to VTrak E-Class C ONNECTION G UIDE
Version 0.81
© 2008 Promise Technology, Inc. All Rights Reserved.

This document contains the following topics and tasks:
This Guide describes how to connect an Intel® MFSYS25 Modular Server System (Modular Server) to a VTrak E610s or E310s subsystem (VTrak) to expand the Modular Server’s data capacity. These instructions are limited to the making the Modular Server-to-VTrak connection and related settings.
For information about setting up your VTrak, see the printed VTrak Quick Start Guide or the VTrak Product Manual on the software CD that came with your subsystem.
For information about setting up your Modular Server, see the Intel® Modular Server System MFSYS25 Quick Start User’s Guide, the Modular Server System MFSYS25 User Guide, and other related documents.
IT managers want the ability to assign LUNs to individual servers. On Modular Server, you can do that easily in the Intel® Module Server Control GUI. But the GUI was not designed to work with an external storage device such as VTrak. As a result, the GUI does not report the World Wide Number (WWN) of each Compute Module (blade server). The WWN is used for the SAS initiator name, and you need the initiator name to associate a LUN with a blade server.
The tasks in this document enable you to identify the WWN of each Modular Server blade server and associate a LUN with the blade server using Promise WebPAM PROe, the GUI that runs on VTrak.

Logical Drive and LUN Numbering Strategy
A suggested strategy is to create a logical drive for each blade server. Each logical drive has its own LUN. The LUN is 0 so the blade server can boot from it.
This strategy is followed throughout this document. You are free to use a different strategy that better meets your needs.
The Modular Server-to-VTrak connection requires:

The Modular Server Control (MSC) log-in screen appears.
The Username and Password are case sensitive.
Figure 1. MSC login screen

After log-in, the MSC Dashboard screen appears.

Figure 2. MSC Dashboard screen


The Modular Server has external ports that each blade server can access. The port numbers correspond to the slot number of each blade server. To enable a port is to enable the external data connection, in this case, to access a LUN on the VTrak.
To enable the external ports:
Figure 3. MSC Chassis Back screen
Chassis Back tab SCM 1 Actions menu SCM 1

Later in the process, you will return to this Task to enable another external port, until all the ports are enabled. Enable just one port at a time.

Figure 4. MSC Expansion Port dialog box

Server 1’s external port is now enabled. It will appear as a SAS initiator in WebPAM PROe. In “Task 7: Associating LUNs and Initiators” on page 16, you will associate this port or initiator with a LUN.

If you plan to attach a SAS cable to Storage Controller 2, be sure you connected the other end of the cable to one of the SAS data ports (diamond icon) on the other VTrak controller. See Figure 5.
Figure 5. Modular Server-to-VTrak SAS connections
SAS data ports (diamond icon)

SAS ports on Storage Controllers
Flip the switch on both power supplies to the ON position.

You must first set up a serial connection between the VTrak and your PC. Then you can run Microsoft HyperTerminal to access the VTrak’s command line interface (CLI) to find the IP address.
This procedure requires the RJ11-to-DB9 serial data cable supplied with the VTrak and includes the following actions:
To set up a serial connection:
Figure 6. The VTrak serial connector

To access the VTrak’s CLI:
RJ11 Serial Connector

At this point, you are in the CLI.
=========================================== CId Port Type IP Mask Gateway Link =========================================== 1 1 Mgmt 192.168.10.85 255.255.255.0 192.168.10.1 Up
In this example, the VTrak’s IP virtual address is 192.168.10.85. Use this address to log into WebPAM PROe.
administrator@cli> net

To log into WebPAM PROe:
Use the virtual IP address you obtained in Step 4 (see page 9). Note that the IP address shown below is only an example. The IP address you type into your browser will be different.
Together, your entry looks like this:
Together, your entry looks like this:
The User Name and Password are case sensitive.

Figure 7. WebPAM PROe log-in screen

After sign-in, the WebPAM PROe opening screen appears. You are ready to create your disk arrays and logical drives.

WebPAM PROe offers three methods of creating disk arrays and logical drives. Two of these methods are suitable for Modular Server because they can create multiple logical drives:
To create a disk array and logical drives:
If the box is unchecked, and you have both SATA and SAS drives, different arrays will be created for each type of drive.
Or check the Automatic Update box and updates will occur automatically.

The following parameters display:
If you accept these parameters, proceed to the next step.
If you do NOT accept these parameters, review and modify your selections in the previous steps.
The new disk array appears in the Disk Array List the Information tab.
To create a new disk array and logical drives:
For more information, see “Media Patrol” on page 267.
For more information, see “Predictive Data Migration (PDM)” on page 268.
You can also double-click them to move them.
Logical Drive Creation enables you to specify logical drives under the new disk array. Enter the information for a logical drive, then click the Update button. If

there is free capacity remaining, you can specify another logical drive now or wait until later.
For Modular Server, create six logical drives. Name them LD1 through LD6.
The choice of RAID levels depends the number of physical drives you selected.
For more information on axles, see “RAID 50 Axles” on page 245 or “RAID 60 Axles” on page 248.
This value will be the data capacity of the first logical drive in your new disk array. If you specify less than disk array's maximum capacity, the remainder will be available for additional logical drives which you can create later.
64 KB, 128 KB, 256 KB, and 1 MB are available. 64 KB is the default.
512 B, 1 KB, 2 KB, and 4 KB are available. 512 B is the default.
Read Cache, Read Ahead Cache, and No Cache are available. Read Ahead is the default.
Write Back and Write Through (Thru) are available. Write Back is the default.
The choices are Controller 1 or 2, or Automatic. This feature is only available on subsystems with two controllers and LUN Affinity enabled.
A new logical drive is displayed under New Logical Drives.
Repeat the above steps to specify additional logical drives as desired.
The Summary lists the disk array and logical drive information you specified.
The new disk array appears in the Disk Array List the Information tab.

A LUN represents a logical drive on the VTrak. An initiator represents a blade server in the Modular Server. Each blade server uses LUN0 for booting and storage. This task includes the following actions:
LUN masking is the process of applying a LUN Map so that each initiator can only access the LUNs specified for it. You only have to perform this action one time.
To enable the LUN Masking:
You must add an initiator to the VTrak's initiator list before you can associate the initiator with a LUN. You must repeat this action for each initiator.
To add an initiator:
A list of all currently logged-in initiators appears the screen.
The initiator is added to VTrak’s list.

A LUN map associates LUNs and initiators.
To add the LUN Map:
An initiator takes its named from the WWN of the blade server.
The blade server in slot 1 is now associated with logical drive LD1.
This action associates LUNs and initiators.
To edit the LUN Map:
Specify logical drives LD2 though LD6, in order, one logical drive for each initiator.

This action completes the association of the blade servers in slots 2 through 6 with logical drives LD2 through LD6, respectively.

In this case, the phrase installing an OS on a blade server refers to installing the OS onto the VTrak LUN assigned to the blade server.
Connections required to boot the blade server and install the OS are made through the 15-pin video connector and two USB connectors on the front panel.
This procedure requires a monitor, keyboard, mouse, and an external CD drive with a USB 2.0 interface.
To install an OS on a blade server:
Press the power button on the front panel. See Figure 8.
To power on the blade server, press the power button on the front panel. See Figure 8.
Be sure you install the OS onto LUN 0.
This completes OS installation on this blade server. Repeat the installation on your other blade servers as required.
Within Windows, you might have to bring the physical drives online to enable them.
Figure 8. Modular Server blade server

USB connectors Power button Video connector