ICA-101/ICA-101W
User ’ s Manual


Copyright (C) 2003 PLANET Technology Corp. All rights reserved.
The products and programs described in this User ’s Manual are licensed products of PLANET Technology, This User’s Manual contains proprietary information protected by copyright, and this User’s Manual and all accompanying hardware, software, and documentation are copy- righted.
No part of this User’s Manual may be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form by any means by electronic or mechanical. Including photocopying, recording, or information storage and retrieval systems, for any pur- pose other than the purchaser's personal use, and without the prior express written permission of PLANET Technology.
PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
PLANET has made every effort to ensure that this User’s Manual is accurate; PLANET dis- claims liability for any inaccuracies or omissions that may have occurred.
Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. PLANET makes no commitment to update or keep current the information in this User’s Manual, and reserves the right to make improvements to this User’s Manual and/or to the products described in this User ’s Manual, at any time without notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and suggestions.
The is a class B device, In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
The PLANET logo is a trademark of PLANET Technology. This documentation may refer to numerous hardware and software products by their trade names. In most, if not all cases, these designations are claimed as trademarks or registered trademarks by their respective compa- nies.
User’s Manual for PLANET Internet Camera:
Part No. EM-ICA101




As broadband communication gets more and more popular, transferring video and audio through networks has become a major issue. The ICA-101 family provides an advanced Internet Camera solution, supporting wired or wireless Ethernet networking. The ICA-101/ICA-101W can be placed wherever there is a wired/wireless LAN or an available xDSL/Cable modem connection, and the ICA-101 family also supports DDNS. Even when your gateway does not support DDNS, it can still co-operate with the ICA- 101 family and provide live images to Internet users.
The ICA-101 family uses advanced MPEG-4 video compression technology. An ad- vanced microcomputer is integrated into this camera to digitize live video, and then compress the video stream using MPEG-4. The high compression capabilities of MPEG-4 reduce network bandwidth requirements to amazingly low levels. With their Plug-N-Watch capability, a network administrator or system operator can seamlessly complete network deployment in just minutes!
Plug-N-Watch capability to simplify system integration in an existing network environ- ment
The ICA-101 family can be deployed in many different situations and reduce the cost of human resources, offering flexibility, affordability, and reliability for surveillance of manufacturing and other facilities.
Remote Monitoring and Management.
ICA-101 series can fully integrate with your network. By the conveniences of world wide Internet, you can do the monitoring anywhere. Via add-on utility, network adminis- trators can decide whether individuals or the whole team may access ICA-101 series. Multi-user password protection support offers more flexibility while managing ICA-101 series.
Supports TCP/IP networking, SMTP e-mail, HTTP, PPPoE and other Internet related protocols. The ICA-101 family can be applied and utilized in a mixed operating system network environment.
The network administrator can configure and manage ICA-101 family via Windows- based utility or web interface.

Provides the convenience to schedule your recording plan.
Monitoring any suspicious movement in specific area.
In order to view video over Internet, the user must know the Internet IP address of the gateway used by the camera. If the gateway has a dynamic IP address, DDNS (Dy- namic DNS) is required. Since many gateways do not support DDNS, this function is incorporated into ICA-101 family.
With an external microphone attached, audio can be recorded with live images.
The following items should be included:


Front Panel of ICA-101W

Front Panel of ICA-101
LED definition:

Button definition

Reset Button This button has two (2) functions:

ICA-101 series comes with a camera stand accessory with a swivel ball screw head that can be attached to ICA-101 series' bottom screw hole. Attach the camera stand to ICA-101 series and station it for your application. There are three holes located in the base of the camera stand allowing ICA-101 series to be mounted on the ceiling or any wall securely.


1.Connect an Ethernet cable Connect one end of an Ethernet cable to the LAN port located on the ICA-101/101W rear panel and attach the other end to the network device (hub or switch). If you want to use wireless connection for ICA-101W, you can skip this step. 2.Attach the external power supply Connect the provided power adapter to the ICA-101’s connector labeled "5VDC" on rear panel. 3.Check the LEDs The PWR would flash for few seconds to detect network connection. The network indication LEDs (LAN or WLAN) would be on depending on which network type is available.

