Instruction/ maintenance manual of the product WGSD-1020 Planet Technology
Go to page of 93
10/100/1000Mbps Intelligent Gigabit / Fast Ethernet S w itch WGSD-1020 User ’ s Manual.
Trademarks Cop y right PLANE T T echnolog y Corp. 2003. Contents subject to revision w ithout prior notice. PLANE T is a registered trade m ar k o f PLANE T T echnolog y Corp.
T A BLE OF CON T EN T S 1. IN T RODUC T IO N ...................................................................................................................................... .1 1.1 C HECKLIST .....................................................
A PPENDIX A NE T WORKING CONNEC T IO N ............................................................................................ . 86 A.1 S W ITCH ‘ S RJ-45 P IN A SSIGNMENTS .......................................................................
- 1 - 1. INTRODUCTION 1.1 Checklist Check the contents of y our package for follo w ing parts: ● W GSD-1020 ● User's m anual CD ● RS-232 cable ● Po w er cord ● Quic k installation Guide.
- 2 - ◆ Support IGMP V1.0 ◆ Support LACP IEEE 802.3ad Port T run k ing ◆ Support MAC address f iltering ◆ Co m plies w ith IEEE 802.1d Spanning T ree ◆ Support port sni ff er f unction ◆ S.
- 3 - 2. H A RDW A RE DESCRIPTION T his section describes the hard w are f eatures o f the Giga S w itch. For easier m anage m ent and control o f the s w itch, f a m iliari z e y oursel f w ith its displa y indicators, and ports. Front panel illustrations in this chapter displa y the unit LED indicators.
- 4 - 1000Base- T LNK/ A C T 1000/100 FDX 2.2 Rear Panel T he rear panel o f the S w itch indicates an AC inlet po w er soc k et, w hich accepts input po w er f ro m 100 to 240VAC, 50-60H z . 100 - 240V AC 50/60 Hz 9600, N , 8, 1 C on s o le Figure 2: WGSD-1020 S w itch rear panel Po w er Notice: 1.
- 5 - 2.3 Hard w are Installation 2.3.1 Before start up Be f ore y our installation, please re f er to the f ollo w ings f or y our cabling: 100Base- T X All 100Base- T X ports co m e w ith auto-negotiation capabilit y . T he y auto m aticall y support 100Base- T X and 10Base- T net w or k s.
- 6 - Figure 3. End node or Hub or S w itch connection Notice: Cable distance for S w itch T he cable distance bet w een Ethernet S w itch and hub/PC should not exceed 100 m eter f or U T P/S T P cable. M ake sure the w iring is correct It can be used Categor y 3/4/5 cable in 10 Mbps operation.
- 7 - 3. SWITCH M A N A GE M ENT T his chapter describes ho w to m anage the S w itch. T opics include: - Overvie w - Manage m ent m ethods - Assigning an IP address to the S w itch - Logging on to the S w itch 3.1 O v er v ie w T he S w itch provides a user- f riendl y , m enu driven console inter f ace.
- 8 - 3.2.2 Remote Console Management Y ou can m anage the S w itch re m otel y b y having a re m ote host establish a T elnet connection to the S w itch via an Ethernet or m ode m lin k .
- 9 - 4. CONSOLE INTERF A CE 4.1 CONNECT TO PC RS-232 serial cable Use the bundled RS-232 serial cable and attach the 9-pin f e m ale connector to the m ale connector on the s w itch.
- 10 - 4.2 Login in Login is required to access the co mm and console a f ter the sel f -test co m pletes success f ull y . T he f actor y de f ault user na m e is " admin " w ithout pass w ord. Y ou m a y change it in the S y ste m Menu. T o access to the Main Menu, please al w a y s enter the correct user na m e.
- 11 - 4.3.1 Status and Counters Fro m the S w itch m ain m enu screen (see Figure 4-3) , highlight Status and counters and press enter. T he Status and Counters sub-screen in Figure 4-4 appears. Figure 4-4 Status and Counters sub-screen T his sub- m enu contains f our ite m s: Port Status: Please re f er to chapter 4.
