P/N 70443r2

The QuickBridge is a complete kit for enabling a wireless broad bandwidth link between two locations. The equipment is pre-configured at the factory to be mounted and connected to your LAN network. Both ends of the link are provided in this kit along with cables and mounting hardware.
The product’s principle components consist of a radio unit and a power & Ethernet adapter. The radio is an all- in-one, outdoor unit with an integrated antenna, designed to be mounted on a pole or on a tower structure.
Power and Ethernet connections to the radio unit are supplied through a UV-protected, CAT 5 cable attached to the power & Ethernet adapter. The power & Ethernet adapter should be located inside a building. A straight cable is required when connecting to a PC and a crossover cable when connecting to a hub or switch.
The Tsunami QuickBridge II must be installed professionally.
Perform the following steps in this chapter to install the QuickBridge II system:
You should have the following tools available before installing the Tsunami QuickBridge II radios:
connecting to a hub or a switch.
GPS: 25 feet (approx. 8 m) T1/E1: 655 feet (approx. 200 m) Power/Ethernet: 246 feet (approx. 75 m)
Maximum cable length from the power source to the QuickBridge unit is 75 m, but the cable from the power source to the next device is a total of 100 m. So if you connect a 75 m cable to the QuickBridge unit, you can use a 25 m cable to connect the power supply to your PC or switch.

The product’s shipping boxes should be left intact and sheltered until arrival at the installation site. Carefully unpack the Tsunami QuickBridge II shipment and check for any shipping damage or missing parts. There are two sets of equipment in the box, as displayed in the following figure.

The Tsunami QuickBridge II T1/E1 Quick Install Guide and a Documentation and Software CD also are included in the shipment. (Extra screw-on caps to seal unused connector ports are also provided.)

Contact Technical Support regarding any missing or damaged parts.
(1) If the shipping container shows signs of damage, immediately notify the transportation company. Upon
receipt, inspect contents to ensure no parts are missing or damaged. (2) Save the original shipping boxes to re-use for shipping the equipment back to the factory, for storage, or for
re-shipping the equipment to another location.

Proxim recommends that you pre-assemble the radio mounting hardware on the ground to familiarize yourself with the equipment and check for any possible damaged or missing components before mounting the radios. This includes attaching the mounting bracket and loosely attaching the washers, lock washers, and lock nuts to the radios. Installers having prior installation experience may choose to skip this step and proceed with Step 3.
grade than a standard cable.
Perform these steps on each radio to pre-assemble the mounting hardware on the radios:








When you initially install the radios, you should configure the radios in the same room. A brief overview of the recommended computer/network configuration follows.
An interface cable with an 8-pin DIN connector and a weather-tight RJ45 cable are supplied in the product package. You also can construct your own interface cable. See “Constructing an Interface Cable” in Tsunami QuickBridge II T1/E1 Installation and Management for instructions.
GPS: 25 feet (approx. 8 m) T1/E1: 655 feet (approx. 200 m) Power/Ethernet: 246 feet (approx. 75 m)
Maximum cable length from the power source to the QuickBridge unit is 75 m, but the cable from the power source to the next device is a total of 100 m. So if you connect a 75 m cable to the QuickBridge unit, you can use a 25 m cable to connect the power supply to your PC or switch.
All cable and waveguides used should be UL-approved for the appropriate environment.
The following steps detail how to connect the cables between the radio, power & Ethernet adapter, and your network.
For each radio/power & Ethernet adapter set, perform these steps:


To directly connect the radio to a PC, use a straight-through Ethernet cable between the network interface card in the PC and the RJ45 port on the power & Ethernet adapter.

adapter is 75 meters. If you are connecting the radio through a hub or switch, the maximum length of the two CAT 5 cables is 75 feet; for example, if the cable between the radio and the power supply is 50 feet, the cable between the power & Ethernet adapter and the PC can be only 25 feet, for a total length of 75 feet.

To connect the Power & Ethernet Adapter to a switch or a hub, use a crossover Ethernet cable.

For information about constructing your own interface cable, see “Constructing an Interface Cable” in QuickBridge II T1/E1 Installation and Management.
outlet or disconnect the 8-pin DIN connector from the Power & Ethernet Adapter.
one another.
Before mounting the radios, Proxim recommends a back-to-back test of the radio pair, using one PC per radio. Back-to-back testing is a simple way to verify that the radios are fully operational before they are installed.
The process of installation adds several variables that can add to system turn-up delays during troubleshooting (such as antenna alignment, cabling, and path dynamics). Back-to-back testing can eliminate link problems caused by auxiliary equipment, installation, or the radio path, and isolates potential radio hardware problems.
repair.
When the equipment is connected as shown in the following figure, a wireless link should be established.


