EN
Premier Mounts logo
Official user manual

Premier Mounts UFM

20 pages·4.7 MB·Indoor Furnishings·PDF·ENDEFRITNLJA
Premier Mounts UFM
Table of Contents 13 sections INSTALLATION INSTRUCTIONS · UFM Universal Flat Mount · AUSTRALIA, NEW ZEALAND, · NORTH AMERICA EUROPE · … ShowHide
Page 1 of the Premier Mounts UFM user manual — NORTH AMERICA EUROPE
Page 1 · click to enlarge
Page 1
Premier Mounts UFM — INSTALLATION INSTRUCTIONS diagram (page 1)
Fig. 1

INSTALLATION INSTRUCTIONS

Premier Mounts UFM — INSTALLATION INSTRUCTIONS diagram (page 1)
Fig. 2
Premier Mounts UFM — INSTALLATION INSTRUCTIONS diagram (page 1)
Fig. 3

UFM Universal Flat Mount

AUSTRALIA, NEW ZEALAND,

OCEANIA (DISTRIBUTOR) 3130 East Miraloma Avenue Anaheim, CA 92806 USA

NORTH AMERICA EUROPE

Swallow House, Shilton Industrial Estate, Shilton, Coventry, England CV79JY

P.O. Box 295 Mordialloc Victoria 3195

USA and Canada – Phone800-368-9700
Australia Phone03 9586 6330 www.premiermounts.com.au
Phone+44 (0) 2476 614700
Fax800-832-4888
Fax+44 (0) 2476 614710
Other Locations – Phone001.714.632.7100; Fax: 001.714.632.1044

©Premier Mounts 2007 · 9531-001-000-01

Page 4 of the Premier Mounts UFM user manual — Flat panel list
Page 4 · click to enlarge
Page 4

Flat panel list

AcerEizoIdex PDP7859: M6 x 205420T: M8 x 30PDM4260: M4 x 16 Akai ElectrographIkegami CTA42AR7A, PDP4247, PDP4290, PDP4294, PDP5090, HPT500AN: M8 x 25 – ½” nylon spacers - sleeves DTS42W: M8 x 30 – ¼” nylon spacers (large) DTS4230: M8 x 30 – ½” nylon spacers - sleeves DTS42DD, DTS42GBDD, DTS42GB: M6 x 20PTM4202: M5 x 20 Akira FaroudjaIntegra EPM420, SV4201: M5 x 16 FPP42HD10, FPP50HD10: M4 X 16PLA50V1: M4 X 16 Albatron Fujitsu JVC PWV46AC: M6 x 20 4211, 4212, 4221, 4222, 4208, 4209, 4213, 4214, 4229, 4241 4242, 4233: M5 x 16 5001, 5002, 5003, 5004, P50XHA10, P50XCA11UH, P50XHA30WS: M8 x 25 – flat washers PDS6101, PDS6001, PDS6002: M8 x 30 – ½” Nylon spacers - sleeves BarcoGDV4200PZW, 4210, GDV4210PZWGA, 4211, GMP420UG, GMV42UG, JVP042WV74, PD42WV74, PD42WX84: M5 x 16 GDV500PZU, GDV501U, 502U: M8 X 30 – ½” nylon spacers – sleeves Cineversum 50: M8 x 20 BenQ GatewayLG Electronics PDP7843E: M6 x 20 – ¼” nylon spacers (small) PDP46W1: M6 X 12 GTWP42M102: M8 x 20, M8 x 35 – ¼” nylon spacers (large) GATEWAY 42: M8 x 30 – ¼” nylon spacers GATEWAY 46: M6 x 20 GATEWAY 50: M8 x 30 – ¼” nylon spacersFlatron MU40PA10B, MU40PA15B: M5 x 20¼” nylon spacers Flatron MN42PZ10, MN42PZ11, MU42PZ10, MU42PZ11B, MU42PZ15B: M5 x 20 MU50PZ41, MU50PZ90: M5 x 20 Flatron MU60PZ10, MU60PZ11B, MU60PZ12B, MU60PZ90V: M8 x 25 Cornea MP4200, MP4204: M5 x 16 Helios Dream VisionLuce 4200: M8 x 20 PDTV4220A: M5 x 25 – ½” nylon spacers Revolution One, Revolution Five: M4 x 16 Dukane Hitachi Marantz P37: M6 x 12 P42: M6 x 12 P50: M8 x 20 32HDT20,CMP307XJ,CMP307XU,32HDT20 CMP401HDU, CMP402HDE, CMP402HDU, CMP4120HDU,CMP4121,CMP4121HDU,CMP4201U, CMP4202U, 42HDW10,42HDT20, 42HDT50, 42HDT55 M6 x 12 CMP5000WXU, CMP5003WXU, 50HDT50, 50HDT55: M8 X 20 PD4280D, PD4282D, PD4290D, PD4292D, PD4293: M4 x 20 PD4298HD: M6 X 20 PD501OD, PD5020, PD5040: Dwin HD50: M8 x 30 – ½” nylon spacers - sleeves Max EIKI 4600, 4600T: M6 x 20 5000: M8 x 30½” nylon spacers - sleeves PLD32: M5 x 20 - ¼” nylon spacers (small) PLD42XU: M5 x 20 - ¼” nylon spacers (small)

