EN
Proxim logo
Official user manual

Proxim 7920

76 pages·584 KB·Network Card·PDF·ENDEFRITNLJA
Proxim 7920
Table of Contents 6 sections Contents · 1. Introduction · The RangeLAN2 Family · System Requirements · … ShowHide
Page 1 of the Proxim 7920 user manual
Page 1 · click to enlarge
Page 1
Proxim 7920 diagram (page 1)
Fig. 1
Page 2 of the Proxim 7920 user manual — 1. Introduction
Page 2 · click to enlarge
Page 2

Copyright © 1998 Proxim, Inc., Mountain View, CA. All rights reserved. This manual and the software described in it are copyrighted with all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language in any form by any means without the written permission of Proxim, Incorporated.

Trademarks RangeLAN, the RangeLAN logo, RangeLAN2, and Proxim are trademarks of Proxim, Inc. All other trademarks are the property of their respective owners.

Limited Warranty, Disclaimer, Limitation Of Liability For a period of one (1) year from the date of purchase by the retail customer, Proxim warrants the RangeLAN2 Ethernet Adapter against defects in materials and workmanship. Proxim will not honor this warranty if there has been any attempt to tamper with or remove the Ethernet Adapter's external foil label.

This warranty does not cover and Proxim will not be liable for any damage or failure caused by misuse, abuse, acts of God, accidents, or other causes beyond Proxim's control, or claim by other than the original purchaser.

If, after inspection, Proxim determines there is a defect, Proxim will repair or replace the Adapter at no cost to you. To return defective merchandise to Proxim, please call Proxim Technical Support at: 650-526-3640 to obtain a Return Merchandise Authorization (RMA) Number.

In no event shall Proxim, Incorporated be responsible or liable for any damages arising:

K From the use of the product;

K From the loss of use, revenue, or profit of the product; or

K As a result of any event, circumstance, action, or abuse beyond the control of Proxim, Incorporated.;

Whether such damages be direct, indirect, consequential, special or otherwise and whether such damages are incurred by the person to whom this warranty extends or a third party.

Part # 7360.0099 Rev B

Page 3 of the Proxim 7920 user manual — FCC WARNING
Page 3 · click to enlarge
Page 3

If you have a problem with your RangeLAN2 product, please call Proxim Technical Support at 650-526-3640. Proxim Technical Support will assist with resolving any technical difficulties you may have with your Proxim product.

If your product is found to be defective, you may return the product to Proxim after obtaining an RMA (Return Materials Authorization) number from Proxim Technical Support. The product must be returned in its original packaging. The RMA number should be clearly marked on the outside of the box. Proxim cannot be held responsible for any product returned without an RMA number, and no product will be accepted without an RMA number.

FCC WARNING

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

K Reorient or relocate the receiving antenna. K Increase the separation between the equipment and the receiver. K Connect the equipment into an outlet on a circuit different from that which the receiver is connected. K Consult the dealer or an experienced radio/TV technician for help.

Warranty Return Policy

Page 6 of the Proxim 7920 user manual — 2. Quick Installation
Page 6 · click to enlarge
Page 6
Page 6 of the Proxim 7920 user manual — 2. Quick Installation
Page 7 of the Proxim 7920 user manual — 1. Introduction
Page 7 · click to enlarge
Page 7

1. Introduction

Congratulations on your purchase of the RangeLAN2 792x Ethernet Adapter, a member of the RangeLAN2 family. As with all members of the RangeLAN2 family, the Ethernet Adapter is a long range, high performance LAN product that allows Ethernet- ready devices to communicate wirelessly with networked com- puters.

The RangeLAN2 792x Ethernet Adapter was designed to be a “plug and play” product. External rotary switches allow you to configure your Ethernet Adapter manually. In many cases, you will not even need to run any software to configure it. However, if you need to change the software parameters, you will find the configuration tool easy to use. In no time, you will have a wireless connection to your network’s application software, printing, e-mail, and other network services!

This wireless adapter allows for easy expandability of your wireless network, increasing range and facilitating mobility applications. It operates at the Data Link level (layer 2) of the OSI model providing an Ethernet-ready device with protocol- independent access into an existing RangeLAN2 network.

Proxim is the leading supplier of spread spectrum radio network- ing technology for local area environments. Proxim’s un- matched spread spectrum networking expertise, combined with the company’s extensive experience serving the communication needs of the mobile computing user, have kept Proxim at the forefront of the emerging wireless market.

Page 8 of the Proxim 7920 user manual — K RangeLAN2 791x Serial Adapter is a wireless serial
Page 8 · click to enlarge
Page 8

The RangeLAN2 Family

RangeLAN2 792x Ethernet Adapter is part of a family of high- performance products that provides a complete wireless net- working solution.

K RangeLAN2 7100 is a wireless LAN adapter that fits

into a standard PC/AT ISA bus slot.

K RangeLAN2 7400 is a wireless LAN adapter which fits

into a PCMCIA Type II slot on a portable notebook, laptop, or pen-based computer.

K RangeLAN2 7510/752x Access Points allow

RangeLAN2 products to seamlessly connect to a wired Ethernet network.

K RangeLAN2 753x Access Point allows RangeLAN2

products to seamlessly connect to a wired Token Ring network.

K RangeLAN2 754x Extension Point extends the cover-

age area of an existing RangeLAN2 network.

K RangeLAN2 791x Serial Adapter is a wireless serial

device which acts as a replacement for an RS-232 cable.

Page 9 of the Proxim 7920 user manual — K One (1) RangeLAN2 792x Ethernet Adapter User’s
Page 9 · click to enlarge
Page 9

System Requirements

To begin using your RangeLAN2 792x Ethernet Adapter, you need the following minimum system requirements:

K An Ethernet-ready device such as a computer or

Ethernet hub.

K At least one other RangeLAN2 product installed on the

network.

The Product Package

Each RangeLAN2 792x Ethernet Adapter comes with:

K One (1) RangeLAN2 Ethernet Adapter.

K One (1) 1 dBi omnidirectional antenna.

K One (1) 12 Volt, 1 Amp power adapter.

K One (1) RS-232 serial cable.

K One (1) switch setting tool.

K Two (2) plastic plugs to cover the Domain and Station

Type rotary switches.

K One (1) RangeLAN2 792x Ethernet Adapter User’s

Guide.

If any of these items are missing or damaged, please contact your reseller or Proxim Technical Support.

Page 10 of the Proxim 7920 user manual — Figure 1 RangeLAN2 792x Ethernet Adapter Components
Page 10 · click to enlarge
Page 10
Proxim 7920 — 2. Quick Installation diagram (page 10)
Fig. 2 · 2. Quick Installation

Figure 1 RangeLAN2 792x Ethernet Adapter Components

Page 11 of the Proxim 7920 user manual — Follow the steps below to install the RangeLAN2 792x Ethernet Adapter:
Page 11 · click to enlarge
Page 11

2. Quick Installation

You may follow the quick installation and configuration steps, listed below, if all of the following conditions are true:

K You will use all of the software default values.

K You intend to use the Ethernet Adapter to connect an

Ethernet-ready device to an existing RangeLAN2 network.

K The existing network uses a Domain number between 0

and 9.

K You do not intend to set Security IDs on your network.

K You do not intend to configure the Ethernet Adapter

with an IP address.

Follow the steps below to install the RangeLAN2 792x Ethernet Adapter:

1. Firmly screw the antenna onto its connector in a clockwise rotation. The antenna connector is located on the side of the unit as shown in Figure 2.
Page 12 of the Proxim 7920 user manual — Figure 2 Attachment of the RangeLAN2 Ethernet Adapter Antenna
Page 12 · click to enlarge
Page 12
Proxim 7920 — 2. Quick Installation diagram (page 12)
Fig. 3 · 2. Quick Installation

Figure 2 Attachment of the RangeLAN2 Ethernet Adapter Antenna

2. Each RangeLAN2 792x Ethernet Adapter is preconfigured to use Domain 0. If the existing wireless network is not using Domain 0, use the Domain rotary switch on the underside of the RangeLAN2 Ethernet Adapter to set the Domain number to a value between 0 and 9. If the existing network is using a Domain number between 10 and 15, you must set the Domain number within the software configuration menu. See Chapter 5 for information on how to access the Ethernet Adapter’s configuration menu.