The initial setup of ICA-101 series must be done through bundled Setup Wizard utility. Before starting installation, please ensure that:
















After finishing the initial setup of ICA-101 series, your camera is ready to use for all users in LAN. This chapter describes how to view live image and manage camera with web browser. The demonstration screens are from ICA-101W, the screens of ICA-101 are similar except some wireless settings. Login
Activate the web browser, type “http://192.168.0.20” in the address box to access Welcome page of ICA-101 series. The lower right of the page shows information of Device Name, Description, and IP Address.

You can view live video via web browser by selecting “View Video” option. Please note that this option needs to download and install an ActiveX control “NetCamPlayer- web.ocx” to your computer. Please change the security settings of your browser with following procedures first.






After the setting is done, a “Security Warning” dialog box would appear while you select “View Video”. Ensure the path and the ocx file name is correct, then click “Yes” to continue.


Once the installation is successfully finished, you will see the live video immediately.

Once you click “Administration” option, a dialog box will pop up. Please enter default username/password as admin/admin to access the management screens.


The management screens contain 5 sub-screens: System, Network, Image, User, and Status.

System Settings:
Device Name:
This field displays the name of your ICA-101 series. It cannot be changed.
Description:
This field is used for entering a descriptive name for the location used by ICA-101 series.
Time:
Enter the current time.
Date:
Enter the current date.
Timezone:

Select the time zone where you are locating from the drop-down list. If you are in a daylight saving area, check the box in front of “Adjust for daylight saving”.
Time Server:
Enable or disable the Time Server feature as required. If enabled, ICA-101 series will contact a Network Time Server at regular intervals and update its internal time.
Server Address:
Enter the Address of the Time Server in this field.
Please find below NTP server web address for your reference to set the time server.
http://www.eecis.udel.edu/~mills/ntp/clock1.htm
http://www.eecis.udel.edu/~mills/ntp/clock2.htm
Update Schedule:
This option determines how often ICA-101 series synchronizes its time with time server.
Apply/Cancel:
After making sure all settings in the System are correct, click on the “Apply” icon to store the settings for ICA-101 series. You can alternatively click on the “Cancel” icon to restore all settings to the values last saved to or retrieved from ICA-101 series.


IP Setting:
There are two options to select from the IP setting.
Access to ICA-101 series is done through assigning a proper IP address. Please make sure to use a vacant IP address when you assign the IP ad- dress for ICA-101 series. This will prevent errors from occurring if the IP address is overlapped.
Obtain Address Automatically (DHCP):
If your network already exists a DHCP server, you can select this option for ICA- 101 series to get an IP address automatically.
Fixed IP Address:
You can select this option and directly enter the network settings.

The default settings are as follows:
· Default IP – 192.168.0.20
· Subnet Mask – 255.255.255.0
Mode:
Use this option to determine the type of wireless communication for ICA-101W. There are two choices of Infrastructure, and Ad-hoc. The default setting for the Connection Mode is Infrastructure.
Authentication Type:
Select appropriate authentication type, Open System or Shared Key, which matches with your current wireless network.
This field is used to setup which wireless network (ESSID: Extended Service Set ID) ICA-101W is to be connected for communication. The ESSID is a unique identifier shared among all points in a wireless network environment. The default ESSID is ANY, which will let ICA-101W connect to ANY access point under Infrastructure mode. To connect ICA-101W to a specific access point on the network, make sure to set ESSID of ICA-101W the same as the AP’s ESSID for communication. Type any string up to 32 characters long (spaces, symbols, and punctuation are not al- lowed) in the ESSID box.
To connect ICA-101W to an Ad-hoc wireless workgroup make sure to set the same wireless channel and ESSID to match with the PC/Notebook wireless channel and ESSID for direct wireless communication under the Ad-hoc wireless workgroup.
Domain:
This option allows you to change the wireless domain of ICA-101W freely.
Channel No:
The pull down menu provides the wireless channel for communication. A "channel" is a range of frequencies to be used in communication between ICA-101W and Ac- cess Point in Infrastructure mode or ICA-101W and PC/Notebook in Ad-hoc mode. Select the appropriate channel from the drop-down list.
The current WEP status is shown here. To configure WEP settings, please click “Configure WEP” button.