If your flat panel display is not listed, go to (page 8) to determine the thread pitch for your flat panel.

Page 5 of the Premier Mounts UFM user manual — Flat panel list
Page 5 · click to enlarge
Page 5
MitsubishiPrinceton GraphicsTatung PD5010HD, PD5030: M4 x 16AR3.4FTW,AR4.6PDP: M6 x 20P46T: M6 x 20 MonivisionRainbowToshiba PWV46AC, PD46W00: M6 x 20Spectrum 3750: M6 x 2042HP82: M4 X 16 PD42W, PD42W1: M8 X 30 – ½ ” nylon spacers (large) - sleeves 50HP81: M8 X 30 – ½” nylon spacers (large) - sleeves 50HP82: M4 X 16 RCA NEC PR42300, PHD42600, PHD50300, PHD50400: M4 X 16 PHD50500: M8 X 20 4200W, 4210W, M4A,MP2, PX42M3A, 42PD1W, PD2 M5A,M5G, 42MP1, 42PD1, PX42VM1A, PX42VP1A, PX42VP2A, 42MP3, 42PD3, PX42VP3A, 42MP4, 42VP4A, 42MX2: M4 X 16, 5000W, PX50M5A, 50PD1, PX50VP1A, PX50MX1A, 50MP1, 50MP2, 50PD2, 50VP2, 50MP3, 50XM3: M4 X 16Tredex RevoxTXP4600: M6 x 20 V-Inc E1042: M6 x 20 E1050: M8 x 20 NorcentVizio P1, Vizio P4: M6 x 12 Runco Vidikron 46WGA850: M6 x 12 PL42C, CW42: M4 X 16 PL42CXPL50CX: M8 X 30, ½” Nylon spacers – sleeves E1050, PL50C, PL50HDX, CW50MC: M8 X 20 VPW420: M8 X 30, ½” Nylon spacers (large) - sleeves Orion VIEWSONIC PM4202: M5 x 16Sampo VPW420: M8 x 30 – ½” nylon spacers - sleeves VPW425: M8 x 30 – ¼” nylon spacers (large) VPW450HD: M8 x 30 – ¼” nylon spacers (large) VPW500: M8 X 20 VPW505: M8 x 30 – ¼” nylon spacers (large) PanasonicPME42S6: M8 x 30 – ¼” nylon spacers (large) PME42F61: M8 x 20, M8 x 35 – ¼” nylon spacers (large) PME50X6: M8 x 30 – ¼” nylon spacers (large) TC42P1, PT42PD3P, PT42PD1P, TC42P1F, PT37P1, TH42PWD3, TH37PWD4UZ, PT37PD4, TH37PW5EX, TH37PA20UP, TH42PD4UY, TH42PWD4EX, PT42P1, 42PD2, TH42PWD3U, TH42PHD5U, PT42PD3P, PT42PD4, PT42PHD4P, TH42PWD5UY, TH42PW5UZ, TH42PWD6UY, TH42PA20UP, TH42PL20E, TH42PAX20, TH50PHD3U, PT50PD3P, PT50PHD4P, TH50PHD3E, TH50PHW3, TH50PD4, TH50PHD5UY, TH50PHD6UY, TH50PL20E, TH50TX20UP: M8 X 30 – ½” Nylon spacers – sleeves TH42PX20U, TH50PX20U: M8 X 70 – 1-1/2” Nylon spacers Yamaha Samsung PDM1: M8 x 30 – ½” nylon spacers - sleeves PPM42S2, PPM42S3, SPL4225K, SPN4235, SPN4239: SPK4215M, PK42P2S: M8 x 25 – ½” nylon spacers PPM50H2, HPL5025K: M8 x 30 – ½” Nylon spacers - sleeves PPM50H3, HPN5039: M8 x 25 – ½” nylon spacers Zenith DPDP40W, P40V22,DPDP40V, P40V24: M5 x 20 – ¼” nylon spacers (small) P42W22, P42W22B, P42W24P, P42W34P: P40V24: M5 x 20 – ¼” nylon spacers (small) P50W26, P50W28, P50W38: M5 x 16 Sanyo PhilipsPDP421A: M5 x 20 - ¼” nylon spacer (small) PDP42H1NA: M5 x 20 - ¼” nylon spacer (small) If your flat panel display is not listed, go to (page 8) to determine the thread pitch for your flat panel. 42FD9934, 42FD9952, 42FD9954, 42PH9555, 42FD9935: M5 x 25 ½” Nylon spacers BDS4611: M6 x 20 50FD9934/17S: M4 X 16Sharp PZ42H2U, PZ43HV2U, PD50U, PZ50HV2U: M8 X 20 Pioneer SONY PDPV401, V402, PDP4330HD, PDP433HDE, PDP433CMX, PDP433PU, PDP4300, PDP4340HD, PRO800HD, PRO800HDI, PRO910HD, PDP4310, PDP501X, V502MX, V502X, PDP503MX, V505, PDP505HD, PRO1000HD, PDP503CMX, PDP5030HD, PDP503HDE, PDP5031HD, PDP5040HD, PRO1000HDI,PRO1110HD: M8 X 20 PFM42B1,PFM42B2: M6 x 20 - 5/16” flat washers PFM-42V1,PFM-42V2: M6 x 20– 5/16” flat washers PFM50C1: M6 x 20 - 5/16” flat washers KE-42XBR900: M5 x 20 - 5/16” flat washers KE50XBR900: M5 x 20 - 5/16” flat washers KE42XS910: M5 x 20 - 5/16” flat washers KDE61XBR950: M5 x 20 - 5/16” flat washers Planar SVA 42N: M4 x 16 50P: M8 x 20 HD4208TIII: M6 x 20 - ¼” nylon spacers
Page 6 of the Premier Mounts UFM user manual — Flat panel list
Page 6 · click to enlarge
Page 6
Premier Mounts UFM — Flat panel list diagram (page 6)
Fig. 4 · Flat panel list