- 12 - 4.3.1.2 Port Counters Displa y the tra ff ic counters o f each port on W GSD-1020. Figure 4-6 Port Counters screen 4.3.1.3 S y stem Information Displa y the S w itch in f or m ation.
- 13 - 4.3.2 S w itch Static Configuration Fro m the S w itch Static Con f iguration screen (see Figure 4-8) , highlight S w itch Static Con f iguration and press Enter.
- 14 - 4.3.2.1 A dministration Configuration Figure 4-10 Device Con f iguration screen T his sub- m enu contains f ive ite m s: De v ice Information: please re f er to chapter 4.3.2.1.1 IP Configuration: please re f er to chapter 4.3.2.1.2 Change Username: please re f er to chapter 4.
- 15 - 4.3.2.1.2 IP Configuration Press ” Edit ” to m odi f y the IP address, Subnet Mas k and Gate w a y . Figure 4-12 IP Con f iguration screen Press “ T ab ” to m ove the cursor to IP Address, Subnet Mas k and Gate w a y to input ne w value.
- 16 - 4.3.2.1.3 Change Username Press “ Edit ” to input the ne w userna m e and choose “ sa ve ” to save the current con f iguration. T he f ollo w ing screen in Figure 4-14 appears.
- 17 - 4.3.2.1.4 Change Pass w ord Allo w user to m odi f y the pass w ord. Figure 4-16 Pass w ord Con f iguration screen M odif y the pass w ord procedure: 1. Enter old pass w ord: e m pt y (De f ault is no pass w ord) 2. Enter ne w pass w ord: * * * ( Ne w pass w ord 123) 3.
- 18 - 4.3.2.2 Port & T runking Configuration Fro m the S w itch Static Con f iguration sub-screen (see Figure 4-9) , highlight Port T run k Con f iguration and press enter.
- 19 - Figure 4-19 Port & T run k ing Con f iguration save success f ull y screen 4.3.2.3 Port Sniffer Configuration Fro m the S w itch Static Con f iguration sub-screen (see Figure 4-9) , highlight Port Sni ff er Con f iguration and press enter. T he Port Sni ff er Con f iguration screen in Figure 4-20 appears.
- 20 - 4.3.2.4 VL A N Configuration Fro m the S w itch Static Con f iguration sub-screen (see Figure 4-9) , highlight VLAN Con f iguration and press enter. T he VLAN Con f iguration screen in Figure 4-21 appears. Figure 4-21 VLAN Con f iguration screen T his sub- m enu contains f our ite m s: VL A N Configure: please re f er to chapter 4.
- 21 - . Figure 4-23 IEEE 802.1Q VLAN Con f iguration screen Press space bar s w itch to 802.1Q w ith GVRP in VLAN m ode. T he screen in Figure4-24 appears. Figure 4-24 IEEE 802.1Q VLAN w ith GVRP screen Press space bar s w itch to Port-based VL AN in VLAN m ode.
- 22 - Figure 4-25 Port-based VLAN screen 4.3.2.4.2 Create a VL A N Group T o add a VLAN group, the VLAN ID range is 1-4094. Figure 4-26 Add a VLAN Group screen A dd a VL A N Group procedure: 1. Press “ Edit ” to input the VLAN na m e and VLAN ID.
- 23 - 4.3.2.4.3 Edit / Delete VL A N Group Allo w editing and deleting VLAN GROUP. Figure 4-27 Edit a VLAN Group screen 4.3.2.5 Priorit y Configuration Displa y s the options available f or assigning High and Low priorit y to each port.
- 24 - Figure 4-29 Priorit y Con f iguration save success f ull y screen Press an y k e y return to the previous m enu. 4.3.2.6 M A C A ddress Configuration Provide static MAC address and Filtering MAC address and previous Menu.
