Gigabit Ethernet Switch
GSD-503/GSD-504
GSD-803/GSD-804
User's Manual

Copyright © PLANET Technology Corp. 2005.
Content subjects to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
PLANET Technology does not warrant that the hardware will
work properly in all environments and applications, and makes
no warranty and representation, either implied or expressed,
with respect to the quality, performance, merchantability, or
fitness for a particular purpose.
PLANET has made every effort to ensure that this User's
Manual is accurate; PLANET disclaims liability for any
inaccuracies or omissions that may have occurred.
Information in this User's Manual is subject to change without
PLANET. PLANET assumes no responsibility for any
inaccuracies that may be contained in this User's Manual.
PLANET makes no commitment to update or keep current the
information in this User's Manual, and reserves the right to
make improvements to this User's Manual and/or to the
products described in this User's Manual, at any time without
If you find information in this manual that is incorrect, misleading,
or incomplete, we would appreciate your comments and
suggestions.

This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the Instruction manual,
may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be
required to correct the interference at its own expense.
This is a Class A product. In a domestic environment, this
product may cause radio interference, in which case the user
may be required to take adequate measures.
PLANET Gigabit Ethernet Switch User's Manual
Part No.: 2010-A33110-000

Check the contents of your package for following parts:
。 Gigabit Ethernet Switch x1
。 User's manual x1
。 Power adapter x1
If any of these are missing or damaged, please contact your dealer
immediately, if possible, retain the carton including the original
packing material, and use them against to repack the product in case
there is a need to return it to us for repair.
This Gigabit Ethernet Switch User Manual is structured as
follows:
The chapter explains the feature, functionality and the physical
installation of the Switch.
Chapter 3 Switch operation
The chapter explains the Gigabit Ethernet Switch transmit operation.
The chapter explains the troubleshooting of the Gigabit Ethernet
Switch.
This chapter contains cable information of the Gigabit Ethernet
Switch.
Chapter 2 Installation · Chapter 4 Troubleshooting · Appendix A

。 Complies with IEEE802.3, 10Base-T, IEEE802.3u,
100Base-TX and IEEE802.3ab, 1000Base-T
。 IEE802.3x, full-duplex flow control compliant; back-pressure,
。 10/100/1000Mbps 5/8-port Gigabit Switch (RJ-45)
。 8K MAC address table auto-ageing,
112K(GSD-503/GSD-504) / 144K(GSD-803/GSD-804) bytes
。 9.6K Jumbo packet size support
。 Per port Auto-MDI, MDI-X detection
。 Non-blocking, Store and Forward switching architecture
。 Automatic source address learning and aging
half-duplex flow control · packet buffer


155 x 86 x 26 mm (503) 155 x 86 x 26 mm (803) Dimensions (W x D x H)
170 x 87 x 32mm (504) 170 x 87 x 32 mm (804)
Flow Control IEEE 802.3x full duplex operating and flow control
Packet Control Runt & CRC filtering, Broadcast storm control
Network Standards IEEE 802.3 (Ethernet), IEEE 802.3u (Fast Ethernet)



This section describes the functionalities of the Gigabit Ethernet
Switch’s components and guides how to install it on the desktop.
Basic knowledge of networking is assumed. Please read this chapter
completely before continuing.
The PLANET GSD-503/GSD-504 and GSD-803/GSD-804 are 5/8
ports 10/100/1000Mbps Ethernet switches in a compact housing for
easily desktop placement.
The GSD-503/GSD-504 and GSD-803/GSD-804 provide 10/16Gbps
non-blocking switch fabric, 8K MAC Address table, all support 802.3x
full duplex flow control and also offers wire-speed packet transfer
performance without risk of packet loss.
All five/eight RJ-45 copper interfaces support 10/100/1000Mbps
auto-negotiation for optimal speed detection through RJ-45 Category
3, 4, 5 or above cables. MDI/MDI-X auto detection is provided for
direct wire connection to any Ethernet device without requiring
crossover cables.
2.1.1 Product Overview
PLANET GSD-503/GSD-504/GSD-803/GSD-804 are Gigabit Ethernet
switches with 5/8 RJ-45 10/100/1000 Mbps ports for high-speed
network connectivity. The switches can also automatically identify and
determine the correct transmission speed and half/full duplex mode of
the attached devices with its 5/8 ports. The Gigabit port with jumbo
frame feature supported, can handle extremely large amounts of data
transmission in a secure topology linking to a backbone or high-power
servers.


ensure low latency and high data integrity, eliminates unnecessary
traffic and relieves congestion on critical network paths. With an
up to 4K different MAC address and enables filtering and forwarding at
Figure 2-1 & 2-2 show the front panel and rear panel of GSD-503
Figure 2-3 & 2-4 show the front panel and rear panel of GSD-504


