Installation Manual
the most watched worldwide

Copyright Copyright © 2003 Thomson Broadcast and Media Solutions, Inc. All rights reserved. Printed in the United States of America.
This document may not be copied in whole or in part, or otherwise reproduced except as specifically permitted under U.S. copyright law, without the prior written consent of Thomson Broadcast and Media Solutions, Inc., P.O. Box 59900, Nevada City, California 95959-7900
Trademarks Grass Valley, Profile, and Profile XP are either registered trademarks or trademarks of Thomson Broadcast and Media Solutions, Inc. in the United States and/or other countries. Other trademarks used in this document are either registered trademarks or trademarks of the manufacturers or vendors of the associated products. Thomson Broadcast and Media Solutions, Inc. products are covered by U.S. and foreign patents, issued and pending. Additional information regarding Thomson Broadcast and Media Solutions, Inc. trademarks and other proprietary rights may be found at www.thomsongrassvalley.com
Disclaimer Product options and specifications subject to change without notice. The information in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Thomson Broadcast and Media Solutions, Inc. Thomson Broadcast and Media Solutions, Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in this publication.
U.S. Government Restricted Rights Legend
Use, duplication, or disclosure by the United States Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7013 or in subparagraph c(1) and (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19, as applicable. Manufacturer is Thomson Broadcast and Media Solutions, Inc., P.O. Box 59900, Nevada City, California 95959-7900 U.S.A.
Revision Status


4 Profile XP Service Manual 16 April, 2003
Contents

To get technical assistance, check on the status of problems, or report new problems, contact Grass Valley Product Support via e-mail, the Web, or by phone or fax.
To access support information on the Web, visit the product support Web page on the Grass Valley Web site. You can download software or find solutions to problems by searching our Frequently Asked Questions (FAQ) database.
World Wide Web: http://www.thomsongrassvalley.com/support/ Technical Support E-mail Address: gvgtechsupport@thomson.net.
Use the following information to contact product support by phone during business hours. Afterhours phone support is available for warranty and contract customers.
Telephone (800) 547-8949 (Toll Free) (530) 478-4148 (Direct Dial Toll Call) Fax (530) 478-3181
UK Regional Service Location
Tel +44 1753 218 777 Fax +44 1753 218 757
Italy Tel +39 72 901 428 Fax +39 72 905 371
France Tel +33 145 297 300 Fax +33 145 297 302
Germany Tel +49 221 1791 234 Fax +49 221 1791 235
Australia Tel (612) 8877 6800 Fax (612) 8877 6825
India Tel (91) 11 373 0544 Fax (91) 11 373 0543
China Tel (86) 10 6235 1185 Fax (86)10 6235 1190
Japan Tel (813) 5484 6869 Fax (813) 5484 3775
Hong Kong Tel (852)-2531-3000 Fax (852)-2802-2996
Tel (65) 7328 729 Fax (65)7327 649
A local authorized support representative may be available in your country. To locate the support representative for your country, visit the product support Web page on the Grass Valley Web site.
You can connect with other Profile XP Media Platform users to ask questions or share advice, tips, and hints. Send e-mail to profile-users@thomson.net to join the community and benefit from the experience of others.
South East Asia

Product Support

You can use your 8-, 16-, or 8 to 64-port QLogic SANbox2 Fibre Channel switch to create fabrics for Grass Valley Media Area Networks (SCSI protocol) and Video Networks (Internet Protocol). This manual supplements the information provided by the QLogic SANbox2 Switch manuals that you received with your switch.
Please refer to the following QLogic manuals, included on the SANsurfer Tool Kit CD-ROM, when installing and configuring your QLogic SANbox2 Switch.