- 25 - 4.3.2.6.1 Static M A C A ddress Figure 4-31 Static MAC Address Con f iguration screen Press, “ A dd ” to add a static MAC address, a f ter setup co m pleted, press “ Ctrl-A ” and choose “ Sa ve ” to save the current con f iguration.
- 26 - 4.3.2.6.2 Filtering M A C A ddress Figure 4-33 Filter MAC Address Con f iguration screen Press “ A dd ” to add a Filter MAC address, a f ter setup co m pleted, press “ Ctrl-A ” and choose “ Sa ve ” to save the current con f iguration.
- 27 - 4.3.2.7 M isc Configuration Fro m the S w itch Static Con f iguration sub-screen (see Figure 4-9) , highlight Misc Con f iguration and press enter. T he Misc Con f iguration sub-screen in Figure 4-35 appears. Figure 4-35 Misc Con f iguration screen T his sub- m enu contains f ive ite m s: Port Securit y: please re f er to chapter 3.
- 28 - 4.3.2.7.2 M A C A ge Inter v al Allo w to setting the aging ti m e o f W GSD-1020. T he m axi m u m value is 765 sec. Figure 4-37 Aging T i m e Con f iguration screen Press “ Edit ” to input the aging ti m e value and press enter to choose the “ sa ve ” f or save the current con f iguration.
- 29 - 4.3.2.7.3 Broadcast Storm Filtering Provide disable and 5, 10, 15, 20 or 25 Broadcast stor m f ilter m ode. Figure 4-39 Broadcast stor m f ilter screen Broadcast Storm Filter setup procedure: 1. Press “ Edit ” to input 5, 10, 15, 20 or 25 broadcast stor m f ilter.
- 30 - 4.3.2.7.4.1 M ax bridge transmit dela y bound Provide “ OFF ” and 1, 2, or 4 sec. f or selection. Figure 4-41 Max Bridge trans m it dela y bound screen Setup procedure: 1.
- 31 - 4.3.2.7.4.2 Enable Dela y Bound Provide disable or enable Dela y Bound f unction. Figure 4-43 Enable Dela y Bound screen Setup procedure: 1. Choose disable or enable through the space bar. 2. A f ter setup co m pleted, press ” Ctrl-A ” to “ A ction menu ” and choose “ sa ve ” to save the current con f igure.
- 32 - 4.3.2.7.4.3 M ax Dela y T ime Allo w inputting the Max Dela y T i m e. Figure 4-45 Max Dela y T i m e screen Setup procedure: 1. Press “ Edit ” to input the Max Dela y T i m e value. 2. A f ter setup co m pleted, press ” Ctrl-A ” to “ A ction menu ” and choose “ sa ve ” to save the current con f igure.
- 33 - 4.3.3 Protocol Related Configuration Fro m the S w itch m ain m enu screen (see Figure 4-3) , highlight Protocol Related Con f iguration and press enter.
- 34 - T his sub- m enu contains f our ite m s: S T P Enable: please re f er to chapter 4.3.3.1.1 S y stem Configuration: please re f er to chapter 4.3.3.1.2 Per port Configuration: please re f er to chapter 4.3.3.1.3 Pre v ious M enu: return to previous m enu.
- 35 - 4.3.3.1.2 S y stem Configuration Allo w m odi f y the S T P s y ste m con f iguration. Figure 4-51 S T P s y ste m con f iguration screen Setup procedure: 1.
- 36 - 4.3.3.1.3 Per Port Configuration Allo w edit per port S T P con f iguration. Figure 4-53 S T P Port con f iguration screen Setup procedure: 1. Press “ Edit ” to m odi f y the path cost and priorit y o f each port.
- 37 - 4.3.3.2 SN M P Provide SNMP con f iguration. Figure 4-55 SNMP con f iguration screen T his subnet m enu contains f our ite m s: 1. S y stem Options: please re f er to chapter 4.3.3.2.1 2. Communit y Strings: please re f er to chapter 4.3.3.2.2 3.
