t try to repair it, call a qualifi ed service technician. Forced or attempted repair may result in a fi re or explosion.

D) Do not use this appliance if any part has been under water. Immediately call a qualifi ed service

technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

E) This appliance needs fresh air for safe operation and must be installed so there are provisions for

adequate combustion and ventilation air.

Pilot Flame: While the pilot fl ame is on it can make a very slight "whisper" sound.

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this label.

Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

1. Push in gas control knob slightly and turn clockwise to “OFF”. Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

PILOT BURNER

VEILLEUSE OFF

Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

THERMOPILE

ELEMENT THERMOELECTRIQUE

2. Wait fi ve (5) minutes to clear out any gas. If you then smell gas STOP! Follow step “B” in the Safety Information above on this label. If you don’t smell gas, go to the next step. 3) Turn knob on gas control counterclockwise to“PILOT”.

4) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 1) to 4). If knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 5) Turn gas control knob counterclock-wise to “ON”.

6. Turn the unit on.

TO TURN OFF GAS APPLIANCE

1. Turn off the unit. 2) Push in the gas control knob slightly and turn clockwise to “OFF”. Do not force. 3) Turn off all electric power to the appliance if service is to be performed. You may shut off the pilot during prolonged non use periods to conserve fuel.

DO NOT REMOVE THIS INSTRUCTION PLATE

918-583

Page 37 of the Regency P40 user manual — MAINTENANCE
Page 37 · click to enlarge
Page 37

MAINTENANCE

MAINTENANCE INSTRUCTIONS

GENERAL VENT

THERMOPILE / THERMOCOUPLE

MAINTENANCE

Conduct an inspection of the venting system semiannually. Recommended areas to inspect as follows:

1. Open the Bottom Louver and remove the Top Louver.
1. Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.
2. Open and remove door.
1. Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately. 2) Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.
3. Remove log set.
4. Remove grate and burner.
2. Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fi replace glass cleaner. The glass should be cleaned when it starts looking cloudy.
5. Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Disconnect thermopile by loosening 2 screws marked TP on the valve.
3. Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.
6. Remove 2 screws from the pilot assembly and pull up far enough to be able to loosen the thermocouple or thermopile with a 7/16" wrench. NOTE: the pilot line is very fragile, use caution when pulling it up.
3. The heater is fi nished in a heat resistant paint and should only be refi nished with heat resistant paint. Regency ® uses StoveBright Paint - Metallic Black #6309.
7. Drop the thermocouple or thermopile down through the extrusion and pull it out of the unit.
4. Make a periodic check of burner for proper position and condition. Visually check the fl ame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed service person.
4. Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.
8. Reinstall the new ones in reverse order.
5. The appliance and venting system must be inspected before use, and at least annually, by a qualifi ed fi eld service person, to ensure that the fl ow of combustion and ventilation air is not obstructed.

GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-155).

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.) If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagrams under Log Installation.

LOUVERS

the glass properly secured in place.

MAINTENANCE

6. Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

The finish on the louvers require little maintenance, and need only be cleaned with a damp cloth.

DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

7. In the event this appliance has been serviced, check that the vent-air system has been properly resealed & reinstalled in accordance with the manufacturer's instructions.

create carbon build-up and will severely alter the unit's performance which is not covered under warranty.

Clean any fi ngerprints off before turning the unit on.

8. Verify operation after servicing.
Page 38 of the Regency P40 user manual — J1 J2 J3
Page 38 · click to enlarge
Page 38

MAINTENANCE

FAN REPLACEMENT

DOOR GLASS

6. Remove the fan ground wires.

Your Regency® fi replace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials.

1. Unplug the power source.
Regency P40 — MAINTENANCE diagram (page 38)
Fig. 75
2. Remove the power module by lifting it up off of the velcro and pull out.
Regency P40 — MAINTENANCE diagram (page 38)
Fig. 76

CAUTION & WARNINGS:

* Do not clean when the glass is hot. * The use of substitute glass will void all product warranties. * Care must be taken to avoid breakage of the glass. * Do not strike or abuse the glass. * Do not operate this fi replace without the glass front or with a cracked or broken glass front. * Wear gloves when removing damaged or broken glass. * Replacement of the glass panel(s) should be done by a licensed or qualifi ed service per son.

7. Disconnect the brown and blue wires connected to the J1 harness.
3. Undo the wire holder by releasing tab.
Regency P40 — CAUTION & WARNINGS: diagram (page 38)
Fig. 77
Regency P40 — CAUTION & WARNINGS: diagram (page 38)
Fig. 78

GLASS REPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only.

Replacement glass is shipped already installed into the door frame. Reinstall as per Glass Door Installation in "Standard Flush Door" section.

8. Release the 2 wire tabs.
9. Remove both fans by lifting up off of the pins and tilt sideways and then slide to the left of the fi rebox and pull out carefully.
4. Remove the Control module by lifting it up and off to the side.

MAINTENANCE

Regency P40 — MAINTENANCE diagram (page 38)
Fig. 79
Regency P40 — MAINTENANCE diagram (page 38)
Fig. 80
10. Reverse steps to re-install.
5. Unplug the J1, J2 and J3 harness at the ECS module and pull out the Control module.
Regency P40 — MAINTENANCE diagram (page 38)
Fig. 81

J1 J2 J3

Power Module · Control Module

Page 39 of the Regency P40 user manual — MAINTENANCE
Page 39 · click to enlarge
Page 39

MAINTENANCE

VALVE REPLACEMENT

1. Shut off the main gas supply and unplug the power to the ECS system.
7. Carefully remove the base brick panel.
12. Unplug the 5 wires at the valve (2 grey, 2 red and 1 black.
8. Remove the 2 screws on the back burner.
2. Remove the main gas line pipe from the gas valve.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 82
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 83
3. Remove logs and brick panels if installed.
4. Remove the fender by undoing the 2 screws, one on the left and right side.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 84
13. Reach in and grab the black and red wires leading to the solenoid valve and disconnect them.
9. Slide burner to the right and lift out.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 85
10. Remove back air box by removing 2 screws, one on the left and one on the right side and pull out.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 86
5. Remove the front air box by undoing the 3 screws.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 87
14. Remove all 22 valve tray screws and carefully lift out the valve tray.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 88

MAINTENANCE

11. Unplug the 3 black wires at the DC Sparker.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 89
6. Remove the front burner by removing the 2 screws and swing the burner to the left and slide out.
Regency P40 — MAINTENANCE diagram (page 39)
Fig. 90
Show 5 more labels / short text on this page
Back Burner · Fender · Back Burner · Solenoid Valve · Front Air Box
Page 40 of the Regency P40 user manual — MAINTENANCE
Page 40 · click to enlarge
Page 40

MAINTENANCE

15. Disconnect the compression fi tting at the solenoid valve.

DC SPARKER REPLACEMENT

5. Unplug pilot knob wires (Wa and Wb) and ignitor wire (Vu).
16. Remove the solenoid valve from the main valve.
1. Unplug the power source.

Wa & Wb Wires Vu Wires

Regency P40 — DC SPARKER REPLACEMENT diagram (page 40)
Fig. 91
2. Remove the manual control panel by removing the 2 screws.
Regency P40 — DC SPARKER REPLACEMENT diagram (page 40)
Fig. 92
Regency P40 — DC SPARKER REPLACEMENT diagram (page 40)
Fig. 93
6. Replace the DC Sparker and reverse steps to re-install.
17. Disconnect the thermopile wires (TP/TH & TP) from the valve. See image below.
3. Remove the DC Sparker by removing the 2 screws that secure the DC Sparker to the fi rebox and lift out.
18. Undo the pilot tube from the valve with a 7/16" wrench. See image below.
Regency P40 — DC SPARKER REPLACEMENT diagram (page 40)
Fig. 94
19. Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.
Regency P40 — DC SPARKER REPLACEMENT diagram (page 40)
Fig. 95

MAINTENANCE

4. Remove the cover on the DC Sparker and unplug the red (+) and black (-) wires.

fi t behind the metal posts when re- installing.

20. Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve.
Show 10 more labels / short text on this page
Solenoid Valve · Manual Control Panel · Compression Fittings · DC Sparker · Thermopile · Thermocouple · Pilot Nut · Wire · Wire · Ring Tabs
Page 41 of the Regency P40 user manual — J3
Page 41 · click to enlarge
Page 41

MAINTENANCE

6) Replace the Control Module and reverse steps to re-install. POWER MODULE

CONTROL MODULE

REPLACEMENT

REPLACEMENT

BACKUP BATTERY

1. Unplug the power source.
1. Unplug the power source.

REPLACEMENT (within Power Module)

2. Remove the Power Module by lifting it up off of the velcro and pull out.
2. Remove the Power Module by lifting it up off of the velcro and pull out.

burner and the AA battery operates the DC Sparker for lighting the pilot under power outage conditions.

1. Unplug the power source.
2. Remove the Power Module by lifting it up off of the velcro and pull out.
3. Remove the Power Module cover by removing the 2 screws, one on each side of the box.
3. Remove the Control Module by lifting it up off of the velcro and pull out.
Regency P40 — REPLACEMENT (within Power Module) diagram (page 41)
Fig. 96 · REPLACEMENT (within Power Module)
3. Remove the Power Module cover by removing the 2 screws, one on each side of the box.
4. Remove the Heat Shield from the Control Module by removing the 2 screws.
4. Unplug all wires connected to the Power Module (J1, J2 & J3 on the power module circuit board).