The following table describes how to use the documentation set that accompanies your QLogic SANbox2 Switch and other Grass Valley products.
For information on... See...
Installing the switch in a Profile Video Network
“Installing a Switch in a Profile Video Network” beginning on page 9 of this manual. SANbox2 Fibre Channel Switch Installer’s/User’s Manual SANbox2 Switch Management User’s Manual
Installing the switch in a Media Area Network
Media Area Network Instruction Manual SANbox2 Fibre Channel Switch Installer’s/User’s Manual SANbox2 Switch Management User’s Manual
Configuring the Fibre Channel switch for NetCentral monitoring
“Monitoring your switch with NetCentral” beginning on page 20 of this manual. SANbox2 Fibre Channel Switch Installer’s/User’s Manual SANbox2 Switch Management User’s Manual
Your QLogic SANbox2 Switch is sold, supported, and serviced by Grass Valley.
If you have any questions about your QLogic SANbox2 Switch, or if you need any help or service for the switch, please contact your local Grass Valley Support representative listed at the front of this manual

Installing a Switch in a Profile Video Network
Compared to a Fibre Channel hub, the Fibre Channel switch improves the performance of your Fibre Channel installation by:
The following figure shows the Profile Fibre Channel switch in a simple IP fabric environment.

The sections that follow describe the installation and use of the QLogic SANbox2 Switch in a Profile Video Network environment. Topics include:
You do not need to change the Fibre Channel firmware or drivers on Profile XP systems.

The following table lists the minimum Profile System Software version required for operation with a QLogic SANbox2 Switch. Earlier versions do not support this Fibre Channel switch.
Profile Model Minimum Profile System Software Version
PDR300 2.5.23
PDR400 3.2.8
PVS Series 5.2.X
Please refer to the Profile Release Notes for instructions on how to install your Profile System Software, as well as information on the new features that are included in the release.
PDR100 Not supported

PDR Series Fibre Channel firmware and driver
Early versions of the firmware for the PDR Series Fibre Channel board (1.4, 1.7.X) supported the Fibre Channel Arbitrated Loop, but would not function with a Fibre Channel switch. More recent versions of the firmware support operation with a switch and interoperation with other Fibre Channel board manufacturers, but have not been optimized for use in a loop.
To operate in a fabric environment, one which uses switches, you must use Fibre Channel board firmware that is compatible with the switch. You may use the same firmware in a loop environment, but you may encounter operational limitations that are not present with earlier versions of the firmware.
Generally, Fibre Channel firmware versions numbered 3.0 or higher, or identified as switch compatible, or interoperable, all support operation with the Fibre Channel switch.
Once you have installed Profile System Software version 2.5 or higher, you can load a switch-compatible version of firmware onto your Profile Fibre Channel board. You must load this firmware before connecting your Profile system to the QLogic SANbox2 Switch. You must also use this version of firmware if you wish to connect your Profile system to any other device that is equipped with Fibre Channel board from a supplier other than Grass Valley.
To load the switch-compatible firmware on your Profile Fibre Channel board:


If you wish to connect a Profile Fibre Channel Server to a QLogic SANbox2 Switch, you must load switch-compatible firmware on all the Fibre Channel boards installed in your server. You must also install the appropriate Fibre Channel drivers that can use all the features of the new firmware.
To load switch-compatible firmware on your Fibre Channel Server boards:
Once you’ve installed the required version of Profile System Software and loaded the appropriate firmware and drivers on all the devices you are connecting to the switch, you must configure each Profile Video File Server or Profile Fibre Channel Server for operation in a Fibre Channel fabric environment.
To configure your Profile Fibre Channel server or any device other than your Profile system, refer to the installation manual for that device for instructions.

Configuring Fibre Channel on your PDR Series
To configure your Profile system for use in a Fibre Channel environment, follow the instructions in the Profile User Manual. In addition to these instructions, you must also set Fibre Channel Switch Mode ON. You can do this in one of two ways:

