Instruction/ maintenance manual of the product QZ3111 Quartz
Go to page of 16
Quartz Thermo installation guide page 1 Quartz ® Thermo C oncealed show er v alv e with adjust able head.
Quartz Thermo installation guide page 2 Show er s ystems Quartz Thermo built-in shower v alv e with adjustable head QZ3111 C omponents.
Quartz Thermo installation guide page 3 Import ant inf ormation Intr oduction The Quartz Thermo is designed f or both built-in and concealed panel mount installation and is supplied complet e with adjustable height head.
Quartz Thermo installation guide page 4 Import ant inf ormation P ump installation UNDER NO CIRCUMST ANCES MUST A PUMP BE FITTED DIRECTL Y T O THE W A TER MAIN. A pump must only be used to boost the pressure f rom t ank-f ed supplies. A typical la yout is shown on the rev erse of this guide.
Quartz Thermo installation guide page 5 Step-b y-step instructions In addition to the guide below it is essential that the written instructions overleaf ar e read and understood and that you hav e all the necessary components (shown overleaf) bef ore commencing installation.
Quartz Thermo installation guide page 6 Set the temper ature control lev er to full cold (9 o’clock) prior to removing the f our screws securing the lever to the v alve. C arefully r emove the temper ature lev er to reveal the lilac temper ature preset ov erride ring and the white temper ature preset location ring.
Quartz Thermo installation guide page 7 The installation may now be check ed f or leaks. T emporarily cap off the outlet supply pipe. Push the on/off lev er assembly onto the f ront of the valve f ully home and turn the knob fully clockwise to ensure the valv e is fully turned off.
Quartz Thermo installation guide page 8 R efit the lilac temper ature preset ov erride ring and the white temper ature preset location ring if remov ed prior to installation, taking car e to fit the override ring in the correct orientation as outlined in st ep 5.
Quartz Thermo installation guide page 9 Ensuring the fixing lugs and locating pins are correctly aligned, caref ully place the valve end c ap onto the on/off lever and click into position. 23 Adjustable height head inst allation Prepar e pipe work f rom the shower valv e to the required position f or the hose outlet using a ø15mm copper pipe.
Quartz Thermo installation guide page 10 Drill and plug two holes 642mm-655mm vertically apart using a spirit le vel if necessary. Fit the rail end clip into position and loosely fit the lower br ack et into position.
Quartz Thermo installation guide page 11 Connect the hose to the wall outlet assembly after passing it through the gel hook/hose restr aint (if required) and run the shower f or 15 seconds without the handset attached to clear any internal debris, which may be present.
Quartz Thermo installation guide page 12 After inst allation... Commissioning The Quartz Thermo valve is pr e-set to a saf e maximum show er temper ature. During use, the action of the stop button may be overridden b y depressing it as the temper ature control is r otated.
Quartz Thermo installation guide page 13 User guide Shower oper ation T urn the on/off control fully anti-clockwise into the open position to turn the shower on.
Quartz Thermo installation guide page 14 T roubleshooting guide W ater output is either all hot or all cold, or cold only Symptom P ossible cause Action Re versed inlet supplies Check that the supplie.
Quartz Thermo installation guide page 15 T ypical inst allations Supply Cent ral heating boiler Supply V ent and draw-off pipe to hot water Underside of cistern Highest point must be below underside o.
Aqualisa Pr oducts Limited The Flyer’s W ay W esterham K ent TN16 1DE Sales enquiries: 01959 560010 R epublic of Ireland 01-864-3363 Customer helpline: 01959 560010 R epublic of Ireland 01-844-3212 Brochure Hotline: 0800 652 3669 W ebsite: www.aqualisa.
An important point after buying a device Quartz QZ3111 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Quartz QZ3111 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Quartz QZ3111 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Quartz QZ3111 you will learn all the available features of the product, as well as information on its operation. The information that you get Quartz QZ3111 will certainly help you make a decision on the purchase.
If you already are a holder of Quartz QZ3111, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Quartz QZ3111.
However, one of the most important roles played by the user manual is to help in solving problems with Quartz QZ3111. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Quartz QZ3111 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center