Page 13 of the Proxim 7920 user manual — 2. Quick Installation
Page 13 · click to enlarge
Page 13
3. Plug the power supply into the RangeLAN2 Ethernet Adapter DC power jack, located on the rear panel, and plug the power supply into an AC outlet. Upon completing this step, the LED indicator on the top panel of the unit will glow yellow and then turn green, indicating that the unit is ready for operation.
4. Connect one end of a standard 10BASE-T cable to an Ethernet-ready device and the other end to the Ethernet Adapter. If you are connecting the Ethernet Adapter to a cabling hub, you must use a 10BASE-T cross-over cable. See Chapter 4 for information on the pinout specification of a 10BASE-T cross-over cable.

When the cable is correctly connected to both units, the Link LED to the right of the Ethernet Adapter’s 10BASE-T connector will glow steady green.

5. Confirm that the yellowSync LED, located between the serial port and the DC power jack, is on. This light indicates that the Ethernet Adapter has synchronized to a RangeLAN2 product acting as a Master. If this LED light is not on, recheck the location and software settings of your Master unit.
6. Confirm that the software setting, “Filter Fixed Nodes,” is set to “Not Filtering” on all RangeLAN2 Access Point on the network to which the Ethernet Adapter may roam. This step is not necessary if you are using a RangeLAN2 Access Point model 7510, 7520, or 7521 with revision 1.4 or greater of the Access Point flash code image installed.
Page 14 of the Proxim 7920 user manual — 2. Quick Installation
Page 14 · click to enlarge
Page 14

Note: The RangeLAN2 Access Point is shipped with Filter Fixed Nodes set to “Filtering” by default. Unless you are using an Ethernet Access Point (model 7510, 7520, or 7521) with revision 1.4 or greater of the Access Point flash code image installed, this param- eter must be set to “Not Filtering” in order for the Ethernet-ready device attached to the Ethernet Adapter to communicate with the wired network. For more information on this requirement, please refer to Chap- ter 11.

7. Your RangeLAN2 Ethernet Adapter is now ready for operation, and the Ethernet-ready device should be able to communicate with the wired and wireless network through the Ethernet Adapter.

If you cannot communicate between the Ethernet-ready device and the RangeLAN2 network, compare your network settings with the RangeLAN2 Ethernet Adapter’s default values. You may need to adjust the Ethernet Adapter’s software parameters. Please consult Chapter 5 for information on how to customize the configuration of the RangeLAN2 Ethernet Adapter and Chapter 11 for troubleshooting suggestions.

Page 15 of the Proxim 7920 user manual — Ad Hoc
Page 15 · click to enlarge
Page 15

3. Wireless Topologies

RangeLAN2 products look and operate similar to Ethernet products. The only difference is that a radio replaces the wire between various nodes. This means that all of your existing applications that operate over Ethernet will work with RangeLAN2 without any special wireless networking software. Wireless products are typically used in several network topolo- gies described in this chapter.

Ad Hoc

With wireless LANs, one or more computers easily establish an ad hoc network when the units are in range of each other. Each computer can dynamically connect and reconnect to the others with no additional configuration, using off-the-shelf peer-to-peer network operating systems. With this capability, many compa- nies are developing applications optimized for ad hoc networks.

With the addition of the Ethernet Adapter to the RangeLAN2 family, you may now connect resources to your wireless network that previously did not support a Proxim device driver such as printers, UNIX-based systems, and Macintosh computers.

Proxim 7920 — Ad Hoc diagram (page 15)
Fig. 4 · Ad Hoc

Ad Hoc

Page 16 of the Proxim 7920 user manual — Figure 4 Single Ethernet AP
Page 16 · click to enlarge
Page 16

Infrastructure

Many companies have an existing Ethernet or Token Ring LAN infrastructure and want to be able to extend that capability to wireless nodes. This is accomplished by attaching an Access Point to the wired LAN. This allows the wireless clients to access the network resources.

Proxim 7920 — Infrastructure diagram (page 16)
Fig. 5 · Infrastructure

Figure 4 Single Ethernet AP

For larger environments, RangeLAN2 products support the ability to roam from one wireless cell to another while maintain- ing the same network connection. The Access Points establish coverage areas or cells similar in concept to those of a cellular phone network. The mobile clients will connect with any Ac- cess Point that is within range.

Page 17 of the Proxim 7920 user manual — Figure 5 Roaming on Ethernet LAN - Light Overlap
Page 17 · click to enlarge
Page 17
Proxim 7920 — 2. Quick Installation diagram (page 17)
Fig. 6 · 2. Quick Installation

Figure 5 Roaming on Ethernet LAN - Light Overlap

With RangeLAN2’s multi-channel architecture, Access Points can be placed within the same cell area to increase the aggregate throughput supported by the network. In addition, the overlap- ping cells offer redundancy of coverage required in networks where downtime is not tolerable.

Page 18 of the Proxim 7920 user manual — Figure 6 Roaming on Ethernet LANHeavy Overlap
Page 18 · click to enlarge
Page 18
Proxim 7920 — 2. Quick Installation diagram (page 18)
Fig. 7 · 2. Quick Installation

Figure 6 Roaming on Ethernet LANHeavy Overlap

Each RangeLAN2 Access Point within a roaming network must be configured as a Master on a unique Channel/Subchannel pair, but all Access Points must have the same Domain number and Security ID. In addition, mobile clients, such as the Ethernet

Page 19 of the Proxim 7920 user manual — 2. Quick Installation
Page 19 · click to enlarge
Page 19

Adapters or laptops with 7400 PC cards, are set to the same Domain and Security ID as the Access Points. As the RangeLAN2 mobile clients seamlessly switch from cell to cell, the network connectivity is preserved.

The user can move freely between the RangeLAN2 Access Points in the network. When the roaming unit leaves the trans- mission range of one RangeLAN2 Access Point, the software automatically polls the other RangeLAN2 Access Point in the same Domain to continue the network connection.

The RangeLAN2 Ethernet Adapter allows you to add printers, computers in locations which are difficult to wire, and other Ethernet-ready devices to the wired LAN by synchronizing to a RangeLAN2 Access Point connected to the wired backbone.

Page 20 of the Proxim 7920 user manual — Figure 7 Workgroup Concentrator
Page 20 · click to enlarge
Page 20

Workgroup Concentrator

In small networks, the RangeLAN2 Ethernet Adapter may be used as a workgroup concentrator to connect up to 8 Ethernet devices to a RangeLAN2 wireless network.

However, the Ethernet Adapter can NOT support more than 8 devices on its Ethernet port, as shown in Figure 7. The Ethernet Adapter filters at a rate less than full Ethernet speed. This will not pose a problem for a small network with a minimal amount of Ethernet traffic; however, if your network has a significant amount of Ethernet traffic or more than 8 Ethernet devices, use a RangeLAN2 Access Point in place of the Ethernet Adapter.

Proxim 7920 — Workgroup Concentrator diagram (page 20)
Fig. 8 · Workgroup Concentrator

Figure 7 Workgroup Concentrator

Page 21 of the Proxim 7920 user manual — 2. Quick Installation
Page 21 · click to enlarge
Page 21

Since an Ethernet Adapter’s 10BaseT connector is wired to operate like a standard Ethernet cabling hub, you must use a 10BaseT cross-over cable to connect an Ethernet Adapter to a cabling hub. See Chapter 2 for information on the pinout speci- fication for a 10BaseT cross-over cable.

If your networking needs require greater wireless coverage than what is provided by a single Ethernet Adapter, use multiple RangeLAN2 Access Points in place of the Ethernet Adapter.

Page 22 of the Proxim 7920 user manual — Figure 8 Repeating
Page 22 · click to enlarge
Page 22

Repeating

You have the option to enable or disable repeating. When repeating is enabled, the RangeLAN2 Ethernet Adapter, set as a Master, will repeat any signal coming from one Station and destined for another Station, when the two Stations are both within range of the Master, but not within range of one another.

The advantage of repeating is the ability to double the effective range of the RangeLAN2 network. However, be aware that by enabling the repeating feature, the network throughput will drop by as much as one-half when repeating occurs. When repeating is disabled, the RangeLAN2 Ethernet Adapter will not repeat the signals of Stations synchronized to it. By default, repeating is disabled.