- 38 - Setup procedure: 1. Press “ Edit ” to input the s y ste m na m e, s y ste m contact, s y ste m location. 2. A f ter setup co m pleted, press ” Ctrl-A ” to “ A ction menu ” and choose “ sa ve ” to save the current con f igure. T he screen in Figure 4-57 appears.
- 39 - Figure 4-59 Add SNMP Co mm unit y na m e save success f ull y screen 3. Press an y k e y f or return to the previous m enu. 4.3.3.2.3 T rap M anagers Allo w adding T rap Managers. Figure 4-60 Add SNMP Co mm unit y na m e screen Setup procedure: 1.
- 40 - Figure 4-61 Add T rap m anagers screen 3. Press an y k e y f or return to the previous m enu. 4.3.3.2.4 Pre v ious M enu Return to the previous m enu. 4.3.3.3 GVRP Provide disable or enable GVRP f unction Figure 4-62 GVRP screen Setup procedure: 1.
- 41 - Figure 4-63 GVRP save success f ull y screen 3. Press an y k e y f or return to the previous m enu. 4.3.3.4 L A CP Figure 4-64 LACP Con f iguration screen T his subnet m enu contains f our ite m s: 1. A ggregator Settings: please re f er to chapter 4.
- 42 - 4.3.3.4.1 A ggregator Settings Allo w editing the LACP Group con f iguration. Figure 4-65 Aggregator settings screen 4.3.3.4.2 State A cti v it y Allo w to set LACP port state activit y o f each port. Figure 4-66 LACP port state Active con f iguration screen Setup procedure: 1.
- 43 - Figure 4-67 LACP port state Active con f iguration screen 3. Press an y k e y f or return to the previous m enu. 4.3.3.4.3 L A CP Status Displa y the LACP groups status. Figure 4-68 LACP Group Status screen 4.3.3.4.4 Pre v ious M enu Return to the previous m enu.
- 44 - 4.3.4 Reboot S w itch Provide reboot the S w itch and reset to s w itch to de f ault m ode. Figure 4-69 Reboot S w itch screen T his subnet m enu contains three ite m s: 1. Default: please re f er to chapter 4.3.4.1. 2. Restart: please re f er to chapter 4.
- 45 - Figure 4-71 Resetting S w itch screen 4.3.4.2 Restart Provide restart the S w itch. T he screen in Figure 4-72 appears. Figure 4-72 Restart S w itch screen 4.
- 46 - 4.3.5 Command Line Provide s y ste m co mm and f or W GSD-1020. T he screen in Figure 4-73 appears. Figure 4-73 Co mm and line screen T y pe “ Help ” co mm and f or helps para m eters. T he screen in Figure 4-74 appears. Figure 4-74 Help para m eters screen 4.
- 47 - 5. WEB M A N A GE M ENT Be f ore login the W eb inter f ace o f W GSD-1020, please setup the “ IP A ddress ” w ith local serial console port( RS232 port) and use this IP address to con f igure W GSD-1020 through the T elnet and Web inter f ace.
- 48 - 5.2 Port Status T his section provides detail status o f each port f ro m W GSD-1020. Figure 5-3 W GSD-1020 Port Status W eb Page screen State: displa y the lin k state o f each port on W GSD-1020. Link Status: the state o f the lin k test, indicating a valid lin k partner device.
- 49 - 5-3 Port Statistics For those selected port, this f unction could provide y ou w ith an individual statistical counter. It is a use f ul page f or ad m inistrator to m onitor each port ’ s usage condition. Also, it is help f ul to troubleshooting net w or k proble m s.
- 50 - 5-4 A dministrator T his section contains m anage m ent f unction on W GSD-1020. Figure 5-5 W GSD-1020 Ad m inistrator W eb Page screen T his m anage m ent f unction is sho w n as belo w : IP A ddress: please re f er to section 5.4.1 S w itch Settings: please re f er to section 5.