Your QLogic SANbox2 Switch must be configured so that you can control and monitor it in your LAN environment. As you make these settings, you should also verify that all the other switch and port settings are appropriate for operation in a Grass Valley Fibre Channel fabric. The following instructions describe how to verify and assign these settings using a serial port connection. The same commands can also be used in a Telnet session over the Ethernet port.
You must be in administrator mode to make changes to your QLogic SANbox2 Switch settings. To enter this mode:
sb5_8port #> admin start
You must assign an Ethernet IP address, a subnet mask, and a default gateway to configure your QLogic SANbox2 Switch for operation in your Ethernet local area network.
sb5_8port (admin) #> set setup system
A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.
Eth0NetworkAddress (dot-notated IP Address) [192.168.5.216] Eth0NetworkMask (dot-notated IP Address) [255.255.255.0] Eth0GatewayAddress (dot-notated IP Address) [192.168.5.1] Eth0NetworkDiscovery (1=Static, 2=Bootp, 3=Dhcp, 4=Rarp) [Static]

Configuring your Fibre Channel switch
AdminTimeout (dec value 0-1440 minutes, 0=never) [30] TempMonitoringWarning (dec value 0-100 degrees Celsius) [65] TempMonitoringFailure (dec value 0-100 degrees Celsius) [70] TempFailurePortShutdown (True / False) [False] SecurityEnabled (True / False) [False] LocalLogEnabled (True / False) [True] RemoteLogEnabled (True / False) [False] RemoteLogHostAddress (dot-notated IP Address) [10.0.0.254]
Do you want to save and activate this system setup? (y/n): [n] y
You can use the show switch command to view switch information and confirm that the active firmware version is correct. The minimum qualified image is:
Contact your Grass Valley representative to determine the current required version.
To view the current version information:
sb5_8port (admin) #> show switch
Switch Information SymbolicName sb5_8port SwitchWWN 10:00:00:c0:dd:01:a6:47 SwitchType Sanbox2-8C PROMVersion V1.4.0.2-0 (Thu Mar 13 21:27:06 2003) CreditPool 0 DomainID 100 (0x64) FirstPortAddress 640000 FlashSize - MBytes 128 LogLevel Critical MaxPorts 8 NumberOfResets 17 ReasonForLastReset PowerUp SWImageVersion (1) - build date V1.4.0.39-0 (Tue Jan 21 08:11:16 2003) SWImageVersion (2) - build date V1.5.0.8-0 (Thu Mar 13 21:27:06 2003) ActiveConfiguration default ActiveSWImage 2 AdminState Online AdminModeActive True BeaconOnStatus False OperationalState Online PrincipalSwitchRole False

BoardTemp (1) - Degrees Celsius 22 BoardTemp (2) - Degrees Celsius 27 SwitchDiagnosticsStatus Passed SwitchTemperatureStatus Normal
You must ensure that all the Fibre Channel ports are correctly configured for operation with Grass Valley equipment. With these settings, you can use any port in a SCSI or IP fabric without any further configuration.
sb5_8port (admin) #> config edit
sb5_8port (admin-config) #> set config ports
A list of attributes with formatting and current values for the port specified at the command line or port #0 will follow. Each value that is changed will be set for ALL PORTS. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.
Configuring ALL ports (displaying values from port number: 0)
AdminState (1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online] LinkSpeed (1=1Gb/s, 2=2Gb/s, 3=Auto) [Auto] PortType (TL / GL / G / F / FL / Donor) [GL] TLPortMode (1=TLTargetMode, 2=TLInitiatorMode) [TLTargetMode] ISLSecurity (Any / Ours / None) [Any] ALFairness (True / False) [False] ARB_FF (True / False) [False] InteropCredit (decimal value, 0-255) [0] ExtCredit (dec value, increments of 11, non-loop only) [0] FANEnable (True / False) [True] LCFEnable (True / False) [False] MFSEnable (True / False) [True] MFS_TOV (decimal value, 10-20480 msec) [10] MSEnable (True / False) [True] NoClose (True / False) [False]