WEP Key Setting:
WEP Encryption: Select the option used on your Wireless LAN. None - This is the default setting. If selected, data is not encrypted before being transmitted. 64 Bit Keys - If selected, data is encrypted with the 64-bit default key you en- tered below. 128 Bit Keys - If selected, data is encrypted with the 128-bit default key you en- tered below.
Passphrase: Enter a phrase in this field, then click “Generate” button. ICA- 101W will generate 4 key values automatically.
Default Key: Specify a key value as default WEP key.
Key Value: If WEP Encryption is enabled, you must enter at least one key value. All transmissions are encrypted with Default Key. Other wireless stations must use the same key value in the same position of their key table. (It does not have to be selected as the default key.)
The other key values are optional, and are used only for decrypting data. This al- lows you to use different keys for transmitting and receiving, if required.
When inputting a key value, follow these rules:
DDNS:

Enable or disable DDNS function.
Service Provider:
Choose a service provider from the list. ICA-101 series only supports DynDNS cur- rently.
Host Name:
Enter the host name which DDNS service provider assigned to you.
Account:
Enter the login name for your DDNS account.
Password:
Enter the password for your DDNS account.
Check WAN IP schedule:
This option determines how often ICA-101 series checks the WAN IP status.
Options:
UPnP:
If UPnP is enabled, ICA-101 series will broadcast its availability using UPnP. UPnP compatible systems such as Windows XP will then be able to detect the presence of ICA-101 series.
Second Port:
This option allows you to open a second port for ICA-101 series. The HTTP con- nections (using your Web Browser) can use the port number you specified below instead of the standard HTTP port 80. The configurable port range is 1024~65534. Apply/Cancel:
After making sure all settings in the System are correct, click on the “Apply” icon to store the settings for ICA-101 series. You can alternatively click on the “Cancel” icon to restore all settings to the values last saved to or retrieved from ICA-101 series.


Video Settings:
Resolution:
Select the desired video resolution format ranging from 160x120 and 320x240 (de- fault).
Image Quality:
Select the desired image quality with five levels from very low to very high. Lower image quality will generate more compact file size and use less bandwidth; vise- versa.
Power line frequency:
Please check your local electricity frequency and select proper value for ICA-101.
Adjustment:
Exposure:
Select Automatic or Manual as required.
If manual exposure is selected, an exposure value option will appear in the right. The default value is 32.
Red/Green/Blue:
Adjust the respective color settings with default setting at 32.
Defaults:
Click “Defaults” button to restore Exposure and Red/Green/Blue values back to de- fault.
Options:
Time Stamp:
Enable this option, the current time can be shown on the video image.
Text Overlay:
Enable this option, and enter the text contents in the right. The string you entered will appear on the upper right of video image.

Audio:
Enable Audio function by selecting this option. Please note that this function re- quires an external microphone attached to the MIC IN port of ICA-101 series.
Apply/Cancel:
After making sure all settings in the Image are correct, click on the “Save” icon to store the settings for ICA-101 series. You can alternatively click on the “Cancel” icon to restore all settings to the values last saved to or retrieved from ICA-101 series.

Admin Login:
These fields are used for entering the Administrator ID along with the password to access the Administration settings. Be sure to enter the password twice to confirm the details, once in the Password field and again in the Verify Password field. The default settings for Administrator ID and Password are both admin.
User Access:
You can set the access privileges for users here. The default setting is “Allow access by everyone”. The alternative option is “Allow access by only users in database”. If you

use this option, you have to add users in the database below.
Alerts:
Select “Send E-mail Alert when Motion Detected” and enter the relevant information such as Receiver e-mail Address, Sender e-mail Address, Subject of the mail, SMTP server address, and authentication information if needed.
Motion Detection can be activated by rapid changes of light, as well as by moving object. For this reason, it should be used indoor and the light is fairly constant.
Send to:
Enter the receiver e-mail address in the field.
Show “From” as:
Enter the sender e-mail address in the field. This field must be entered with a valid e-mail format.
Subject:
Enter the subject of outgoing mail.
Outgoing Mail SMTP Server:
Enter the address of SMTP server used to send the mail. Please ensure the server is using SMTP protocol and able to relay mails for you. Some SMTP server may require authentication. You can select “My Mail Server Requires Authentication”, and enter the Account Name and Password fields below for authentication.
The Status screen displays the detailed information of ICA-101 series, includingg Device Name, Description, MAC Address, IP Address, Network Mask, Gateway IP, F/W version, and Current Viewers.