- 51 - 5.4.1 IP A ddress T his section allo w s m odi f y the IP address, Subnet Mas k , Gate w a y o f W GSD-1020. Figure 5-6 W GSD-1020 m odi f y IP Address W eb Page screen A f ter m odi f y ing the ne w IP address, Subnet Mas k , Gate w a y , please click “ A pply ” button then the f ollo w ing screen in Figure 5-7 appears.
- 52 - Y ou can click ” Help ” button; the IP Address Overvie w screen in Figure 5-8 appears. Figure 5-8 W GSD-1020 IP Address Overvie w W eb Page screen Click “ Close ” to close this screen.
- 53 - 5.4.2 S w itch Settings T his section provide S w itch basic in f or m ation and allo w m odi f y the S w itch settings Figure 5-9 W GSD-1020 S w itch Basic Settings W eb Page screen 5.4.2.1 Basic: Description: displa y the S w itch s y ste m na m e.
- 54 - Figure 5-10 W GSD-1020 S w itch Advanced Settings W eb Page screen 5.4.2.2 A d v anced: Enter the settings, then click Submit to apply the changes on this page. M A C T able A ddress Entr y A ge-Out T ime: t y pe the nu m ber o f seconds that an inactive MAC ad- dress re m ains in the S w itch ’ s address table.
- 55 - Port-based VLAN m ode Note: M ake sure of “ M ax bridge transit delay bound control ” is enabled before enabling delay bound, because enable delay bound must work under “ M ax bridge transit delay bound control ” is enabled. Y ou can clic k “ Help ” button; the f ollo w ing screen in Figure 5-11 appears.
- 56 - 5.4.3 Console Port Information Displa y the W GSD-1020 console port in f or m ation. Figure 5-12 W GSD-1020 Console In f or m ation W eb Page screen Y ou can click “ Help ” button; the f ollo w ing screen in Figure 5-13 appears. Figure 5-13 W GSD-1020 Console Setting Help W eb Page screen Click “ Close ” to close this screen.
- 57 - 5.4.4 Port Controls T his section introduces detail settings o f per port on W GSD-1020. Figure 5-14 W GSD-1020 Port Controls W eb Page screen State: provide disable or enable an y port o f W GSD-1020. A uto-Negotiation: allo w disable or enable Auto-negotiation o f an y port on W GSD-1020.
- 58 - 5.4.5 T runking T his section displa y s the screen f or trun k ing a group o f ports together to speed up data trans m ission. Figure 5-15 W GSD-1020 T run k ing W eb Page screen 5.4.5.1 A ggregator Setting parameters: S y stem Priorit y : A value used to identi f y the active LACP.
- 59 - Figure 5-16 W GSD-1020 T run k Help W eb Page screen Click “ Close ” to close this screen. 5.4.5.2 Port aggregator status: Provide the Port Aggregator in f or m ation.
- 60 - A ctor: onesel f device. Partner: lin k partner device. A dmin: S w itch de f ault value. Oper: user setting and aggregating result. Priorit y: S y ste m priorit y value. M A C A ddress: S w itch ’ s MAC Address. Ke y : aggregating k e y : 100 serial is LACP static trun k ing.
- 61 - 5.4.5.3 State A cti v it y Allo w setting the LACP State Activit y o f each port. Figure 5-18 W GSD-1020 State Activit y W eb Page screen Please chec k the detail description o f para m eters as belo w: A cti v e( enable ): the port auto m aticall y sends LACP protocol pac k ets.
- 62 - 5.4.6 Filter Database Figure 5-20 W GSD-1020 IGMP Snooping W eb Page screen Please chec k the detail description o f para m eters as belo w : IG M P Snooping: W GSD-1020 support IP m ulticast and allo w enable IGMP protocol on S w itch setting ad- vanced page f ro m the w eb inter f ace.