Configuring your Fibre Channel switch
IOStreamGuard (Enable / Disable) [Disabled] VIEnable (True / False) [False] CheckAlps (True / False) [False]
Finished configuring attributes. This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect. To discard this configuration use the config cancel command.
sb5_8port (admin-config) #> set config switch
sb5_8port (admin-config) #> set advanced on
A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.
AdminState (1=Online, 2=Offline, 3=Diagnostics) [Online] BroadcastEnabled (True / False) [True] InbandEnabled (True / False) [True] DefaultDomainID (decimal value, 1-239) [100] DomainIDLock (True / False) [True] SymbolicName (string, max=32 chars) [sb5_8port] R_T_TOV (decimal value, 1-1000 msec) [100] R_A_TOV (decimal value, 100-100000 msec) [2000] E_D_TOV (decimal value, 10-20000 msec) [1000] FS_TOV (decimal value, 100-100000 msec) [5000] DS_TOV (decimal value, 100-100000 msec) [5000] MFSMode (Hard / Soft) [Hard] PrincipalPriority (decimal value, 1-255) [254] ConfigDescription (string, max=64 chars) [SANbox2-8 FC Switch]
Finished configuring attributes. This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect.

To discard this configuration use the config cancel command.
sb5_8port (admin-config) #> config save
sb5_8port (admin-config) #> config activate
sb2_16port #> admin start
sb2_16port (admin) #> config edit
sb2_16port (admin-config) #> set config threshold
A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.
ThresholdMonitoringEnabled (True / False) [True] False
Finished configuring attributes. This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect. To discard this configuration use the config cancel command.
sb2_16port (admin-config) #> config save
sb2_16port (admin) #> config act
You must make various SNMP settings so that you can monitor your switch with NetCentral. Refer to “Monitoring your switch with NetCentral” on page 20 for SNMP configuration information.
If you are installing your QLogic SANbox2 Switch in a Grass Valley Media Area Network, refer to the Media Area Network Instruction Manual for specific configuration information.
q

Connecting devices to the switch
Follow the instructions in the SANbox2 Fibre Channel Switch Installer’s/User’s Manual to connect your Profile systems and other devices to the Fibre Channel switch. You should also take note of the following guidelines when setting up your fabric environment.
Use the appropriate cable types and GBICs (Gigabit Interface Converters) or SFPs (Small Form-factor Pluggable Transceiver) for the length of your Fibre Channel connections. In general, distances under 5 meters can be connected with copper cables. Distances from 5 to 500 meters require the use of fiber-optic cable.
Your choices in switch interconnections can greatly affect the cost, redundancy, and throughput of your Fibre Channel fabric. The number and connection strategy of inter-switch links defines your fabric’s capabilities.
Refer to the SANbox2 Fibre Channel Switch Installer’s/User’s Manual for detailed information on fabric topology.
The QLogic SANbox2 Switch has been qualified for operation with the following devices.
The QLogic SANbox2 Switch has not been qualified for operation with the following devices. Do not connect them to a QLogic SANbox2 Switch.

You can use NetCentral, a Grass Valley SNMP Manager, to monitor the state of your Fibre Channel switch. The information presented in NetCentral allows you to verify the normal operation of your switch and to detect any problems that may occur. If you set one or more appropriate SNMP trap destination addresses on your switch, you can also be alerted immediately when problems occur on the switch.

The following sections describe how to configure your switch for operation with NetCentral, and provide a brief guide on how to troubleshoot switch problems using NetCentral. Please refer to the NetCentral User Guide for information on how to install and use NetCentral.

NetCentral monitors the state of your Fibre Channel switch if your switch is connected to an Ethernet network accessible to the monitoring station. The SNMP agent is a standard software item on all Fibre Channel switches.
In addition to the agent, you must install the SANbox2 Device Provider on the NetCentral monitoring station. The device provider supplies many of the text messages that you read in the NetCentral window. The device provider is installed when you install the Profile XP Device Provider on the monitoring station. Install the device provider on the NetCentral Monitoring station using the appropriate installation instructions shown in the table.
Fibre Channel switch application To install the SANbox2 Device Provider on the NetCentral monitoring station, see...
Profile Video Network switch fabric Installing the NetCentral Agent and Device Provider for the Profile XP Media Platform
Media Area Network switch fabric Media Area Network Instruction Manual
Refer to “Configure Ethernet LAN settings” on page 14 for instructions on connecting your Fibre Channel Switch to an Ethernet network and assigning an Ethernet Internet Protocol (IP) address to your Fibre Channel switch.
SNMP includes a mechanism to report events as soon as they occur, rather than waiting until a device is polled to obtain its status. This type of notification is called a trap, and can be sent to one or several monitoring stations.
To configure the destination for trap notifications, follow these steps.
sb5_8port #> admin start
sb5_8port (admin) #> set setup snmp
A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.
SNMP configuration

