Instruction/ maintenance manual of the product 538 To 4224 Raypak
Go to page of 18
Raypak Commer cial Swimming P ool Heaters P art 1: Safety warning P art 2: Models 538 to 4224 P art 3: W arranty.
3 CONTENTS P art 1: For Y our Safety This Installation and Operating Instructions Manual is provided with the necessary information for the proper installation, operation and maintenance of your Raypak Heater . Please review and follow these procedures carefully .
P ART 1 - FOR Y OUR S AFETY 4 K eep this manual in a saf e and accessible place f or easy ref er ence in the futur e. This Installation and Operating Instr uctions Manual is pr ovided with the necessary infor mation f or the proper installation, operation and maintenance of y our Raypak Heat er .
P ART 1 - FOR Y OUR SAFETY 5 Ceramic Firetile Refractory is used in Raypak Heaters Possible risks of irreversible ef fects Harmful by inhalation May be irritating to the skin, eyes and respiratory system. WHEN HANDLING • Minimise airborne dust. • Wear an appr oved mask or respirator .
6 Raypak Commer cial Swimming P ool Heaters P art 2: Models 538 to 4224.
7 P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS Before commencing installation: 1. Read these instructions in full ! 2. Check that the heater you have been supplied is suitable for the type of installation and the gas available. The gas supply pressure must be between the minimum and maximum shown on the heater data plate.
P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS 8 Raypak recommends a minimum length of vertical flue of three (3) metres to ensure correct draft. OUTDOOR INST ALLA TIONS. An outdoor heater must not be installed inside any roofed structure or under eaves, roof overhangs, or pool decks.
9 P ART 2 - SECTION I - INST ALLA TION INSTRU CTIONS PUMP SELECTION The filtration pump must be sized to provide an adequate water flow for the filtration system and the heater .
C OMMISSIONING W ARNING: COMMISSIONING MUST ONL Y BE UNDERT AKEN BY A PROPERL Y AUTHORISED AND IN SOME CASES APPROPRIA TEL Y LICENSED PERSON WHO IS F AMILIAR WITH SAFE COMMISSIONING PROCEDURES. THE COMMISSIONING MA Y REQUIRE INSPECTION BY THE GAS SUPPL Y AUTHORITY , CHECK IF THIS IS APPLICABLE.
TO TURN OFF THE HEA TER 1. T urn the heater ON/OFF power isolation switch to the "OFF" position. EMERGENC Y SHUT -DOWN 1. T urn "OFF" the power supply to the heater 2. T urn "OFF" the gas isolation valve fitted close to the heater or the main gas supply .
P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS 1. FLAME FAILURE RESET: This is a combination rest button and indicator lamp. It indicates, when illuminated, that the ignition system has shutdown on its safety control.
13 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS RL1 MTR12 INSTRU CTIONS FOR USE OF LAE ELECTRONIC THERMOST A TS. Raypak uses the MTR12T1RES series thermostats which is programmed to operate in the heating mode.
14 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS MODELS WHICH ARE C ONNECTED T O A MICROZONE SYS TEM If the heater(s) are operated by a Microzone system, there will be a rotar y type control knob fitted which should be aligned to the desired temperature.
15 P ART2 - SECTION II - OPERA TING INSTRU CTIONS RECOMMENDED SERVICE PROCEDURES It is a Raypak requirement that all Raypak supplied equipment is serviced at least annually . In some installations, due to the appliance location and/or workload it may be necessary to perform a service ever y six months.
16 W ARNING!.
17 P ART 4 - W ARRANTY RA YP AK WARRANTY FOR COMMERCIAL SWIMMING POOL HEA TERS. Raypak Australia Pty Ltd* will: a) repair or , if necessary , replace any Raypak pool heater; or b) replace any componen.
18 NO TES.
RHEEM SERVICE 1 31 031 WWW .RHEEM.COM.A U Quality System Quality Endorsed Company Manufactured by Raypak A ustralia 7 Geddes St. Mulgrav e Vic 31 70 Ph.
An important point after buying a device Raypak 538 To 4224 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Raypak 538 To 4224 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Raypak 538 To 4224 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Raypak 538 To 4224 you will learn all the available features of the product, as well as information on its operation. The information that you get Raypak 538 To 4224 will certainly help you make a decision on the purchase.
If you already are a holder of Raypak 538 To 4224, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Raypak 538 To 4224.
However, one of the most important roles played by the user manual is to help in solving problems with Raypak 538 To 4224. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Raypak 538 To 4224 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center