Figure 2-5 & 2-6 show the front panel and rear panel of GSD-803
Figure 2-7 & 2-8 show the front panel and rear panel of GSD-804

ower Notice:
till it is powered. If your networks should active all the time, please
consider using UPS (Uninterrupted Power Supply) for your device.
It will prevent you from network data loss or network downtime.
help to protect your switch from being damaged by unregulated
surge or current to the Switch or the power adapter.
alling the Switch
This part describes how to install yo
ur Gigabit Ethernet Switch and
make connections to it. Please read the following topics and perform
the procedures in the order being presented.
2.2.1 Desktop Installation
To install the switch on desktop, simply follow the next steps:
the switch.
surrounding objects.

environmental restrictions discussed in Chapter 1, Section 1.4
Product Specification.
A. Connect one end of a standard network cable to the
10/100/1000 RJ-45 ports on the Back of the switch.
B. Connect the other end of the cable to the network devices such
as printer servers, workstations or routers…etc.
cabling with RJ-45 tips. For more information, please see the Cabling
Specification in Appendix A.
A. Connect one end of the power cable to the switch.
B. Connect the power plug of the power cable to a standard wall
outlet.
When the switch receives power, the Power LED should remain solid
Green.

The Switch is implemented with an address table. This address table
composed of many entries. Each entry is used to store the address
information of some node in network, including MAC address, port no,
etc. This information comes from the learning process of Ethernet
Switch.
When one packet comes in from any port, the Switch will record the
source address, port no. And the other related information in address
table. This information will be used to decide either forwarding or
filtering for future packets.
When one packet comes from some port of the Ethernet Switching, it
will also check the destination address besides the source address
learning. The Ethernet Switching will lookup the address-table for the
destination address. If not found, this packet will be forwarded to all
the other ports except the port, which this packet comes in. And these
ports will transmit this packet to the network it connected. If found, and
the destination address is located at different port from this packet
comes in, the Ethernet Switching will forward this packet to the port
where this destination address is located according to the information
from address table. But, if the destination address is located at the
same port with this packet comes in, then this packet will be filtered.
Thereby increase the network throughput and availability.

Store-and-Forward is one type of packet-forwarding techniques. A
Store-and-Forward Ethernet Switching stores the incoming frame in
an internal buffer, do the complete error checking before transmission.
Therefore, no error packets occurrence, it is the best choice when a
network needs efficiency and stability.
The Ethernet Switch scans the destination address from the
packet-header, searches the routing table provided for the incoming
port and forwards the packet, only if required. The fast forwarding
makes the switch attractive for connecting servers directly to the
network, thereby increasing throughput and availability. However, the
switch is most commonly used to segment existing hubs, which nearly
always improves overall performance. An Ethernet Switching can be
easily configured in any Ethernet network environment to significantly
boost bandwidth using conventional cabling and adapters.
Due to the learning function of the Ethernet switching, the source
address and corresponding port number of each incoming and
outgoing packet are stored in a routing table. This information is
subsequently used to filter packets whose destination address is on
the same segment as the source address. This confines the network
traffic to its respective domain, reducing the overall load on the
network.
The Switch performs "Store and forward" therefore, no error packets
occur. More reliably, it reduces the re-transmission rate. No packet
loss will occur.
The STP ports on the Switch have built-in "Auto-negotiation". This
technology automatically sets the best possible bandwidth when a

connection is established with another network device (usually at
Power On or Reset). This is done by detect the modes and speeds at
the second of both device is connected and capable of, both
10Base-T and 100Base-TX devices can connect with the port in either
Half- or Full-Duplex mode. 1000Base-T can be only connected in
Full-duplex mode.

This chapter contains information to help you solve problems. If Giga Switch is not functioning properly, make sure the Ethernet Switch was set up according to instructions in this manual.
Some stations cannot talk to other stations located on the other port Solution:
The address table may contain older information than of the address table of that node. Please power down to refresh the address information.
Performance is bad Solution:
Check the full duplex status of the Ethernet Switch. If the Ethernet Switch is set to full duplex and the partner is set to half duplex, then the performance will be poor.
Why the Switch doesn't connect to the network Solution:
Check the LNK/ACT LED on the Switch Try another port on the Switch I Make sure the cable is installed properly Make sure the cable is the right type Turn off the power. After a while, turn on power again

This page intentionally left blank!

2 BI_DABI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DCBI_DD-
6 BI_DBBI_DA-
7 BI_DD+ BI_DC+
8 BI_DDBI_DC-
Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard.
When connecting your 10/100Mbps Ethernet Switch to another switch, a bridge or a hub, a straight or crossover cable is necessary. Each port of the Switch supports auto-MDI/MDI-X detection. That means you can directly connect the Switch to any Ethernet devices without making a crossover cable. The following table and diagram show the standard RJ-45 receptacle/ connector and their pin assignments::
1000Mbps, 1000Base T · Contact MDI MDI-X


There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: