Instruction/ maintenance manual of the product DE5450 PowerMax
Go to page of 16
DE5450 1 PO WERMAX PO WERMAX PO WERMAX PO WERMAX Fully Supervised Wireless A larm Control Sy stem Installation Instructions TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS 1. INTRODUCTION .......................................
2 DE5450 1 1 1 1. INTRODUCTION . INTRODUCTION . INTRODUCTION . INTRODUCTION The PowerMax is a user and installer-friendly, 30-zone fully-supervised wireless control panel.
DE5450 3 Sounder Output Current w ith 1A transformer Internal sounder: 50 mA max . External sounder: 350 mA max. Attention! The 350 mA rating is valid only for units with a sticker th at says “ Option: 9VAC / 1A plug-in transformer” Fuse Ratings: 1A for battery protection (in U.
4 DE5450 D . Remove the screw that secures the lid (see Figure 3), swing the lid up and pull it away. You now have acces s to the battery holder (see Figure 4). E . Pull out the battery holder and check that the battery type selection j umper is positioned in accordance with the type of batteries being installed (see Figure 4).
DE5450 5 panel from the bracket will start a tam per alarm. Forcibly remov ing the entire assembly off the wall will also start a tamper alarm, because the joints of the ring and cam piece to the bracket leg will break off, leaving the ring and cam attached to the wall.
6 DE5450 You will need the following telephone-type cords: • For telephone line hookup only (installations w here line seizure is not required): 6-lead RJ-11 cord(s ). • For telephone line-and-set hookup (typical installation requiring line seizure): 8-lead RJ-31X cord(s ).
DE5450 7 is capable of “learning” each detector’s identification code and linking it to a specif ic zone (see Section 3 in the Programming M anual). Some units are shown below: Figure 14. MC PIR-2000 Figure 15. MC PIR-3000 or K-940 MCW Figure 16.
8 DE5450 RS232 module to an already installed PowerMax system : A. Detach the cabinet from the bracket (see Para. 5.1) B. Remove the factory installed plastic cap by sliding it out along the grooves as shown in Figure 27. Figure 27. Removing the Cap from the RS232 Niche C.
DE5450 9 indicator should extinguish, the “Happy Tune” (- - - –––) should sound and the display should revert to: READY HH:MM Test the AU X button in each k eyfob in accordance with the information noted in Table A.2, Appendix A. Verif y that the AUX button perf orms its duty as programmed.
10 DE5450 5.2 Replacing t he Backup Battery CAUTION! If you replace rechargeable cells with alkaline (dry) cells, be sure to install the battery-type jumper in the “DRY” position. Failure to do so will re sult in rapid cell destruction and leakage (acid leak age may cause further damage).
DE5450 11 Indicate the desired function (if any) - see Para. 5.16 in the programming guide. APPENDIX A. Detector Deployment & Transmitter Assignments A1. Detector Deployment Plan Zone No. Zone Ty pe Sensor Location or Transmitter Assignment (in non-alarm or emergency zones) Chime (Yes / No) Controls PGM (X = YES) Controls X-10 Unit No.
12 DE5450 A3. Emergency Tr ansmitter List Tx # Transmitter T y pe Enrolled to Zone Name of holder 1 2 3 4 5 6 7 8 9 10 A4. Non-Alar m Transmitter List Tx # Transmitter T y pe Enrolled to Zone Name of holder Assignment 1 2 3 4 5 6 7 8 9 10 APPENDIX B. X-10 Unit Assignments Unit Controlled ON ON ON ON ON by Timer ON by Zone No.
DE5450 13 Federal Communications Commission (FCC) Statements FCC PA RT 15 ST A TEM ENT This device complies w ith Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) Th.
14 DE5450.
DE5450 15 NOTES:.
16 DE5450 WARRANTY Visoni c Ltd. and/or its subsi diaries and i ts affiliates ("the Manufacturer") warrants i ts products herei nafter referred to as "the Product" or "Product.
An important point after buying a device PowerMax DE5450 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought PowerMax DE5450 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data PowerMax DE5450 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, PowerMax DE5450 you will learn all the available features of the product, as well as information on its operation. The information that you get PowerMax DE5450 will certainly help you make a decision on the purchase.
If you already are a holder of PowerMax DE5450, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime PowerMax DE5450.
However, one of the most important roles played by the user manual is to help in solving problems with PowerMax DE5450. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device PowerMax DE5450 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center