This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing before beginning installation. If there are parts missing stop the installation and contact Premier Mounts.

Page 7 of the Premier Mounts UFM user manual — Nylon spacers and flat washers
Page 7 · click to enlarge
Page 7

Parts list (con’t)

Nylon spacers and flat washers

The nylon spacers may be staked to achieve proper spacing.

9/16" Nylon spacers (large)

1/2" Nylon spacers (large) Nylon sleeves

5/16" Flat washers (metal)

Show 11 more labels / short text on this page
1/4" Nylon spacers · (Qty 6) · (Qty 6) · (Qty 4) · (Qty 12) · (Qty 6) · 1" Nylon spacers · (Qty 6) · 1/4" Nylon spacers · (small) · (Qty 6)
Page 8 of the Premier Mounts UFM user manual — Parts list (con’t)
Page 8 · click to enlarge
Page 8
Premier Mounts UFM — Parts list (con’t) diagram (page 8)
Fig. 5 · Parts list (con’t)

All of these parts are used to install the mounting bracket. Make sure that none of these parts are missing before beginning installation. If there are parts missing stop the installation and contact Premier Mounts.

Premier Mounts UFM — Parts list (con’t) diagram (page 8)
Fig. 6 · Parts list (con’t)
Premier Mounts UFM — Parts list (con’t) diagram (page 8)
Fig. 7 · Parts list (con’t)
Premier Mounts UFM — Parts list (con’t) diagram (page 8)
Fig. 8 · Parts list (con’t)

5/16" x 3" Lag bolts (4) (used on wood studs

Premier Mounts UFM — Parts list (con’t) diagram (page 8)
Fig. 9 · Parts list (con’t)
Page 9 of the Premier Mounts UFM user manual — Checking the thread depth on your flat panel
Page 9 · click to enlarge
Page 9

Checking the thread depth on your flat panel

1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it. (see figure 1) 2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). If your selected screw is longer than the marking on the thread depth indicator DO NOT USE this screw. 3. The screw length must not bypass the marking. Select another screw size

(see figure 2 and 3). Until you find one that comes closest to your mark without going past.

Show 12 more labels / short text on this page
Inverted flat panel · display · Marking the depth · Thread insert · Thread depth · indicator · Screw · Marking · Thread depth indicator · Screw · Marking · Thread depth indicator
Page 10 of the Premier Mounts UFM user manual — Finding center of the flat panel display
Page 10 · click to enlarge
Page 10

Finding center of the flat panel display

Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel.

INVERT THE FLAT PANEL PLACE IT ON A SOFT, FLAT SURFACE TO PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL. DO NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO THE GLASS. THE FLAT PANEL IS HEAVY AND FRAGILE. AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL.

Premier Mounts UFM — Finding center of the flat panel display diagram (page 10)
Fig. 10 · Finding center of the flat panel display

Once the flat panel is inverted, use a measuring tape to find the center of your flat panel measuring from outside to outside of the chassis. See figure 1.

Top of flat panel

Premier Mounts UFM — Finding center of the flat panel display diagram (page 10)
Fig. 11 · Finding center of the flat panel display

Using a pencil lightly mark the center of your flat panel. See figure 2.

Mark the center of

Show 7 more labels / short text on this page
Measuring · tape · Inverted flat panel · Bottom of flat · panel · Inverted flat panel · the flat panel
Page 11 of the Premier Mounts UFM user manual — Finding center of the flat panel display
Page 11 · click to enlarge
Page 11
Premier Mounts UFM — Finding center of the flat panel display diagram (page 11)
Fig. 12 · Finding center of the flat panel display

Check the chart on page 4 and 5 to see if your flat panel needs nylon spacers. The nylon spacers provided, must be used. Failure to do so will result in damaging the flat panel.

Install the nylon spacers to the mounting points on the flat panel see figure 3.

See chart (if the nylon spacers apply to your flat panel).

Lay the left and right mounting brackets (stamped arrows facing out). See figure 4.

Page 12 of the Premier Mounts UFM user manual — Finding center of the flat panel display
Page 12 · click to enlarge
Page 12
Premier Mounts UFM — Finding center of the flat panel display diagram (page 12)
Fig. 13 · Finding center of the flat panel display

Match the center of viewing guide with the center line you marked in step 1. See figure 5.

The mounting brackets are designed with a center of viewing guide on the side of them. See figure 6.

Page 13 of the Premier Mounts UFM user manual — Securing the mounting brackets
Page 13 · click to enlarge
Page 13

Securing the mounting brackets

Premier Mounts UFM — Securing the mounting brackets diagram (page 13)
Fig. 14 · Securing the mounting brackets

The Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires.

EXAMPLE: If your plasma uses M8 x 20 Phillip screws. Use the M8 mounting points. See figure 7

Once the mounting brackets are aligned secure the Griplate™ to the flat panel.

The dimples of the top plates have to be facing up and the bottom dimples must be facing down. Use (1) Griplate™ per mounting point. See figure 8.

Leave a ¾” gap on both mounting brackets as shown on this diagram.

Page 14 of the Premier Mounts UFM user manual — Securing the mounting brackets
Page 14 · click to enlarge
Page 14
Premier Mounts UFM — Securing the mounting brackets diagram (page 14)
Fig. 15 · Securing the mounting brackets

Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall. Once found, make a pencil marking on the center of the wood studs. See figure 9.

The wall plates have (3) 16" and (1) 24" mounting slot positions. (Look at the assembly drawing on page 3)

Measure from the floor to the desired viewing height and mark the wall. See figure 10.

Measure and mark the viewing height desired on the wall

This marking will reference the center of your flat panel display once mounted on the wall.

