Oilfr ee Portable Air Compr essor Instruction manual IMPORT ANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. Part No. A01787-0312-0 ESP AÑOL: PÁGINA 25 FRANÇAIS: P AGE 49 T o lear n more about Porter -Cable visit our website at: http://www .
2- ENG A01787 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
3- ENG A01787 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
4- ENG A01787 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG A01787 WARNING: Risk to Br eathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is power ed by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
6- ENG A01787 WARNING: Risk of Burns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will r emain hot for several minutes after operation.
7- ENG A01787 Review and understand all instructions and warnings in this manual. Become familiar with the operation and controls of the air compr essor . Keep operating area clear of all persons, pets, and obstacles. Keep children away fr om the air compressor at all times .
8- ENG A01787 GLOSSAR Y Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressur e.
9- ENG A01787 INST ALLA TION HOW TO SET UP YOUR UNIT GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, gr ounding reduces the risk of shock by pr oviding an escape wire for the electric curr ent. This air compressor must be properly gr ounded.
10- ENG A01787 Extension Cords Using extension cords is not r ecommended. The use of extension cords will cause voltage to drop r esulting in power loss to the motor and overheating. Instead of using an extension cord, incr ease the working reach of the air hose by attaching another length of hose to its end.
11- ENG A01787 Description of Operation Become familiar with these controls befor e operating the unit. On/Auto/Off Switch (A) : T ur n this switch ON to provide automatic power to the pressur e switch and OFF to remove power at the end of each use.
12- ENG A01787 Cooling System (not shown) : This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in lar ge amounts.
Before Starting Break-in instructions Serious damage may result if the following br eak-in instructions are not closely followed. This procedur e is requir ed before the air compr essor is put into service and when the check valve or a complete compressor pump has been r eplaced.
How to Use Remote Console: When needed the remote console allows r emote air regulation and control closer to the work ar ea. Reduce air pressur e in tank to 60 psi maximum before removing or connecting portable contr ol panel and when connecting hose to tank quick-connect coupler .
15- ENG A01787 How to transport unit The unit has a handle (a) for carrying and a handle (b) for pulling. 1. Grasp carrying handle (a) to lift unit. 2. Slide handle (b) out until it locks into place. 3. Pull unit as shown, do not push unit. NOTE: When transporting do not lift the unit to the point where it would tip over backwar ds.
16- ENG A01787 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● Y early ● 1 1- more fr equent in dusty or humid conditions Check Safety V alve Drain T ank Air Filter NOTE: See "Operation" section for the location of controls.
17- ENG A01787 Air Compressor Pump Intake and Exhaust V alves Once a year have a T rained Service T echnician check the air compressor pump intake and exhaust valves. Air Filter Inspection and Replacement Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed.
18- ENG A01787 T o Replace or Clean Check V alve 1. Release all air pressur e from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. NOTE: If needed the top panel may be removed to make parts accessible. 3. Using an adjustable wrench loosen outlet tube nut at air tank and pump.
19- ENG A01787 STORAGE Before you stor e the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to "OFF".
20- ENG A01787 TROUBLESHOOTING Performing repairs may expose voltage sour ces, moving parts or compressed air sour ces, moving parts or compressed air sour ces. Personal injury may occur . Prior to attempting any repairs, unplug the air compr essor and bleed off all air tank air pressur e.
21- ENG A01787 PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section.
22- ENG A01787 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit br eaker tripped.
23- ENG A01787 NOTES.
24- ENG A01787 LIMITED W ARRANTY PORTER-CABLE CORPORA TION warrants to the original purchaser that all products cover ed under this warranty are fr ee from defects in material and workmanship.
An important point after buying a device Porter-Cable JOB BOSS CFFC350B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Porter-Cable JOB BOSS CFFC350B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Porter-Cable JOB BOSS CFFC350B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Porter-Cable JOB BOSS CFFC350B you will learn all the available features of the product, as well as information on its operation. The information that you get Porter-Cable JOB BOSS CFFC350B will certainly help you make a decision on the purchase.
If you already are a holder of Porter-Cable JOB BOSS CFFC350B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Porter-Cable JOB BOSS CFFC350B.
However, one of the most important roles played by the user manual is to help in solving problems with Porter-Cable JOB BOSS CFFC350B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Porter-Cable JOB BOSS CFFC350B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center