Upgrade Firmware:
Click “Upgrade Firmware” button, a dialog box appears. Use “Browse” button to locate the upgrade file in your computer, then click “Start Upgrade” to start the upgrading.
Do not interrupt the upgrading procedure during proceeding; or the inner component might be permanently damaged.
System Log:
ICA-101 series will record the system events here. You can use these logs for diagno- sis.
Refresh:
Click “Refresh” button to renew the system log.
Restart:
Click “Restart” button to reboot your camera.
Restore Factory Defaults:
Click “Restore Factory Defaults” button to load default settings to camera.

Insert the CD-ROM into the CD-ROM drive to initiate the autorun program. Once completed a menu screen will appear as follows:
STEP 2 To install the Viewer & Recorder Application click on the "Viewer & Recorder" hyper- link to activate the installation procedure for the application program. If the above screen is not shown, you can start the installation as follows.


STEP 4 A “Choose Destination Location” screen appears, you may click on “Next” to accept the recommended destination location or click on “Browse” to select another location. After specifying the desired destination location, click on “Next” to proceed further.

STEP 5 The Select Program Folder prompt will appear providing information of where the application will be located, click on “Next” to continue. Click on “Back” can return to the previous screens.


STEP 6 A message box appears to inform you that an ActiveX plug-in has been installed to your computer..

STEP 7 Once the setup is complete, the following message box pops up. Click “OK” button to close the screen.

After successfully installing the utility, this icon,
, will be added to the desktop. Double click on it to launch the program.

Once the utility is executed, its main screen appears as follow.

The Camera List displays all available ICA-101 series you have defined.
The Current Recordings lists scheduled recording activity in progress.
Click “Add Camera” button, the utility will search available cameras in LAN automati- cally. Once it finds the camera, the detailed information will be displayed. If the camera has enabled User Access control, you have to enter the authorized Name and Pass- word in Login field. Then click “Add” button, the camera will be added to the Camera List immediately.


If you want to add a camera which located on Internet, click “Internet” tab and fill in the necessary information: IP address, port number, and login name/password (if required). Click “Test” button to check the connection to the camera, and click “Add” to add the camera to Camera List.

If a camera’s IP address or port number has been changed, you can use this option to rebuild the connection. Select an existing camera from Camera List, click “Modify Camera” button. After modifying, you can click “Test” button to check the connection. Click “Save” to save the changes.


Select an existing camera from Camera List, click “Delete Camera” button to remove it from the list.
To view live video with utility, select an existing camera from Camera List, then click “View” button. The live video of the selected camera will pop up immediately. There
are three control buttons available in this screen.
is for stop.

Click “Files” button to check the files which have been recorded in your computer. Select a file and click “Play”, your computer will use Media Player program to play the file. Select a file and click “Delete” to delete it. Click “Explore” button to open the folder which stores these video files.

is for play, · is for re- · cording, and

To set recording preferences, click “Preferences” button. You can modify File Location and Time Limit here. The Time Limit sets the maximum time period of a recording session which started by clicking button on the View screen.

To schedule a recording session, click “Schedule” button. The screen displays all scheduled recordings.

Click “Add” button, and select desired parameters, then click “Save” button. The new schedule will be added to the list immediately. To modify an existing schedule, select the schedule and click “Modify”. Change the parameters to desired values, then click “Save”. To delete an existing schedule, select the schedule and click “Delete” button. The record will be removed from list right away.