Page 15 of the Premier Mounts UFM user manual — Securing the mounting brackets
Page 15 · click to enlarge
Page 15
Premier Mounts UFM — Securing the mounting brackets diagram (page 15)
Fig. 16 · Securing the mounting brackets

Place the bottom portion of the wall plate to the reference line and mark the four (4) lag bolt mounting points through the wall plate slots on the wall. Level the wall plate with the reference arrow pointing up to the ceiling. See figure 11.

Wood studs: Drill four (4) ¼" pilot holes to the marked wall. Concrete wall: Drill four (4) 3/8” pilot holes to the marked wall. See figure 12.

Page 16 of the Premier Mounts UFM user manual — Securing the mounting brackets
Page 16 · click to enlarge
Page 16
Premier Mounts UFM — Securing the mounting brackets diagram (page 16)
Fig. 17 · Securing the mounting brackets

Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Secure the plate using the four (4) 5/16" lag bolts and flat washers (supplied). See figure 13.

Use a minimum diameter of 5/16” x 3” long wood screws.

(4) 5/16" x 3" lag bolts and (4) flat washers

Page 17 of the Premier Mounts UFM user manual — Securing the mounting brackets
Page 17 · click to enlarge
Page 17
Premier Mounts UFM — Securing the mounting brackets diagram (page 17)
Fig. 18 · Securing the mounting brackets

Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Use a min dia of 5/16” x 2 ¼” lg concrete wedge anchors (commercially available). See figure 14.

Use a minimum diameter of 5/16” x 2 ¼” long wedge anchors (commercially available).

Premier Mounts UFM — Securing the mounting brackets diagram (page 17)
Fig. 19 · Securing the mounting brackets
Page 18 of the Premier Mounts UFM user manual — Securing the mounting brackets
Page 18 · click to enlarge
Page 18
Premier Mounts UFM — Securing the mounting brackets diagram (page 18)
Fig. 20 · Securing the mounting brackets

AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL.

Raise the flat panel with the LEFT and RIGHT mounting brackets secured to the flat panel and insert the top hooks from each bracket to the rod from the wall plates. See figure 15.

Premier Mounts UFM — Securing the mounting brackets diagram (page 18)
Fig. 21 · Securing the mounting brackets
Page 19 of the Premier Mounts UFM user manual — Securing the mounting brackets
Page 19 · click to enlarge
Page 19
Premier Mounts UFM — Securing the mounting brackets diagram (page 19)
Fig. 22 · Securing the mounting brackets

Make any lateral shift adjustment and lock it by tightening the two (2) ¼”-20 Phillips screws found on the bottom of the mounting brackets. Use the foot leveler to adjust your plasma. See figure 16

Do not over tighten the ¼”-20 screws to the rods.

To remove the display from the wall simply back off the ¼”-20 screws using a Phillips screwdriver and lift the unit of the wall carefully.

Page 20 of the Premier Mounts UFM user manual — Warranty
Page 20 · click to enlarge
Page 20

Warranty

PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original installation of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defective. If Premier Mounts chooses to replace a defective product or part, a replacement product or part will be shipped to you at no charge, but you must pay any labor costs. What is Not Covered; Limitations PREMIER MOUNTS DISCLAIMS ANY LIABILITY FOR DAMAGE TO MOUNTS, ADAPTERS, DISPLAYS, PROJECTORS, OTHER PROPERTY, OR PERSONAL INJURY RESULTING, IN WHOLE OR IN PART, FROM IMPROPER INSTALLATION, MODIFICATION, USE OR MISUSE OF ITS PRODUCTS.

PREMIER MOUNTS DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO, INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOVING AND REPLACING DEFECTIVE PRODUCTS OR PARTS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.

What Customers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the address below within thirty (30) days. Proof of purchase (an original sales receipt) from the original consumer purchaser must accompany all warranty claims. Warranty claims must also include a description of the problem, the purchaser’s name, address, and telephone number. General inquiries can be addressed to Premier Mounts Customer Service at 1-800-368-9700. Warranty claims will not be accepted over the phone or by fax. Premier Mounts Attn: Warranty Claim 3130 E. Miraloma Avenue Anaheim, CA 92806 How State Law Applies

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.

Ask about the Premier Mounts UFM

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Premier Mounts UFM

Be the first to ask — other owners or our team will answer.

Original document

Premier Mounts UFM manual PDF

20 pages·4.7 MB·Indoor Furnishings·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…