Instruction/ maintenance manual of the product SeaEra Toilets Raritan Engineering
Go to page of 16
Pressurized Freshwater Model Sea W ater Model (Remote Pump) Sea W ater Model (Integral Pump) The SeaEra toilet is a powerful centrifugal macerating toilet that thoroughly breaks down waste.
Press push-button switch and hold until all waste is cleared from the toilet bowl. • No special toilet paper is required. • W ater should appear in the bowl within ten seconds. If not, see troubleshooting section. • Hard objects or stringy substances (paper towels, feminine hygiene products, filter cigarettes, etc.
Clean Gaske t and Gasket Contact Surf aces Thoroughly Unscre w Tighten Cleaning Instructions IMPOR T ANT : Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These may cause damage to the toilet. Using C.
WINTERIZING IMPOR T ANT • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations.
Integral and Remote Intake Pump Models Parts Require d 3/4" (19mm) I.D. intake hose approximately 3 feet (1m) long. 1" (25mm) or 1 1/2" (38mm) I.D. discharge hose approximately 3 feet (1m) long. T wo buckets Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1.
SPECIFICA TIONS Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size 6 5/8" (16.8cm) 19 3/4" (52.1cm) Household 17 1/2" (44.5cm) Marine 14 3/8" (36.5cm) Household 13" (33cm) Marine 11 1/8" (28.3cm) 14 7/8" (37.
7 Mounting T oilet Mounting surface must be flat and solid. 1. Install seat on toilet. 2. Remove motor cover . 3. Place toilet where it will be located. Make sure ther e is r oom to route hoses. Make sure seat will open pr operly . 4. Mark location of toilet base mounting holes on mounting surface.
8 90° Rotation of T oilet Bowl T oilet bowl can be rotated 90° on the base, for installing in confined locations. NOTE: SeaEra Models with Integral Pump: Replace existing hose from the intake pump to the toilet bowl with a longer hose. 1 . Determine which direction bowl is to be mounted.
INST ALLA TION Mounting W ater Solenoid V alve (Pressurized Fr eshwater Models Only) 1. Locate valve on a solid flat surface in an area that is dry and well ventilated. 2. Mark and drill holes for water solenoid mounting bracket. NOTE: Hole size will depend on type of bolts/screws used (1/4" [6mm] size bolt/screws are recommended).
10 INST ALLA TION Discharge Lines 1 . Connect quality sanitation hose 1" (25mm) or 1 1/2" (38mm) I.D. to discharge fitting on toilet. 2 . Run hose to appropriate device (i.
11 From Seacock T o Intake Pump INST ALLA TION Intake Lines Pressurized Fr eshwater Models Install a shut off valve in intake line before water solenoid valve.
WIRING W ARNING: Hazard of Shock and Fir e • Always use proper wir e, wire connectors and fuse/circuit br eaker . See Specification Chart. • Secure wir e properly . • Do not connect appliances to toilet circuit. • Make sure power is off before pr oceeding.
TR OUBLESHOO TING W ARNING: HAZARD OF ELECTRIC SHOCK - Bef ore beginning any work on the SeaEr a, be sure that all power to the unit has been turned of f. W ARNING: HAZARD OF FLOODING - Make sur e seacocks are in the CLOSED or OFF position befor e working on toilet.
EXPLODED P AR TS P ar t No. Description 1108A Macerator Nut 1222A W 90° Discharge F itting 1226 Mounting Scre w (4) 1226B 1/4-20 Hex Nut (4) 1234 Bo wl Gasket 1236A W Bo wl Spud Assembly 1236E Bo wl .
15 EXPLODED P AR TS SeaEra Exploded Parts V iew 1244 or 1237 1236A W 1236E 1234 VCAP 1226B RNI CH38 161105 C254 161130 1222A W 161125 F164 161107 1108A M23A 161123 161120 161115 31-102 161110 1610* HW.
L318 0103kgs Specifications Subject to Change Without Notice Printed in U.S.A. 530 Orange Street, P.O. Box 1157, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.
An important point after buying a device Raritan Engineering SeaEra Toilets (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Raritan Engineering SeaEra Toilets yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Raritan Engineering SeaEra Toilets - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Raritan Engineering SeaEra Toilets you will learn all the available features of the product, as well as information on its operation. The information that you get Raritan Engineering SeaEra Toilets will certainly help you make a decision on the purchase.
If you already are a holder of Raritan Engineering SeaEra Toilets, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Raritan Engineering SeaEra Toilets.
However, one of the most important roles played by the user manual is to help in solving problems with Raritan Engineering SeaEra Toilets. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Raritan Engineering SeaEra Toilets along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center