Instruction/ maintenance manual of the product MGSW-2402 Planet Technology
Go to page of 31
10/100/1000Mbps Intelligent Ethernet Switch MGSW-2402 User’s Manaul.
- 2 - Trademarks Copyright PLANET Technology Corp. 2002. Contents subject to revision without prior notice. PLANET is a registered trademark of PLAN ET Technology Corp.
- 3 - TABLE OF CONTENTS 1. INTROUCTION ................................................................................................................. ....................... 4 1.1 C HECKLIST .........................................................
- 4 - 1. INTROUCTION 1.1 Checklist Check the contents of your package for following parts: MGSW-2402. User's manual CD. Power cord. 19” rack mount kit.
- 5 - Internal power supply Auto MDI/ MDI-X on each port Network management configuration: − Web-based management − Console and Telnet Configuration − SNMP network management − IEEE 802.1Q Tagging VLAN ( 256 VLAN Group ) − IEEE 802.
- 6 - 2. HARDWARE DESCRIPTION This product series provide three differ ent running speed – 10Mbps, 100Mbps, and 1000Mbps in the same switch and automatically dist inguish the speed of incoming connection. This section describes the hardware features of these Switches.
- 7 - Power Notice: 1. The device is a power-required device, it means , it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data loss or network downtime.
- 8 - 3.WEB-BASED MANAGEMENT This chapter describes how to manage the Swit ch through the at-hand browser like Internet Browser IE 4.0 or Netscape Communicator 4. x or above. Please check the JAVA applet is enabled in your browser’s option or preference.
- 9 - Figure 3-1 : Password Screen The default user name and password is "root". After the password is entered you will see the main menu screen. Figure 3-2: The start up screen of MGSW-2402 Web Page 3.3 Home The Home page displays the configurati on of the MGSW-2402 Intelligent Switch.
- 10 - 3.4 Modules Modules page shows the modules that have inst alled into the MGSW-2402-Slot Intelligent Switch. There are fixed 24x 10/100 Base-TX ports in Module 0, and another 2 slot ( module 1 and module 2 ) are used for expansion.
- 11 - 3.6 Statistics The Statistic page displays the detailed in formation about each port. You can compare and evaluate throughput or other port parameters. All screen data is updated automatically and you can also update the data manually. Figure 3-5 The Statistics Page 3.
- 12 - Figure 3-6 The VLAN Page In the VLAN management window, you will see 2 VL ANs in the page. To select a certain VLAN, you can do the following: Press " >> " button to display the.
- 13 - You can add, edit and remove port members of each trunk and then press " Apply " button after you have finished configur ing the trunks you need.
- 14 - 3.10 Port Security Port Security allows you to restrict specific MAC addresses to reside in some port. For example, a dummy hub is attached to some port for extens ion, and you just only allow 2 users to access this port at the same time, you can use the port security window to set the parameters.
- 15 - Figure 3-10. Port Priority – 802.1p page Programmable Mapping of 802.1p to Internal Priority The received packets with 802.1q tag are assi gned priority according to a flexible and programmable mapping of the 802.1p user-priority tag (3 bits, value from 0 to 7) to the internal priority queue.
- 16 - 3.13 IGMP Multicasting is used to support r eal-time applications such as video conferencing or streaming audio. IGMP ( Internet Group Management Protocol ) allow you to query for any attached hosts who want to receive a specific multicast serv ice.
- 17 - Static addresses are manually entered in to the Static Address Table. 1. Enter the MAC address in the MAC Addre ss field (ex. 00-00-00-00-00-01) and VLAN ID (default is 1) 2. Select the Module and Port you want to asso ciate with this entry with from the Port drop-down box.
- 18 - 3-15 The Port Mirroring page If you want to monitor all receive and transmit packets of one port. You can do the following: Choose the monitored port in " Mirror Source Port " choice box in the corresponding mirror source module. Only one port can be monitored in one module at the same time.
- 19 - Enter the same password in "Password" and "Confirm Password" edit box Press the "Apply" button You should reboot system to let your settings take effect if you have changed one of the IP address, subnet mask and default gateway.
- 20 - Figure 3-18 Save & Reboot page 3.20 Upgrade You can on-line upgrade the firmware of the managed unit. The following steps is needed to upgrade the firmware: Use HTTP or FTP to download the new ve rsion firmware from our website. Enter password in the "Password" edit box.
- 21 -.
- 22 - 4 CONSOLE INTERFACE 4.1 CONNECT TO PC RS-232 serial cable Prepare a RS-232 serial cable. Attach the 9- pin female connector to the male connector on the switch. Plug the other side of this cable to your PC. Hyper Terminal In Windows 95/98/2000/XP,launch “HyperTermi nal”, create a new connection, and adjust settings as below: 4.
- 23 - Figure 4-1 The Main Menu of Console Management 4.2.1. Device settings This menu contains system parameters to disp lay and configure the switch to your network.
- 24 - • Speed/Duplex: allow set Auto- negotiation,100Mbps-f ull/half duplex,10Mbps-full/half duplex • Flow Control: allow enable or disable flow control on each port • Back Pressure: allow enab.
- 25 - Figure 4-5: Spanning Tree 4.2.5 Broadcast Storm Filter This menu contains three items to enabl e or disable Broadcast Storm Filter: ● Enable ● Disable ● Quit Figure 4-6: Broadcast Storm Filter 4.
- 26 - 4.2.7. VLAN Mode (2 modes) This menu contains two items for 2 VLAN mode selection: ● VLAN is valid for all packets Disable ● VLAN is valid for broadcast and multic ast packets, not for unicast packets. ● Quit Figure 4-8: VLAN Mode( 2 modes) 4.
- 27 - 4.2.9.1 Secure IP for Telnet : disable allow any PC login in MGSW-2402 by Telnet , enable allow the PC of secure IP login in MGSW-2402. 4.2.9.2 Secure IP for HTTP : disable allow any PC login in MGSW-2402 by H TTP, enable allow PC of secure IP login in MGSW-2402.
- 28 - Figure 4-12: Factory Default Settings & Reboot System 4.2.12 Reboot System This menu provide reboot the Switch Figure 4-13: Reboot System 4.
- 29 - 5 SOFTWARE UPGRADE PROCEDURE The application software is field upgradable. The upgrade procedure and the required equipment is described in the following section. Note that once the system is up, it is contro lled by an executing application image residing in the flash memory.
- 30 - APPENDIX A NETWORKING CONNECTION When attaching an end-station to the device, a standard straight-through CAT5 cable may be used, even when the end-station is attached via a patch panel. However, when attaching another switch or attaching workstations via hubs, a crosso ver cable will need to be used.
- 31 - APPENDIX B TECHNICAL SPECIFICATIONS Standard IEEE802.3, IEEE802.3u, IEEE802. 3z, IEEE802.3ab,IEEE802.1Q,IEEE802.1d Interface RJ-45 10/100M Ethernet Port 24 - front RS232 Male connector 1 - fron.
An important point after buying a device Planet Technology MGSW-2402 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Planet Technology MGSW-2402 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Planet Technology MGSW-2402 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Planet Technology MGSW-2402 you will learn all the available features of the product, as well as information on its operation. The information that you get Planet Technology MGSW-2402 will certainly help you make a decision on the purchase.
If you already are a holder of Planet Technology MGSW-2402, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Planet Technology MGSW-2402.
However, one of the most important roles played by the user manual is to help in solving problems with Planet Technology MGSW-2402. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Planet Technology MGSW-2402 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center