Instruction manual The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for futur e refer ence. Model No. ______________________________________ T ype ___________________________________________ Serial No.
2 GENERAL SAFETY RULES ELECTRICAL SAFETY 1. Use battery operated rotary level with alkaline batteries only . Use of any other batteries may permanently damage the rotary level. PERSONAL SAFETY 1. Stay alert, watch what you are doing, and use common sense when operating a laser .
3 FUNCTIONAL DESCRIPTION FOREWORD Porter -Cable Model LR 1100 Rotary Level is a self-leveling, remote-contr olled, precision laser level of superior quality that is time-saving and easy to use. Place it on any surface and the perfectly balanced, self-leveling pendulum inside the device takes care of the r est.
4 OPERA TION Quick Guide to Using Rotary Level The One Minute Set-Up 1. Set the Base Unit up on a tripod or any surface that is within 10° of level. There are two tripod mounts built into the bottom of the Adjusting Base - a 5/8" x 11 (standard transit level tripod) and 1/4" x 20 (camera-type tripod).
5 Using the Remote Control The Remote Control is one of the features that makes Rotary Level unique in the field of laser leveling systems. Using the Remote Control, you can control the rotation of th.
6 Battery replacement Base Unit - 4 "AA" Alkaline Batteries 1. Unscrew the battery housing cover using either your fingers or a coin. Lift the cover off. 2. Insert the new batteries according to the illustrations on the battery slots. 3. Replace the battery housing cover and tighten the screw secur ely .
7 Recalibration Rotary Level can be recalibrated by you, in the field. If Rotar y Level is dropped, you should recalibrate. 1. Choose your recalibration site. T o get the most accurate calibration possible, it is best to use two vertical (plumb) surfaces directly opposite each other , 100' apart (50' minimum).
8 8. Move the base unit to about 5' from Surface B (the location you just marked). Raise or lower the Base Unit so that the laser dot hits the spot you have already marked. 9. Using the Remote Control, r otate the Base Unit until the laser dot is exactly on, directly above, or dir ectly below the point marked on Surface A.
9 T roubleshooting When the… LED does not come on when Lens Cover is up. LED and Laser blink continuously . Remote Control will not drive the Base Unit. Laser & LED shut off without warning blinks. Base Unit will not move on Adjusting Base. The batteries in the Base Unit may need to be changed.
10 Line Generating Feature Y ou have just purchased your Self-Leveling, Remote Controlled Laser , Rotary Level with the new line-generating feature. The following outlines the operation of the feature with your Rotary Level.
11 - Reorient or relocate the r eceiving antenna - Increase the separation between the equipment and r eceiver - Consult the dealer or an experienced radio/TV technician for help.
12 REPLACEMENT P ARTS LIST 905898 ANTENNA 905899 REMOTE CONTROL 905900 REMOTE CONTROL BA TTERY COVER 905901 BA TTERY COVER SCREW 905907 BA TTERY COVER 905972 CALIBRA TION PORT PLUG ACCESSORIES A compl.
The following are trademarks of PORTER-CABLE • DEL T A (Las siguientes son marcas registradas de PORTER-CABLE • DEL T A S.A.) (Les marques suivantes sont des marques de fabriquant de la POR TER-CA.
An important point after buying a device Porter-Cable LR1100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Porter-Cable LR1100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Porter-Cable LR1100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Porter-Cable LR1100 you will learn all the available features of the product, as well as information on its operation. The information that you get Porter-Cable LR1100 will certainly help you make a decision on the purchase.
If you already are a holder of Porter-Cable LR1100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Porter-Cable LR1100.
However, one of the most important roles played by the user manual is to help in solving problems with Porter-Cable LR1100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Porter-Cable LR1100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center