MAINTENANCE

Regency P40 — MAINTENANCE diagram (page 41)
Fig. 97
Regency P40 — MAINTENANCE diagram (page 41)
Fig. 98

J3

J2

J1

4. Replace the 9V and AA battery and reverse steps to re-install.
5. Unplug all wire harnesses and manual control box cable plugged into the Control module.
5. Pull Power Module off of pins and replace.
Regency P40 — J3 diagram (page 41)
Fig. 99
6. Reverse steps to re-install.
Show 5 more labels / short text on this page
Power Module · Power Module · Power Module · Control Module · Heat Shield
Page 42 of the Regency P40 user manual — PARTS LIST
Page 42 · click to enlarge
Page 42

PARTS LIST

MAIN ASSEMBLY

Part # Description 10) 502-528 Brick Panel Base (Set of 3)

Part # Description 910-930 FireWizardTM Remote Control 918-582 Manual FireWizardTM

502-901 Brick Panel Set Standard Brown 502-902 Brick Panel Set Standard Red 11) 502-040 Cast Iron Fender 502-075 Front Ember Tray

910-215/P Fan 115 Volt / 110 Cfm (dual blower) 910-073 Spark Generator Battery Holder 910-074 Spark Generator Swtch C/W Wire

910-813 Power Cord 120Vlt Plug in Fan

12. 502-033 Burner Front Cover 13) 948-450 Burner Tube Front NG/LP 14) 948-451 Burner Tube Rear NG/LP 15) 502-009 Log Tray

910-927 Wire Harness Twin Fan 910-928 Wire Harness Solenoid Switch 910-939 Wire Sparker - Combo Drive

502-930 Log Set - (Oak)

910-935 Switch Manual Control 910-528 Wire - 54 in.

16. 502-016 Top Brick Clip
20. 910-929 Control Module 21) 910-931 Power Module
Regency P40 — PARTS LIST diagram (page 42)
Fig. 100

PARTS LIST

918-566 Manual

Page 43 of the Regency P40 user manual — PARTS LIST
Page 43 · click to enlarge
Page 43

PARTS LIST

VALVE TRAY ASSEMBLY

120. 904-644 Orifi ce # 35 121) 904-568 Orifi ce # 44 122) 910-008 Pilot Assembly
125. 910-460 Valve NG - SIT 825 126) 910-937 Valve Solenoid - 3 Volt 127) 910-928 Wire Harness Solenoid Switch 128) 910-925 Wire Harness J2 910-924 Wire Harness J1 910-926 Wire Harness J3

502-574/P Valve Assembly - NG 502-576/P Valve Assembly - LP 502-969 Conversion - LP

PARTS LIST

Part # Description

Page 44 of the Regency P40 user manual — PARTS LIST
Page 44 · click to enlarge
Page 44

PARTS LIST

FLUSH DOOR & LOUVERS

Part # Description 502-910 Flush Louvers (Set) - Black 133) * Flush Louver - Top 134) * Flush Louver - Bottom

135. 940-349/P Glass (Flush) 138) 502-003 Flush Door Frame 139) 936-155 Glass Gasket (Tadpole)
140. 948-042 Spring Hinge

502-924 Finishing Trim - Black 141) * Trim Side Left 142) * Trim Side Right 143) * Trim Top

188. 948-216 Regency ® Logo Plate

*Not available as a replacement part.

PARTS LIST

Page 45 of the Regency P40 user manual — NOTES
Page 45 · click to enlarge
Page 45

NOTES

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

Page 46 of the Regency P40 user manual — NOTES
Page 46 · click to enlarge
Page 46

NOTES

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

___________________________________________________

Page 47 of the Regency P40 user manual — WARRANTY
Page 47 · click to enlarge
Page 47

WARRANTY

Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product. This warranty is not transferable.

The Warranty: Limited Lifetime The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for fi ve (5) years for parts and subsidized labour* and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for fi ve (5) years and parts only thereafter from date of purchase.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.

Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, ie. fi nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly components, and gas valves are covered for one year parts and subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.

FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.

Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.

Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of installation. Reported damage after this time will be subject to rejection.

It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect.

The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency® product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.

At all times FPI reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work.

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.

Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryer, etc.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

* Subsidy according to job scale as predetermined by FPI.

Page 48 of the Regency P40 user manual — Installer: Please complete the following information
Page 48 · click to enlarge
Page 48
Regency P40 — OPERATING INSTRUCTIONS diagram (page 48)
Fig. 101

FPI fi replaces are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door.

FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product.

See the inside back cover for details.

Register your Regency ® online at

http://www.regency-fi re.com

Installer: Please complete the following information

Dealer Name & Address: ______________________________________________

___________________________________________________________________

Installer: ___________________________________________________________

Phone #: ___________________________________________________________

Date Installed: ______________________________________________________

Serial No.: __________________________________________________________

Printed in Canada Regency® is a trademark of FPI Fireplace Products International Ltd.

© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.

Ask about the Regency P40

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Regency P40

Be the first to ask — other owners or our team will answer.