Proxim 7920 — Repeating diagram (page 22)
Fig. 9 · Repeating

Figure 8 Repeating

Page 23 of the Proxim 7920 user manual — K The Domain Switch allows the user to set the Domain
Page 23 · click to enlarge
Page 23

4. Understanding the Hardware

Rotary Switches

The RangeLAN2 Ethernet Adapter is designed for easy config- uration by setting two rotary switches located on the bottom of the unit. The rotary switches are shown in Figure 9 below. Use the switch setting tool, enclosed in the product package, to change the position of the rotary switches.

K The Station/Master Switch allows the user to externally

set the unit’s Station Type to either a Master or a Sta- tion within a wireless network. The Ethernet Adapter is pre-configured so that the switch is set as a Station.

K The Domain Switch allows the user to set the Domain

number to a value between 0 and 9. The Ethernet Adapter is preconfigured to operate using Domain 0. If you want to set the Domain to a number between 10 and 15, you must use the software configuration menu. See Chapter 5 for information on how to access the Ethernet Adapter’s software configuration menu.

Page 24 of the Proxim 7920 user manual — K The Status LED on the right side (with the unit orien-
Page 24 · click to enlarge
Page 24
Proxim 7920 — 2. Quick Installation diagram (page 24)
Fig. 10 · 2. Quick Installation

Domain Switch Station/Master Switch

Figure 9 Rotary Switches

LED Indicators

There are three LEDs on the top panel of the RangeLAN2 792x Ethernet Adapter:

K The Status LED on the right side (with the unit orien-

tated so that you can read the Proxim logo), changes colors from yellow (initializing) to green (operational). This LED will blink red in a repeating pattern if a problem occurs with the unit during operation. See Chapter 11 for a further discussion of these patterns.

Page 25 of the Proxim 7920 user manual — Status LED Radio LED Ethernet LED
Page 25 · click to enlarge
Page 25

K The Radio LED in the center blinks yellow when the

Ethernet Adapter is transmitting data packets over its radio.

K The Ethernet LED on the left side blinks green when the

Ethernet Adapter is transmitting data over the 10BASE- T Ethernet port.

Proxim 7920 — K The Ethernet LED on the left side blinks green when the diagram (page 25)
Fig. 11 · K The Ethernet LED on the left side blinks green whe…

Status LED Radio LED Ethernet LED

Figure 10 Top Panel LEDs

Page 26 of the Proxim 7920 user manual — K The yellow “Override” LED, located between the serial
Page 26 · click to enlarge
Page 26

There are also four LEDs on the back panel of the RangeLAN2 792x Ethernet Adapter:

K The green “Master” LED, located between the DC

power jack and the serial interface, is on steady when the unit is set as a Master.

K The yellow “Sync” LED, located between the DC

power jack and the serial interface, is on steady when the unit is set as a Station and is synchronized to a Master.

K The green “Link” LED, located between the serial

interface and the 10BASE-T connector, is on steady to indicate an Ethernet link between the Ethernet Adapter and the Ethernet-ready device. This LED blinks when the unit sends packets through its Ethernet port. Note that this LED will blink on occasion even if a proper 10BASE-T cable is not connected.

K The yellow “Override” LED, located between the serial

interface and the 10BASE-T connector, is on steady when the Station Type and Domain parameters config- ured by the software interface override those set by the external rotary switches.

Page 27 of the Proxim 7920 user manual — Figure 11 Back Panel LEDs
Page 27 · click to enlarge
Page 27

Link LED

Master LED

Sync LED

Override LED

Proxim 7920 — Link LED diagram (page 27)
Fig. 12 · Link LED

Figure 11 Back Panel LEDs

Page 28 of the Proxim 7920 user manual — Figure 12 Cross-over Cable Pinout
Page 28 · click to enlarge
Page 28

10BASE-T Connector Specification

The 10BASE-T connector located on the back panel of the Ethernet Adapter (see Figure 11, above) is wired like a cabling hub and connects to any Ethernet Network Interface Card using a standard 10BaseT cable. Standard 10BASE-T specifications apply to the 10BASE-T interface of the Ethernet Adapter. No segment can exceed 100 meters.

If you intend to plug the Ethernet Adapter directly into a cabling hub, you must use a 10BASE-T cross-over cable. A cross-over cable differs from a standard 10BASE-T cable in that pins 1 and 3 and pins 2 and 6 are crossed. Figure 12 below demonstrates the pinout for a 10BASE-T cross-over cable.

Figure 12 Cross-over Cable Pinout

Page 29 of the Proxim 7920 user manual — Serial Port Specification
Page 29 · click to enlarge
Page 29

Serial Port Specification

Figure 13 and the table below provide the specification of the nine (9) pin serial port located on the RangeLAN2 Ethernet Adapter.

The Ethernet Adapter is wired as a standard DCE (Data Commu- nication Equipment) device.

re b m u N niP n oitc n u F niP laire S

1 nip )tc ete D reirra C ( D C

2 nip )ata D ti m s n arT( D X T

3 nip )ata D e vie c e R ( D X R

4 nip )y d a e R la ni m re T ata D ( R T D

5 nip )d n u or G ( G S

6 nip )y d a e R te S ata D ( R S D

7 nip )d n e S otts e u q e R ( S T R

8 nip )d n e S otra elC ( S T C

9 nip )rota cid nI g niR (IR

Page 30 of the Proxim 7920 user manual — Figure 13 Serial Port Specification
Page 30 · click to enlarge
Page 30
Proxim 7920 — 2. Quick Installation diagram (page 30)
Fig. 13 · 2. Quick Installation

Figure 13 Serial Port Specification

Page 31 of the Proxim 7920 user manual — Mounting Options
Page 31 · click to enlarge
Page 31

Antenna Options

The Ethernet Adapter is shipped with a standard directly-con- nected antenna. To install the antenna, screw it clockwise onto the antenna connector. Proxim sells several antenna alternatives, including higher gain omnidirectional and directional antennas. Each of these antennas ship with installation and mounting instructions. For information on additional antenna options, please contact your Proxim Sales Representative.

Mounting Options

The Ethernet Adapter was designed to sit on a flat surface. However, there are four pre-threaded holes on the underside of the unit so that it may be mounted on any surface. The mounting holes are shown Figure 14. These holes are a #6-32 tap and 0.175" deep. Screws and mounting tools are not provided by Proxim.

Page 32 of the Proxim 7920 user manual — 2.75”
Page 32 · click to enlarge
Page 32
Proxim 7920 — 2. Quick Installation diagram (page 32)
Fig. 14 · 2. Quick Installation

2.75”

2.10”

Figure 14 Mounting Holes

Page 33 of the Proxim 7920 user manual — Displaying the Configuration Menu
Page 33 · click to enlarge
Page 33

5. Software Configuration

You need to configure the RangeLAN2 Ethernet Adapter using the software menus if any of the following conditions apply:

K You want to set Security IDs on your network or your

existing network uses a Security ID.

K You want to set the Domain number to a value between

10 and 15.

K You want to assign the Ethernet Adapter an IP address.

K You need to change any of the software default values.

In order to configure an Ethernet Adapter, you need a terminal or terminal emulation program, such as Hyperterminal or Quarterdeck’s Procomm Plus, to access the Ethernet Adapter configuration menu. Hyperteminal is shipped with Microsoft Windows 95.

Displaying the Configuration Menu

1. Attach one end of the straight-through RS-232 cable, included in the product package, to the Ethernet Adapter and the other end to a free serial port on your terminal or PC.
2. Configure the terminal or terminal emulation package to a baud rate of 9600 bps, no parity, 8 data bits, 1 stop bit, and no flow control.
3. Apply power to the Ethernet Adapter. When the unit is ready for operation, the letter “U” will be displayed on the terminal screen. At any point while the Ethernet Adapter is operational, press to display the menu.
Page 34 of the Proxim 7920 user manual — The Ethernet Adapter’s configuration menu should look like this:
Page 34 · click to enlarge
Page 34

The Ethernet Adapter’s configuration menu should look like this:

Proxim 7920 — The Ethernet Adapter’s configuration menu should look like this: diagram (page 34)
Fig. 15 · The Ethernet Adapter’s configuration menu should loo…

Type the number of the menu option and to view the submenus. Hit at any time to back up one menu.

To simplify the menu options, all of the configuration menus will appear in a tree diagram format.