- 63 - Static M A C A ddress: w hen add a static MAC Address, it re m ains in the S w itch ’ s address table, regardless o f w hether the device is ph y sicall y connected to the S w itch. T his f unction m a k e the S w itch can relearn device ’ s MAC Address w hen the device is disconnected or po w er-o ff and active in the net w or k again.
- 64 - Figure 5-23 W GSD-1020 Port Securit y W eb Page screen Port Securit y : an y port in securit y m ode w ill be “ loc k ed ” w ithout per m ission o f MAC address learning. O n l y the inco m ing pac k ets w ith MAC alread y existing in the MAC address table can be f or w arded nor m all y .
- 65 - Figure 5-25 W GSD-1020 MAC Filtering W eb Page screen M A C Filtering: MAC address f iltering allo w s the W GSD-1020 to drop un w anted tra ff ic.
- 66 - 5.4.7 VL A N Configuration A Virtual LAN ( VLAN) is a logical net w or k grouping that li m its the broadcast do m ain. It allo w s y ou to isolate net w or k tra ff ic so onl y m e m bers o f the VLAN receive tra ff ic f ro m the sa m e VLAN m e m bers.
- 67 - + Figure 5-28 W GSD-1020 T ag-based (IEEE 802.1Q) VLAN Help W eb Page screen.
- 68 - 5.4.7.2 Port VID In order f or an end station send pac k ets to di ff erent VLANs. Itsel f has to be either capable o f tagging pac k ets it sends w ith VLAN tags or attached to a VLAN-a w are .
- 69 - 5.4.7.3 Port Based VL A N Choose Port Based VLAN f unction operation Mode f ro m S w itch Settings. T he f ollo w ing screen in Figure 5-30 appears. Figure 5-30 W GSD-1020 Port Based VLAN W eb Page screen Create a ne w VL A N group and add member ports procedure: 1.
- 70 - Figure 5-31 W GSD-1020 Port Based VLAN setting W eb Page screen Figure 5-32 W GSD-1020 Port Based VLAN setting success f ul W eb Page screen.
- 71 - 5.4.8 Spanning T ree T he Spanning T ree Protocol (S T P) is a standardi z ed m ethod (IEEE 802.1D) f or avoiding loops in Ethernet net w or k s. W hen enable S T P f unction, please ensure onl y one path at a ti m e is active be- t w een an y t w o nodes on the net w or k .
- 72 - Y ou can vie w the spanning tree in f or m ation about Root Bridge. T he screen is sho w n as belo w : Figure 5-35 Root Bridge In f or m ation W eb Page screen T he f ollo w ing para m eter can be con f igured o f per port, a f ter y ou setup co m pleted.
- 73 - Figure 5-38 Spanning T ree Manage m ent Help W eb Page screen Click “ Close ” to close this screen..
- 74 - 5.4.9 Port Sniffer T he Port sni ff er is a m ethod f or m onitor tra ff ic in W GSD-1020 net w or k s. T ra ff ic through ports can be m onitored b y one speci f ic port. T ra ff ic through the in or out m onitored ports w ill be duplicated into sni ff er port.
- 75 - 5.4.10 SNMP Allo w to m anage m ent the W GSD-1020 through the Si m ple Net w or k Manage m ent Protocol (SNMP) It provides protocol that governs the trans f er o f in f or m ation bet w een m anage m ent stations (PC w ith SNMP so f t w are) and agent (s w itches).
- 76 - Figure 5-43 Co mm unit y Strings W eb Page screen Please chec k the detail description o f para m eters as belo w : RO / Read Onl y: enables requests acco m panied b y this string to displa y MIB-object in f or m ation. RW / Read Write: enables requests acco m panied b y this string to displa y MIB-object in f or m ation and set MIB objects.
- 77 - 5.4.11 Securit y Manager Allo w user to m odi f y the User Name and Pass w ord o f W GSD-1020. Figure 5-46 W GSD-1020 Securit y Manager W eb Page screen 1. Input the ne w user na m e. 2. Input the ne w pass w ord. 3. Re-input the ne w pass w ord.
