Instruction/ maintenance manual of the product 1725-361300-001 Polycom
Go to page of 21
July 2008 Edition 1725-36130-001 Version E Avaya DEFINITY Communications System LinkPlus Interface Guide SpectraLink 6000 System SpectraLink 8000 System.
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 2 Trademark Information Polycom® and t he logo design s SpectraLink® LinkPlus Link NetLink SVP Are trademarks and registe red trademarks of Polycom, Inc. in the Un ited States of Am erica and various c ountries.
PN: 1725-36130-001_E.doc 3 About this Guide Polycom is the market leader in multi-cellular wireless telephone systems for the workplace. We manufacture a range of products to suit any size installation. All Polycom products use our Lin kPlus digital integration technology to inte grate with various digital switch platforms.
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 4 Related Documents SpectraLink 6300 MCU : Operator’s Console (1725-36125-001) SpectraLink 6100 MCU: Installation and Operation (1725-36097-001) SpectraLink 6020 Wireless Telephone and Accessories User Guide (1725-36092-001) Available at http://www.
About this Guide PN: 1725-36130-001_E.doc 5 Icons and Conventions This manual uses the following icons and conventions. Caution! Follow these instructions carefully to avoid danger. Note these instructions carefully. Label This typeface indicates a key, label, or button on SpectraLink hardware.
.
PN: 1725-36130-001_E.doc 7 Plan the Interface The system administrator programs the telephone system for use with the Wireless Telephone System using the normal administration terminal or procedures. Programmi ng can be done after the hands ets are registered.
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 8 “model” handsets then use the mod el as a template to program the other handsets. • All handsets are different : All handsets are programmed differently, so each handset will be programmed individually.
Plan the Interface PN: 1725-36130-001_E.doc 9 It will help to identify a wired set that is programmed exactly or close to the way the handsets should be programmed.
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 10 When lines are programmed as shown on the k ey-map diagrams, the numeral icons on the handset display will be mapped to any deskset LEDs associated with the corresponding feature keys.
Plan the Interface PN: 1725-36130-001_E.doc 11 Function Menu Programming SpectraLink 6300 MCU Note that the function menu defaults set for the handset s associated with the SpectraLink 6300 MCU can be changed via the SpectraLink Operator’s Console.
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 12 Hold The Hold feature should be programmed to the HOLD key as shown on the Key-map Diagrams so that when t he HOLD key or softkey is pressed on the handset, the call is placed on hol d.
PN: 1725-36130-001_E.doc 13 Interface Implementation This section describes the recommended programming to use the SpectraLink 6000 System with a DEFINITY Communications System. The procedures assume: • The DEFINITY system is installed and operational in an ap proved configuration.
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 14 DEFINITY Four-Wire Interface The DEFINITY TN754B (any vintage) or TN754 (vintage 11 or higher) circuit pack provides eight, four-wir e digital station circuits.
Interface Implementation PN: 1725-36130-001_E.doc 15 See the documentation for your SpectraLink components for more information about wiring the dema rc block or patch panel. The following table shows the patch cord pinout for the Avaya side of the modular 8-pin (RJ45) connector.
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 16 Key-mapping the Handset to Emulate 8410D Functionality Programmable buttons on Page 2 of the station fo rm can be assigned as determined in the pre-installa tion procedures.
Interface Implementation PN: 1725-36130-001_E.doc 1 7 is the sequence equivalent to pre ssing the corresponding softkey on the desk set. The handset function menu default settings are shown on e ach corresponding button in the above diagram; these may be changed as described above in Function Menu Programming .
LinkPlus Interface Guide: Avaya DEFINITY Communications System PN: 1725-36130-001_E.doc 18 settings so they can be manually duplicated using an add s tation command for the template handset. Station features for handset Station features on Page 1 of the sta tion form can be assigned or copied as determined in the pr e-installation procedures.
Interface Implementation PN: 1725-36130-001_E.doc 19 • To make the handset ring when the wired station rings, cha nge Bridged Call Alerting to Yes on the wired station. If the handset is not a bridged appear ance of a wired station, assign buttons 1-3 as call appearances (call-appr).
.
PN: 1725-36130-001_E.doc 21 Extension Assignments Worksheet Shelf: _______ Interface Module: _______ Handset # Ext. # Name Interface Module Circuit # Comment Handset Serial # Handset 1 1 Handset 2 2 H.
An important point after buying a device Polycom 1725-361300-001 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Polycom 1725-361300-001 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Polycom 1725-361300-001 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Polycom 1725-361300-001 you will learn all the available features of the product, as well as information on its operation. The information that you get Polycom 1725-361300-001 will certainly help you make a decision on the purchase.
If you already are a holder of Polycom 1725-361300-001, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Polycom 1725-361300-001.
However, one of the most important roles played by the user manual is to help in solving problems with Polycom 1725-361300-001. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Polycom 1725-361300-001 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center