The tree diagram for the Main Menu, shown in the screen shot above looks like this:

Page 35 of the Proxim 7920 user manual — Ethernet Adapter Main Menu
Page 35 · click to enlarge
Page 35

Ethernet Adapter Main Menu

Display Parameter Values

Reset Parameters to Factory Defaults

Radio Configuration Menu

Advanced Configuration Menu

View Statistics

Download New Software Version

Reset the Ethernet Adapter

Exit

The following four chapters detail the sub-menus, shown above.

Page 36 of the Proxim 7920 user manual — 2. Quick Installation
Page 36 · click to enlarge
Page 36
Page 36 of the Proxim 7920 user manual — 2. Quick Installation
Page 37 of the Proxim 7920 user manual — 6. Radio Configuration Menu
Page 37 · click to enlarge
Page 37

6. Radio Configuration Menu

This section discusses the RangeLAN2 radio parameters that can be configured by the user.

The software tree below shows the options available in the Radio Configuration Menu:

Proxim 7920 — 6. Radio Configuration Menu diagram (page 37)
Fig. 16 · 6. Radio Configuration Menu

Dotted Line - Visible w hen configured as a M aster

Dashed Line - Visible w hen configured as a Station

Page 38 of the Proxim 7920 user manual — Radio Parameters Menu
Page 38 · click to enlarge
Page 38

Radio Parameters Menu

The table below shows the range and default values for each of the radio software parameters:

e m a N rete m ara P e g n a R tlu afe D

nia m o D e s U rof " U " d n a ,5 1-0 h ctiw S h ctiw S e s U

* le n n a h C rof 0 d n a ,5 1-1 n oitc ele s cita m otu a 0

* le n n a h c b u S 5 1-1 1

e p yT n oitatS ,n oitatS ,rets a M

h ctiw S e s U rof " U " d n a h ctiw S e s U

* e m a N rets a M sretc ara h c 1 1 R E T S A M

DI ytiru c e S sretc ara h c 0 2 k n alb

* g nita e p e R elb a n E N /Y N

* e zi m itp O C A M yre V ,th giL ,la m ro N

otu A d n a ,th giL otu A

,1 d n a tu o e m it o n rof 0 eta n gis e d ot...,3 ,2

tu o e m iT ytivitc a nI t

s d n o c e s 0 1 fo sla vretni

gifn o C m a o R t ts a F d n a ,la m ro N ,w olS la m ro N

d elb a n E g ni m a o R t o N /s e Y s e Y

oid a R te s e R - -

n e h w elbisiv yln O * rets a M a s a d eru gifn o c

t n e h w elbisiv yln O

n oitatS a s a d eru gifn o c

Page 39 of the Proxim 7920 user manual — 2. Quick Installation
Page 39 · click to enlarge
Page 39

Please note that changes to these parameters will not take affect until either the radio or the Ethernet Adapter is reset.

A RangeLAN2 Ethernet Adapter may be set as either a Master or a Station using the Station Type parameter within the configura- tion menu. You may also choose “U” for Use Switch to use the value specified by the Station/Master rotary switch. The rotary switch is set to Station by default.

Proxim’s RangeLAN2 products are frequency hopping spread spectrum radios which communicate in the 2.4GHz frequency band. This means that several times every second, the frequency at which the units are communicating changes.

In order for the units to communicate, in each subnetwork there must be one unit that coordinates the frequency hops. This unit is called the Master. It might help you to think of the Master as the conductor of a frequency hopping orchestra. The Master keeps time so all units know when to hop and to what frequency.

Units classified as Stations synchronize to the Master and follow its signal to learn what frequency in the pattern the Master is currently using.

There must be at least one unit on the network designated as the Master. In an Ad Hoc topology, there is only one master, but it does not matter which unit is designated as the Master. How- ever, in topologies where a RangeLAN2 Access Point is present, the Access Point will be the Master and each Ethernet Adapter should be set as a Station.

In small networks where a RangeLAN2 Ethernet Adapter is used as a Workgroup Concentrator, the Ethernet Adapter will be configured as the Master and all other wireless units will be configured as Stations.

Page 40 of the Proxim 7920 user manual — 2. Quick Installation
Page 40 · click to enlarge
Page 40

In order to establish communication, all Stations and the Master must be configured with the same Domain number. Radios on different Domains cannot communicate with each other. The Domain is a software filter which does not affect the actual radio frequency or the frequency hopping sequence.

You may want to set everyone on your network to the same Domain. For larger wireless networks, use the Domain to establish roaming subnetworks throughout your building. For example, the Engineering Department may use Domain 2, and the Sales Department may use Domain 5. Then engineers can only roam within the geographical area mapped out by RangeLAN2 Access Points with a Domain setting of 2.

The Domain is a number between 0 and 15. Choose “U” for Use Switch in order to use the number specified by the Domain rotary switch. The default setting is the rotary Domain switch which shipped from the factory set to Domain 0.

Note that while the rotary Domain switch allows the user to set the Ethernet Adapter to operate on a Domain number between 0 and 9, the software configuration menu allows the user to set the Domain to a number between 0 and 15. If you want to use a Domain number between 10 and 15, you must configure this parameter within the software configuration menu.

Each Master can select one of 15 Channels to establish commu- nication with its Stations. Each Channel number sets a unique frequency hopping sequence allowing for multiple subnetworks with higher data rate transmission capability in the same air space. You may think of the Channel as a pipe. In order to communicate, radios must be on the same Channel and there must be one (and only one) Master that provides the timing for that Channel.

Page 41 of the Proxim 7920 user manual — 2. Quick Installation
Page 41 · click to enlarge
Page 41

There are 15 independent Channels designated 1 through 15. This means that there are 15 different sequences of frequency hops. Each Channel is at a different frequency at a different time. To minimize interference, set each Ethernet Adapter acting as a Master within the same area to a different Domain and Channel. In networks with multiple Access Points, set each Access Point to a different Channel but the same Domain to facilitate roaming.

The Ethernet Adapter’s Channel may be set to a value between 0 and 15, and 0 is the default setting. When set to Channel 0, an Ethernet Adapter automatically selects a Channel upon boot-up based on the configured Domain number. The Channel selected is the Domain number plus 1. Therefore, if the Domain is set to 0, the Channel is 1. Note that the automatic selection procedure will choose Channel 15 when set to either Domain 14 or 15.

This parameter is visible only when the Ethernet Adapter is set as a Master. All Stations will determine their channel by the Master to which they are synchronized.

The Subchannel is a software code that is appended to each radio packet. It does not affect the frequency hopping sequence like a Channel does. Use a Subchannel if you need more than 15 Masters in the same area and, therefore, all the Channels are used. The Subchannels are designated 1 through 15, and 1 is the default setting. This parameter is visible only when the Ethernet Adapter is set as a Master.

For example, you can use Channel 1, Subchannel 1 for Network A and Channel 1, Subchannel 2 for Network B. The two net- works will not communicate with one another. They are, how- ever, still sharing the 1.6 Mbps data rate since they are both using Channel 1.

Page 42 of the Proxim 7920 user manual — 2. Quick Installation
Page 42 · click to enlarge
Page 42

The optional Master Name parameter of up to 11 characters specifies an alphanumeric name to simplify the identification of each Master in your network. You may not have spaces in the name. This parameter is visible only when the Ethernet Adapter is set as a Master.

To further improve the security of a wireless subnetwork, each unit requires the same Security ID to establish communication. The Security ID is used on all RangeLAN2 products and all Station Types. This ID is encrypted and stored within the RangeLAN2 Ethernet Adapter itself, not in software. It cannot be accessed, but you may change it. However, if you do change it, then you will need to change the Security ID on all of the other radios to the same new value to reestablish communica- tion.

The Security ID parameter can be up to 20 characters and is an empty string by default. There are 1,048,576 unique choices for the Security ID.

The Repeating Enabled parameter gives the ability to enable or disable the RangeLAN2 repeating feature. When enabled, a RangeLAN2 Ethernet Adapter, acting as a Master, will repeat signals coming from one Station and destined for another Sta- tion. These two Stations must be out of range of one another, but both in range of the RangeLAN2 Ethernet Adapter for repeating to occur.

Page 43 of the Proxim 7920 user manual — 2. Quick Installation
Page 43 · click to enlarge
Page 43

However, be aware that by enabling the repeating feature, the network throughput will drop by as much as one-half when repeating occurs.

This parameter is only visible when the Ethernet Adapter is configured as a Master. By default, Repeating is disabled. See Chapter 3 for more information on Repeating.

The MAC Optimize parameter can help improve throughput for small networks. The default setting of Auto allows the RangeLAN2 Ethernet Adapter to determine the number of units synchronized to it and to then adjust this parameter accordingly.

Alternately, you may force the parameter to one of the other settings. If you have 0 or 1 wireless nodes communicating with an Ethernet Adapter, use the Very Light setting. If you have between 2 and 7 wireless nodes communicating with an Ethernet Adapter at the same time, use Light. (You can have more than 7 nodes synchronized to an Ethernet Adapter but between 2 and 7 communicating at the same time for the Light parameter setting.) In networks with more than 7 concurrent wireless users, use Normal. The MAC Optimize parameter is visible only when the Ethernet Adapter is set as a Master.

To conserve power, the RangeLAN2 Ethernet Adapter has an Inactivity Timeout doze mode for the radio. The doze mode is automatically engaged when a certain period of time has elapsed since the unit has sent or received data over its radio. An Ethernet Adapter in doze mode will wake up when a Master unit attempts to send data to it.

There is no inactivity timeout set by default, but you may change this to any interval of 10 seconds. This parameter is visible only when the Ethernet Adapter is set as a Station.

Page 44 of the Proxim 7920 user manual — 2. Quick Installation
Page 44 · click to enlarge
Page 44

The Roam Config parameter allows you to determine how quickly an Ethernet Adapter, set as a Station, will roam from one Master Access Point to another. In areas with many RangeLAN2 Access Points that provide heavy overlapping coverage, set this parameter to Fast to maintain high throughput for each of the wireless nodes.

In most networks, set the Roam Config parameter to Normal. Wireless node throughput will not change noticeably, and an overabundance of RangeLAN2 Access Points is not required.

If the wireless coverage area provided by RangeLAN2 Access Points is sparse, set the Roam Config parameter to Slow. Wire- less nodes will not roam until they are nearly out of range of the RangeLAN2 Access Point to which they are synchronized. This parameter is visible only when the Ethernet Adapter is set as a Station.

You may choose to disable a RangeLAN2 Ethernet Adapter’s ability to roam from one Master RangeLAN2 Access Point to another with the Roaming Enabled parameter. This feature is enabled by default and is visible only when the Ethernet Adapter is set as a Station.

Page 45 of the Proxim 7920 user manual — 7. Advanced Configuration Menu
Page 45 · click to enlarge
Page 45

7. Advanced Configuration Menu

Use these parameters to configure the advanced features of the RangeLAN2 Ethernet Adapter.

Ethernet Adapter M ain M enu

Reset Parameters to Factory Defaults

Radio Configuration M enu

Advanced Configuration M enu

Set IP Address Forw arding Database Table Timeout

CPU Pow er Save M ode Echo M ode

Dow nload New Softw are Version

Reset the Ethernet Adapter

Show 4 more labels / short text on this page
Display Parameter Values · Technical Support Access · View Statistics · Exit
Page 46 of the Proxim 7920 user manual — Advanced Parameters
Page 46 · click to enlarge
Page 46

Advanced Parameters

e m a N rete m ara P e g n a R tlu afe D

s s erd d A PIte S - 0.0.0.0

e s a b ata D g nidra w ro F

tu o e m iT elb a T s d n o c e s 0 0 0,0 0 0,1 ot 0 1 0 0 3

e d o M e v a S re w o P U P C N /Y o N

e d o M o h c E d n a ,elp m iS ,e n o N

la ni m re T la ni m re T

tro p p u S la cin h c e T

s s e c c A A/N A/N

Set IP Address allows you to assign the Ethernet Adapter a unique network IP address. If the unit is attached to an Ethernet- ready device, do not assign the Ethernet Adapter the same IP address as the Ethernet-ready device. The Ethernet Adapter must have its own IP address if you choose to give it one.

The Forwarding Database Table Timeout parameter allows you to control the length of time the Ethernet Adapter will hold a learned address of a network node in its Forwarding Database Table. This data is dynamically acquired by the RangeLAN2 Ethernet Adapter so that it can forward packets properly to wired and wireless nodes. By default, a Forwarding Database Table entry will expire after 300 seconds or 5 minutes.

Page 47 of the Proxim 7920 user manual — 2. Quick Installation
Page 47 · click to enlarge
Page 47

The CPU Power Save Mode parameter will reduce the amount of power drawn by the Ethernet Adapter during operation. This is a useful feature for customer who are powering the Ethernet Adapter with a battery.

The Ethernet Adapter’s serial port supports three Echo Modes when configuring the unit through a terminal session: None, Simple, and Terminal. When set to None, the Ethernet Adapter will not echo typed characters to the terminal screen. When set to either Simple or Terminal, all characters typed are echoed to the screen during a terminal session. The Ethernet Adapter is set to Terminal mode by default. This parameter will only affect the appearance of data within the configuration menu; it plays no role in normal operation.

The Ethernet Adapter configuration menu contains several parameters that are not needed for normal operation. A pass- word is needed to enable Technical Support Access to view these settings.

If you call Proxim Technical Support, they may ask you to enable the Technical Support parameters, but, in general, you will not need to access these parameters.

Page 48 of the Proxim 7920 user manual — 2. Quick Installation
Page 48 · click to enlarge
Page 48
Page 48 of the Proxim 7920 user manual — 2. Quick Installation
Page 49 of the Proxim 7920 user manual — 8. Display Parameter Values
Page 49 · click to enlarge
Page 49

8. Display Parameter Values

The Ethernet Adapter displays all of the relevant parameters in one centralized location. By choosing “Display Parameter Values,” you can view the current and configured values for the Radio and Advanced parameters.

Current values are already in use by the Ethernet Adapter. If the configured value is different from the current value, the Ethernet Adapter must be reset before the configured value takes effect and at that time, the configured value becomes the new current value.

The diagram on the next page shows the software trees associ- ated with the Display Parameter Values menu.

Page 50 of the Proxim 7920 user manual — 2. Quick Installation
Page 50 · click to enlarge
Page 50
Proxim 7920 — 2. Quick Installation diagram (page 50)
Fig. 17 · 2. Quick Installation

M AC Optim ize Inactivity T im eout (sec.)

IP Address Filter T able T im eout (sec.)

CPU Pow er Save M ode Enabled Echo M ode

Dotted Line - Visible when configured as a Master

Dashed Line - Visible when configured as a Station

Page 51 of the Proxim 7920 user manual — 9. View Statistics
Page 51 · click to enlarge
Page 51

9. View Statistics

You can obtain operating statistics for the RangeLAN2 Ethernet Adapter from the View Statistics menu. The following diagram illustrates the software tree:

Proxim 7920 — 9. View Statistics diagram (page 51)
Fig. 18 · 9. View Statistics
Page 52 of the Proxim 7920 user manual — Radio Statistics
Page 52 · click to enlarge
Page 52

Synchronized To Statistic

This statistic displays the Master Name of the RangeLAN2 product, acting as a Master, to which the RangeLAN2 Ethernet Adapter is synchronized. If the Ethernet Adapter is set as a Master, it will be synchronized to itself and display its own Master Name.

Ethernet Statistics

This category displays information about the packets sent and received through the Ethernet Adapter's Ethernet port. Additional statistics report the number of errors, Ethernet collisions, and missed packets encountered by the unit through its Ethernet connection.

The Frame Align Errors statistic records the number of packets which were not successfully received by the unit's Ethernet port.

The CRC Errors statistic records the number of corrupt packets the Ethernet Adapter reads from the Ethernet.

The Receive Overflow statistic records the number of times the unit's Ethernet buffers are filled beyond capacity by Ethernet traffic.

The Packets Filtered statistic shows the number of Ethernet packets the Ethernet Adapter has not forwarded to the wireless network based on information the unit has learned concerning the location of network nodes.

Radio Statistics

This category displays information about the packets sent and received through the radio interface.

Page 53 of the Proxim 7920 user manual — Range
Page 53 · click to enlarge
Page 53

10. Performance Hints

This section provides ideas for how to increase performance with Proxim wireless products.

Microwave Ovens

Microwave ovens operate in the same frequency band as RangeLAN2. Therefore, if you use a microwave within range of RangeLAN2 products, you may notice network performance degradation. However, both your microwave and your RangeLAN2 network will continue to function.

Range

Every environment is unique with different obstacles, barriers, materials, etc. and, therefore, it is difficult to determine the exact range that will be achieved without testing. Proxim has devel- oped some guidelines to estimate the range that users will see when the RangeLAN2 7920 Ethernet Adapter is installed in their facility, but there are no hard and fast specifications. Note that the RangeLAN2 7921 Ethernet Adapter will have greater range.

Radio signals may reflect off of some obstacles or be absorbed by others depending on their construction. For example, with two RangeLAN2 radios you may achieve up to 1000' in open space outdoors where the two antennas are line of sight, meaning they see each other with no obstacles. However, the same two units will only achieve up to 500' of range when they have to travel through the cubicles usually used in modern offices. If there are office walls to penetrate, the signal range may decrease even further to up to 300'.

Page 54 of the Proxim 7920 user manual — K Two antennas that are communicating should be in the
Page 54 · click to enlarge
Page 54

If you are interested in antenna options, contact your Proxim Sales Representative about antenna kits.

Proper antenna placement can help improve range. Here are some guidelines:

K The antenna should be placed in a vertical position.

K Do not place a sheet of metal (like a filing cabinet)

between two antennas.

K Two antennas that are communicating should be in the

same plane. For example, do not lie one antenna on its side and have its partner standing upright.

Page 55 of the Proxim 7920 user manual — Fixed Node Filtering on RangeLAN2 Access Points
Page 55 · click to enlarge
Page 55

11. Troubleshooting

The RangeLAN2 792x Ethernet Adapter is designed to be very easy to install and operate. If you do experience difficulties, however, use the information in this chapter to help diagnose and solve problems. If you cannot resolve a problem, contact Proxim, as described in Appendix E, “How to Reach Technical Support.”

How to Obtain Help with Your Product Installation

If you require assistance to install your Ethernet Adapter, Proxim can put you in touch with a RangeLAN2 Reseller in your area. The reseller is an expert in the design, installation, and mainte- nance of wireless communication products and will be able to examine your needs and recommend the most cost-effective wireless solution for you. For the location of the RangeLAN2 reseller nearest you, contact Proxim at 800-229-1630 and ask for the Sales Department.

Fixed Node Filtering on RangeLAN2 Access Points

Proxim's RangeLAN2 Access Points are designed to prevent packets destined for a wired node from being transmitted to the wireless networks. Each Proxim RangeLAN2 product has a unique MAC address which begins with 00:20:A6. By default, packets destined for a MAC address which does not have the RangeLAN2 prefix are not transmitted to the wireless network by the Access Point. This process is called Fixed Node Filtering, Filter Fixed Nodes, or NON-RangeLAN2 Address Filter.

However, an Ethernet-ready device attached to the Ethernet Adapter will not have a MAC address with the RangeLAN2

Page 56 of the Proxim 7920 user manual — 2. Quick Installation
Page 56 · click to enlarge
Page 56

prefix. Therefore, an Access Point will filter out packets destined for these devices, and these devices will not be able to communi- cate through the Access Points with the wired network.

This is not an issue for Ethernet Access Points with revision 1.4 or greater of the flash code image installed. Proxim has modified the flash code for these Access Points to allow non-RangeLAN2 devices attached to an Ethernet Adapter to communicate with the wired network without having to disable the Fixed Node Filtering parameter. Note that in order for the Access Point to pass packets destined for these non-RangeLAN2 addresses to the wireless network, it must first learn of their existence. Therefore, each non-RangeLAN2 device must send a packet through the Access Point before the Access Point will begin to forward packets to it. This should not be pose a problem for the majority of networks.

However, if the network contains a Token Ring Access Point or the earlier mode of the RangeLAN2 Ethernet Access Point (model 7500), then the Fixed Node Filtering parameter must be disabled to allow packets destined for non-RangeLAN2 addresses to be transmitted to the wireless network. Note that transmitting packets destined for non-RangeLAN2 addresses may cause the overall wireless performance to decline.

If the Ethernet Adapter has Roaming Enabled, each Access Point to which the Ethernet Adapter may synchronize must be reconfigured so that Fixed Node Filtering is disabled. Therefore, if your Ethernet Adapter will be a stationary device, you should disable roaming in the Ethernet Adapter's Radio Configuration Menu so that Fixed Node Filtering will only need to be disabled on one Access Point on your network.

The procedure for disabling Fixed Node Filtering differs depend- ing on the model of the RangeLAN2 Access Point. Consult your Access Point manual for additional information.

Page 57 of the Proxim 7920 user manual — Below is a summary for changing this parameter on each model:
Page 57 · click to enlarge
Page 57

Below is a summary for changing this parameter on each model:

Model 7500: Uncheck the NON-RangeLAN2 Address Filter on the Filter Configuration page of the 7500's Configuration Tool.

Model 7510/752x: No action is needed if the Access Point has revision 1.4 or greater of the flash code image installed. If the Access Point is using an earlier version of the flash code, set the Filter Fixed Nodes parameter to “Not Filtering” in the Filter Configuration Menu.

Model 753x, operating in TB or Single-Ring SR/TB mode: There is no Filter Fixed Nodes parameter when operating the Token Ring Access Point in these bridging modes. Instead, you may configure the Access Point to forward packets destined for up to 3 MAC address prefixes in addition to the RangeLAN2 prefix. These MAC address prefixes may be set in the Hardware Filtering Configuration Menu.

Model 753x, operating in Multi-Ring SR/TB mode: Set the Filter Fixed Nodes parameter to "Not Filtering" in the Filter Configuration Menu.

Page 58 of the Proxim 7920 user manual — 1 blink: Could not initialize Ethernet interface
Page 58 · click to enlarge
Page 58

LED Error Codes

The main power LED located on the top of the Ethernet Adapter will flash red in repeating patterns to indicate the following errors:

1 blink: Could not initialize Ethernet interface

2 blinks: Memory check failed

3 blinks: Software error

4 blinks: Failed to initialize the radio

5 blinks: Memory full

6 blinks: Ethernet interface error

7 blinks: Miscellaneous error

If you see any of the above flashing sequences, first attempt to reset the Ethernet Adapter. If the flashing sequence persists after you have reset the unit, make a note of which of the above pat- terns you have and call Proxim Technical Support.

Page 59 of the Proxim 7920 user manual — Commonly Asked Technical Support Questions
Page 59 · click to enlarge
Page 59

Commonly Asked Technical Support Questions

n oits e u Q m otp m y S/ m elb or P re w s n A/n oitulo S elbis s o P s're s U niretp a h C

e htfi w o n k I o d w o H

e p yT n oitatS ro nia m o D e htre htie fI

e ht g nis u siretp a d A te nre htE

n e d dirre v o n e e b e v a h h ctiw s yrator

ro h ctiw s e ht n o s g nitte s e ht

e ht,era wtfo s n oitaru gifn o c e ht y b

e ht y b te s s g nitte s e ht

e ht n o d eta c ol,D E L e dirre v o w olle y

? era wtfo s n oitaru gifn o c

.eta ni m ullilliw ,tin u e htfo e dis k c a b

te nre htE e ht eru gifn o c t'n a c I

si n ois s e s la ni m ret e htta ht yfire V .1

laire s e ht aiv ylla c olretp a d A

.1 N 8 0 0 6 9 otte s

.tro p

a g nis u era u o y ta ht yfire V .2

.elb a c 2 3 2- S R h g u orht-th giarts

to n s e o d D E L k niL e h T

te nre htE e ht hto b ta ht yfire V .1

a g ulp I n e h w eta ni m ulli

y d a er-te nre htE e ht d n a retp a d A

te nre htE e ht n e e wte b elb a c

.p u d ere w o p era e civ e d

re hto n a d n a retp a d A

te nre htE e ht g nitc e n n o c era u o y fI .2

.e civ e d y d a er-te nre htE

dra d n ats a htiw e civ e d a otretp a d A

era u o y ta ht m rifn o c ,tro p te nre htE

fI .elb a c T e s a B 0 1 dra d n ats a g nis u

m rifn o c ,b u h a ot g nitc e n n o c era u o y

-s s orc T e s a B 0 1 a g nis u era u o y ta ht

.elb a c re v o

n o elb a c T e s a B 0 1 ru o y ts e T .3

e htta ht eru s n e ot n oitc e n n o c re hto n a

.e vitc efe d to n si elb a c

y b d etc effa si D E L k niL e h T .4

e h T .ytirg etni k nil s a lle w s a ytivitc a

te nre htE e ht n e h w k nilb lliw D E L

stire v o ste k c a p sti m s n artretp a d A

e ht n e h W .n oitc e n n o c T- E S A B 0 1 dlu o h s u o y ,ylre p orp g nitare p o sitin u

e b yllare n e g ot D E L k niL e httc e p x e

k nilb o sla tu b n e erg y d a ets a

.ylla n ois a c c o

e ht n e h w lletI n a c w o H

e htta ht eru s e k a m ot k c e h C .1

siretp a d A te nre htE

.n o si D E L h c n y s n oitatS w olle y

s s e c c A y m ot d e zin orh c n y s

retp a d A te nre htE e ht k c e h C .2

rets a M e ht e e s ot u n e M s citsitatS

e ht h cih w ottin u e htfo e m a N

.d e zin orh c n y s siretp a d A te nre htE

e diu G · 9 ,4 · ?tnio P

Page 60 of the Proxim 7920 user manual — 2. Quick Installation
Page 60 · click to enlarge
Page 60

n oits e u Q m otp m y S/ m elb or P re w s n A/n oitulo S elbis s o P s're s U niretp a h C

s s eleriw a h silb ats e t'n a c I

te s siretp a d A te nre htE e htta ht yfire V

te nre htE e ht htiw n oitc e n n o c

DI ytiru c e S d n a nia m o D e m a s e ht ot

.retp a d A

ni stc u d orp 2 N A L e g n a R re hto e ht s a

.kro wte n ru o y

,n oitc e n n o c s s eleriw a e v a h I

e ht g nis u era u o y ta ht yfire V .1

y d a er-te nre htE y m tu b

e ht n e e wte b elb a c te nre htE re p orp

eta cin u m m o c t'n a c e civ e d

-te nre htE e ht d n a retp a d A te nre htE

.kro wte n e ht htiw

.e civ e d y d a er

y d a er-te nre htE ru o y ta ht yfire V .2

n oita cilp p a g nikro wte n sti d n a e civ e d

e m a s e ht g nis u eta cin u m m o c

re hto e ht y b d e s u si s a lo c otorp

.kro wte n ru o y n o s e d o n

.w ols s m e e s tu p h g u orht e h T ,tu p h g u orht m u m ix a m e v eih c a o T

-lle w era s a n n etn a ru o y ta ht yfire v

ere ht d n a ,late m d nih e b to n ,d e c alp

.s elc ats b o y n a m o otto n era

s s e c c a otte nlet e s u I n a C

era wtfo s s'retp a d A te nre htE e h T .o N

s'retp a d A te nre htE e ht

h g u orht d e s s e c c a e b yln o n a c u n e m

? u n e m n oitaru gifn o c

.tro p laire s e ht

e diu G

Page 61 of the Proxim 7920 user manual — A. Menu Structure
Page 61 · click to enlarge
Page 61

A. Menu Structure

Proxim 7920 — A. Menu Structure diagram (page 61)
Fig. 19 · A. Menu Structure

M AC Optim ize Inactivity T im eout (sec.)

IP Address Filter T able T im eout (sec.)

CPU Pow er Save M ode Enabled Echo M ode

Dotted Line - Visible w hen configured as a M aster

Dashed Line - Visible w hen configured as a Station

Page 62 of the Proxim 7920 user manual — 2. Quick Installation
Page 62 · click to enlarge
Page 62
Proxim 7920 — 2. Quick Installation diagram (page 62)
Fig. 20 · 2. Quick Installation

Dotted Line - Visible w hen configured as a M aster

Dashed Line - Visible when configured as a Station

Page 63 of the Proxim 7920 user manual — 2. Quick Installation
Page 63 · click to enlarge
Page 63

Ethernet Adapter M ain M enu

Reset Parameters to Factory Defaults

Radio Configuration M enu

Advanced Configuration M enu

Set IP Address Forw arding Database Table Timeout

CPU Power Save M ode Echo M ode

Dow nload New Softw are Version

Reset the Ethernet Adapter

Show 4 more labels / short text on this page
Display Parameter Values · Technical Support Access · View Statistics · Exit
Page 64 of the Proxim 7920 user manual — 2. Quick Installation
Page 64 · click to enlarge
Page 64
Proxim 7920 — 2. Quick Installation diagram (page 64)
Fig. 21 · 2. Quick Installation
Page 65 of the Proxim 7920 user manual — B. Parameters
Page 65 · click to enlarge
Page 65

B. Parameters

Radio Parameters

e m a N rete m ara P e g n a R tlu afe D

nia m o D e s U rof " U " d n a ,5 1-0 h ctiw S h ctiw S e s U

* le n n a h C rof 0 d n a ,5 1-1 n oitc ele s cita m otu a 0

* le n n a h c b u S 5 1-1 1

e p yT n oitatS ,n oitatS ,rets a M

h ctiw S e s U rof " U " d n a h ctiw S e s U

* e m a N rets a M sretc ara h c 1 1 R E T S A M

DI ytiru c e S sretc ara h c 0 2 k n alb

* g nita e p e R elb a n E N /Y N

* e zi m itp O C A M yre V ,th giL ,la m ro N

otu A d n a ,th giL otu A

,1 d n a tu o e m it o n rof 0 eta n gis e d ot...,3 ,2

tu o e m iT ytivitc a nI t

s d n o c e s 0 1 fo sla vretni

gifn o C m a o R t ts a F d n a ,la m ro N ,w olS la m ro N

d elb a n E g ni m a o R t o N /s e Y s e Y

oid a R te s e R - -

n e h w elbisiv yln O * rets a M a s a d eru gifn o c

t n e h w elbisiv yln O

n oitatS a s a d eru gifn o c

Page 66 of the Proxim 7920 user manual — Advanced Configuration Parameters
Page 66 · click to enlarge
Page 66

Advanced Configuration Parameters

e m a N rete m ara P e g n a R tlu afe D

s s erd d A PIte S - 0.0.0.0

e s a b ata D g nidra w ro F

tu o e m iT elb a T s d n o c e s 0 0 0,0 0 0,1 ot 0 1 0 0 3

e d o M e v a S re w o P U P C N /Y o N

e d o M o h c E d n a ,elp m iS ,e n o N

la ni m re T la ni m re T

tro p p u S la cin h c e T

s s e c c A A/N A/N

Page 67 of the Proxim 7920 user manual — The steps for downloading a new image are:
Page 67 · click to enlarge
Page 67

C. Procedure for Downloading New Software

At some point in the future, you may need to upgrade the RangeLAN2 Ethernet Adapter software. To do this, choose the Download New Software Version option from the Main Menu. You need to use the XMODEM protocol to complete the download. Commonly used serial communication programs, such as Hyperterminal and Procomm Plus, support the XMODEM protocol.

The steps for downloading a new image are:

1. Place the new software file on the computer's hard drive, a floppy disk, or a network server.
2. Attach the Ethernet Adapter to a free serial port on the computer using an RS-232 cable.
3. Open a terminal screen and set the serial port settings to 9600 bps, 8 data bits, 1 stop bit, no parity.
4. Bring up the Ethernet Adapter configuration menu by typing in a terminal screen when the unit is powered up.
5. Choose Download New Software Version from the Main Menu.
6. You will be prompted to send a file containing the software version using the XMODEM protocol.
7. When the download is successful, the Ethernet Adapter will automatically reboot using the new software.
Page 68 of the Proxim 7920 user manual — 2. Quick Installation
Page 68 · click to enlarge
Page 68
Page 69 of the Proxim 7920 user manual — D. Glossary
Page 69 · click to enlarge
Page 69

D. Glossary

10BASE-T Cross-over Cable — A standard 10BASE-T Ethernet cable with pins 1 & 3 and 2 & 6 crossed to allow two Ethernet devices with the same pin specification to communicate directly with one another.

Access Point — An internetworking device that seamlessly connects wired and wireless networks together.