F IBER S OUND A BSORPTION P AD
STEP 6. INSTALL THE SOFTWARE
The QuickBridge II includes configuration software (the QuickBridge Manager), which provides basic setup and operating capabilities. Before installing the software, be sure you have configured the radios as described in “Step 4. Connect the Cables.”
To install the QuickBridge Manager:



Before configuring the QuickBridge II with the Manager program, you must:
These tasks are covered in the following procedure:

interfering with one another.
The radios are now ready for any optional configuration steps, and can establish a wireless link.
Selecting a Location
When selecting a location in which to install the radios, keep the following points in mind:
If necessary, disconnect the cables you used to configure the radios inside, move the radios to their outdoor locations, and then connect them to the network segments you want to bridge.
After you connect each radio to its network segment, make sure you install the configuration software on the two PCs used to control the radios (one PC per radio). Use the configuration software to assign each radio a valid and unique IP address for the network segment to which it is attached.
Be sure to properly weatherproof outdoor connections. See “Weatherproofing Connections” in Tsunami QuickBridge II T1/E1 Installation and Management.

The radio is designed to mount directly to a pole. Using optional mounting brackets, you can mount the radio to a wall or other flat surface (see “Mounting the Radio to a Flat Surface”).



To mount the radio to a flat surface:
to attach a ground wire to each radio. Use proper wire grounding techniques in accordance with your local electrical codes. You also can mount the radios on tall, multi-section poles with guide wires. For these types of installations, you should consult professionals with experience.
A cellular telephone or two-way radio may be useful for coordinating alignment activities between both ends of the link. Perform a general alignment of the antennas on both ends of the path using binoculars, compass, GPS, or other related tools. You must align the antennas as accurately as possible before passing traffic over the link. This will help in getting the system running more rapidly.
It is critical that you perform antenna alignment on one end of the link at a time, with the other end remaining stationary. In some cases, you may need to perform coarse alignment using a wide arc in both azimuth and elevation while listening to the audio alignment tone to find the main beam of the opposite end antenna.
For information about using the Receive Signal Quality feature to fine-tune alignment, see “Aligning Antennas with QuickBridge Manager” in Tsunami QuickBridge II T1/E1 Installation and Management.
in its aligned position.

From the Connection window, click on Discover Radio(s). The QuickBridge Manager program should discover all local radios and display the IP address of each discovered unit in the Radio(s) Available field.
Manager to connect to the specified radio.
QuickBridge Manager for configuration.
set to 192.168.20.51.
Once you have selected the radio in which you are interested, click the Login button. For first-time configuration, you should login to the Master radio. You may have to clear the ARP table in the PC if there was a previous entry for 192.168.20.56.
To change settings:
The radios are shipped from the factory without preset passwords; click the OK button to log in at the Admin level.
table in the PC if there was a previous entry for 192.168.20.56.

changing passwords.


currently selected, Local or Remote. You can change the currently selected radio by clicking the radio button to the left of the selection.

From the Link Status window, review the current status of both ends of the QuickBridge link; in this case, the locally connected radio (Master) and the remote radio (Slave). This window is updated as changes occur.


If you are having a problem using a Tsunami QuickBridge product and cannot resolve it with the information in “Troubleshooting” in the Installation and Management manual, gather the following information and contact Proxim Technical Support:
Be sure to:
number is required to obtain support and can be found only on the back of the unit.
To ask a question of Technical Support, be sure to include the part number and the serial number of the product or products in question. We cannot respond to your inquiry without this information.
To contact Proxim Technical Support by telephone, dial
1-866-674-6626 (Domestic) or 1-408-542-5390 (International)
Telephone support hours are 6:00 am to 5:00 pm Monday through Friday, PST.
To contact Technical Support online, or to see whether answers to your questions already exist, access Proxim’s Support Knowledgebase at http://support.proxim.com/
Proxim’s ServPak program delivers premium support services that complement your Tsunami QuickBridge standard warranty. Available services include, warranty extension, 24x7x365 technical phone support and priority response, and next day priority hardware replacement. For more information, contact Proxim or your Proxim authorized reseller.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.