- 78 - 5-5 TFTP Update Firm w are T he f ollo w ing m enu options provide so m e s y ste m control f unctions to allo w user to update latest f ir m w are and re m otel y reboot W GSD-1020 s y ste m . Figure 5-47 W GSD-1020 T F T P Do w nload Ne w I m age W eb Page screen Firm w are update requirements: 1.
- 79 - 5-6 Configuration Backup T his option allo w s y ou to bac k up the W GSD-1020 ’ s con f iguration into a f ile. Figure 5-49 W GSD-1020 T F T P Con f iguration W eb Page screen T F T P Restor.
- 80 - T F T P Backup Configuration: Figure 5-51 W GSD-1020 T F T P Bac k up Con f iguration W eb Page screen Purpose: allo w user save the EEPROM value f ro m this f unction. Usage: Enter the T F T P Server IP Address and Bac k up File Na m e. Clic k “ A pply ” to save current EEPROM value.
- 81 - 5-7 Reset S y stem T his f unction provides reset the S w itch to f actor y de f ault m ode. Figure 5-52 W GSD-1020 Reset S w itch W eb Page screen.
- 82 - 5-8 Reboot S y stem T his f unction allo w s reboot the W GSD-1020. Figure 5-53 W GSD-1020 Reboot S w itch W eb Page screen Y ou can click ” Help ” button; the f ollo w ing screen in Figure 5-54 appears. Figure 5-54 W GSD-1020 Reboot S w itch Help W eb Page Click “ Close ” to close this screen.
- 83 - 5-9 Vie w the State, Link A cti v it y and detail packet information T o vie w the current state, lin k , and detail pac k et in f or m ation f or the W GSD-1020, clic k the RJ-45 jac k s on the s w itch sho w n in y our Bro w ser ’ s screen.
- 84 - 6. SWITCH OPER A TION 6.1 A ddress Table T he Giga S w itch is i m ple m ented w ith an address table. T his address table co m posed o f m an y entries. Each entr y is used to store the address in f or m ation o f so m e node in net w or k , including MAC address, port no, etc.
- 85 - 7.TROUBLESHOOTING T his chapter contains in f or m ation to help y ou solve proble m s. I f Giga S w itch is not f unctioning properl y , m a k e sure the Ethernet S w itch w as set up according to instructions in this m anual.
- 86 - A PPENDIX A NETWORKING CONNECTION A .1 S w itch ‘ s RJ-45 Pin A ssignments 1000Mbps,1000Base T Contact MDI MDI-X 1 BI_DA+ BI_DB+ 2 BI_DA- BI_DB- 3 BI_DB+ BI_DA+ 4 BI_DC+ BI_DD+ 5 BI_DC- BI_DD.
- 87 - Figure A -1: Straight-Through and Crosso v er Cable Please m ake sure your connected cables are w ith sa m e pin assign m ent and color as above picture before deploying the cables into your net w ork.
- 88 - A PPENDIX B TECHNIC A L SPECIFIC A TIONS WGSD-1020 10/100/1000Mbps Intelligent Ethernet S w itch Hard w are Specification Ports Eight 10/ 100Base-T X , t w o 1000Base-T RJ-45 Auto- M DI/ M DI- X ports S w itch Fabric 5.6Gbps S w itch Processing Scheme Store-and-for w ard Throughput (packet per second) 4.
2080-000001-002.
An important point after buying a device Planet Technology WGSD-1020 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Planet Technology WGSD-1020 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Planet Technology WGSD-1020 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Planet Technology WGSD-1020 you will learn all the available features of the product, as well as information on its operation. The information that you get Planet Technology WGSD-1020 will certainly help you make a decision on the purchase.
If you already are a holder of Planet Technology WGSD-1020, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Planet Technology WGSD-1020.
However, one of the most important roles played by the user manual is to help in solving problems with Planet Technology WGSD-1020. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Planet Technology WGSD-1020 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center