Trap Severity Options unknown, emergency, alert, critical, error, warning, notify, info, debug, mark
Contact (string, max=32 chars) ["On-call engineer"] Location (string, max=32 chars) ["Rack 3-B"] Trap1Address (dot-notated IP Address) [192.168.217.5] Trap1Port (decimal value) [162] Trap1Severity (see allowed options above) [warning] Trap1Enabled (True / False) [True] Trap2Address (dot-notated IP Address) [192.168.216.48] Trap2Port (decimal value) [162] Trap2Severity (see allowed options above) [warning] Trap2Enabled (True / False) [True] Trap3Address (dot-notated IP Address) [0.0.0.0] Trap3Port (decimal value) [162] Trap3Severity (see allowed options above) [warning] Trap3Enabled (True / False) [False] Trap4Address (dot-notated IP Address) [0.0.0.0] Trap4Port (decimal value) [162] Trap4Severity (see allowed options above) [warning] Trap4Enabled (True / False) [False] Trap5Address (dot-notated IP Address) [0.0.0.0] Trap5Port (decimal value) [162] Trap5Severity (see allowed options above) [warning] Trap5Enabled (True / False) [False] ReadCommunity (string, max=32 chars) [public] WriteCommunity (string, max=32 chars) [private] TrapCommunity (string, max=32 chars) [public] AuthFailureTrap (True / False) [False] Do you want to save and activate this snmp setup? (y/n): [n] y
Your monitoring station should now receive all traps from your Fibre Channel switch. You can test this by creating a fault condition, such as disconnecting one of your Fibre Channel connections to the Fibre Channel switch. A message should appear in the NetCentral manager.

You can configure NetCentral to set the reporting name of each port on your QLogic SANbox2 Switch to something meaningful to you. When NetCentral reports the status of a port, or notifies you of a problem, you may find it convenient to see a name that you chose
To set port aliases:

Setting port aliases

You can use NetCentral to monitor the status of your QLogic SANbox2 Switch. NetCentral displays information about the switch’s power supplies, temperature, and fans. Click on the appropriate subsystem icon in the NetCentral window to view its status. Consult the NetCentral User Guide for more information on using NetCentral.
NetCentral also lets you monitor the status of each of the ports on your QLogic SANbox2 Switch. Click the Ports icon to view information such as the state, transmitter type, the number of frames in and out of each port.


You can also view error statistics for each of the ports. Choose View | Port Statistics to see a summary of the errors since the last switch reboot.

Monitoring Status

NetCentral reports status, warnings, and alarms using messages that are easy to understand. Suggested corrective actions are presented along with failure information. If you have any trouble interpreting any of the problems or suggested solutions, contact Grass Valley support.

You may wish to use the following procedures to recover from faulty configurations or other problems. Since these procedures stop all traffic on all Fibre Channel ports, be sure to take the switch out of service before performing any of these tasks.
Resetting factory defaults returns your QLogic SANbox2 Switch to its original configuration, although it does not reset the password. After resetting factory defaults, you must restore all the Grass Valley settings and site-specific network settings described earlier in this manual.
To reset the QLogic SANbox2 Switch to factory defaults:
sb5_8port #> admin start
sb5_8port #> reset factory
In some situations, you may be unable to use the reset factory command to restore factory defaults. For example, if you don’t remember the admin password, you cannot enter administrator mode to use the reset factory command.
The Reset/Force PROM button on the front panel allows you to bypass the normal switch control interfaces in unusual situations.
To enter the Force PROM mode do the following: