OPERA TING AND INST ALLA TION INSTRUCTIONS Models 185, 265, 335, 405 Swimming Pool and S pa Heaters 181/182, 260/261, 330/331, 400/401 W ater Heaters and Boilers D-2 POWER VENT (FOR ELECTRONIC IGNITION MODELS ONLY) CATALOG NO.
POWER VENT ASSEMBL Y INST ALLA TION, ST ART -UP AND OPERA TION 1. RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment.
3 3. INSTALLATION REQUIREMENTS The equipment must be installed in accordance with local codes, or in the absence of local codes with the latest edition of the National Fuel Gas Code, ANSI Z223.
4 WIRING A POWERVENT ASSEMBL Y TO AN APPLIANCE WITH IID IGNITION. W ARNING : Disconnect all electrical power to the unit before servicing to avoid potential shock injury or damage to the unit. T o change voltages, follow wiring diagram for correct voltage connections.
VENTING The vent pipe must be the same size or larger than what is indicated. The D-2 Power V ent are capable of 360-degree discharge rotation and operate with a positive vent st atic pressure and with a vent gas temperature less than 400°F . The tot al length of horizontal run shall not exceed an equivalent of 40 feet including termination cap.
6 The Raypak Power Vent operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent and as such it is listed as a CATEGORY III appliance. Exception: When a Power Vent is connected to a vertical vent of sufficient height to generate a negative draft in the system.
7 185-405 POOL HEA TER (A TMOSPHERIC).
8 185-405 POOL HEA TER ( Low NOx).
9 182-260 WH1 (A TMOSPHERIC).
181-261 WH1 (Low NOx) 10.
SEQUENCE OF OPERA TION On call for heat, the D-2 Power Vent fan (and appliance pump) start. When the flow switch circuits close, the ignition system consisting of an electronic spark module, pilot gas system and flame sensor, are energized.
START UP PROCEDURES The water system, the gas system and the electrical system for the heater should be completed and checked as per the heater installation manual and associated documents. 1. Turn on power to the heater with the manual main gas valve and pilot gas valve off.
ILLUSTRA TED P ARTS LIST 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15.
Raypak, Inc. , 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725 Raypak Canada LTD , 2805 Slough Street, Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 FAX (905) 677-8036 Raypak Australia Pty. Ltd , 7 Geddes St., Mulgrave, Victoria, Australia 3170 (6139) 560 4944 FAX (6139) 560 4974 Litho in U.
An important point after buying a device Raypak 405 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Raypak 405 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Raypak 405 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Raypak 405 you will learn all the available features of the product, as well as information on its operation. The information that you get Raypak 405 will certainly help you make a decision on the purchase.
If you already are a holder of Raypak 405, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Raypak 405.
However, one of the most important roles played by the user manual is to help in solving problems with Raypak 405. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Raypak 405 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center