A
Q: What is an Internet Camera?
A: The Internet Camera is a standalone system connecting directly to an Ethernet or Fast Ethernet network. And ICA-101W also supports the wireless transmission based on the IEEE 802.11b standard. It is different from the conventional PC Cam- era, the Internet Camera is an all-in-one system with built-in CPU and web-based solutions providing a low cost solution that can transmit high quality video images for monitoring. The Internet Camera can be managed remotely, accessed and controlled from any PC/Notebook over the Intranet or Internet via a web browser.
Q: What algorithm is used to compress the digital image?
A: ICA-101 series utilizes the MPEG-4 image compression technology providing high quality images for users. The high compression capabilities of MPEG-4 reduce network bandwidth requirements to amazingly low levels.
Q: What is the wireless transmission range for ICA-101W?
A: Generally the wireless distance can go up to 100 meters indoors and up to 300 meters outdoors. The range is limited by the number of walls, ceilings, or other objects that the wireless signals must pass through. Typical ranges vary depends on the types of materials and background Radio Frequency (RF) noise in your home or business and the configuration setting of your network environment.
Q: Can ICA-101 series be used outdoors?
A: ICA-101 series is not weatherproof. It needs to be equipped with a weatherproof case to be used outdoors, and it is not recommended.
Q: What network cabling is required for ICA-101 series?
A: ICA101 series uses Category 5 UTP cable allowing 10 Base-T and 100 Base-T networking.
Q: Can ICA-101 series be setup as a PC-cam on the computer?
A: No, ICA-101 series can be used only on Ethernet and Fast Ethernet network.
Q: Can ICA-101 series be connected on the network if it consists of only private IP addresses?
A: Yes, ICA-101 series can be connected to LAN with private IP addresses.
Q: Can ICA-101 series be installed and work if a firewall exists on the network?
A: Yes, you can use Second Port function to allow the traffic from Internet passing through firewall and access your ICA-101 series..
Internet Camera Features · Internet Camera Installation

Appendix B Trouble Shooting
Q: I cannot access the Internet Camera from a web browser.
A: If ICA-101 series do not respond, check the following:
Open the MS-DOS window or command prompt window. Enter the command: ping 192.168.0.20 If no response is received, either the connection is not working, or your PC's IP address is not compatible with ICA-101 series’ IP Addresses. (See next item.)
Q: The Viewer & Recorder utility does not list my ICA-101 series.
A: Please check the following:
Q: Why does the Internet Camera work locally but not externally?
A1: Might be caused from the firewall protection. Need to check the Internet firewall with your system administrator.
A2: The default router setting might be a possible reason. Need to double check if the configuration of the default router settings is required.
Q: Why do a series of broad vertical white lines appear through out the image?

Appendix A - Troubleshooting
A: A likely issue is that the CMOS sensor becomes overloaded when the light source is too bright such as direct exposure to sunlight or halogen light. You need to reposition the Internet Camera into a more shaded area immediately for the bright light will damage the CMOS sensor.
Q: There is bad focus on ICA-101 series, what should be done?
A: The focus might not be correctly adjusted for the line of sight. You need to adjust the focus manually by rotating the lens clockwise or counterclockwise..
Q: Noisy images occur. How can I solve the problem?
A1: The video images might be noisy if ICA-101 series is used in a very low light environment. To solve this issue you need more light.
Q: There is a poor image quality, how can I improve the image?
A1: A possible cause might be the incorrect display properties configuration for your desktop. You need to open the Display Properties on your desktop and configure your display to show at least 65’000 colors, for example at least 16-bit.
Applying only 16 or 256 colors on your computer will produce dithering artifacts in the image.
A2: The configuration on ICA-101 series image display is incorrect. You need to adjust the image related parameter to improve images such as exposure, and col- ors. Please refer to the Image section of Chapter 4 for detail information.
Q: There are no images available through the web browser?
A: The ActiveX might be disabled. If you are viewing the images from Internet Ex- plorer make sure ActiveX has been enabled in the Internet Options menu. Alternatively, you can use the Viewer & Recorder utility for viewing the required images.


LED indicator PWR, ACT, LAN PWR, ACT, LAN, WLAN
Additional Features Image recording, NTP Support, Email auto send; System event log, Web or Utility firmware upgrade, Motion detec- tion, DDNS, UPnP, Open second port, Time stamp, Real- time monitoring
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.