Bandwidth — The size (in Hertz) of the frequency range that a signal transmission occupies. Typical narrow band signals oc- cupy a 25 KHz bandwidth. The RangeLAN2 signal occupies a 1 MHz bandwidth.

Channel — In RangeLAN2 networks, the channel refers to the frequency hopping sequence the card follows.

CSMA/CA — (Carrier Sense Multiple Access/Collision Avoid- ance) — CSMA is a protocol in which each node senses whether or not a channel is in use before attempting to transmit informa- tion. CA is an optimization by which channel time is reserved to avoid collisions.

DCE — (Data Communication Equipment) — A device, such as a modem, which connects to a DTE with a serial cable, that allows a DTE to send and receive data with remote locations.

DTE — (Data Terminal Equipment) — A device, such as a computer or dumb terminal, which connects to a DCE from its serial port in order to send and receive data with remote locations.

Download Image — A software file that is used to upgrade the software code running on the Ethernet Adapter.

Page 70 of the Proxim 7920 user manual — 2. Quick Installation
Page 70 · click to enlarge
Page 70

Filtering — An action performed by an Ethernet device, such as a bridge, switch, or router, which excludes an Ethernet packet from being passed from one subnetwork to another based upon the packet's destination, source, or packet type.

Frequency Hopping — A spread spectrum technique by which the band is divided into a number of channels and the transmis- sions hop from channel to channel in a pre-specified sequence.

Interference — A situation that occurs when an unwanted RF signal occupies the same frequency band as a desired signal.

IP Address — (Internet protocol address) — A 32-bit address assigned to TCP/IP hosts.

Narrow Band — A channel of about 25 KHz bandwidth in the RF spectrum. The FCC allocates Narrow Band channels and issues a license to the user. Each user of a specific narrow band frequency range must obtain a site license from the FCC.

Spread Spectrum — A radio data transmission modulation technique by which the transmitted signal is spread over a band- width wider than the information bandwidth. Spread Spectrum bands are designated by the FCC and require no user license.

TCP/IP — Transmission Control Protocol/Internet Protocol. A suite of protocols developed under DARPA sponsorship for internetworking.

Page 71 of the Proxim 7920 user manual — K What are the configuration settings?
Page 71 · click to enlarge
Page 71

E. How to Reach Technical Support

If you’re having a problem using the RangeLAN2 792x Ethernet Adapter and can’t resolve it with the information in Chapter 11, gather the following information and contact Proxim Technical Support:

K What are the configuration settings?

K What were you doing when the error occurred?

K What error message did you see?

K Can you reproduce the problem?

K What version of the Ethernet Adapter software are you

using?

You can reach Proxim Technical Support by voice, fax, email BBS, or mail:

Tel: 800-477-6946 or 650-526-3640 Fax: 650-960-1106 Web: http://www.proxim.com Email: support@proxim.com BBS: 650-960-2419 (14400 bps, N/8/1)

Proxim, Inc. AttnTechnical Support 295 N. Bernardo Ave. Mountain View, CA 94043
Page 72 of the Proxim 7920 user manual — F. U.S. Specifications
Page 72 · click to enlarge
Page 72

F. U.S. Specifications

The following technical specification is for reference purposes only. Actual product's performance and compliance with local telecommunica- tions regulations may vary from country to country. Proxim, Inc. will only ship products that are type approved in the destination country.

Network Interface Ethernet 10BaseT (Twisted-Pair)

Data Rate 1.6 Mbps — RangeLAN2 10 Mbps — Ethernet

Media Access Protocol RangeLAN2 CSMA/CA

Ethernet compatibility Ethernet packet types and Ethernet Addressing

Frequency Band 2.4-2.483 GHz (in the U.S.) (spread spectrum frequency hopping)

Output Power 100 mW or 500mW depending on the country

Operating Temperature -20°C to +60°C

UL Listed Power Supply The adapter requires an external power supply. If

you have elected not to purchase the external supply from Proxim or need a replacement, you must use only a UL listed, Class 2 power supply, rated min. 1A between 6 and 15VDC.

FCC Notice Warning! It is the responsibility of the installer of the antenna, as well as the responsibility of the user of this product, to guarantee that the antenna is operated at least 15 cm (6 inches) from any person. This is necessary to ensure that the product is operated in accordance with the RF Guidelines for Human Exposure which have been adopted by the Federal Communications Commission.

Independent Channels 15

Page 73 of the Proxim 7920 user manual — E
Page 73 · click to enlarge
Page 73

Index

10BASE-T 7, 15, 22, 66 Cross-over Cable 15, 22

A

Access Point. See RangeLAN2Access Point Ad Hoc 9, 33 Antenna 3, 5, 25 , 47, 66

Channel 12, 32, 34–35 Collisions 46 Configuration Menu 28, 29 Advanced Configuration Menu. See Advanced Configuration Menu Displaying Menu 27 Parameter Tables 59–60 Radio Configuration Menu. See Radio Configuration Menu Configured Parameter Value 43 CPU Power Save Mode 41 CRC Errors 46 Cross-over Cable. See 10BaseT: Cross-over Cable CSMA/CA 63, 66 Current Parameter Value 43

D

DCE 23, 63 Display Parameter Values 43–44 Configured Value. See Configured Parameter Value Current Value. See Current Parameter Value Domain 5, 6, 12, 13, 20, 27, 32, 34 Domain Rotary Switch. See Rotary Switch: Domain Download New Software Version 61–62 DTE 63

E

Echo Mode 41 Ethernet LED 19. See also LEDs Ethernet Statistics 46

Page 74 of the Proxim 7920 user manual — P
Page 74 · click to enlarge
Page 74

F

FCC ii, 66 Filter Fixed Nodes. See Fixed Node Filtering Filtering 64 Fixed Node Filtering 49–51 Forwarding Database Table Timeout 40 Frame Align Errors 46 Frequency Hopping. See Spread Spectrum: Frequency Hopping

Inactivity Timeout 32, 37 Installation

How to Obtain Help 49 IP Address 27, 40, 64

LED Error Codes 52 LEDs 18 Link LED 7, 20. See also LEDs

M

MAC Optimize 32, 37 Macintosh 9 Master 12, 15, 16, 17, 20, 32, 33. See also Station Type Master LED 20, 21. See also LEDs Master Name 32, 36 Microwave Ovens 47 Mount 25

O

OSI Model 1 Override LED 20. See also LEDs

P

Packets Filtered 46

Page 75 of the Proxim 7920 user manual — T
Page 75 · click to enlarge
Page 75

R

Radio Configuration Menu 31–38. See also Configuration Menu Radio LED 19. See also LEDs Radio Statistics 46 Range 47 RangeLAN2 1, 3, 9, 10, 11, 14, 66 Access Point 2, 10, 11, 12, 13, 14, 33, 38, 49–51 Extension Point 2, 38 Family 1, 2 RangeLAN2 Access Point 12, 13, 14 Receive Overflow 46 Repeating 16, 32, 36 Reset Radio 32 RMA i Roam Config 32, 38 Roaming 10, 12, 13, 32, 34, 38, 50 Rotary Switch 17, 20 Domain 17 Station/Master 33. See Rotary Switch: Domain

S

Security ID 5, 12, 27, 32, 36 Serial Port 23, 24, 27 Spread Spectrum 1, 64 Frequency Hopping 34, 64, 66 Station 16, 17, 20, 32, 33. See also Station Type Station Type 20, 32, 33 Station/Master Rotary Switch. See Rotary Switch: Station Type Statistics. See View Statistics Status LED 18, 19. See also LEDs Subchannel 12, 32, 35 Switch. See Rotary Switch Sync LED 7, 20, 21. See also LEDs Synchronized To Statistic 46

T

Technical Support 41, 52, 65 Commonly Asked Questions 53–54 Support Parameters 41

Page 76 of the Proxim 7920 user manual — XMODEM 61
Page 76 · click to enlarge
Page 76

Operating 66 Terminal 27, 61 Token Ring 2, 10, 51

U

U.S. Specifications 66–67 UNIX 9

W

Workgroup Concentrator 14, 33

XMODEM 61

Temperature · View Statistics 45

Ask about the Proxim 7920

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Proxim 7920

Be the first to ask — other owners or our team will answer.

Original document

Proxim 7920 manual PDF

76 pages·584 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%